Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity was posted on November 3, 2017. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

41--502-18-1-5023-0002 - Air handle unit with cold/hot water coils - VA256-17-AP-12113

Awarded
VA25617Q1563Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334512
New
DIBBS
SWITCH, THERMOSTATIC
Solicitation # SPE7M8-27-T-0480
Solicitation SPE7M8-27-T-0480 is a request for quotations issued by the DLA Weapons Support Electrical Devices Division for the procurement of six thermostatic switches, identified by NSN 5930016019386 and Texas Instruments part number 11041-32-268. This is a restricted source item requiring engineering source approval by the government design control activity and is designated as a critical application item. The delivery is set for 235 days after the order is placed, with a need ship date of July 3, 2027, and a final required delivery date of October 31, 2027. Shipping is FOB Origin, with the destination for inspection and acceptance being the DLA Distribution DDSP New Cumberland Facility in Pennsylvania. The contract mandates strict adherence to the DLA Master List of Technical and Quality Requirements, including specific protocols for packaging, configuration change management, and the removal of government identification from non-accepted supplies. Packaging must comply with MIL-STD-129 and RP001, with hazardous materials requiring adherence to FED-STD-313 and TQ requirement IP025. Additionally, the contract prohibits the intentional addition of mercury or mercury-containing compounds except where functionally required. Administrative requirements include the use of the Wide Area WorkFlow system for invoicing and compliance with the Buy American and Balance of Payments Program, as well as various FAR and DFARS clauses regarding cybersecurity, safeguarding covered defense information, and the prohibition of covered defense telecommunications equipment.
DLA WEAPONS SUPPORT ELECTRICAL DEVICES DIV

POSTED

1 day ago

DEADLINE

in 11 days

General Info

Agency

N/A

Contract Value

$55,251

NAICS

334512 - Automatic Environmental Control Manufacturing for Residential, Commercial, and Appliance Use

Place of Performance

Not specified

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

3 updates
PhaseAwarded
Posted

Combined Synopsis

Notice updated

Response deadline changed from Oct 5, 2017 to Oct 13, 2017. The notice description changed.

Notice updated

The notice description changed.

Notice updated

Response deadline changed from Oct 13, 2017 to Oct 20, 2017. The notice description changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
ContactsNo contacts available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
SCOPE OF WORK REPLACE TB HVAC UNIT, BUILDING NO. 7 SC1. Work will be performed in building No. 7 in a functioning Medical facility and the Contractor will need to conduct himself accordingly. Building 7 is a multi-story building with large mechanical penthouses. Schedule all work with the Resident Engineer a minimum of two weeks in advance to enable Engineering to make any necessary arrangements. Confine all work in existing areas to the areas and space involved. SC2. Parking shall be limited to established parking lots. Contractors and personnel are not allowed on the grass area unless specifically authorized by the Resident Engineer. U.S. District Court Violations Notices shall be issued for parking violations. The contractor and all employees shall comply with all applicable VA Medical Center fire, safety and traffic regulations. SC3. The Contractor is to field verify all dimensions and existing conditions. SC4. All work is to be performed in accordance with all OSHA, EPA, VA, Federal, State, and local codes and regulations. SC5. No roadway, drainage ditch, pedestrian walk way, or any other service, utility or access to any of the above is to be blocked or rendered unusable for any length of time during this project unless previously approved by the Resident Engineer. SC6. Complete Bid Item 1 in 90 calendar days after award of the contract. SC7. All work, materials, storage of materials and equipment, repair procedures and unforeseen problems or circumstances are to be coordinated with the Resident Engineer. SC8. Work on this project shall not begin until authorized by the Contracting Officer. SC9. The Title Resident Engineer shall refer to the Contracting Officer s Technical Representative located at the Department of Veterans Affairs Medical Center: Engineering Service, at +1 (555) 000-0000. SC10. The scope of the project is to includes, but is not limited to the following: General Project Description The Scope of the project is to replace the TB Air Handling Unit (AHU) in Building 7 Main Hospital. The project includes removal of the existing TB Air Handling Unit and replacing with a new Air Handling Unit, and all associated components including but not limited to air handling unit, duct work, piping, reinsulating of duct work/piping and all controls required for complete working systems. New DDC controls shall be installed to replace the existing hybrid pneumatic-DDC controls. I. MECHANICAL: A. Contractor shall provide all labor, materials, and equipment necessary to replace the existing TB Air Handling Unit(AHU) located in the penthouse on the roof of building 7- Main Hospital with a Daikin Model CAH008GDAC 208volt AHU or equal unit. Include a drain pan piped to the closest drain. Repair or replace insulation of duct work and piping of the unit. Prior to start-up of the unit, strainers must be cleaned and water flow balanced. Equal unit must have the following salient characteristics: 3000 cfm/ steam heating coil 103485btu/hr with 1.5 in pipe connection Chilled water coil 278405 btu/hr with 2 in. pipe connection pleated filter section work light inside of unit NOTE: Existing unit is 87 in. long x 42 in. wide x 38 tall I. CONTROLS: A. New DDC controls will be provided and installed by the contractor and shall be monitored at Central Plant ECC, and shall be connected back to the existing FMS for management, control and monitoring. Existing pneumatic system shall be removed. Includes replacement of existing control valves. II. ELECTRICAL: Provide and install a new VFD for the new AHU. Existing building electrical systems shall be coordinated and modified as required to accommodate new mechanical system components. III. ARCHITECTURAL: Existing architectural systems shall be coordinated and modified as required to accommodate new mechanical system components, duct and piping floor penetrations, modification all to suit new Air Handling Unit layout. IV. STRUCTURAL: Existing structural systems are in acceptable condition. Existing structure shall remain intact, except as required to install new duct or piping penetrations. V. FIRE PROTECTION: Fire Protection work in this project will be related to modifications that will result from installation of new HVAC systems ductwork, piping, etc. VI. PLUMBING AND PIPE FITTING: Plumbing work in this project will be related to modifications that will result from the new air handling unit. Perform and safeguard hot work operations in accordance with NFPA 241 and NFPA 51B. Coordinate with Resident Engineer and/or Facility Safety Officer and Facility Fire Department. Obtain permits from Facility Fire Department at least 1 hour in advance of begin any hot work. - - - E N D - - -

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS