6515--Thyroid Uptake System
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
The Department of Veterans Affairs, Network Contracting Office 20, is conducting market research to identify qualified small business concerns capable of supplying a Captus 4000e or equivalent thyroid uptake system, classified under NAICS code 334516 with a small business size standard of 1,000 employees. This sources sought notice is not a solicitation for quotations or pricing, but rather a non-binding effort to assess the availability of vendors meeting stringent technical requirements for a comprehensive nuclear medicine measurement system capable of thyroid uptake, wipe test, and bioassay functions with fully automated quality assurance, DICOM compatibility, and hospital-grade ergonomics. The equipment must feature a 2-inch NaI(Tl) scintillation detector with proper collimation, a 1024-channel MCA, a touch-screen interface on Windows 10 or 11, mobile articulating stand with secure storage, and robust reporting capabilities including PDF export and spectral data archiving. Respondents must demonstrate compliance with federal, state, and local codes and confirm their eligibility for small business programs including SDVOSB, VOSB, 8(a), HUBZone, WOSB, or SDB, along with OEM status, distributor authorization, GSA/FSS contract presence, and Buy American Act compliance. Interested parties are required to submit detailed capability statements including company name, point of contact, UEI, address, email, and responses to specific questions regarding business size certifications, product availability, delivery timelines, and regulatory adherence. Supporting documentation such as specifications, brochures, and experience summaries are encouraged but must not contain proprietary, classified, or sensitive information. Responses must be emailed to the designated VA contacts by 2:00 PM PDT on August 13, 2026, and failure to respond does not disqualify any firm from future solicitations, which will be officially posted on SAM.gov if a formal procurement is initiated. The VA will use all submitted information solely for market research to determine appropriate contracting strategies, including potential set-asides, and reserves the right to utilize responses for any legally permitted purpose without obligation to award a contract or compensate respondents.
General Info
Agency
NAICS
Place of Performance
Deptartment of Veterans Affairs Mann-Granstaff VA Medical Center, Spokane, WA, 99205-6485Set-Aside
Documents
(1)AI Contract Breakdown
Uniform Contract FormatWhat is UCF?
Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.
Timeline
Response Deadline
Organization & Contact Information
Full Description
1. General System Functionality Must be a comprehensive nuclear medicine measurement system capable of performing thyroid uptake measurements, wipe tests, bioassay measurements, and automated quality assurance functions. Must include a software-driven workflow that supports predefined protocols and customizable measurement sequences. 2. User Interface & Computer Requirements Must utilize a color touch screen user interface with a large-format display (minimum 20 inches for visibility during procedures). Must operate on a current, widely supported Windows OS platform. (VA current platform Windows 10 or 11) Must support generation of reports containing graphics, isotope spectra, and archived data, with ability to save or print reports in PDF format. 3. Detector & Measurement Specifications Thyroid Uptake Detector Must utilize a NaI(Tl) scintillation detector capable of precise uptake measurements. (Spec: 2 inch diameter NaI(Tl).) Must include a collimator meeting recognized nuclear medicine performance standards (e.g., ANSI or IAEA). Must include a physical measurement/alignment mechanism to ensure consistent detector to thyroid distance. Multichannel Analyzer (MCA) Must include an MCA with a minimum of 1024 channels. Must provide automated and manual calibration capabilities. Must support user defined and preset ROIs, live time, real time, and total count presets. Must support accurate count rate linearity ( 2% deviation up to at least 150,000 cps). Optional Well Counter Must support well counting for capsule/liquid dose formats utilizing a NaI(Tl) well detector. (Spec: 2 inch diameter NaI(Tl).) Must provide shielding sufficient for radiation safety and measurement accuracy (minimum 1 inch lead shielding). 4. Quality Assurance Capabilities Must provide fully automated QA tests including energy calibration, zero adjust, gain adjust, detector efficiency, resolution, chi square, constancy, and minimum detectable activity (MDA). Must include both automated and manual calibration options. 5. Thyroid Uptake Measurement Requirements Must support capsule and liquid dose formats. Must allow pre-dose and pre count measurement. Must include multiple predefined thyroid uptake protocols and allow custom protocol creation. 6. Wipe Test & Bioassay Capabilities Must support multi group wipe test setup and isotope identification with spectral display. Must flag wipe test results exceeding trigger levels. Must support bioassay monitoring for common isotopes (e.g., I 123, I 125, I 131). Must allow user defined action levels and produce individual and summary reports. 7. Connectivity / System Integration Requirements Must provide optional or integrated DICOM capability that can retrieve patient data and upload reports to hospital information systems. 8. Physical / Form Factor Requirements Must include a mobile, ergonomic stand with adjustable height and articulating detector arm capable of wide range motion (vertical travel and rotation). Must include secure storage for neck phantom and quality control sources. Must include cable management to maintain safe, clinical grade setup. Must include hospital-grade power configuration with isolation transformer. 9. Reporting & Data Archival Requirements Must allow reporting that includes full spectrum graphics and thyroid uptake time vs value graphs. Must permit archiving of measurement data and export in standard formats. The information above is intended to be descriptive, not restrictive, to indicate the quality of equipment that will be satisfactory. It is the responsibility of the interested source to demonstrate to the Government that the interested source can provide equipment that fulfills the required specifications. POTENTIAL SOURCES SHALL PROVIDE THE FOLLOWING INFORMATION IN THEIR RESPONSE: Mark if your firm is eligible for participation in one of the following small business programs. If so, please indicate the program:
[ ] yes [ ] no - Small Business (SB) [ ] yes [ ] no - HUBZone [ ] yes [ ] no - Small Business 8(a) [ ] yes [ ] no - Small Disadvantaged Business (SDB) [ ] yes [ ] no - Women-Owned (WO) Small Business [ ] yes [ ] no - Service Disabled Veteran Owned Small Business (SDVOSB) [ ] yes [ ] no - Veteran Owned Small Business (VOSB) [ ] yes [ ] no - Large Business [ ] yes [ ] no - Other (please specify) [ ] yes [ ] no Are you the Original Equipment Manufacturer (OEM)? [ ] yes [ ] no If not the OEM, are you an authorized distributor, and can produce a letter from the OEM? [ ] yes [ ] no Is this product available on your GSA/FSS or other GWAC Contract? If so, what is your contract number?_____________________ [ ] yes [ ] no Does your equipment conform to the Buy American Act and RFO 52.225-1? 52.225-1 Buy American-Supplies | Acquisition.GOV What is the estimated Delivery Date After Receipt of Order (ARO)? _____________
Please include the following information: Company Name: POC: UEI: Address: Email: In addition to providing the information requested above, responding companies are encouraged to include any relevant information (specifications, cut sheets, brochures, capability statement, experience etc.) to confirm the company s ability to meet the requirements outlined in this request. Disclaimer: This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. After reviewing the responses received, a pre-solicitation synopsis and solicitation may be published in Contract Opportunities (https://sam.gov/). Submit Capability Statements to: Department of Veterans Affairs, VISN 20 Attn: Krystal Weeks, no later than 2:00 PM (PDT), August 13, 2026. Responses must be submitted via e-mail to: krystal.weeks@va.gov and nco20supplyteam2@va.gov . Note: Do not include Proprietary, classified, confidential, or sensitive information in responses.