Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Defense was posted on May 5, 2014. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

63--Walk Through Metal Detector

Closed
W9124Q-14-R-METAFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334519
New
DIBBS
PROBE, HUMIDITY-TEMPERA
Solicitation # SPE4A5-27-T-2034
Solicitation SPE4A5-27-T-2034 is a request for quotations from the DLA Weapons Support ASC Supplier Oper OEM Division for the procurement of 12 humidity-temperature probes, identified by NSN 6685008037705. This critical application item must adhere to basic specification MIL-DTL-27723F and utilize connector class H per MIL-DTL-5051H with pin arrangements following MIL-STD-1651A Appendix A. The contract requires a first article test consisting of three probes, with the resulting test report conforming to MIL-HDBK 831. A specific focus is placed on monitoring sensor resistance during testing to ensure conformance with section 3.4.2.1, as failure to maintain these values will result in sensor failure. The procurement is not a small business set-aside and requires compliance with the Buy American Act and the Berry Amendment. Delivery is set as FOB Origin, with inspection and acceptance also occurring at the origin. Packaging and marking must comply with MIL-STD-2073-1E and MIL-STD-129. Due to the nature of the materials, suppliers must provide Safety Data Sheets and Hazard Warning Labels for approval by technical personnel prior to award in accordance with 29 CFR 1910.1200. Administrative requirements include the use of the Wide Area WorkFlow system for invoicing and adherence to NIST SP 800-171 and DFARS cybersecurity standards for safeguarding covered defense information.
DLA WEAPONS SUPPORT ASC SUPPLIER OPER OEM DIVISION

POSTED

about 16 hours ago

DEADLINE

in 7 days

AI Contract Overview

Show more

The White Sands Missile Range is conducting market research through a sources sought announcement to identify capable vendors for the installation, technical support, training, and repair of walk-through metal detectors. The required equipment must adhere to National Institute of Justice Standard 0601.02 and feature modular electronics, multi-dimensional coil sensors with 33 pinpoint zones, and the ability to detect guns and knives regardless of orientation. Key technical specifications include a weather-resistant aluminum construction, a battery backup providing 12 hours of power, and a detachable control unit capable of remote operation up to 300 feet. The system must also integrate with a Physical Access Control System and Database Management for real-time monitoring and diagnostics. Interested parties must submit a response by May 19, 2014, detailing their technical capabilities, financial resources, and past performance on similar contracts. Submissions are limited to twelve pages and must include basic business information, such as the Cage Code and business size. This announcement is for planning purposes only and does not constitute a solicitation, an intent to procure, or an obligation for the government to award a contract.

General Info

Market research for walk-through metal detector installation, support, and repair at White Sands.

NAICS

334519 - Other Measuring and Controlling Device Manufacturing

Place of Performance

MICC - White Sands Missile Range Directorate of Contracting, Bldg 143, 2nd Floor, Crozier Street White Sands Missile Range NM 8, NM

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W6QM Micc-White Sands
ContactsNo contacts available
OfficeWHITE SANDS MISSILE R, NM, 88002-5201, USA
Office AddressWHITE SANDS MISSILE R, NM, 88002-5201, USA
ContactsNo contact information available

Full Description

Show more
This is a sources sought announcement only and is not an intent to procure. A solicitation is not available at this time and any requests for a solicitation will not receive a response. The White Sands Missile Range, New Mexico Fast Burst Sited Defense Force is conducting market research to determine the capability in regards to the installation, technical support, training and repair services for a walk through metal detector. Metal Detector Minimum Requirements: Must meet the National Institute of Justice Standard 0601.02 Must be able to detect and locate guns, knives, and other flat and rod-shaped objects regardless of orientation All electronics shall be modular in design The detector shall use multiple coil circuits with dual alarm lights to indicate which side of the individual the detected item is located Must be capable of self-diagnostics and capable of self testing of all systems to identify failures The detection unit shall not require re-calibration each time the system is turned off and back on Must provide fully body coverage: coverage on the left, center, right, front, and back of the body from head to floor, providing uniform detection The unit must include individual zones that are adjustable for customization of detection characteristics and/or compensation for metallic environmental challenges Must have the capability to detect and discriminate signals from two (2) or more detectable items located in close proximity that may be detected as only one (1) Must include adjustable legs to provide for accurate leveling on uneven floors Major components include: 1. Walk-through portal/passage way 2. Control Unit 3. Test Unit TECHNICAL CHARACTERISTICS: Operating Temperatures: -4 F (-20 C) to 158 F (70 C)95% humidity non-condensing Power Supply Unit: Fully automatic input 100 to 240 VAC 50 or 60 Hz - five (5) watts; Uninterrupted Power supply (UPS); Battery Backup (12 hours) Construction Minimum: 3/32 in. (2.381mm) aluminum in strength and weather resistant Opening Sizes: Interior Height: 80 in.(2.032 meters) Interior Width: 30 in. (762mm) Programmable: Capable of 16 independent programs settings for zones and sensitivity Sensitivity Boost: Three (3) levels at ankle level Detection Sensors: Multi-dimensional coil 33 distinct pinpoint zones - customizable Sensitivity Levels: 200 Interference Protection: Faraday shielding Alarms: Audible and light-emitting diode (LED)Visual Testing Device: Simulate size, shape, and composition of threat objects meet FAA testing requirements Traffic Flow Indicators: LED Lights Infrared Sensor: Traffic control and counter Control Unit: Shall consist of the components to constantly monitor, input settings, and verify inputs of sensors. The Control Unit shall consist of the components to constantly monitor, input settings, and verify inputs of sensors. The control unit is to be attached to the exit side of the scanner and shall be able to be detached and operational from up to 300 feet from the detector. The control unit will consist of a multiple functional electronic digital keypad/touchpad. The keypad/touchpad requires human/machine interface (HMI) with numerical or function keys that can activate, deactivate, observe or change sensitivity and detector settings using secure codes. The Control Unit shall be programmed to be self-prompting for input. The LCD display shall be large, easily seen, backlit with alphanumeric display that reports in words to regulate, control and provide self-prompt functions of the control unit. CONTROL UNIT TECHNICAL CHARACTERISTICS: Display: LCD Connection to Unit: Wired with extension of 300 ft. for remote use Touchpad Controls: Operate, Off, Counter, Volume, +/-, Program and Access Tamper alarm: 10 seconds after access of touchpad Access Control: Dual-level access codes for Operators and Supervisors Displays: LED bar-graphs for Detection, Sensitivity, Alarm lights, Functionality, Program in Operation, Errors, Traffic count, Alarm activations and Alarm percentages CONTROL UNIT INTERFACE: The system shall include an interface module for network transmission of data and remote monitoring of system at the Physical Access Control System and Database Management. Integration with the Physical Access Control System and Database Management shall allow for control, real time monitoring and diagnostics capabilities. CONTROL UNIT INTERFACE TECHNICAL CHARACTERISTICS: Display : LCD (laptop or Desktop Monitor) Connection: 10-Base T Network System Capabilities: Monitor up to 4 scanners Capabilities: Change settings, LED bar-graph display, Functionality, Program in operation, Errors, Traffic Count, Alarm activations, Alarm Percentages, Technician trouble-shoot Access Control: Dual-level access codes, Operators, and Supervisory Each potential source shall provide a brief description of their ability to install, provide technical support, training and repair services for the walk through metal detector by providing the contract number(s), dollar value(s) and brief description of work previously or currently being performed, which specifically demonstrates the contractor's ability to successfully satisfy the requirements of the installation, providing technical support, training and repair services for the walk through metal detector. This description should include a demonstration that the source: has adequate financial resources to perform the contract, or the ability to obtain them; be able to comply with the required or proposed delivery or performance schedule, taking into consideration all existing commercial and governmental business commitments; has a satisfactory record of integrity and business ethics; has the necessary organization, experience, accounting and operational controls, and technical skills, or the ability to obtain them; and has the necessary production, construction, and technical equipment and facilities, or the ability to obtain them. All responses to this sources sought are limited to twelve pages and must include the following additional information: Business Name:__________________________ Business Size:___________________________ Point of Contact: _________________________ Phone Number: _________________________ Address: ______________________________ Cage Code: _____________________________ Interested sources shall submit all replies by email to contact@example.gov no later than 1700 MST on 19 May 2014. Acknowledgement of receipt will not be made. Any responses received after 19 May 2014 will not be considered. THE GOVERNMENT DOES NOT INTEND TO AWARD A CONTRACT ON THE BASIS OF THIS SOURCES SOUGHT OR TO OTHERWISE PAY FOR THE INFORMATION SOLICITED. This request for information is for planning purposes only and shall not be considered as an Invitation for Bid (IFB), Request for Quotation (RFQ), or Request for Proposal (RFP), or as an obligation on the part of the Government to acquire any products or services. Your responses to this sources sought will be treated as information only. No entitlement to payment of direct or indirect costs or charges by the Government will arise as a result of contractor submission of responses to this sources sought or Government use of such information. The Government reserves the right to reject, in whole or part, any contractor input resulting from this sources sought. The information resulting from this sources sought may be included in one or more RFP's, which may be released via the FEDBIZOPS portal.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS