Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 14 at 2:00 PM ET

Register Free →

NORTRAX, LLC

NORTRAX, LLC is a federal contractor, registered under UEI LP2HWLH9LVA5. It has been awarded $207,880 in federal contracts. Primary work spans Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance, Unknown NAICS, and Farm and Garden Machinery and Equipment Merchant Wholesalers. Top awarding agencies include Department Of Agriculture and Department Of The Interior.

Contact Information

Registration and classification details

Registration

UEI Code

LP2HWLH9LVA5

Federal Contracting Overview

Award totals, agency breakdown, NAICS distribution, and geographic footprint.

Key Performance Metrics

Awards Count

18

All time

Active

0

Currently performing

Completed

18

Past period of performance

Total Awards

All time

Contracts

Prime · all time

Subcontracts

Sub · all time

Grants

Prime · all time

Subgrants

Sub · all time

Award Analytics & Distribution

Awards by Agency
Awards by Agency Over Time
Awards by Place of Performance

Compete with NORTRAX, LLC

Track the contractors you bid against, and the work they win

Award history, agency mix, and NAICS coverage for NORTRAX, LLC

AI-powered matching against your own capabilities and past performance

Teaming and subcontracting signals on every award

Automated alerts when a competitor wins in your market

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS

Open opportunities in NORTRAX, LLC's top NAICS codes and agencies

NAICS: 238910
New
Keystone Job Corps Building 14 Demo
Solicitation # keystone-job-corps-building-14-demo
The Keystone Job Corps is soliciting bids for the complete demolition of Building 14, the old security building, and its foundation at the Keystone Red Rock Job Corps Center in Drums, Pennsylvania. The scope of work includes the demolition of an old septic system, removal of debris, trees, and rocks, and the subsequent backfilling, grading, and seeding of the area. Critical infrastructure requirements include capping the sewer line and disconnecting building power while ensuring that power and communications remain operational for the guard shack and the mountain pump house and water tank, which may require the installation of new telephone poles. Additionally, the contractor must replace the water shut-off valve with a straight pipe, a task that must be completed within a single day between 8:30 AM and 3:00 PM to minimize water service disruptions for students. This is a small business set-aside solicitation requiring contractors to be active and registered in SAM.gov. The selected contractor is responsible for providing all necessary permits, dumpsters for haul-off, chain of responsibility letters for debris, and traffic control flaggers on Foothills Drive to manage heavy equipment and local traffic. Bidders must provide separate costs for labor and materials. Compliance with the Davis-Bacon Act is mandatory, requiring the payment of prevailing wages and the submission of certified payroll.
Keystone Job Corps

POSTED

about 5 hours ago

DEADLINE

in 6 days
View Details
NAICS: 811310
New
SLED
Emergency Power Supply Systems [Industrial Generators and Automatic Transfer Switch] Preventative Maintenance, Testing and Repair Services
Solicitation # IFB-26-0395
The City of Phoenix Public Works department is soliciting bids under IFB-26-0395 for a five-year, firm-fixed-price contract to provide comprehensive preventative maintenance, testing, and repair services for its Emergency Power Supply Systems. The scope of work covers over 300 stationary and mobile industrial generators, automatic transfer switches, and fire pump subsystems across various city facilities, including Aviation, Water Services, and the Convention Center. Required services include regular inspections, fuel delivery, fuel testing, fuel polishing, load bank testing, and 24/7 emergency response. To be considered responsive, vendors must possess at least 10 years of experience, manufacturer training, and the ability to provide a 24/7 on-call technician. The contract mandates strict adherence to safety and regulatory standards, including OSHA and NFPA requirements for hazardous materials labeling and the implementation of a written heat safety plan for outdoor work. Contractors must obtain security clearances and background checks through the Police Department for all personnel. Award decisions will be based on responsiveness and responsibility, with a blind drawing used to resolve equal low offers. Evaluation factors include technical capability, resource availability, safety records, and performance history. Payment is processed within thirty to forty-five calendar days following the submission of a correct invoice and signed service ticket, with no partial payments authorized on individual purchase orders.
Public Works

POSTED

about 15 hours ago

DEADLINE

in 11 days
View Details
NAICS: 811310
New
SLED
WRRF West Substation Transformer Repair
Solicitation # 27-005
The City of Hayward Public Works department is soliciting all-inclusive quotes for the complete repair of the West Substation transformer at the Water Resources Recovery Facility located at 3700 Enterprise Avenue, Hayward, CA. The existing Square D Schneider Electric unit is in poor condition and requires new windings, new insulation, 466 gallons of new FR3 fluid, and a light-gray paint finish to return to full service. The project must be completed within 20 weeks of the agreement or purchase order issuance. The successful contractor is responsible for all removal, transportation, repair, delivery, installation, and startup activities, ensuring the completed transformer impedance is 5.67 percent. Qualified bidders must hold a valid California C-10 Electrical Contractor license and demonstrate at least five years of experience in repairing liquid-filled power transformers of similar specifications. Proposals must include a detailed work plan, a quality-control plan, three references from the last five years, and proof of a City of Hayward business license. Evaluation factors include the capabilities of the repair facility to handle a transformer of approximately 11/32 pound tons, the experience of key personnel, and the quality of testing equipment. Mandatory submissions include a noncollusion affidavit, a nondiscriminatory employment practices certification, and an affirmation of non-involvement in the production of nuclear weapons. Electronic proposals are due by October 28, 2026, at 12:00pm.
Public Works

POSTED

3 days ago

DEADLINE

in 16 days
View Details