Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Veterans Affairs was posted on January 27, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

5340--Anti-Ligature Door Monitoring System Amended Due Date: Thursday, February 4, 2021, by 4:30PM EST.

Closed
36C25021Q0309Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

335999 - All Other Miscellaneous Electrical Equipment and Component Manufacturing

Place of Performance

Department of Veterans Affairs VA Ann Arbor Healthcare System Maintenance & Repair (138MR) 2215 Fuller Rd. Building 1, Ann Arbor, OH, 48105-2303, USA

Set-Aside

NONE

Documents

3

36C25021Q0309+0001_1.docx

DOCX

36C25021Q0309+0002.docx

DOCX

36C25021Q0309.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

2 updates
PhaseClosed
Posted

Combined Synopsis

Notice updated

Response deadline changed from Jan 21, 2021 to Jan 28, 2021. The notice title changed. The notice description changed.

Notice updated

Response deadline changed from Jan 28, 2021 to Feb 4, 2021. The notice title changed. The notice description changed. The point of contact changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)
Contacts1 person available
OfficeDAYTON, OH, 45428, USA
Office AddressDAYTON, OH, 45428, USA
Contacts
John McCallumContracting Specialist

Full Description

Show more
***Amended Due Date: Thursday, February 4, 2021, by 4:30 p.m. EST.*** This is a combined synopsis/solicitation for commercial items prepared in accordance with FAR 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. This solicitation 36C25021Q0309 is issued as a request for quote (RFQ). This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2021-02 (eff. 11/23/20). The North American Industry Classification System (NAICS) number is 335999 and the business size standard is 500 employees. ANTI-LIGATURE DOOR ALARM SYSTEM ACUTE INPATIENT MENTAL HEALTH (AIMH) UNIT VA ANN ARBOR HEALTHCARE SYSTEM (VAAAHS) SCOPE OF WORK: The Contractor shall provide turnkey services to include all materials, tools, labor, and supervision necessary to install a Ligature Resistant Door Alarm System in the Acute Inpatient Mental Health (AIMH) unit at the VA Ann Arbor Healthcare System (VAAAHS), 2515 Fuller Road, Ann Arbor, MI 48105. Note: The 110V AC connection is not required or to be included in your quote. The contractor shall supply and install fifteen (15) door alarms on the corridor doors to each patient room within the AIMH unit. These alarms shall be Photoelectric optical type alarm assemblies. Contractor will be responsible for a completely functioning and commissioned system. The project location is an active mental health unit and must be treated as such. Contractor will need to assume that only one door will be able to be retro-fitted at a time. Census is typically high in this unit and contractor will need to complete each individual installation before moving on to the next door. The fifteen (15) door systems will each consist of, but shall not be limited to: Materials: Per door to include: 15 each electrified center pivot hinge Per room to include: 15 each top beam only entry door kits VA will provide and install required cylinder and core for each door Per system to include: 1 each master j-box, local display/interface panel and hallway siren 2 each multi-door hubs 1 each remote touch screen interface panel SALIENT CHARACTERISTICS OF LIGATURE RESISTANT DOOR ALARM SYSTEM: Provide ligature resistant, monitoring and notification system capable of detecting a ligature-initiated event at a patient bedroom door. An alarm system will trigger audio and visual notification devices at the bedroom door and nurse s station to alert staff of a ligature emergency. The system shall be addressable, self-monitoring, and able to diagnose alarm and system problems. The system shall be capable of documenting ligature-initiated events Components of Alarm System: 1. Ligature-initiating Alarm: a. Photoelectric sensor alarm assembly: Photoelectric sensors shall be positioned on the door and frame within anti-ligature casings constructed of Acetal (Polyoxymethylene-POM) an impact resistant plastic commonly called Delrin. Provide the following installation configuration for the sensors: Two sets of sensors at the top of the door at door and frame. b. The alarm assembly circuit shall be concealed and redundant providing a tamper resistant, failsafe operation. c. The alarm assemblies are to be installed with tamper resistant fasteners only. 2. Hinge and Power Transfer a. Power transfer section of hinge shall be housed at the top end of the continuous hinge to eliminate the potential of exposed wires or flex conduit. b. The power transfer section of the hinge shall be field removable to eliminate the need to remove the door when addressing electrical service issues. 3. Local Visual Alarm (Strobe) a. Install in corridor above monitored room doors throughout facility. b. Alarm unit shall be anti-ligature with a sloped top, made of resilient material and fastened with tamper resistant hardware. c. Door alarm units shall flash when any monitored door alarm is triggered at a ligature point initiated event. d. The door alarm strobe shall be turned off when a user s code is entered at the keypad at the room door. 4. Local Key switch: a. Wall mounted, shall be flush mounted or designed to be anti-ligature compliant. b. Coordinate specific location with VA AIMH Unit Manager and or Facilities Management Service Chief during installation. c. Designed for momentary actuation with spring return. 5. Keypad: a. Provide an LCD display notification for activation of all monitored patient bedroom doors. b. Flush mounted or designed to be anti-ligature. 6. Remote Monitoring Panel and Audible Alarm: a. The remote monitoring panel shall allow monitoring of each patient bedroom door from the nurse s station with a visual indicator of the location of the ligature-initiated event. b. The remote audible alarm will be a distinct tone not to be confused with other alarms located in the vicinity. 7. Control Panel: a. Panel and all elements of the alarm system shall be equipped with a dedicated battery backup system and emergency power feed for maintaining power to the control panel in the event of a power failure due to a power outage. b. Provide software for printing documented alarm events. DELIVERY: All materials/services procured under this contract shall be delivered and installed not greater than 90 days after the date of award. WARRANTY: All delivered and installed materials shall be in new condition and free of defects. All defects in materials or installation will be resolved by the contractor through a one (1) year product warranty period. Any manufacturer s warranty shall be extended to the VAAAHS as a pass through warranty. The proposed contract listed here is competed unrestricted. FOB destination. Deliver and turnkey installation to VA Ann Arbor Healthcare System, 2215 Fuller Road, Ann Arbor, MI 48105. Offerors must comply with all instructions contained in provision 52.212-1, Instructions to Offerors-Commercial, applies to this acquisition. 52.204-7, 52.204-16 52.212-2, Evaluation - Commercial Items: FAR provision 52.212-2 does not apply to this solicitation. Award will be based on lowest price technically acceptable offer. 52.212-3, Offeror Representations and Certifications-Commercial Items, a completed copy of this provision shall be submitted with the offer unless SAM registered which must be noted in the quotation. 52.212-4, Contract Terms and Conditions-Commercial Items. The following additional clauses apply: 52.204-13, 52.232-40, 852.211-72, 852.212-70, 852.203-70, 852.211-70, 852.232-72, 852.246-71, 852.212-71. 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items, to include clauses: 52.204-10, 52.209-6, 52.219-28, 52.222-3, 52.222-19, 52.222-21; 52.222-26, 52.222-36, 52.222-50, 52.223-18, 52.225-3, 52.225-13, 52.232-33 RESPONSES ARE DUE: Thursday, February 4, 2021, by 4:30 p.m. EST. E-mail responses to: John McCallum contact@example.gov

More opportunities from Department Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)

Same awarding agency

NAICS: 541380
New
Federal
Effluent Wastewater Testing - Saginaw VAMC
Solicitation # 36C25027Q0032
The Department of Veterans Affairs Network Contracting Office 10 is soliciting a firm fixed price contract for wastewater effluent laboratory analysis services at the Aleda E. Lutz VA Medical Center in Saginaw, Michigan. This procurement is a 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 541380. The scope of work requires the contractor to provide all labor, equipment, and supervision for the preparation, collection, storage, and transportation of wastewater effluent samples, as well as the performance of analytical testing and the provision of consultative services. All analysis must comply with 40 CFR Part 136, with specific requirements for PCB testing per the City of Saginaw Total PCB Minimization Program and mercury testing per Method 245.1. Formal analytical reports must be delivered to the facility GEMS Coordinator within seven business days of sampling. To be eligible for award, offerors must demonstrate at least three years of experience in wastewater effluent laboratory testing and one year of experience in sample collection, storage, and transportation. Additionally, a signed certification regarding limitations on subcontracting is mandatory for evaluation. The contractor is required to maintain a Quality Assurance Program and adhere to OSHA safety standards, as well as the City of Saginaw Code of Ordinances and Northwest Utilities Authority regulations. Performance is scheduled to begin on December 1, 2026, with invoicing submitted semi-annually or upon completion of service. The government will monitor performance based on turnaround times, customer service responsiveness, and the accuracy of quality control results.
Testing Laboratories and Services

POSTED

about 14 hours ago

DEADLINE

in 8 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS