DEFLECTOR, DIRT AND LIQ
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
General Info
Place of Performance
2083 NORMANDY DRIVE DOOR 113 TO 134, NEW CUMBERLAND, PA, 17070-5002, USASet-Aside
Documents
1AI Contract Breakdown
Uniform Contract FormatContract not broken down yet
CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.
Timeline
Response Deadline
Organization & Contact Information
Full Description
DEFLECTOR,DIRT AND
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS
(IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE
DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB
AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
OSHKOSH DEFENSE LLC 75Q65 P/N 2KP235
PLASAN NORTH AMERICA, INC. 535V1 P/N 0259970827-00
DLA issues this document using the DoD authorized unit of issue, please refer to the following URL to determine the corresponding ANSI X12 unit of issue.
https://view.officeapps.live.com/op/view.aspx?src=https%3A%2F%2Fwww.dla.mil%2FPortals%2F104%2FDocuments% 2FDLMS%2FeApplications%2FLogDataAdmin%2FUnitofIssueandPurchaseUnit.xlsx&wdOrigin=BROWSELINK
CLIN PR PRLI UI QUANTITY UNIT PRICE TOTAL PRICE.
0001 7019025683 0001 EA 1.000
NSN/MATERIAL:2530015662564
DELIVERY (IN DAYS):0168
DELIVER FOB: ORIGIN
QTY VARIANCE: PLUS 0% MINUS 0%
INSPECTION POINT: DESTINATION
ACCEPTANCE POINT: DESTINATION
PREP FOR DELIVERY:
PKGING DATA MIL-STD-2073-1E
QUP:001 PRES MTHD:10 CLNG/DRY:1 PRESV MAT:00
WRAP MAT:CA CUSH/DUNN MAT:AD CUSH/DUNN THKNESS:F
UNIT CONT:F2 OPI:M
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
SPECIAL MARKING CODE:ZZ -ZZ Special Requirements
PALLETIZATION SHALL BE IN ACCORDANCE WITH RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
SPE7L3-27-T-2329
SECTION B
PR: 7019025683 PRLI: 0001 CONT’D
CUSHIONING MATERIAL: AD CONTRACTOR SHALL DETERMINE THE BEST ECONOMICAL
AND PERFORMANCE APPLICATION OF BLOCKING AND BRACING SUPPLIES AND
EQUIPMENT TO ENSURE THE PACKAGE DESIGN MEETS MIL-STD-2073 PACKAGE DESIGN
PERFORMANCE AND VALIDATION REQUIREMENTS.
BLOCKING AND BRACING. ITEMS WHICH DO NOT COMPLETELY FILL THE SHIPPING
CONTAINER SHALL BE BLOCKED, BRACED, ANCHORED, OR OTHERWISE IMMOBILIZED
WITHIN THE CONTAINER. THE MATERIAL SELECTED FOR BLOCKING AND BRACING AND
THE DESIGN AND APPLICATION OF THE BLOCKING AND BRACING SHALL BE
COMPATIBLE WITH THE LOAD TO BE SUPPORTED AND THE SIZE, SHAPE, AND
STRENGTH OF BEARING AREAS OF THE ITEM.
Coatings and barriers. Protection shall be provided for strippable compound coatings and for grease-proof, water-proof, or water vapor-proof barriers at points of contact with blocking, bracing, or projecting members of containers. Cushioning materials shall be applied to reduce the static pressure at points of contact to 30 pounds or less per square inch.
Surface abrasion and corrosion. When the surface of the item in contact with the blocking and bracing can be damaged by relative motion between the contacting surfaces or could become corroded as a result of such contact, the contacting surfaces shall be separated by a barrier material meeting protective surface corrosion requirements for wrapping, cushioning and dunnage materials shall be used in contact with unprotected surfaces susceptible to damage from corrosion or deterioration.
Wood and plywood. Wood or plywood may be used alone or in combination for blocking and bracing. Wood or plywood blocking and bracing members shall bear against only those parts of the packed item capable of withstanding the applied dynamic forces or shall bear against blocking pads or pressure strips that adequately distribute these forces. Wood or plywood blocking and bracing shall be designed to permit easy removal without damage to the item. Strengths of wood and plywood members may be calculated from information given in USDA Agricultural Handbook No. 72.
Wood. Wood used for blocking and bracing shall conform to ASTM-D6199. Once wood member of each size and type used in the blocking and bracing shall be tested for moisture content. Structural members [those subject to critical bending stresses) shall conform to class 1 of ASTM-D6199. All other blocking and bracing members shall conform to class 3. Whenever possible, wood blocks or braces shall be placed so that the load is applied against the end grain of the member. Ends of braces shall be socketed or fitted and secured into appropriate notches in load-bearing members.
Plywood. Plywood used for blocking and bracing shall conform to A-A-55057, group A, (grade 3-4, type II) or group B, (C-D, interior with exterior glue).
Nails and nailing. Nails shall conform to the requirements of specification ASTM-F1667. ASTM-F1667 that are not clinched shall be cement coated, etched, or mechanically deformed (helically or annularly threaded). Unclinched nails shall be as long as practicable without splitting the material, but not shorter than three times the thickness of the member holding the nail-head for ten penny nails and smaller, or not shorter than the thickness of the same member plus 1-1/2 inches for twelve penny nails and larger. Nails loaded in shear blocking and bracing joints need not be clinched. End grain nailing in solid wood or edge nailing in plywood shall not be permitted. Nails shall be driven through the thinner member into the thicker member wherever possible. Nails shall not be subject to withdrawal stresses. Nails shall be driven not closer to the end of a piece of lumber than the thickness of the piece and not closer to its side than one-half its thickness. There shall be at least two nails in each joint. Lateral loading of nails for blocking and bracing shall be in accordance with table 111.
SPE7L3-27-T-2329
SECTION B
PR: 7019025683 PRLI: 0001 CONT’D
Ends of blocks and braces shall not be fastened to a wood container by end-grain nailing, toe nailing, or similar methods but shall be fastened to a sturdy part of the container or held in place by parallel cleats or other side-grain nailing methods. Blocking and bracing shall be applied against areas of the item(s) that are of sufficient strength and rigidity to resist damage.
WOODEN CONTAINER SHALL INCLUDE SHEATHING ON ALL SIDES, ENDS, TOP AND BOTOOM OF THE SPECIFIED CONTAINER.
ZZ SPECIAL MARKING REQUIREMENTS: 02 ARROW UP OPEN THIS SIDE
REQUIRED: PER MIL-STD-129, SERIAL NUMBER SHALL BE MARKED ON THE UNIT, INTERMEDIATE<(>,<)> AND SHIPPING CONTAINERS.
MECHANICAL HANDLING IS REQUIRED.
PACKAGE DESIGN PERFORMANCE CRITERIA IS SAFE DELIVERY TO ULTIMATE USER.
IP025: PACKAGING, MARKING, AND SHIPPING OF HAZARDOUS MATERIALS
PARCEL POST ADDRESS:
W25G1U
W1A8 DLA DISTRIBUTION
DDSP NEW CUMBERLAND FACILITY
2083 NORMANDY DRIVE DOOR 113 TO 134
NEW CUMBERLAND PA 17070-5002
US
FOR TRANSPORTATION SEE DLAD DLAD PROC NOTE C19. FOR FIRST DESTINATION TRANSPORTATION SEE DLAD PROC NOTE
C20 AND CONTRACT
FREIGHT SHIPPING ADDRESS:
W25G1U
W1A8 DLA DISTRIBUTION
DDSP NEW CUMBERLAND FACILITY
2083 NORMANDY DRIVE DOOR 113 TO 134
NEW CUMBERLAND PA 17070-5002
US
Need Ship Date:05/04/2027 Original Required Delivery Date:06/04/2027
DLA issues this document using the DoD authorized unit of issue, please refer to the following URL to determine the corresponding ANSI X12 unit of issue.
https://view.officeapps.live.com/op/view.aspx?src=https%3A%2F%2Fwww.dla.mil%2FPortals%2F104%2FDocuments% 2FDLMS%2FeApplications%2FLogDataAdmin%2FUnitofIssueandPurchaseUnit.xlsx&wdOrigin=BROWSELINK
SPE7L3-27-T-2329
SECTION B
PR: 7019025683 PRLI: 0002 CONT’D
CLIN PR PRLI UI QUANTITY UNIT PRICE TOTAL PRICE.
0002 7019025683 0002 EA 3.000
NSN/MATERIAL:2530015662564
DELIVERY (IN DAYS):0168
DELIVER FOB: ORIGIN
QTY VARIANCE: PLUS 0% MINUS 0%
INSPECTION POINT: DESTINATION
ACCEPTANCE POINT: DESTINATION
PREP FOR DELIVERY:
PKGING DATA MIL-STD-2073-1E
QUP:001 PRES MTHD:10 CLNG/DRY:1 PRESV MAT:00
WRAP MAT:CA CUSH/DUNN MAT:AD CUSH/DUNN THKNESS:F
UNIT CONT:F2 OPI:M
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
SPECIAL MARKING CODE:ZZ -ZZ Special Requirements
PALLETIZATION SHALL BE IN ACCORDANCE WITH RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
CUSHIONING MATERIAL: AD CONTRACTOR SHALL DETERMINE THE BEST ECONOMICAL AND PERFORMANCE APPLICATION OF BLOCKING AND BRACING SUPPLIES AND EQUIPMENT TO ENSURE THE PACKAGE DESIGN MEETS MIL-STD-2073 PACKAGE DESIGN PERFORMANCE AND VALIDATION REQUIREMENTS.
BLOCKING AND BRACING. ITEMS WHICH DO NOT COMPLETELY FILL THE SHIPPING CONTAINER SHALL BE BLOCKED, BRACED, ANCHORED, OR OTHERWISE IMMOBILIZED WITHIN THE CONTAINER. THE MATERIAL SELECTED FOR BLOCKING AND BRACING AND THE DESIGN AND APPLICATION OF THE BLOCKING AND BRACING SHALL BE COMPATIBLE WITH THE LOAD TO BE SUPPORTED AND THE SIZE, SHAPE, AND STRENGTH OF BEARING AREAS OF THE ITEM.
Coatings and barriers. Protection shall be provided for strippable compound coatings and for grease-proof, water-proof, or water vapor-proof barriers at points of contact with blocking, bracing, or projecting members of containers. Cushioning materials shall be applied to reduce the static pressure at points of contact to 30 pounds or less per square inch.
Surface abrasion and corrosion. When the surface of the item in contact with the blocking and bracing can be damaged by relative motion between the contacting surfaces or could become corroded as a result of such contact, the contacting surfaces shall be separated by a barrier material meeting protective surface corrosion requirements for wrapping, cushioning and dunnage materials shall be used in contact with unprotected surfaces susceptible to damage from corrosion or deterioration.
Wood and plywood. Wood or plywood may be used alone or in combination for blocking and bracing. Wood or plywood blocking and bracing members shall bear against only those parts of the packed item capable of withstanding the applied dynamic forces or shall bear against blocking pads or pressure strips that adequately distribute these forces. Wood or plywood blocking and bracing shall be designed to permit easy removal without damage to the item. Strengths of wood and plywood members may be calculated from information given in USDA Agricultural Handbook No. 72.
SPE7L3-27-T-2329
SECTION B
PR: 7019025683 PRLI: 0002 CONT’D
Wood. Wood used for blocking and bracing shall conform to ASTM-D6199. Once wood member of each size and type used in the blocking and bracing shall be tested for moisture content. Structural members [those subject to critical bending stresses) shall conform to class 1 of ASTM-D6199. All other blocking and bracing members shall conform to class 3. Whenever possible, wood blocks or braces shall be placed so that the load is applied against the end grain of the member. Ends of braces shall be socketed or fitted and secured into appropriate notches in load-bearing members.
Plywood. Plywood used for blocking and bracing shall conform to A-A-55057, group A, (grade 3-4, type II) or group B, (C-D, interior with exterior glue).
Nails and nailing. Nails shall conform to the requirements of specification ASTM-F1667. ASTM-F1667 that are not clinched shall be cement coated, etched, or mechanically deformed (helically or annularly threaded). Unclinched nails shall be as long as practicable without splitting the material, but not shorter than three times the thickness of the member holding the nail-head for ten penny nails and smaller, or not shorter than the thickness of the same member plus 1-1/2 inches for twelve penny nails and larger. Nails loaded in shear blocking and bracing joints need not be clinched. End grain nailing in solid wood or edge nailing in plywood shall not be permitted. Nails shall be driven through the thinner member into the thicker member wherever possible. Nails shall not be subject to withdrawal stresses. Nails shall be driven not closer to the end of a piece of lumber than the thickness of the piece and not closer to its side than one-half its thickness. There shall be at least two nails in each joint. Lateral loading of nails for blocking and bracing shall be in accordance with table 111.
Ends of blocks and braces shall not be fastened to a wood container by end-grain nailing, toe nailing, or similar methods but shall be fastened to a sturdy part of the container or held in place by parallel cleats or other side-grain nailing methods. Blocking and bracing shall be applied against areas of the item(s) that are of sufficient strength and rigidity to resist damage.
WOODEN CONTAINER SHALL INCLUDE SHEATHING ON ALL SIDES, ENDS, TOP AND BOTOOM OF THE SPECIFIED CONTAINER.
ZZ SPECIAL MARKING REQUIREMENTS: 02 ARROW UP OPEN THIS SIDE
REQUIRED: PER MIL-STD-129, SERIAL NUMBER SHALL BE MARKED ON THE UNIT, INTERMEDIATE<(>,<)> AND SHIPPING CONTAINERS.
MECHANICAL HANDLING IS REQUIRED.
PACKAGE DESIGN PERFORMANCE CRITERIA IS SAFE DELIVERY TO ULTIMATE USER.
IP025: PACKAGING, MARKING, AND SHIPPING OF HAZARDOUS MATERIALS
PKGING DATA MIL-STD-2073-1E
QUP:001 PRES MTHD:10 CLNG/DRY:1 PRESV MAT:00
WRAP MAT:CA CUSH/DUNN MAT:AD CUSH/DUNN THKNESS:F
UNIT CONT:F2 OPI:M
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
SPECIAL MARKING CODE:ZZ -ZZ Special Requirements
PALLETIZATION SHALL BE IN ACCORDANCE WITH RP001: DLA PACKAGING
SPE7L3-27-T-2329
SECTION B
PR: 7019025683 PRLI: 0002 CONT’D
REQUIREMENTS FOR PROCUREMENT
CUSHIONING MATERIAL: AD CONTRACTOR SHALL DETERMINE THE BEST ECONOMICAL
AND PERFORMANCE APPLICATION OF BLOCKING AND BRACING SUPPLIES AND
EQUIPMENT TO ENSURE THE PACKAGE DESIGN MEETS MIL-STD-2073 PACKAGE DESIGN
PERFORMANCE AND VALIDATION REQUIREMENTS.
BLOCKING AND BRACING. ITEMS WHICH DO NOT COMPLETELY FILL THE SHIPPING
CONTAINER SHALL BE BLOCKED, BRACED, ANCHORED, OR OTHERWISE IMMOBILIZED
WITHIN THE CONTAINER. THE MATERIAL SELECTED FOR BLOCKING AND BRACING AND
THE DESIGN AND APPLICATION OF THE BLOCKING AND BRACING SHALL BE
COMPATIBLE WITH THE LOAD TO BE SUPPORTED AND THE SIZE, SHAPE, AND
STRENGTH OF BEARING AREAS OF THE ITEM.
Coatings and barriers. Protection shall be provided for strippable compound coatings and for grease-proof, water-proof, or water vapor-proof barriers at points of contact with blocking, bracing, or projecting members of containers. Cushioning materials shall be applied to reduce the static pressure at points of contact to 30 pounds or less per square inch.
Surface abrasion and corrosion. When the surface of the item in contact with the blocking and bracing can be damaged by relative motion between the contacting surfaces or could become corroded as a result of such contact, the contacting surfaces shall be separated by a barrier material meeting protective surface corrosion requirements for wrapping, cushioning and dunnage materials shall be used in contact with unprotected surfaces susceptible to damage from corrosion or deterioration.
Wood and plywood. Wood or plywood may be used alone or in combination for blocking and bracing. Wood or plywood blocking and bracing members shall bear against only those parts of the packed item capable of withstanding the applied dynamic forces or shall bear against blocking pads or pressure strips that adequately distribute these forces. Wood or plywood blocking and bracing shall be designed to permit easy removal without damage to the item. Strengths of wood and plywood members may be calculated from information given in USDA Agricultural Handbook No. 72.
Wood. Wood used for blocking and bracing shall conform to ASTM-D6199. Once wood member of each size and type used in the blocking and bracing shall be tested for moisture content. Structural members [those subject to critical bending stresses) shall conform to class 1 of ASTM-D6199. All other blocking and bracing members shall conform to class 3. Whenever possible, wood blocks or braces shall be placed so that the load is applied against the end grain of the member. Ends of braces shall be socketed or fitted and secured into appropriate notches in load-bearing members.
Plywood. Plywood used for blocking and bracing shall conform to A-A-55057, group A, (grade 3-4, type II) or group B, (C-D, interior with exterior glue).
Nails and nailing. Nails shall conform to the requirements of specification ASTM-F1667. ASTM-F1667 that are not clinched shall be cement coated, etched, or mechanically deformed (helically or annularly threaded). Unclinched nails shall be as long as practicable without splitting the material, but not shorter than three times the thickness of the member holding the nail-head for ten penny nails and smaller, or not shorter than the thickness of the same member plus 1-1/2 inches for twelve penny nails and larger. Nails loaded in shear blocking and bracing joints need not be clinched. End grain nailing in solid wood or edge nailing in plywood shall not be permitted. Nails shall be driven through the thinner member into the thicker member wherever possible. Nails shall not be subject to withdrawal stresses. Nails shall be driven not closer to the end of a piece of lumber than the thickness of the piece and not closer to its side than one-half its thickness. There shall be at least two nails in each joint. Lateral loading of nails for
SPE7L3-27-T-2329
SECTION B
PR: 7019025683 PRLI: 0002 CONT’D
blocking and bracing shall be in accordance with table 111.
Ends of blocks and braces shall not be fastened to a wood container by end-grain nailing, toe nailing, or similar methods but shall be fastened to a sturdy part of the container or held in place by parallel cleats or other side-grain nailing methods. Blocking and bracing shall be applied against areas of the item(s) that are of sufficient strength and rigidity to resist damage.
WOODEN CONTAINER SHALL INCLUDE SHEATHING ON ALL SIDES, ENDS, TOP AND BOTOOM OF THE SPECIFIED CONTAINER.
ZZ SPECIAL MARKING REQUIREMENTS: 02 ARROW UP OPEN THIS SIDE
REQUIRED: PER MIL-STD-129, SERIAL NUMBER SHALL BE MARKED ON THE UNIT, INTERMEDIATE<(>,<)> AND SHIPPING CONTAINERS.
MECHANICAL HANDLING IS REQUIRED.
PACKAGE DESIGN PERFORMANCE CRITERIA IS SAFE DELIVERY TO ULTIMATE USER.
IP025: PACKAGING, MARKING, AND SHIPPING OF HAZARDOUS MATERIALS
PARCEL POST ADDRESS:
SW3215
DLA DISTRIBUTION BARSTOW
CENTRAL RECEIVING WHSE 7
REC OFFICER +1 (555) 000-0000
BARSTOW CA 92311-5014
US
FOR TRANSPORTATION SEE DLAD DLAD PROC NOTE C19. FOR FIRST DESTINATION TRANSPORTATION SEE DLAD PROC NOTE
C20 AND CONTRACT
FREIGHT SHIPPING ADDRESS:
SW3215
DLA DISTRIBUTION BARSTOW
CENTRAL RECEIVING WHSE 7
REC OFFICER +1 (555) 000-0000
BARSTOW CA 92311-5014
US
Need Ship Date:05/04/2027 Original Required Delivery Date:06/04/2027
SPE7L3-27-T-2329 NSN/Part Number: 2530-01-566-2564 Quantity: 1 EA Purchase Request: 7019025683QTY: 4 Delivery: 168 days ADO
Similar Contracts
Same NAICS industry code
More opportunities from Department Of Defense → DLA WEAPONS SUPPORT LAND SUPPLIER OPNS VEHICLE SPT
Same awarding agency
Earlier notices in this NAICS code
Posted before this notice, open and closed
Ready to Pursue This Opportunity?
Get AI-powered intelligence on this solicitation and the ones like it
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS
