The Mission Installation Contracting Command at Fort Lee plans to award a sole-source, firm-fixed-price contract to Siemens Industry, Inc. for the BAQnet Interface Control project. This contract entails removing the existing BACnet interface controls from a packaged Carrier heat pump at Bull Dental and installing Siemens Direct Digital Controls (DDC) on the unit. The new control system will include an expanded I/O TEC mounted above the ceiling, connected to various temperature sensors and outputs for compressor and electric heat stages. It will manage outside air dampers and power exhaust fans in economizer mode, employing a control strategy to maintain space temperature and reduce humidity by coordinating first-stage cooling and electric heat. A new graphic interface will also be developed for the heat pump on the Insight platform. The project falls under the NAICS code 334512, which covers building services monitoring controls and automatic manufacturing. This contract is a non-competitive acquisition justified by 10 U.S.C. 2304(c)(1), as the necessary equipment and services are available from only Siemens Industry, Inc., which meets the agency’s requirements. Interested parties must submit written evidence of their capability to provide the services within five business days, but competition is unlikely as the government retains full discretion to proceed with a sole-source award. All communications regarding this procurement should be directed to the contracting specialist, Mr. Waun A. Priest, at Fort Lee, VA.

General Info

Sole-source contract awarded to Siemens for installing and upgrading BACnet controls at Bull Dental.

NAICS

334512 - Automatic Environmental Control Manufacturing for Residential, Commercial, and Appliance Use

Place of Performance

VA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

special-notice

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W6QM Micc Ft Lee
ContactsNo contacts available
OfficeFORT LEE, VA, 23801, USA
Office AddressFORT LEE, VA, 23801, USA
ContactsNo contact information available

Full Description

Show more
Solicitation Number: 0010257966-0001 Notice Type: Special Notice Synopsis: NOTICE OF INTENT TO AWARD -- The Mission Installation Contracting Command - Fort Lee intends to negotiate and award a sole-source Firm-Fixed Price contract for BAQnet Interface Control in accordance with the format in FAR Subpart 15.2. The contract will be awarded to Siemens Industry, Inc Building Automation, 5106 Glen Alden Dr, Richmond, VA 23231. This requirement will be to remove the BACnet interface controls from the packaged Carrier heat pump at Bull Dental and install Siemens DDC on unit. Controls will consist of an expanded I/O TEC which will be mounted above the ceiling in the occupied space. Connected to the TEC will be a room temperature sensor, discharge air temperature sensor and outputs for controlling stages of compressors and electric heat. TEC will also control the outside air dampers and power exhaust fan when in economizer mode. Control strategy will be implemented to maintain space temperature and to also de-humidify the space by bringing on 1st stage cooling and electric heat when required. A new graphic will be created for this heat pump on Insight. The NAICS Code is 334512 Building services monitoring controls, automatic, manufacturing This is not a request for competitive proposals and no solicitation is available. All interested sources must respond in writing with clear and convincing evidence to support their ability to provide timely and effective services within five (5) business days of this publication. A determination by the government not to compete this action based on responses received is solely within the discretion of the government. Authority: 10 U.S.C. 2304(c) (1), Justification: Supplies (or services) required are available from only one or a limited number of responsible source(s) and no other type of supplies or services will satisfy agency requirements. Any questions regarding this acquisition should be directed to Mr. Waun A. Priest at +1 (555) 000-0000, contact@example.gov, Contract Specialist. Contracting Office Address: MICC Center - Fort Lee Building 7124, Fort Lee, VA 23801 Point of Contact(s): Waun Priest, +1 (555) 000-0000

Similar Contracts

Same NAICS industry code

NAICS: 334512
New
DIBBS
SWITCH, THERMOSTATIC
Solicitation # SPE7M8-27-T-0480
Solicitation SPE7M8-27-T-0480 is a request for quotations issued by the DLA Weapons Support Electrical Devices Division for the procurement of six thermostatic switches, identified by NSN 5930016019386 and Texas Instruments part number 11041-32-268. This is a restricted source item requiring engineering source approval by the government design control activity and is designated as a critical application item. The delivery is set for 235 days after the order is placed, with a need ship date of July 3, 2027, and a final required delivery date of October 31, 2027. Shipping is FOB Origin, with the destination for inspection and acceptance being the DLA Distribution DDSP New Cumberland Facility in Pennsylvania. The contract mandates strict adherence to the DLA Master List of Technical and Quality Requirements, including specific protocols for packaging, configuration change management, and the removal of government identification from non-accepted supplies. Packaging must comply with MIL-STD-129 and RP001, with hazardous materials requiring adherence to FED-STD-313 and TQ requirement IP025. Additionally, the contract prohibits the intentional addition of mercury or mercury-containing compounds except where functionally required. Administrative requirements include the use of the Wide Area WorkFlow system for invoicing and compliance with the Buy American and Balance of Payments Program, as well as various FAR and DFARS clauses regarding cybersecurity, safeguarding covered defense information, and the prohibition of covered defense telecommunications equipment.
DLA WEAPONS SUPPORT ELECTRICAL DEVICES DIV

POSTED

1 day ago

DEADLINE

in 11 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS