Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on June 21, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6515--IM 900 BQ Slit Lamps

Closed
36C25621Q1230Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 339113
New
DIBBS
VALVE, SAFETY RELIEF
Solicitation # SPE7M4-27-T-1454
Solicitation SPE7M4-27-T-1454 is a request for quotations issued by the DLA Weapons Support Fluid Handling Division for the procurement of 17 safety relief valves, identified by NSN 4820-01-385-0125. These components are designated as critical application items associated with Northrop Grumman Systems Corp and must adhere to top drawing DAA3222A703-003 and assembly drawing DAA3222A702-001. A key performance requirement is the verification of correct cracking pressure per standard GN4, which includes the specific installation of shear ring DAA3222D715-003 or DAA3222D705-003. The delivery schedule specifies a period of 699 days after order, with a required delivery date of July 12, 2029, shipped FOB Origin to DLA Distribution Depot Hill AFB, Utah. This procurement carries stringent security and compliance mandates. It requires Cybersecurity Maturity Model Certification (CMMC) Level 2 and adherence to DFARS 252.204-7012 for safeguarding covered defense information. Because the item is a restricted source item, it requires government design control activity engineering source approval and is subject to a Boeing Rights Guard License Agreement, necessitating strict data non-disclosure and destruction. Additionally, the technical data is subject to ITAR or EAR export controls, requiring contractors to have an approved US/Canada Joint Certification Program certification. Packaging must comply with ASTM D3951 and MIL-STD-129, while all payment requests must be processed electronically through the Wide Area WorkFlow system.
DLA WEAPONS SUPPORT FLUID HANDLING DIVISION

POSTED

about 12 hours ago

DEADLINE

in 4 days

General Info

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

Central Arkansas Veterans Healthcare System Bldg. 182 2200 Fort Roots Drive, North Little Rock, MS, 72114, USA

Set-Aside

NONE

Documents

1
DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 256-NETWORK Contract Office 16 (36C256)
Contacts1 person available
OfficeRIDGELAND, MS, 39157, USA
Office AddressRIDGELAND, MS, 39157, USA
Contacts
William ShaverContract Specialist

Full Description

Show more
DEPARTMENT OF VETERANS AFFAIRS VETERANS INTEGRATED SERVICE NETWORK (VISN) 16 G.V. SONNY MONTGOMERY VETERANS HEALTHCARE SYSTEM REQUEST FOR INFORMATION 36C25621Q1230 REQUESTED RESPONSES: The intent of this Request for Information is to establish sources in order to define the procurement strategy. Interested contractors are requested to respond in accordance with the following Please respond to this RFI if you are capable of providing the brand name products listed in the Statement of Work and Schedule found in the background section below. In the response please cite business size status. POTENTIAL SOURCES SHALL PROVIDE THE FOLLOWING INFORMATION IN THEIR RESPONSE: 1) Company name, address, phone number, primary contact(s), e-mail address, NAICS code(s), business size (i.e., small/large) and DUNS Number. 2) Provide a Statement of Capability that demonstrates the offeror's past performance in providing these types of supplies. Please include the following: (a) Proof of OEM or OEM distributor of brand name supplies. (b) examples of prior completed Government contracts, references, and other related information. CONTACT INFORMATION AND RESPONSE DUE DATE: Please email all responses to contact@example.gov. Please respond to this RFI no later than 07:00 Central Standard Time on Monday, June 28, 2021. DISCLAIMER: This RFI is issued solely for informational and planning purposes and does not constitute a solicitation. Responses to this notice are not offers and cannot be accepted by the Department of Veterans Affairs to form a binding contract. Respondents are solely responsible for all expenses associated with responding to this RFI. BACKGROUND: Statement of Work Scope Both IM 900 BQ Slit Lamps will be received at CAVHS warehouse, Bldg. 182, at 2200 Fort Roots Drive, North Little Rock, Arkansas. After inspection and internal identification by Biomed Department one will be installed in the North Little Rock VA Eye Clinic at 2200 Fort Roots Drive, North Little Rock, AR 72114 and the other to be installed in the Little Rock VA Eye Clinic at 4300 W. 7th Street, Little Rock, AR 72205. Plan for delivery of equipment on or before 9/1/21. These cameras would enable our staff to document any external suspicious lesions, including possible malignancies for comparison with future exams. This would give good detailed photos of lesions, nevus, adnexa and other external needs not possible with our current internal camera. These cameras would enable us to safely take care of our patients, by documenting these lesions for medical/legal needs. In cases of our ocular plastics, these cameras would enable us to get quality photos for documentation prior to surgery for reimbursement. This camera will attach to one of our current BQ slit lamps. This will aide our high-volume clinic care for these difficult cases without sending them out to community. Contractor shall provide all necessary tools, interfaces, equipment/hardware, software, licenses, delivery, installation, warranty, and training. System Requirements Use of Several Devices, Registration Link The EyeSuite software is designed for optimal patient flow in busy practices. Supporting the Haag-Streit imaging solutions, EyeSuite makes the slit lamp fully networkable. Thus, no proprietary third-party software is required to provide connectivity. If the slit lamp is connected to an EyeSuite server, all the images taken can be accessed remotely from any number of viewing stations connected to the same database. Furthermore, the optional Image Capture Module software enables the import of digital images or documents from other devices (fundus cameras, perimeters etc.) into the HEY patient file. All PII will be stored behind a (MDIA) Medical Device Infrastructure Architect on VLAN Virtual Lan. The C&A requirements do not apply, and a Security Accreditation Package is not required. The C&A requirements do not apply, and that a Security Accreditation Package is not required. Specifications Illumination Light-source LED for examination (slit and background illumination) Slit width 0 14mm continuous Slit length 1 14mm continuous and fixed apertures Illumination field diameter ø 8/5/3/2/1/0.2mm Slit image rotatability ± 90° Swiveling of the slit illumination to the microscope axis Horizontal ± 90°, vertical 0 20° Filters Blue, red-free (green), grey (10%) and optional yellow Microscope Ocular magnification 12.5× Stereo angle 13° (convergent optics) Range of adjusting eyepieces +7 to -7 diopters Pupil distance 52 78 mm Magnification changer 6.3×/10×/16×/25×/40× Object field ø in mm 32.0/20.0/12.7/8.0/5.1 Instrument base Operation Single handed 3-dimensional operation of the control lever Spatial adjustment of the instrument base 100mm (length), 100mm (side), 30mm (height) Measures (W x L x H) 312mmx305mmx676mm Net weight 12.7 kg (without power supply, head rest and options. The operation software includes functions to communicate with the user, to control image acquisition, to store images and data, to process and analyze the acquired images, and to document the examination results. Submittals: N/A Maintenance WARNING! Do not modify this equipment without authorization of the manufacturer. Installation and repairs may only be performed by trained specialists. Contact your Haag-Streit representative for installation, repairs and modification work on the system. The contact details are available at www.haag-streit.com. Only original Haag-Streit replacement parts may be used. 8.1 Device inspection To check the correct function, proceed as follows: Insert the test piece in the radial movement bearing, while aligning the surface at a right-angle to the Microscope Set the slit length to 8 or 14mm Illumination intensity to 50% Set the magnification of the Microscope to max. Set the ocular so that the structure on the test piece is shown in focus. In doing so, turn the ocular from the (+) to the (-) side. Switch on camera For all magnifications, the structure of the test piece in the ocular and in the cam- era image must be sharply imaged Turn on the illumination of the 0.2mm diaphragm Turn on the crosshairs in EyeSuite, the cross must be inside the illuminated dot Servicing To ensure a long service life, the device should be cleaned weekly as described and covered with a dust cover when not in use. We recommend having the device inspected by an authorized service technician annually. Cleaning and disinfection the Haag-Streit slit lamps and their accessories can, if required, be carefully wiped down with ready-for-use disposable 70% ethanol disinfectant wipes. Surface friendly disinfectants (containing aldehyde or aldehyde-free) are also permitted, such as Kohrsolin FF. Training Heidleburg rep will conduct training at time of installation. Delivery & Installation All items will be delivered per VA Policy. To ensure the overall safety of the system, only certified staff of your local Haag-Streit Engineering distributor must install the IM 900 BX WARNING: Only use the supplied USB 3.0 cable (REF 1022373) for the connection to the PC. Only use medically approved PCs or operate via a medically approved isolating transformer. Auxiliary units on the PC (e.g. printer, monitor) must be operated through an isolating transformer. Ethernet may only be used through a galvanic isolation in accordance with EN 60601-1. The power supply unit's mains connector must be accessible in order to allow for disconnection from the electric mains at any time! Installation to be coordinated by POC Johnny Hollis of VA Biomed Department with manufacturer (Haag-Streit) rep. Privacy Officer, Info Security Officer and Records Manager s statements: Information Systems Officer, Information Protection: The contractor will not have access to VA Desktop computers, nor will they have access to online resources belonging to the government while conducting services. If removal of equipment from the VA is required, any memory storage devices, such as hard drives, solid state drives and non-volatile memory units will remain in VA control and will not be removed from VA custody. Privacy Officer: The contractor will not have access to protected Patient Health Information (PHI) nor will they have the capability of accessing patient information during the services provided to the VA and if removal of equipment from the VA is required, any memory storage devices, such as hard drives, solid state drives and non-volatile memory units will remain in VA control and will not be removed from VA custody. All research data available for Contractor analyses is de-identified. Records Manager: Citations to pertinent laws, codes and regulations such as 44 U.S.C chapters 21, 29, 31 and 33; Freedom of Information Act (5 U.S.C. 552); Privacy Act (5 U.S.C. 552a); 36 CFR Part 1222 and Part 1228. Contractor shall treat all deliverables under the contract as the property of the U.S. Government for which the Government Agency shall have unlimited rights to use, dispose of, or disclose such data contained therein as it determines to be in the public interest. Contractor shall not create or maintain any records that are not specifically tied to or authorized by the contract using Government IT equipment and/or Government records. Contractor shall not retain, use, sell, or disseminate copies of any deliverable that contains information covered by the Privacy Act of 1974 or that which is generally protected by the Freedom of Information Act. Contractor shall not create or maintain any records containing any Government Agency records that are not specifically tied to or authorized by the contract. The Government Agency owns the rights to all data/records produced as part of this contract. The Government Agency owns the rights to all electronic information (electronic data, electronic information systems, electronic databases, etc.) and all supporting documentation created as part of this contract. Contractor must deliver sufficient technical documentation with all data deliverables to permit the agency to use the data. A.1 PRICE/COST SCHEDULE ITEM INFORMATION ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 2.00 EA __________________ __________________ IM 900 Imaging System For BQ LOCAL STOCK NUMBER: HS7220550 GRAND TOTAL __________________ DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. End of Document

More opportunities from Department Of Veterans Affairs → 256-NETWORK Contract Office 16 (36C256)

Same awarding agency

NAICS: 561621
New
Federal
J012-- Fire Alarm Suppression Maintenance & Repair Services
Solicitation # 36C25627Q0041
Solicitation 36C25627Q0041 is a Request for Quotation issued by the Department of Veterans Affairs for fire alarm and fire suppression monitoring, detection, testing, maintenance, and repair services at the Southeast Louisiana Veterans Health Care System medical campus in New Orleans, Louisiana. This procurement is 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 561621. The scope of work covers 17 buildings and a concourse, requiring the contractor to provide annual, semi-annual, and quarterly preventative maintenance, monthly monitoring, and unlimited 24/7 emergency services with a mandatory two-hour onsite response time for system trouble. All work must comply with NFPA and NEC 70 standards, and technicians must hold NICET Level III certification and OEM authorization for Notifier NFS2-640 systems. The contract features a base period of performance from December 1, 2026, through November 30, 2027. Award will be determined using the Lowest Price Technically Acceptable (LPTA) methodology, evaluating offerors on price, technical capabilities, and a requirement for at least five years of relevant experience. Proposals must be submitted in three volumes covering price, experience, and technical capabilities by November 4, 2026, at 10:00 a.m. CDT. The pricing structure includes a monthly rate for maintenance, an hourly rate for call-back services, and a 50,000 dollar annual parts rider for emergency repairs.
Security Systems Services (except Locksmiths)

POSTED

about 17 hours ago

DEADLINE

in 12 days
View Details
NAICS: 238220
New
Federal
CON | Z2DA | REPLACE CHILLER 1 B104 | 580-24-111 | SOLICITATION
Solicitation # 36C25626R0131
The Department of Veterans Affairs Network Contracting Office 16 is soliciting proposals for a firm-fixed-price construction project to replace Chiller 1 in Building 104 at the Michael E. DeBakey VA Medical Center in Houston, Texas. This project, identified as number 580-24-111, involves the demolition and removal of an inoperable 1,000-ton, 480V York chiller and its associated transformer, piping, and controls. The contractor will procure and install a new 1,000-ton, 4,160V water-cooled centrifugal chiller, specifically a Johnson Controls York Model YKOLO5K1CZR or approved equal using R-513A refrigerant, along with a new exterior 12.47kV-to-4,160V transformer, soft starter, and integration into the Metasys BAS. The scope also includes draining, cleaning, and chemically treating the water systems. The estimated magnitude of construction is between $2,000,000 and $5,000,000, with a performance period of 180 calendar days from the Notice to Proceed. This opportunity is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB), requiring offerors to be registered with SBA VetCert and SAM. The SDVOSB must perform at least 15 percent of the contract cost for personnel. Award will be based on the best value using a tradeoff procedure where past performance is significantly more important than price. Proposals must be submitted in two volumes, including a bid bond, and are subject to Davis-Bacon Act wage determinations and Buy American requirements. Performance and payment bonds will be required upon award. Final acceptance is contingent upon a series of inspections and tests, including insulation-resistance tests and verification of water quality compliance.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

about 17 hours ago

DEADLINE

in about 1 month
View Details
NAICS: 238220
New
Federal
J041--HVAC Repair
Solicitation # 36C25627Q0104
The Department of Veterans Affairs, through Network Contracting Office 16, has issued a Sources Sought Notice for market research to identify businesses capable of performing HVAC repairs on a Daikin VRF Heat Recovery Unit (HRU-1) located at the Fisher House 1st Floor of the Central Arkansas Veterans Healthcare System in Little Rock, Arkansas. The scope of work includes the recovery and restoration of refrigerant and the replacement of proprietary Daikin components, specifically the main PCB board, both inverter compressor boards, and inverter compressors 1 and 2. This notice is for planning purposes only and is not a solicitation for proposals or quotes; therefore, no contract will be awarded from this specific notice. Interested respondents must submit their capabilities statements via email to the designated contract specialist by 12:00 p.m. Central Time on Wednesday, November 4, 2026. Submissions must include a Unique Entity Identification number, any relevant qualifying certifications, and a mandatory letter of authorization from the original equipment manufacturer, Daikin. The requirement falls under NAICS code 238220 for Plumbing, Heating and Air Conditioning Contractors, with a size standard of 16.5 million dollars. Additionally, all parties must be registered and active in SAM.gov, and veteran-owned small businesses are reminded of their VETS-4212 reporting requirements.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

about 17 hours ago

DEADLINE

in 5 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS