Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Veterans Affairs was posted on January 19, 2018. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

36--Grand Junction dryer

Awarded
VA797H17R0025Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

Contract Value

$288,371

NAICS

333318 - Other Commercial and Service Industry Machinery Manufacturing

Place of Performance

IL

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

2 updates
PhaseAwarded
Posted

Sources Sought

Type Changed

Sources Sought → Presolicitation

Notice updated

Response deadline added: Sep 15, 2017. The notice description changed.

Notice updated

Notice details unchanged. Attachments may have changed.

Type Changed

Presolicitation → Solicitation

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → Nac Federal Supply Schedule (36F797)
ContactsNo contacts available
OfficeHINES, IL, 60141, USA
Office AddressHINES, IL, 60141, USA
ContactsNo contact information available

Full Description

Show more
THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), National Acquisition Center (NAC), HTME Contracts is requesting procurement information for a commercial laundry project. The National Contract Service is in search of SDVOSB and VOSB organizations that are capable of servicing the Department of Veterans Affairs Grand Junction, CO, Medical Center need to procure the following commercial laundry equipment item(s): 200/300 POUND GAS HEATED DRYING AND CONDITIONING TUMBLER WITH EXTERNAL LINT COLLECTION For more detailed information please review the attached draft Technical Specifications. RESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION: Company Name, Address, Size Standard, DUNS #, Cage Code Point of Contact name, phone number, and email address NAICS Code 333318 and Small Business Size Standard 1000 employee (to determine business size standard) Commercial Laundry Equipment Price List Capability Statement Proof of qualifications (provide a list of 3 organizations that you have supplied with commercial laundry equipment) Provide proof of past performance (provide 2 commercial laundry contracts you have installed in the last 5 years) Only SDVOSB and VOSB offerors are invited to respond to this Sources Sought Notice via email to Donnie Reeves at contact@example.gov, along with any other questions or concerns, no later than 07/13/2017. Disclaimer and Important Notes: This Sources Sought Notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. The Government will treat any information received as proprietary and will not share such information with other companies. Any organization responding to this Sources Sought Notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this announcement. There is no solicitation available at this time. ITEM #1 200/300 POUND GAS HEATED DRYING AND CONDITIONING TUMBLER WITH EXTERNAL LINT COLLECTION: Furnish and install one (1) each 200/300-pound non-production gas heated dryer with external to the machine lint collection. The dryer shall have color touch screen controls & information systems that incorporate automatic/manual machine operation, self-testing, fault display and built-in diagnostics and capable of being programmed for dryer loads. The 200/300-pound dryer shall be non-pass thru with 2-way tilting for loading and unloading. The cylinder size (rated capacity) shall be 200/300 pounds, based upon a maximum 2.96 pounds per cubic foot of cylinder space. Dryer shall be capable of being sling loaded from existing monorail, if any modification is needed for the spur, it is up to the contractor. The types of textiles processed are normal hospital linen, sheets, pillowcases, bath blankets, thermal blankets, towels, wash cloths, patients clothing, uniforms and surgical linens. Any existing roof penetrations will be removed or capped in compliance with State Roofing Codes. 1. Unit shall be a drying and conditioning tumbler, laundry, commercial type, 2. Commercial preservation, packaging and packing against damage required. 3. Electrical characteristics - 2080 volts, 3 phase, 60 cycles. 4. Dryer shall be microprocessor/color touch screen controls & information systems that incorporate automatic/manual machine operation, self-testing, fault display and built-in diagnostics and capable of being programmed for dryer loads and capable of programming each category of textiles. 5. Tumbler shall be provided with removable cylinder panels and provided with protective non-stick cylinder coating providing 3000-production hour guarantee. 6. Reversing and non-reversing required. 7. Tumbler shall be gas heated. 8. A light to designate that tumbler is in operation is required. 9. Dryer shall be equipped with heavy duty drive and support wheels. 10. Dryer shall be equipped with a microprocessor time and temperature. 11. The tumbler shall be exhausted to the outside atmosphere. All ductwork shall be galvanized steel and new to the outside of the building. - 12. A blow-down device will be installed within the dryer location. A minimum 1 each) and shall be capable of reaching around the dryer. This device shall include: - a. A gauged air pressure regulator, with quick disconnect, capable of regulating air pressure from 0 PSI to 30 PSI. - b. Minimum 50 foot length of heavy duty, reinforced non-kink air hose on an automatic retractable reel. c. Trigger operated air nozzle with any necessary extensions for reaching hard to reach areas. d. Locations of the blow down device(s) shall be depicted on drawings. 13. Tumbler's air intake and exhaust air shall be derived and directed to and from the outside of the laundry building atmosphere. 14. Drying and conditioning tumblers shall have a beacon rotary LED light (colored AMBER) identifying end of drying cycle for the hearing impaired. Dryer shall also have an audible alarm to indicate when drying cycle has ended. 15. Dryer shall be equipped with excess temperature sprinkler protection. 16. A flow alarm valve shall be installed in the fire suppression system and connected to a rotary beacon LED light (colored RED) and audible alarm, to be located on the dryer, to indicate if a fire exists in the dryer. The dryers shall also be connected to the building fire alarm system to alert authorities of a fire in the dryers. The dryer(s) shall be connected to a dedicated domestic water pipe with a tamper proof valve. A backflow preventer shall be installed within six (6) inches of the domestic water main that is connected to the dedicated domestic water pipe. A maintenance valve shall be installed on the branch domestic water line before entry in to the dryers and drain into a floor drain if available for maintenance of the fire suppression system. 17. Normal stop push buttons and emergency stop buttons shall be colored red. An illuminating (when activated) emergency stop button with legends shall be installed on the drying conditioning tumblers. Yellow background with legends shall also be installed behind the emergency stop button. 18. Drying conditioning tumbler shall be equipped with lockout/tag out instructions for servicing and maintenance of equipment. Instructions shall be permanently attached to the machine. Tags and locks shall be provided by the successful offeror. 19. Air intake and exhaust ductwork shall have easily accessible hinged access panels installed for easy clean-out and manual firefighting. Exhaust ductwork shall be insulated and wrapped with white textured aluminum jacket covering and have identification and flow markings. Air intake will be insulated and wrapped in PVC plastic and have identification and flow markings. 20. All ductwork located inside the building shall be sealed identified and have directional flow markings installed. - 21. Dryers shall be designed/equipped to prevent placement of objects under the tilting portion of the dryer. 22. Dryer shall be capable of sling loaded from existing monorail, any modification to spur will be the responsibility of the contractor. - 23. Dryers shall be equipped with a manual override device to permit opening of the dryer door in case of a power failure. 24. Dryers shall be equipped with excess temperature cutout switches or relays and operating temperature controls. 25. Ductwork configuration shall meet the manufacturers recommended size and be cylindrical in design. 26. Tumbler shall have independent electronic ignition. 27. Include lock-out and tag-out requirements for equipment offered. Lock-out / tag-out devices shall be supplied by the successful offeror. 28. Provide 4-Plex receptacle for each equipment location for mechanics use. 29 An hour meter shall be installed on the dryer that will show actual hours of run time of the dryers. 30 An I-beam with a ½ ton hoist or other device shall be supplied and installed to remove dryer motors for maintenance.

More opportunities from Department Of Veterans Affairs → Nac Federal Supply Schedule (36F797)

Same awarding agency

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS