Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity was posted on September 8, 2005. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

42 -- Evacuation Smoke Hood

Awarded
SALMEC05Q0159Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 922160
SLED
2026 Volunteer Fire Capacity Grant
Solicitation # 2139681
The New York State Department of Environmental Conservation is administering the 2026 Volunteer Fire Capacity Grant Program, funded by a federal appropriation of 857,629 dollars. This program provides matching grants to eligible rural fire departments for the purchase of wildland firefighting suppression supplies. To be eligible, departments must be comprised of at least 80 percent volunteer personnel and serve a rural area, defined as a town or village with a population of 10,000 or less based on the 2020 Census. Selected departments can receive a maximum award of 3,500 dollars, which must be matched 50/50 by the recipient. Grant funds must be used for items directly related to wildland firefighting that benefit the local rural community, with a restriction that no individual item exceeds 9,999 dollars. Selection is based on the department's funding history over the previous five years, whether it is a newly formed establishment, and the presence of a Native American community within its jurisdiction. The program operates under federal guidelines from the US Forest Service and the Cooperative Forestry Assistance Act of 1978. Applications are accepted through December 30, 2026. This solicitation does not have specific goals for Service-Disabled Veteran-Owned, Minority, Women, or Disadvantaged Business Enterprises. All inquiries and applications are managed by the Volunteer Fire Capacity Grant Coordinator within the Division of Forest Protection.
NYS Department of Environmental Conservation

POSTED

8 days ago

DEADLINE

in 2 months

AI Contract Overview

Show more

Solicitation SALMEC05Q0159 outlines the requirements for the procurement of evacuation smoke hoods equivalent to the EVAC-U8 model. Each unit must provide up to 15 minutes of protection against combustion products, including carbon monoxide, utilizing a positive pressure valve system to prevent the inhalation of toxic gases and exhaled air. The equipment must feature a large opening for all head sizes, flame retardant draw straps, and a photoluminous disc canister containing a chemical catalytic filter, a desiccant, and an electrostatic charged particle filter. Technical specifications require the unit to weigh approximately 11 ounces with canister dimensions of 5.3 inches in length and 2.7 inches in diameter. Every unit must be individually boxed, include a five year warranty, and feature a stamped serial number and expiration date on the canister. Delivery logistics are strictly defined, requiring a lift gate truck for drop off at the 17th street entrance between 8 AM and 2 PM, Monday through Thursday.

General Info

Agency

N/A

Contract Value

$47,250

NAICS

922160 - Fire Protection

Place of Performance

WA, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

1 update
PhaseAwarded
Posted

Presolicitation

Notice updated

The notice description changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts2 people available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts
Denise A WilliamsProcurement Technician

Full Description

Show more
Evacuation "Smoke Hood" : Unit must be equal to the "EVAC-U8" smoke hood that provides up to 15 minutes of protection against products of combustion, including carbon monoxide (CO). The hood must have a large opening that fits all head sizes and have flame retardant draw straps to secure the hood around the neck. Additionally it must have a valve system that prevents re-breathing of exhaled air and it must produce a positive pressure that keeps toxic gases from entering the hood. The hood must be attached to a Photoluminous disc cannister with an air purifying chemical catalytic filter that converts carbon monoxide to carbon dioxide, a desiccant that absorbs moisture, and an electrostatic charged particle filter. Total unit weight should be approximately 11 ounces and the size of the cannister unit should be 5.3" L X 2.7"in diameter. Each unit must come individually boxed with a 5 year warranty and must have an expiration date and serial number stamped on the cannister. NOTE TO VENDOR: Notify freight forwarder that delivery must be at the 17th street entrance between the hours of 8:AM and 2 PM Monday through Thursday. A lift gate truck is required for delivery due to no loading dock at drop off location.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS