Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on April 11, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

4110--36C25525Q0304, MOBILE BLOOD_PLASMA REFRIGERATORS POWER BACKUP l STL

Closed
36C25525Q0304Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 333415
New
Federal
4120--SPECIAL Duplex Strainer - MPLS
Solicitation # 36C26327Q0054
Solicitation 36C26327Q0054 is a special, accelerated request for quotes issued by the Department of Veterans Affairs Network Contracting Office 23 for the supply and delivery of a brand name or equal Keckley duplex strainer and gasket for the Minneapolis VA Health Care System. This is a total small business set-aside conducted under FAR Part 12 for commercial products, utilizing NAICS code 333415. The government intends to award one firm fixed price contract based on the lowest price technically acceptable process. The required supplies include one 20 inch Keckley Basket Strainer (Part No. 2RFFD-FCS125P34-920) and one O-ring gasket (Part No. FT-920-Gasket), both of which must be new and unused. Technical specifications require a carbon steel shell (ASTM A 53 Grade B), a 304 stainless steel basket with 1/8 inch perforations, and a modular design where individual sections do not exceed 2,000 pounds. The period of performance is from November 9, 2026, to March 15, 2027, with all items delivered FOB Destination to Minneapolis, Minnesota, by the end date. Prospective offerors must be registered in the System for Award Management and the SBA Small Business Search. Quotes are due by 10:00 AM on October 30, 2026, and must be submitted via email to Robert Bennett. Submissions must be divided into two volumes: Volume I for pricing and administrative compliance (including a signed SF 1449 and UEI number), and Volume II for technical qualifications, including a narrative of the offeror's ability to complete the work and subcontractor details. Evaluation will be based on technical acceptability and a fair and reasonable total price.
Network Contract Office 23 (36C263)

POSTED

1 day ago

DEADLINE

in 9 days

General Info

NAICS

333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

Place of Performance

St. Louis VAMC-Jefferson Barracks 1 Jefferson Barracks Dr., St. Louis, KS, 63125-1621, USA

Set-Aside

NONE

Documents

1

36C25525Q0304.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)
Contacts1 person available
OfficeLEAVENWORTH, KS, 66048, USA
Office AddressLEAVENWORTH, KS, 66048, USA
Contacts
Israel ArmentaContract Specialist

Full Description

Show more
This is a SOURCES SOUGHT announcement only. It is neither a solicitation announcement nor a request for proposal or quote and does not obligate the Government to award a contract. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research, to make appropriate acquisition decisions, and to gain knowledge of potential qualified businesses capable of providing the following: Mobile Plasma Refrigerators for St Louis VAMC *** See Statement of Requirement below for details *** If this is within your capability, please respond with the information below: Company Name Address Point of Contact Phone, Fax, and Email UEI number GSA Contract (as applicable) Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications to be considered for award. In addition, FAR 4.11 states that prospective contractors shall be registered in the System for Award Management (www.SAM.gov) database. All Service-Disabled Veteran Owned Small Businesses (SDVOSB) and Veteran Owned Small Businesses (VOSB) shall be verified in VetBiz at www.vip.vetbiz.gov. Point of Contact for this Sources Sought is: heather.strouhal@va.gov (913) 946 1165 Israel Armenta Israel.armenta@va.gov (913)758-9942 Department of Veterans Affairs Network Contracting Office -15 3450 S. 4th Street Trafficway Leavenworth, KS. 66048. STATEMENT OF REQUIREMENT HEMOROAM 25XL Mobile Blood and Plasma Refrigerators power Backup project FOR EMERGENCY MANAGEMENT EMERGENCY POWER OUTAGE PROJECT ROEMER UNITS VA ST. LOUIS HEALTHCARE SYSTEM CBOCs, Annexes, and HRC Direct Support EMPI Provision BACKGROUND A need to directly support VA St. Louis Healthcare System (VASTLHCS) Community Based Outreach Clinics (CBOCS), Annexes, and the HRC, collectively known as outlier clinics , during electrical power outages exists, which are critical recurring concerns. Lightning and power outages were rated as the first and fourth hazard respectively on the VASTLHCS hazard vulnerability assessment. Contractor error, aging infrastructure, and severe weather contribute to the susceptibility to continual power outages. These reoccurring all-hazard incidents were responsible for over $50,000 in vaccine product spoiling in an unpowered refrigerator which impeded patient care by disrupting point of dispensing operations. The VASTLHCS requires a 102-hour cold chain management capability to preserve pharmaceutical product and specimens on site when staff is concerned with the safety of the patients. Power outage in rural outpatient locations or over weekends need approximately 54 hours of battery backup to allow the hospital incident command adequate time to respond. The cold storage cart provides an additional 48-hours capability to secure and transport the product on extended outages. The delivery by date is May 31, 2025. Objectives: The Roemer HEMOROAM BBS100 25-liter portable battery powered medical refrigerator provides 48 hours of cold storage for patient care products from specimen draws to point of dispensing. The mobility allows for the transport of pharmaceutical products and battery-operated refrigerator during emergency power outages. The apparatus is designed for long distance reliable cold chain management for rural outpatient clinics. This will coincide with the existing emergency power support provided to John Cochran and Jefferson Barracks divisions, per Veteran s Health Administration (VHA) Directive 1028 (Facility Electric Power Systems). Currently these outlier clinics are not in compliance, are neglected and this procurement will augment the Environmental Monitoring Program MCP 138-042 (Temptrak program) monitored by Facility Engineering Services (FES) to safeguard these medications, specimens, and vaccines. This will further address critical supplies and utility management issues in the Emergency Operations Plan (EOP), which will include needed support of the outlier clinics EOP December 14, 2022. Deliverables Vendor shall provide the following products and quantities: Vendor Shall provide to VASTLHCS at total of two (2) Roemer HEMOROAM 25XL mobile units, model number HR-25XL (48 Hours refrigerator) mobile cold storage refrigerator, meets or exceeds CDC requirement for cold chain management in accordance with CDC Operational Readiness Review. This unit or similar in capabilities. All units to have unique Serial numbers, identifier numbers, visible on the exterior of each unit, without need to remove any plate or component. Provide Equipment safety, electrical/wiring, installation, maintenance and warranty instructions and manuals to include Lock-out/tag-out energy control procedures as determined by 29 CFR 1910.147, 29 CFR 1910 Subpart S, and other industry guidance as applicable. Technical Requirements; The VASTLHCS requires a cold chain management capability of up to 102-hour to preserve pharmaceutical product and specimens on site in a mobile unit. Power: 110 Volt Battery Run time minimum: 80 hours to 102 Hours BBS 100 Area: less than 24 (L) x 20 (W) / 480 inches2 or less Temperature Setting: Set Point 4.0 C +/- 2.0 C or similar Refrigerated Payload Capacity min: 15-18 units of 300 ML RBC and 15-18 units of 300ML Plasma Unit Weight: 150 pounds or less Mobility: Mounted on Casters for ease of transport Handles: for pushing/pulling for ease of transport Lockable: Yes, for security of critical medical supplies OEM warranty Delivery to: VA St Louis Health Care System 1 Jefferson Barracks Drive - Warehouse Building 57 St. Louis, Mo 63125 Deliver Monday Friday 07:30 AM -15:00 PM, Excluding Federal Holidays New Year s Day Martin Luther King, Jr. Day President s Day Memorial Day Juneteenth Day Independence Day Independence Day Labor Day Columbus Day Veterans Day Thanksgiving Day Christmas Day

More opportunities from Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)

Same awarding agency

NAICS: 811210
New
Federal
Wound Vac Cleaning Maintenance Service | St. Louis VAMC
Solicitation # 36C25527Q0033
The Department of Veterans Affairs, Network Contracting Office 15, has issued a Sources Sought Notice under solicitation number 36C25527Q0033 to identify qualified vendors for the cleaning and maintenance of eighteen VA-owned 3M/KCI ULTRA Wound V.A.C. units at the St. Louis VAMC, covering both the John Cochran and Jefferson Barracks divisions. The scope of work requires a KCI authorized professional to perform on-site asset management, including validating units in use and collecting them within 48 hours of patient use. Maintenance services, including cleaning, disinfection, inspection, and both preventative and corrective repairs, must be performed off-site using OEM-approved parts in accordance with manufacturer requirements. All equipment returned to the facility must feature an HTM/Biomedical Inspection Label detailing the initial test date and the next preventative maintenance due date. The anticipated contract structure consists of a one-year base period with four optional extension years. To be considered, prospective contractors must be registered in the System for Award Management and provide a comprehensive response by November 4, 2026. Required submissions include a capability statement, an OEM authorized service provider letter, product brochures with specifications, and evidence of past performance consisting of at least three similar contracts completed within the last two years for large medical centers. Vendors are responsible for all associated travel costs and must maintain all necessary state and federal licenses and certifications.
Electronic and Precision Equipment Repair and Maintenance

POSTED

about 10 hours ago

DEADLINE

in 14 days
View Details
NAICS: 541330
New
Federal
C1AZ--657A4-26-125 Conduct Roof Deck Assessment Building 8 ME FY27 NRM
Solicitation # 36C25526R0183
The Department of Veterans Affairs, Network Contracting Office 15, is seeking qualifications from Service-Disabled Veteran-Owned Small Business (SDVOSB) architectural and engineering firms to conduct a structural assessment of the concrete roof deck and supporting welded steel bar joists at Building 8 of the John J. Pershing VA Medical Center in Poplar Bluff, Missouri. This procurement is conducted under the Brooks Act and NAICS code 541330. The scope of work involves performing visual inspections to map cracks and water infiltration, conducting concrete evaluations using hammer sounding and non-destructive scanning such as Ground Penetrating Radar, and assessing steel bar joists for corrosion and section loss to recommend necessary repairs for life-safety and long-term performance. Interested firms must submit a Standard Form 330 qualification package, not exceeding 65 pages, by November 4, 2026, at 2:00 PM CT. Evaluation criteria include the qualifications of key personnel, where Designers of Record must be professionally registered and resumes must highlight three to five relevant projects completed within the last ten years. The government will accept relevant assessment projects even if they did not result in construction. Additionally, offerors must provide five completed relevant project past performance documents and data on five recently completed construction projects to evaluate estimating effectiveness. Awarded contractors must comply with E-Verify and VA limitations on subcontracting.
Engineering Services

POSTED

about 10 hours ago

DEADLINE

in 14 days
View Details
NAICS: 811210
New
Federal
J061--Uninterruptible Power Supply St. Louis VA Medical Center
Solicitation # 36C25526Q0678
Solicitation 36C25526Q0678 is a firm-fixed-price, Indefinite Delivery Indefinite Quantity (IDIQ) contract issued by the Department of Veterans Affairs, Network Contracting Office 15. The contract requires comprehensive preventive maintenance, annual inspections, emergency services, and battery replacements for Uninterruptible Power Supply (UPS) units and batteries at the John Cochran and Jefferson Barracks VA Medical Centers in St. Louis, Missouri. The period of performance is five years, with a contract ceiling of 215,000 dollars and a guaranteed minimum of 43,000 dollars. While initially a small business set-aside, Amendment 0003 transitioned the solicitation to unrestricted competition. Award will be based on the Lowest Price Technically Acceptable (LPTA) process, where quotes are rated as either technically acceptable or unacceptable based on their ability to meet the Performance Work Statement and specifications. To be considered responsive, offerors must provide a completed price schedule, evidence of relevant past performance, and Original Equipment Manufacturer (OEM) authorization letters for each OEM represented in the PWS. Technicians must be certified in OSHA 1910 Subpart S and NFPA 70E safety standards. Following several amendments, the final quote submission deadline is October 28, 2026, with an optional site visit scheduled for October 22, 2026.
Electronic and Precision Equipment Repair and Maintenance

POSTED

1 day ago

DEADLINE

in 7 days
View Details
NAICS: 541519
New
Federal
NEXODOSE DOSE MONITOR
Solicitation # 36C25527Q0017
The Department of Veterans Affairs Network Contracting Office 15 is conducting market research through a Sources Sought announcement to identify qualified businesses capable of providing software maintenance, support, and interface services for the DoseMonitor/Nexodose radiation dose tracking platform. This requirement supports clinical safety and regulatory compliance for VA medical facilities across Kansas and Missouri, including sites in Topeka, Leavenworth, Kansas City, St. Louis, Columbia, and Poplar Bluff. The scope of work includes annual maintenance and support for the DoseMonitor/Nexodose application and outbound API/HL7 interfaces, as well as the one-time installation and ongoing support of bi-directional HL7 interfaces with the Oracle Health/Cerner electronic health record system in both production and test environments. The anticipated period of performance consists of a base year from February 1, 2027, to January 31, 2028, with one option year extending to January 31, 2029. Work will be performed primarily remotely, though on-site support may be required for installation and troubleshooting. Contractors must adhere to VA Handbook 6500, HIPAA privacy rules, and HL7 v2.x messaging standards. Interested firms must be registered in SAM.gov and provide a capability statement, product brochures, and an authorized service provider letter from the OEM. Responses should be submitted to Betty Flores at veronica.flores@va.gov by October 29, 2026.
Other Computer Related Services

POSTED

2 days ago

DEADLINE

in 8 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS