Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Veterans Affairs was posted on March 16, 2018. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

65--583-18-2-997-0112 Equip nd04.14

Awarded
36C25018Q0508Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

This Request for Quote is issued by the Department of Veterans Affairs for the procurement of an OsteoCool RF Ablation System or an equivalent for the Richard L. Roudebush VA Medical Center in Indianapolis, Indiana. The required system must be an internally water-cooled, bipolar RF ablation system used for the palliative treatment of malignant metastatic lesions in vertebral bodies. The specific equipment requested includes one RF generator, one pump, two connector hubs, and one cart. Interested contractors must be registered in SAM and provide detailed business information, including their NAICS code 339113 and business size, to the contracting specialist by March 22, 2018. All supplied items must be TAA compliant and include a warranty. Delivery is required within 30 days after receipt of order, with shipping terms set as FOB Destination.

General Info

Contract Value

$81,800

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

OH, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Combined Synopsis

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)
ContactsNo contacts available
OfficeDAYTON, OH, 45428, USA
Office AddressDAYTON, OH, 45428, USA
ContactsNo contact information available

Full Description

Show more
This is a REQUEST FOR QUOTE (RFQ) for brand name items prepared in accordance with the format in FAR 13.5 as supplemented with additional information included in this notice for the Indianapolis VA healthcare facility, in Indianapolis, Indiana located at 1481 W. 10th Street Indianapolis, IN 46202. This is a request for quote, solicitation made in accordance with Federal Acquisition Circular (FAC) 2005-83. The North American Industry Classification System (NAICS) number is 339113. The NAICS size is 750 employees. Any contractor that believes they are capable and desires to claim preference for small business status must be registered with the SBA at http://web.sba.gov/pro-net/ and meet the requirements of FAR 19.102. Any contractor that believes they are capable and desires to claim preference for veteran owned small business status must be registered with the VIP at https://www.vip.vetbiz.gov as an SDVOSB or VOSB. Contractors that deem themselves capable of meeting the requirement shall provide the below information to Royce Jones, Contracting Specialist, at contact@example.gov no-later-than Thursday, March 22, 2018 at 4:30PM, EDT. Responses shall include: (1) Business Name and Address, (2) FSS Contract Number if applicable (3) Point of Contact Name, Phone Number and E-mail Address (4) DUNS and NAICS code (5) Business Size (6) Type of Business: service disabled veteran owned, veteran owned small business, 8a, HUBZone, woman-owned, etc. Contractor must be registered with https://www.sam.gov Supplies are to include only TAA compliant items. Items that are not TAA compliant must be clearly identified by the Contractor should the contractor choose to offer a quote if a RFQ is published. Contractor shall warranty supplies and work performed. FOB is Destination. Delivery 30 days ARO. Delivery is to: Department of Veterans Affairs Richard L. Roudebush VA Medical Center 1481 W. 10th Street Indianapolis IN 46202 Must include brand name or equal to the following. OsteoCool System Salient Characteristics The VA s requirement is for a RF ablation system that is internally water cooled and bipolar. The system must include one (1) RF generator, one (1) pump, two (2) connector hubs, and one (1) cart. The OsteoCool RF Ablation System is indicated for the palliative treatment of malignant metastatic lesions in a vertebral body. The OsteoCool Bone Access Kits are indicated for percutaneous access to bone6. The RF Ablation Probe uses a coaxial, bipolar technology that delivers RF energy to treat the pain generated by metastatic spinal tumors in a localized and controlled procedure. The OsteoCool provides a thermocouple placed on the distal tip of the device to monitor the temperature occurring in the area around the distal tip of the probe. A pump unit offers water cooled RF ablation. The system provides percutaneous access to bone and has the option to use two ablation probes simultaneously. The system supports simultaneous treatment of adjacent or multiple levels, simultaneous Bi-Pedicular ablation, and Uni-pedicular ablation. It also provides ablation therapy for reduction or eradication of 1 or more bone tumors (eg. metastasis) including adjacent soft tissue when involved by tumor extension, percutaneous, including imaging guidance when performed. ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 OsteoCool RF Generator LOCAL STOCK NUMBER: OCO1 1.00 EA Funding/Req. Number: 1 0002 OsteoCool RF Pump LOCAL STOCK NUMBER: OCO2 1.00 EA Funding/Req. Number: 1 0003 OsteoCool Connector Hub LOCAL STOCK NUMBER: OCO4 2.00 EA Funding/Req. Number: 1 0004 Cart LOCAL STOCK NUMBER: OCA01 1.00 EA Funding/Req. Number: 1 GRAND TOTAL

More opportunities from Department Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)

Same awarding agency

NAICS: 562910
New
Federal
Trauma Cleaning IDIQ
Solicitation # 36C25027Q0070
The Department of Veterans Affairs Network Contracting Office 10 is soliciting an Indefinite Delivery Indefinite Quantity (IDIQ) contract for specialized trauma and crime scene cleaning services at the Louise Stokes VAMC and various CBOC locations in Ohio. This one-year firm-fixed-price contract is designed for as-needed services to decontaminate hospital patient rooms and exam rooms following incidents such as large or small hazardous drug spills, blood or bodily fluid contamination, and traumatic events including suicides, murders, or gunshot wounds. The ordering period is scheduled from November 30, 2026, through November 29, 2027, with a government option to extend performance by up to six months. The contractor must possess specific expertise in trauma cleanup, maintain a written bloodborne pathogen exposure control plan, and utilize EPA-registered disinfectants approved by the Infection Prevention and Chemical Hygiene Committees. Compliance with OSHA 29 CFR 1910.1030, CDC guidelines for disinfection and sterilization, and NIOSH standards for fentanyl exposure is mandatory. Additionally, the contractor must ensure the total destruction of any Private Health Information (PHI) and adhere to strict VA security and encryption standards. Award will be based on a comparative evaluation of technical capability, past performance from the last four years, and total contract value, with the government reserving the right to award to a higher-priced offer if justified by superior technical merit or performance.
Remediation Services

POSTED

2 days ago

DEADLINE

in 15 days
View Details
NAICS: 541380
New
Federal
J065--RO Equipment Maintenance RFQ Amendment to Answer Industry Questions
Solicitation # 36C25027Q0051
The Department of Veterans Affairs, Network Contracting Office 10, is soliciting quotes for a firm-fixed-price contract to provide preventive maintenance services for reverse osmosis systems at the Ann Arbor VA Medical Center in Michigan. The anticipated period of performance runs from January 8, 2027, to January 7, 2032, consisting of a one-year base period and four optional one-year extensions. The scope of work includes quarterly maintenance of SPS and lab RO systems, as well as the provision of specific consumables such as mixed-bed tanks and vent filters. Specifically, the government requires up to four mixed-bed tanks per quarter and four vent filters annually. The procurement is conducted as a full and open, unrestricted competition, allowing for the use of qualified subcontractors for onsite maintenance and emergency repairs. However, the prime contractor must provide a direct employee to supervise technicians. Evaluation is based on technical capability and past performance, with a neutral rating assigned to offerors lacking relevant history. Technical proposals are limited to ten pages and must demonstrate a clear understanding of the project's organization and staffing. All contractor personnel are required to complete VA privacy and security training before arriving at the facility. Quotes are due by November 16, 2026.
Testing Laboratories and Services

POSTED

2 days ago

DEADLINE

in 15 days
View Details
NAICS: 541350
New
Federal
H212--Annual Test/Inspection of FireFly Device and Door Drop Cleveland VA Medical Center
Solicitation # 36C25027Q0034
Solicitation 36C25027Q0034 is a request for quotation from the Department of Veterans Affairs for the annual inspection and testing of 19 Cookson Firefly release devices and drop doors at the Louis Stokes Cleveland VA Medical Center and associated Fisher House locations in Cleveland, Ohio. The scope of work includes comprehensive visual inspections of door assemblies, tracks, and locking mechanisms, as well as drop testing to ensure compliance with NFPA 80 and Joint Commission standards. The contract is structured with a base year running from December 1, 2026, to December 1, 2027, and four subsequent option years extending through December 1, 2031. All annual preventive maintenance must be completed by January 31 each year. This procurement is 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 541350. Award decisions will be based on the most advantageous offer, with technical capabilities and past performance weighted more heavily than price. Specifically, technicians must hold IDEA Certified Rolling Steel Fire Door Technician certification. Offerors must submit a firm-fixed-price quotation, a detailed Quality Control Plan within 14 days of award, and a signed VA Notice of Limitations on Subcontracting certificate to be eligible for evaluation. The response deadline for this solicitation is November 4, 2026.
Building Inspection Services

POSTED

2 days ago

DEADLINE

in 3 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS