6515--CADD Solis Ambulatory Infusion Pump Monthly Rental Agreement

Closed
36C26222Q0851Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

Raymond G. Murphy VA Medical Center 1501 San Pedro Dr SE, Albuquerque, NM, 87108, USA

Set-Aside

NONE

Documents

1

36C26222Q0851.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)
Contacts1 person available
OfficeGilbert, AZ, 85297, USA
Office AddressGilbert, AZ, 85297, USA
Contacts
April GravesApril Graves

Full Description

Show more
THIS REQUEST FOR INFORMATION (RFI) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES-SOUGHT DESCRIPTION This is NOT a solicitation announcement. This is a sources-sought/RFI only. The purpose of this sources-sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 339131 (size standard of 750 Employees). Responses to this sources-sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources-sought, a solicitation announcement may be published. Responses to this sources-sought synopsis are not considered adequate responses for a solicitation announcement. The Department of Veterans Affairs (VA), VISN 22 Network Contracting Office, is seeking CADD Solis Ambulatory Infusion Pump Monthly Rental Agreement that meets the following salient characteristics for the New Mexico VA Healthcare System: SALIENT CHARACTERISTIC FOR THE PATIENT CONTROLLED EPIDURAL ANALGESIC (PCEA) PUMP FOR ALBUQUERQUE VA MEDICAL CENTER Station is looking for Brand name or equal RENTAL AGREEMENT for a CADD-Solis Ambulatory Infusion Pump, v4. The rental agreement should include all necessary costs of operation for pre-programmed pumps to include the drug library, and repairs/maintenance. After reviewing our current inventory of PCEA pumps, our mission, and our goal to provide the Gold Standard in patient care the following salient characteristics have been deemed as must have for facility. 1. Patient Care Requirements must include: Ambulatory Infusion Pump that is indicated for all the following: intravenous, intra-arterial, subcutaneous, intraperitoneal, in close proximity to nerves, into an intraoperative site (soft tissue, body cavity/surgical wound site), epidural space, or subarachnoid space infusion. Must be compatible with our current fleet of CADD Solis pumps with PCA dosing key along with handheld dose cord. Must have software version 4.2 or greater with the future proof ability to be upgraded to version 5.x. Must have a home screen display no bigger than 2.12 in. x 2.12 in. showing therapy, drug, medication delivery settings and reservoir, battery, and pump status while running. Must have color indicators for therapy protocol, pump operating status and alarms/alerts. Color indicators to define the therapy. Must have an On-screen PCA dose graph, delivery history and pie chart with the ability to get real time data for each pump. The pump must accommodate an IV bag, syringes and CADD Medication Cassette Reservoirs in all sizes. Example 50mL, 100mL, 250mL. The pump must have customizable alarm volume low, medium, and high settings with distinctive alarm sound themes. 2. Patient Safety Requirements must include: The pump must have a customizable on-board therapy-based library with up to 500 protocols. Must have the ability to have user defined soft and hard limits. The provider must have the ability to define all soft and hard limits, and initial values. Must have the ability to designate authorized users with defined levels of security access. Must have minimum 3 levels of customizable security access: keypad code, clinician code, and administrator code. Must have soft key interfacing for programming to mimic cell phone technology. Must have a scroll keypad to assist in eliminating double bounce errors and decimal errors. 3. Medication Safety Software Requirements: Must have a medication safety software application to have the ability to enter and store pain management protocols into a computer database which can be deployed to the infusion pump. The pump must have the ability to customize protocols, drug names, concentrations, and dosing limits to reflect the treatment. Must have the ability to print bar codes for pain management medication right from the program s list of approved drugs. Must be able to print an Rx form for each protocol. Must have Adult/child size indicator display style to help distinguish sound-alike, look-alike drugs from one another. The pump must have a status bar which displays reservoir volume status, delivery status & power status at all times. Each indicator should be color-coded for an immediate visual indication of pump operating status. The pump must have alarm/alert screens which are color coded to low priority, medium priority, high priority & system fault conditions. Must be able to operate with regular batteries, rechargeable battery pack & AC power. Must have an air-in-line detector that will alarm if air is detected in the tube. Must have Preventative Maintenance reminder to alarm when the pump should be maintenance. The pump must be splash proof & moisture protected. The pump must be small compact size for mobility. Size should be within 1 +/- of the following parameters 1.6 in. X 4 in. X 5 in. excluding cassette and weigh no more than 21 oz. The pump must have a cassette/ keypad lock for added safety. The pump must have event logs that are date and time stamped with the ability to store up to 5000 events.

More opportunities from Department Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)

Same awarding agency

NAICS: 325120
New
Federal
AN11--501 - Dry Ice - Base 4
Solicitation # 36C26227Q0076
The Department of Veterans Affairs, through Network Contracting Office 22, has issued this Request for Information and Sources Sought Notice to identify qualified sources for the weekly delivery of 5/8-inch dry ice pellets. The requirement supports the Cooperative Studies Program Clinical Research Pharmacy Coordinating Center's Biorepository in Albuquerque, New Mexico. The anticipated scope involves the delivery of 600 pounds of dry ice pellets every Monday, totaling 31,200 pounds annually. The intended period of performance consists of one base year with four optional extension years. The government requires the vendor to provide specialized storage containers that are insulated with walls at least 2.5 inches thick, feature a hinged lid with a closing mechanism, and are equipped with at least four casters to support a minimum weight of 700 pounds. A critical performance standard is that the containers must limit sublimation loss to less than 8 percent of the total mass every 24 hours. This notice is issued for planning and market research purposes only and does not constitute a formal solicitation. Interested respondents must provide their business size status relative to NAICS 32510, SAM.gov entity details, and information regarding their capabilities, lead times, and compliance with the Buy American Act and the Non-Manufacturer Rule. Responses are due by November 4, 2026.
Industrial Gas Manufacturing

POSTED

about 11 hours ago

DEADLINE

in 6 days
View Details
NAICS: 811310
New
Federal
J041--PMI ICE Machine Service Contract -w/wd, B+4, POP 1/1/2027 - 12/31/2027
Solicitation # 36C26227Q0030
Solicitation 36C26227Q0030 is a total Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside for comprehensive preventive maintenance, sanitation, and performance verification services for a fleet of 62 Follett ice machines and water dispensers. The services will support the Phoenix VA Healthcare System, covering the main campus and nine Community-Based Outpatient Clinics, including a location in Show Low, Arizona. The period of performance is scheduled from January 1, 2027, to December 31, 2027, with options to extend services. Maintenance frequencies are set at four preventive maintenance visits per year for the main campus and two per year for the clinics, encompassing refrigeration checks, descaling, electrical inspections, and deep cleaning in accordance with OEM specifications and healthcare facility standards. Award will be determined based on the most advantageous offer using a best-value comparative evaluation method rather than lowest price technically acceptable. Evaluation factors include the technical approach to meeting the statement of work, the offeror's specific experience in commercial refrigeration support over the past three years, price reasonableness, and past performance via CPARS. The successful contractor must provide all approved cleaning materials and safety data sheets, maintain specific insurance coverages for general, automobile, and employer liability, and adhere to strict personnel vetting and credentialing requirements. Invoices must be itemized by service date and contract obligation number to ensure payment processing.
Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

POSTED

about 11 hours ago

DEADLINE

in 12 days
View Details
NAICS: 562211
New
Federal
F999--Hazardous Material & Waste Disposal
Solicitation # 36C26227Q0071
The Department of Veterans Affairs, through Network Contracting Office 22, has issued a sources sought announcement under solicitation number 36C26227Q0071 to identify qualified contractors for hazardous material and waste management services. This is a market research effort and not a formal solicitation for award. The scope of work involves providing all labor, materials, equipment, and transportation for hazardous waste disposal, collection, and emergency response services. Performance will take place at the Greater Los Angeles VA Healthcare System West LA Main Campus and various Community Based Outpatient Clinics, including locations in San Gabriel Valley, Santa Barbara, Santa Maria, San Luis Obispo, Bakersfield, and the Captain Rosemary Bryant Mariner clinic. The acquisition is classified under NAICS code 562211 for Hazardous Waste Treatment and Disposal, with a size standard of 47.0 million dollars. In accordance with Public Law 109-461, the government is considering a total set-aside for Service-Disabled Veteran Owned Small Businesses, though it may opt for alternate set-asides or full and open competition based on the responses received. Interested firms must be registered in the System for Award Management and, if applicable, the SBA VetCert system. To be considered, respondents must submit a capability statement detailing their qualifications and past performance from the last five years, along with a completed price schedule for market research purposes. All submissions must be emailed to the contract specialist by November 6, 2026.
Hazardous Waste Treatment and Disposal

POSTED

1 day ago

DEADLINE

in 8 days
View Details
NAICS: 811111
New
Federal
Yuma Mobile Vet Center (MVC) Repair
Solicitation # 36C26227Q0055
The Department of Veterans Affairs, through the Southern Arizona Health Care System, is soliciting quotes for a firm-fixed-price service contract to perform non-mechanical body repairs on Mobile Vet Center 0828. The scope of work involves repairing cosmetic and potential structural damage to the driver's rear side, including the removal and replacement of damaged body panels, decals, and the body wrap. The selected contractor will be responsible for repainting repaired surfaces to match the existing finish and providing a craftsmanship warranty on all work. Performance will take place in Tucson, Arizona, with a base period of performance from December 1, 2026, to November 30, 2027. This opportunity is a total Small Business Set Aside, and the government will evaluate offerors based on their service-disabled Veteran-owned or Veteran-owned small business certification status and their intent to use such entities as subcontractors. Proposals must be submitted by November 9, 2026, at 11:00 am. A site visit is scheduled for November 3, 2026, in Tucson. To be eligible for award, offerors must provide a signed certification regarding limitations on subcontracting and represent compliance with FASCSA and telecommunications prohibitions. Payments will be processed via Electronic Funds Transfer through the System for Award Management.
General Automotive Repair

POSTED

1 day ago

DEADLINE

in 11 days
View Details
NAICS: 335910
New
Federal
6135--UPS Battery Replacement
Solicitation # 36C26227Q0064
Solicitation 36C26227Q0064 is a firm-fixed-price request for quotes issued by the Department of Veterans Affairs, NCO 22, for the one-time replacement of 60 batteries for the Main Server Uninterrupted Power Supply (UPS) at the San Diego VA Medical Center. This procurement is a total small business set-aside under NAICS code 335910, with a small business size standard of 1,250 employees. The scope of work requires a certified technician to remove and replace 60 C&D UPS12-545PLP batteries across two cabinets in Building 1, Room BB100-1. The contractor is responsible for all freight, installation, testing, removal, and recycling costs, and must ensure the work is completed during one coordinated event within 365 days after receipt of order. The award will be based on price only. Offerors must submit a completed and signed SF 1449 via email to the contracting officer by 15:00 Pacific Local Time on November 10, 2026. Required submission elements include the vendor's SAM UEI number, acknowledgement of amendments, specific manufacturer and model numbers, and a certificate of compliance regarding limitations on subcontracting. Performance requires strict adherence to safety protocols, including Lock out/Tag out procedures on the primary feed and tightening terminals to manufacturer torque specifications. The contractor must maintain all necessary licenses and insurance, and comply with Buy American and other federal regulatory clauses.
Battery Manufacturing

POSTED

1 day ago

DEADLINE

in 15 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS