This Sources Sought opportunity from Department Of Veterans Affairs was posted on January 14, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
6515--Gamma Detection System (GDS) Control Unit Brand name or Equal to Devicore Medical Products, Inc.
Closed
36C26026Q0251FederalSubmission Closed
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
General Info
Agency
Department Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)
NAICS
339112 - Surgical and Medical Instrument Manufacturing View NAICS
Place of Performance
Department of Veterans Affairs Portland VA Medical Center, Portland, OR, 97239, USASet-Aside
NONE
Timeline
PhaseClosed
Submission Closed
Organization & Contact Information
Show more
AgencyDepartment Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)
Contacts1 person available
OfficeVANCOUVER, WA, 98661, USA
Organization / Agency
Department Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)
Office AddressVANCOUVER, WA, 98661, USA
Contacts
Full Description
Show more
THIS IS A REQUEST FOR INFORMATION ONLY. The purpose of this notice is to obtain information regarding the availability and capability of all qualified sources to fulfil a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method.
The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources for: Gamma Detection System (GDS) Control Units. Brand name or equal to Neoprobe 2400 (GDS) Control Units, Including Software manufactured by Devicore Medical Products, Inc.
The Portland VAMC requires
Quantity
Description
Manufacturer Part Number
2
Neoprobe 2400 GDS Control Unit, Including Software
NPCU4
The Gamma Detection system (GDS) detects the presence of gamma rays emitted from radioactive isotopes in body organs or tissue. The system provides both a visual indicator (count bar) and audible indicator (an increasing or decreasing sound that varies in pitch) as the level of gamma radioactivity increases or decreases. Gamma Probe Salient Characteristics: The Neoprobe Gamma Detection system (GDS) console (Model# NPCU4) with Bluetooth wireless technology, detects the presence of gamma rays emitted from radioactive isotopes in body organs or tissue. The system provides both a visual indicator (count bar) and audible indicator (an increasing or decreasing sound that varies in pitch) as the level of gamma radioactivity increases or decreases. Portland VA currently has one Bluetooth cordless probe with collimator that is sterilizable (model# 1100-03307 with collimator tip model# 1013) and two unsterile corded probes with collimator (model# NPR14 with collimator model# NPE14 and cord model# MPA76). We are required to have two Gamma Detection system (GDS) consoles for when we have two surgeons operating at the same time due to two services using this system (General surgery and ENT). The GDS is used for intraoperative lymphatic mapping, parathyroidectomy and other clinical applications to target radiolabeled tissues. Detecting gamma radiation with a hand-held probe is based on the inverse law of physics, which allows detection of radiation emitted from a small source. Placing the probe close to a radioactive site increases the number of counts detected and localization occurs on the console. The console displays visual information and data on the LED screen in liquid crystal fonts. The console does not require sterilization. However, it must be capable of being disinfected with a hydrogen peroxide-based cleaning wipe such as Oxivir .
Potential candidates having the capabilities necessary to provide the above stated requirement are invited to respond to this Request for Information via e-mail to Gregory Watson at Gregory,Watson2@va.gov no later than 20 January 2026, 06:00 PST. No telephone inquiries will be accepted.
RESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION: company name, address, and business size; point of contact name, phone number, e-mail address. NAICS Code 339112 is applicable to determine business size standard. Any questions or concerns may also be directed to Gregory Watson via e-mail.
The Gamma Detection system (GDS) detects the presence of gamma rays emitted from radioactive isotopes in body organs or tissue. The system provides both a visual indicator (count bar) and audible indicator (an increasing or decreasing sound that varies in pitch) as the level of gamma radioactivity increases or decreases. Gamma Probe Salient Characteristics: The Neoprobe Gamma Detection system (GDS) console (Model# NPCU4) with Bluetooth wireless technology, detects the presence of gamma rays emitted from radioactive isotopes in body organs or tissue. The system provides both a visual indicator (count bar) and audible indicator (an increasing or decreasing sound that varies in pitch) as the level of gamma radioactivity increases or decreases. Portland VA currently has one Bluetooth cordless probe with collimator that is sterilizable (model# 1100-03307 with collimator tip model# 1013) and two unsterile corded probes with collimator (model# NPR14 with collimator model# NPE14 and cord model# MPA76). We are required to have two Gamma Detection system (GDS) consoles for when we have two surgeons operating at the same time due to two services using this system (General surgery and ENT). The GDS is used for intraoperative lymphatic mapping, parathyroidectomy and other clinical applications to target radiolabeled tissues. Detecting gamma radiation with a hand-held probe is based on the inverse law of physics, which allows detection of radiation emitted from a small source. Placing the probe close to a radioactive site increases the number of counts detected and localization occurs on the console. The console displays visual information and data on the LED screen in liquid crystal fonts. The console does not require sterilization. However, it must be capable of being disinfected with a hydrogen peroxide-based cleaning wipe such as Oxivir .
Potential candidates having the capabilities necessary to provide the above stated requirement are invited to respond to this Request for Information via e-mail to Gregory Watson at Gregory,Watson2@va.gov no later than 20 January 2026, 06:00 PST. No telephone inquiries will be accepted.
RESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION: company name, address, and business size; point of contact name, phone number, e-mail address. NAICS Code 339112 is applicable to determine business size standard. Any questions or concerns may also be directed to Gregory Watson via e-mail.