Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Department Of Defense was posted on February 11, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

174 ATKW Security Forces Gate Shack

Closed
W50S8N26QA013Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 332311
New
SLED
Myrtle Grove Fire Station 11 - Pre-Engineered Metal Building System
Solicitation # PD 26-27.010
Escambia County is soliciting bids for the procurement of a complete Pre-Engineered Metal Building (PEMB) system for the new Myrtle Grove Fire Station 11 in Pensacola, Florida. The scope of work includes the engineering, fabrication, delivery, and erection of primary and secondary structural framing, roofing, and wall panels. The facility will feature administrative and operational areas, apparatus bays, firefighter dormitories, a communications room, and essential support spaces. The PEMB system must integrate with the architectural design without modifying the building footprint, roof configuration, or clearances without prior written approval from the County and Architect of Record. Bids are due by December 3, 2026, at 10:00 am via the OpenGov e-procurement portal. The contract will be awarded on an all-or-none total basis to the most responsive and responsible firm offering the lowest bid. Required submission documents include E-Verify certification, a sworn statement on entity crimes, a conflict of interest form, and acknowledgment of the Cone of Silence. The anticipated lead time for the PEMB system is 90 calendar days, and the successful contractor must provide a detailed project schedule within 10 days of the award. The project requires strict adherence to technical specifications, including specific labeling for electrical and communications systems and compliance with ADA, OSHA, and EEO standards. The contractor must furnish separate performance and payment bonds and maintain general liability completed operations coverage until the Florida statute of repose expires. Payments will be processed in accordance with the Local Government Prompt Payment Act of Florida. Acceptance of the work is contingent upon successful tests, inspections, the completion of punch lists, and the submission of record drawings and operation manuals.
Purchasing

POSTED

1 day ago

DEADLINE

in 16 days
NAICS: 332311
New
Federal
Prefabricated steel sheds
Solicitation # W911S227U0156
Solicitation W911S227U0156 is a Total Small Business Set-Aside Request for Quotation issued by the Department of Defense for the turnkey procurement and installation of two prefabricated steel sheds. The project requires the contractor to provide all materials, tools, rigging, and labor to erect structures approximately 25 feet in length by 20 feet in width on existing concrete slabs located indoors within a larger host building. Key technical specifications include a strict maximum finished height of 19 feet, a flat or low-slope roof with a maximum pitch of 1 to 12, and the use of red-oxide steel for primary and secondary structural members. Wall and roof panels must be 26-gauge unpainted galvalume or bare steel, and both structures must be equipped with R-11 thermal insulation blankets. The contractor is responsible for providing framed openings for one 12x12 foot overhead door and one standard personnel door, as well as providing the labor to install Government-furnished electrical and HVAC components. Award will be granted to the responsible offeror determined to be most advantageous to the Government based on price and technical acceptability. Required technical submittals include shop drawings, insulation data sheets, and a minimum one-year warranty. All quotes must be submitted via the PIEE Solicitation module and include a completed certification of country of origin to be considered responsive. Performance is expected within 30 days of award on an F.O.B. destination basis.
W6QM Micc-Ft Drum

POSTED

1 day ago

DEADLINE

in 1 day

General Info

NAICS

332311 - Prefabricated Metal Building and Component Manufacturing

Place of Performance

Syracuse, NY, 13211, USA

Set-Aside

SBA

Documents

3
DOCX, High priority: read this first1 page · specifications
High
PDF, High priority: read this first49 pages · ifb
High
PDF, Low priorityother
Low

Read all 3 documents

Every page of every file, in your free workspace.

Read the documents

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

View Full Breakdown

This one is closed. Find the next one like it.

Open contracts like this one, right now:

  • High-Strength Structural Steel Plate SupplierOpen now, due in 11 days
  • Myrtle Grove Fire Station 11 - Pre-Engineered Metal Building SystemOpen now, due in 16 days
See open contracts like this

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

1 update
PhaseClosed
Posted

Solicitation

Notice updated

Notice details unchanged. Attachments may have changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W7NR Uspfo Activity Nyang 174
Contacts2 people available
OfficeSYRACUSE, NY, 13211-7099, USA

Full Description

Show more

This solicitation is issued as a Request for Quotation (RFQ), solicitation number W50S8N-26-Q-A013 in accordance with FAR Parts 12 and 13, and is in accordance with provisions and clauses effective in Federal Acquisition Circular (FAC 2025-06 effective 1 OCT 2025). The North American Industry Classification System (NAICS) number is 332311 and the small business size standard is 750 employees.  The proposed acquisition is 100% set-aside for Small Businesses.


There will be a site visit on Tuesday, 18 February 2026 at 10:00 EST. Please email Briana McCaffery at Sign up to see this detail with participants full name, DOB, license number, and state of issue NLT 2:00 PM EST 17 February 2026. Site visit IS NOT required to submit a quote.


Line Items:


CLIN 0001 : Ballistic Guard House 5’ wide X 8’ long X 8’ High, UL752 Level 3


Minimum Specifications/Prefabricated Buidling Specs:


UL 752 Level 3 Elements:



  • All material used for exterior walls: ¼” certified steel plates, UL752 Level 3
  • (2) 36” X 80” Bullet resistant UL 752 Level 3 solid sliding door, latch lock, weather stripping. Door to be glazed with UL Level 3 clad polycarbonate glazing, tinted
  • 360 Degree view UL 752 Level 3 bullet resistant windows tinted, and fixed glad polycarbonate glass mounted against ballistic walls, 36” tall.
  • (1) UL 752 Level 3 AC shroud welded around the AC opening

Other building elements:


  • 3” structural steel tubing frame
  • Insulation: R-18
  • VCT flooring (color TBD)
  • Exterior wall panels factory finish UL 752 Level 3 bullet resistant protection exterior face, 16 ga heavy duty steel interior, panels galvanized and mechanically fastened.
  • Ceiling finish with 11-ga heavy duty steel, mechanically fastened to provide smooth flat interior
  • Roof finish 11-ga heavy duty steel galvanized and welded to provide smooth flat exterior if acceptable for aesthetic exterior.
  • (2) 18” overhangs on doorways

Electrical/HVAC


  • Electrical package consists of 12-ga minimum copper wiring in 1/2” EMT surface mounted conduit and attached to surface mounted 2x4 boxes
  • (2) single pole switches wired
  • (6) 115V duple receptacles, wired
  • 12 Amp 12 space circuit breaker box with 4 circuits
  • (4) T8 fluorescent light fixtures, wired
  • (6) Exterior floodlights with switch
  • (1) Wall mounted HVAC unit, 18,000BTU cooling and 16,000 BTU heating with ballistics shroud
  • (1) Power box location must match existing structure exact location and height to avoid running of new cables to location.

INSTALLATION:


  • Existing prefabricated gate shack will need to be removed and disposed at contractors expense.
  • New prefabricated gate shack will need to be delivered and placed on existing pad where previous gate shack existed.
  • Minimum of 4 anchor points built in.

- Delivery is 120 days after award


  • Delivery Address is: 174th Attack Wing ,6001 E. Molloy Rd. Syracuse, NY 13211

- Shipping cost must be included in total price


- Award will be based on lowest price


- All quotes are due NLT 2:00 p.m. eastern on 26 Februrary 2026


Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS