This Solicitation opportunity from Illinois was posted on May 26, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

34.5-12.47 kV Power Transformer

Closed
26-124State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 335311
New
Federal
ISF DC Power
Solicitation # W9115126QA063
Solicitation W9115126QA063 is a Firm-Fixed-Price supply and installation contract issued by the W6QM MICC-FDO Fort Hood for the White Sands Missile Range Information Systems Facility. The project requires the procurement and installation of the VERTIV NetSure DC Power System, a modular and scalable -48 VDC infrastructure supporting power requirements from 1,000 to 16,000 amps. This specific brand is mandated to ensure compatibility with the USACE Basis of Design and existing AC/DC electrical infrastructure, as substitutions would necessitate costly redesigns of the facility layout and data center containment systems. The scope includes the delivery of NetSure 8200 Power Systems, combination bays, AC cabinets, and related components, as well as the mounting of equipment to the floor and the performance of internal operation test and turn-up. The contract is a total small business set-aside under NAICS code 335311. Deliveries are specified as F.o.b. Destination to the White Sands Missile Range in New Mexico, with a final delivery deadline of November 16, 2026. Offerors must be Vertiv or a verified authorized vendor and are required to use the Wide Area WorkFlow system for electronic invoicing. Evaluation of offers will consider Buy American and Balance of Payments policies. Key administrative requirements include compliance with DFARS cybersecurity and telecommunications restrictions, as well as the submission of CAGE codes and Unique Entity Identifiers.
W6QM Micc-Fdo Ft Hood

POSTED

1 day ago

DEADLINE

in 10 days

AI Contract Overview

Show more

The contract involves the design, manufacture, supply, factory testing, delivery, installation, and commissioning supervision of two 34.5 – 12.47 kV power transformers for the Chicago Substation located in Naperville, Illinois. The vendor is responsible for placing the transformers on the company’s foundation, dressing them out, filling them with oil, and conducting thorough testing to ensure operational readiness. The transformers must include all necessary accessories to guarantee safe, efficient, and convenient operation as specified, and must be manufactured within the United States. This solicitation is issued by the Public Utilities (Electric) department under the Illinois agency, with the project centered in Naperville. The solicitation number is 26-124, with proposals due by June 22, 2026. Key contacts for the project include Carla Soria, a Technical Specialist in Electric Utilities, and Shanel Gayle, the Procurement Officer. The contract emphasizes compliance with detailed specifications and local manufacturing requirements, aiming to enhance the electrical infrastructure at the specified substation.

General Info

Design, manufacture, supply, install, and test two 34.5-12.47 kV transformers in Naperville, USA.

Agency

Illinois → Public Utilities (Electric) | DPU-EView Agency

NAICS

335311 - Power, Distribution, and Specialty Transformer ManufacturingView NAICS

Place of Performance

IL, USA

Set-Aside

NONE

Documents

(11)

Scope of Work (SOW) Guide Revised 22 December 2025

PDF11 pagessow

Bid 26-124 34.5-12.47 kV Power Transformer

PDFrfq

City of Naperville Contractor Safety Orientation Checklist

PDF2 pagessafety-orientation-checklist

34.5-12.47 kV Power Transformer Specification for City of Naperville Chicago Substation

DOCXsow

Bid 26-124 34.5-12.47 kV Power Transformer

PDFrfq

34.5-12.47 kV Power Transformer Specification

DOCXspecifications

Technical Data for 34.5-12.47 kV Power Transformer March 2026

XLSspecifications

26-XXX New Substation Transformer Bid Worksheet

XLSXbid-sheet

34.5-12.47 kV Power Transformer Specification Rev1

DOCXspecifications

Certificate of Liability Insurance

DOCX1 pageinsurance-certificate

Technical Data for 34.5-12.47 kV Power Transformer for Naperville Substation

XLSsow

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyIllinois → Public Utilities (Electric) | DPU-E
Contacts2 people available
OfficeNaperville, IL, 60540, USA
Organization / Agency
Illinois → Public Utilities (Electric) | DPU-E
View Agency Profile
Office AddressNaperville, IL, 60540, USA
Contacts
Carla SoriaTechnical Specialist Electric Utilities
Shanel GayleProcurement Officer

Interested Companies (20)

Show more
WESCO Distribution
Pittsburgh, PA
Statewide Eng. Corp. dba SEC Electrical Equipment Sale
LX International (America)
Orange, CA

See All 20 Interested Companies

Start a free trial to view all interested companies, their contact details, and full contractor profiles.

Start Free Trial

Full Description

Show more
The Vendor shall design, manufacture, supply, factory test, deliver to the Chicago Substation in Naperville, Illinois, place on the COMPANY's foundation, dress out, fill with oil, test, and provide installation supervision for two (2) 34.5 – 12.47 kV Power Transformers in accordance with this specification. The Power Transformer shall be complete with all accessories required for the safe, efficient, and convenient operation of the transformer within the scope of this specification whether or not such items are specifically referred to in this specification. The transformers shall be manufactured in the United States.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS