4673-24-R City of St. Petersburg

Awarded
State & Local
Solicitation #
H1077

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

Under solicitation H1077, the City of St. Petersburg is implementing a Hazard Mitigation Grant Program project to install a redundant backup power system at the Fleet Management Facility located at 1800 7th Avenue North. The project involves the installation of a permanent 600 kW diesel-fueled emergency generator, or an appropriately sized alternative determined by engineering specifications, along with an automatic transfer switch, enclosure, supply diesel tank, and all necessary electrical connections. This infrastructure is critical for ensuring the continuity of fueling operations for police and fire vehicles during and after emergency storm events. The project is funded by a grant from the Florida Division of Emergency Management totaling 505,523.96 dollars, with a performance period spanning from May 14, 2024, to May 31, 2027. To ensure resilience, all electrical components and the generator must be protected against a 500-year flood event and comply with National Flood Insurance Program requirements and ASCE 7 wind standards. All work must be performed in strict accordance with Federal, State, and Local rules and regulations, including National Electrical Code working clearance requirements.

General Info

St. Petersburg will install a backup generator for emergency vehicle fueling by 2027.

Contract Value

$505,523.96

NAICS

N/A

Place of Performance

FL, USA

Set-Aside

NONE

Award Issued Date

Contract End Date

May 31, 2027

Documents

1
PDF, High priority: read this firstcontract-document
High

Read the document

Every page of every file, in your free workspace.

Read the document

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

PhaseAwarded
Posted

Award Notice

Awarded

Contract was awarded

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyFlorida → Executive Office Of The Governor
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
As a Hazard Mitigation Grant Program (HMGP) project, the Sub-Recipient shall provide backup power to the Fleet Management Facility located at 1800 7th Avenue North, St. Petersburg, Florida 33713. Coordinates: (27.778789, -82.658364). The HMGP project shall provide protection by installing one (1) permanent 600 kW diesel-fueled emergency generator or the adequate size determined by the vendor and/or an electrical engineer during the bid process to appropriately support the critical facility. The project shall include installation of an automatic transfer switch (ATS), enclosure, a supply diesel tank, and electrical connections. The Fleet Management Facility is crucial for the city, as it provides fueling in preparation for, and during the recovery from, emergency events to multiple emergency response departments. Currently, the facility does not have a source of redundant power in the event of a power failure. The generator shall ensure continuity of fueling operations for critical services, including fueling police and fire vehicles during emergency future storm events. The generator, ATS, and electrical components shall be protected against a 500-year (0.2% annual chance) flood event by implementing specific activities or by locating the generator, ATS, and electrical components outside the Special Flood Hazard Area (SFHA), comply with applicable National Flood Insurance Program (NFIP) requirements and shall be protected against wind with a rated enclosure and appropriate anchoring based on its location requirements per ASCE 7 standards. The selected site shall provide sufficient space to maintain and fuel the generator and shall comply with the National Electrical Code working clearance requirements. Activities shall be completed in strict compliance with Federal, State and Local applicable Rules and Regulations.