Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on February 17, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6515--VISN Cepheid GeneXpert Testing Supplies Sources Sought Notice

Closed
36C24526Q0294Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334516
New
Federal
Request for Information - DNA Buccal Collection Kits
Solicitation # 20270753FDDU
The Federal Bureau of Investigation (FBI) is issuing a Sources Sought Notice and Request for Information (RFI) under solicitation number 20270753FDDU to identify potential sources capable of providing DNA Buccal Collection Kits. These kits are used by the Laboratory Division's Biometrics Analysis Section to process DNA databasing samples for upload to the National DNA Index System (NDIS). This is a market research effort for preliminary planning purposes and does not constitute a formal request for proposal or a commitment to award a contract. Interested small and large businesses must submit a capability statement by November 16, 2026, to Contracting Officer Bryan Lane. The required kits must meet international testing laboratory standards and ISO 9000 accreditation. Each kit must include a color-printed FD-936 form on 100# Tag Stock paper, nitrile gloves, a pre-inked fingerprint pad, ink-removal wipes, and a drying envelope with a desiccant packet. A critical requirement is the use of matching 8-character alphanumeric barcodes (format code 128 or 93) across the FD-936 form, the collection device, and the outer kit envelope. The outer envelope must be a non-white, tamper-evident, self-adhesive poly or Tyvek material with a tamper tape closure. Additionally, vendors must demonstrate the capacity to maintain a minimum inventory of 100,000 kits for immediate shipment.
Division 0700

POSTED

about 11 hours ago

DEADLINE

in 26 days
NAICS: 334516
New
Federal
NOI - Service and Maintenance of Lorrca Machine (R
Solicitation # 75N98027Q00022
The National Institutes of Health (NIH), Office of the Director, Office of Acquisitions, is issuing solicitation 75N98027Q00022 as a Notice of Intent to award a non-competitive, firm-fixed-price purchase order for a one-year full-service maintenance contract for a Lorrca ektacytometer. The service will be performed at the NHLBI Sickle Cell Branch in Bethesda, Maryland, and is intended for Mechatronics USA LLC, the original equipment manufacturer's sole U.S. sales and service provider. The scope of work includes one annual on-site preventive maintenance visit involving optical system cleaning, laser alignment, and calibration, as well as all corrective repairs, labor, travel, non-consumable parts, and software support to ensure the instrument's optimal performance for Sickle Cell Disease research. The contract is conducted under FAR 12.603 and is not expected to exceed the simplified acquisition threshold. Key deliverables include a Quality Control certificate and field service report upon completion of maintenance. Invoicing must be processed monthly through the Invoice Processing Platform (IPP) using a three-way match. The associated NAICS code is 334516, and the requirement is not set aside for small business. Proposals must be submitted electronically to Nicholas Capobianco by November 5, 2026, and must include the offeror's Unique Entity Identifier, Taxpayer Identification Number, and business size certification.
National Institutes Of Health Olao

POSTED

about 11 hours ago

DEADLINE

in 15 days
NAICS: 334516
New
SLED
X-Ray Tube for XRF Spectrometer Equipment
Solicitation # 601440000053804
The Texas Department of Transportation is seeking an Invitation for Bid under solicitation number 601440000053804 to procure and install an X-Ray tube for a Rigaku Supermini X-Ray Fluorescence Spectrometer used by the Materials and Tests Division. The required component is a Rigaku Supermini 200 WDXRF Spectrometer X-Ray tube, specifically an end-window palladium type with a 200-watt target power rating, a maximum operating voltage of 50 kV, and a maximum operating current of 4.0 mA. All electrical items must comply with OSHA standards and bear appropriate UL, FMRRC, or NEMA listings. The contract will be awarded based on the best value, primarily considering the lowest price and the respondent's technical ability to meet the specified requirements. Responses are due by November 3, 2026, at 9:00 PM. Bidders must provide a signed response, their Employer Identification Number, and a detailed product description including the manufacturer and brand. Delivery must be F.O.B. destination freight prepaid and allowed to a designated TxDOT location, with a default delivery window of 14 calendar days if no specific lead time is provided. Payment will be issued via warrant or direct deposit within 30 calendar days of receiving a correct invoice. The procurement process includes strict compliance requirements regarding eligibility, anti-terrorism certifications, and the prohibition of collusion or gratuities.
Texas Department of Transportation

POSTED

1 day ago

DEADLINE

in 13 days
NAICS: 334516
New
SLED
Membrane Filters
Solicitation # 582-27-20191
The Texas Commission on Environmental Quality (TCEQ) is soliciting bids under solicitation number 582-27-20191 for the procurement of 60 packages of replacement membrane filters for use at agency-owned air monitoring stations. These filters are essential for collecting air monitoring data required by 40 CFR Part 58 for the US Environmental Protection Agency. The required filters must be hydrophobic Polytetrafluoroethylene (PTFE), chemically inert, and meet specific technical standards, including a 170 micron thickness, 5.0 micron pore size, 47 mm diameter, and 60 percent porosity, with a plain white smooth surface and an air flow rate of 9 liters per min centimeters squared. The reference model is Expo tech USA, Inc # 1183403 or an equivalent. Bids are due by November 04, 2026, at 2:00 PM CST and can be submitted via email to TCEQebid@tceq.texas.gov or physically time-stamped at the TCEQ. Awards will be based on the low line item bid, low total of line items, or a combination that serves the best interest of the state. Delivery is to be made to Austin, Texas, with a default delivery window of 14 calendar days if no other timeline is specified. The contract includes various Texas Government Code compliance requirements, including certifications against boycotting Israel or energy companies, prohibitions on business with foreign terrorist organizations, and adherence to COVID-19 vaccine passport prohibitions. Vendors must provide a Texas Identification Number System (TINS) number and an Employer Identification Number (EIN) to receive payment.
Texas Commission on Environmental Quality

POSTED

1 day ago

DEADLINE

in 14 days

General Info

NAICS

334516 - Analytical Laboratory Instrument Manufacturing

Place of Performance

VISN 5 Wide VA Medical Centers, MD, USA

Set-Aside

NONE

Documents

1

36C24526Q0294 VISN Cepheid GeneXpert Testing Supplies Sources Sought Notice

DOCX, Low prioritysources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
Contacts1 person available
OfficeLINTHICUM, MD, 21090, USA
Office AddressLINTHICUM, MD, 21090, USA
Contacts
Michael JonesContract Specialist

Full Description

Show more
Responses must be received no later than March 16, 2026, at 10:00AM EST. THIS SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS SOURCES SOUGHT NOTICE IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER: This Sources Sought Notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this Sources Sought Notice that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this Sources Sought Notice. SOURCES SOUGHT DESCRIPTION This is NOT a solicitation announcement. This is a sources sought notice only. The purpose of this sources sought notice is to gain knowledge of potential qualified sources and their size classification relative to NAICS 334516. Responses to this sources sought notice will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought notice, a solicitation announcement may be published. Responses to this sources sought notice are not considered adequate responses for a solicitation announcement. The Department of Veterans Affairs (VA), VISN 5 Network Contracting Office, is seeking sources that can provide Cepheid GeneXpert Testing Supplies for the VISN 5 Wide VA Medical Centers.
Statement of Work Scope: The Cepheid GeneXpert performs testing by utilizing the Polymerase Chain Reaction (PCR) method. This is a random-access analyzer that has capacity to perform 48 assays at any given time. It is a closed, self-contained, fully integrated and automated platform capable of producing accurate results in a timely manner with minimal risk of contamination.
The PCR testing methodology is confirmatory test detection of Coronavirus (CoV-2), Influenza (Flu), Respiratory Syncytial (RSV), Streptococcus A (Strep A), Staphylococcus aureus (SA), Methicillin-resistant Staphylococcus aureus (MRSA), Norovirus, Clostridioides difficile (C. diff), Carbapenemase (Carba), Multiplex Vaginal Panel (MVP), Chlamydia trachomatis (CT), and Neisseria gonorrhoeae (NG), Trichomoniasis (TV), Hepatitis (HCV), Mycobacterium Tuberculosis (MTB), and Rifampicin (RIF).
Test Kits required: Cepheid GeneXpert consumables: GXCARBAR-10 GXCDIFF/EPI-10 GXCT/NG-10 GXMRSA-NXG-10 XPRSTREPA-10 GXHCV-10 GXMRSA/SA-BC-10 GXMRSA/SA-SSTI-10 GXMTB/RIF-US-10 GXNOV-10 GXSACOMP-10 GXTV-10 XPRS-COV2-10 XPRS4PLEX-10 XPRSMVP-10 GXMPX-10
The Vendor shall provide, in accordance with all applicable federal, state, and local regulations, laws, and ordinances, and in accordance with the specifications outlined for accreditation certification if applicable, reagents/supplies/consumables/service negotiated on contract to enable VISN 5 laboratories to accurately and efficiently process microbiology identification of patient samples using the Cepheid GeneXpert PCR analyzers for a list of bacteria and viruses as required by sample submitted. The Vendor shall provide the ability to ship reagents on an As Needed basis to VISN 5 laboratories. The reagents should have the furthest expiration date possible, contractor will guarantee four months, and the VA can request the longest outdate available upon order. One lot number of products is requested per shipment. The Vendor shall provide the facilities with the most current Food and Drug Administration (FDA) approved reagents/supplies/consumables necessary for the microbiology testing of patient samples for the identification of bacteria and viruses. The reagents, validator, calibrators, supplies/consumables kits and service must be compatible with the Cepheid GeneXpert analyzers. The Vendor must acknowledge receipt of order within 24 hours and provided estimated shipping timeframe. The Vendor must be able to provide an emergency plan in case reagents are found to be defective and unsuitable for use at no additional cost. In the event that the any consumable, reagent, or other necessary item are found to be defective and unsuitable for use with the vendor's equipment, or they have failed to comply with the requirements for routine supply delivery, the vendor shall deliver the consumable supplies within a period of 24 hours after receipt of the verbal order for priority delivery from the facility. If either circumstance has occurred, the vendor shall deliver to the facility, in the most expeditious manner possible, without additional cost to the facility, the necessary consumables in sufficient quantity as required to allow operations of the Microbiology Laboratory equipment for one week (under normal Government test load volume) so testing is not delayed. If additional requests for emergency supply delivery is required by the Government, they shall be honored by the Contractor until the arrival at the laboratory of the monthly standing order/routine supplies delivery. The vendor shall reimburse the facility for the total reference laboratory costs/supplies related to tests sent to a referral laboratory when testing is not available through no fault of the facility due to reagent problems or any other product issues. The damage assessed shall be applied to the invoice in the form of a credit or deduction. The kits must be maintained and delivered following all Federal and State regulations as applicable.
Performance Period: Base plus four (4) Option years. Base year October 1, 2026 September 30, 2027 Option Year 1 October 1, 2027 September 30, 2028 Option Year 2 October 1, 2028 September 30, 2029 Option Year 3 October 1, 2029 September 30, 2030 Option Year 4 October 1, 2030 September 30, 2031
Type of Contract: This is a firm fixed price, Blanket Purchase Agreement (BPA) for all reagents, verification kits, Quality control material (excluding third party supplies), and consumables/accessories and shall be delivered upon the ordering facility.
Place of Performance: All VISN 5 sites may order from this agreement to include the following:
VA Maryland Healthcare System 10 N Greene St Baltimore, MD 21201
Beckley VA Medical Center 200 Veterans Ave Beckley WV 25801-6444
Louis A. Johnson VA Medical Center 1 Medical Center Drive Clarksburg WV 26301
Hershel "Woody" Williams VA Medical Center 1540 Spring Valley Drive Huntington WV 25704
Martinsburg VA Medical Center 510 Butler Avenue Martinsburg WV 25405
Washington DC VA Medical Center 50 Irving Street, NW Washington DC 20422
------------------------------------------------------------------------------------------------------------------------------- The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. If you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below. If you are interested and are capable of providing the sought-out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc. (2) Is your company considered small under the NAICS code identified under this RFI? (3) Are you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items? (4) If you are a small business and you are an authorized distributor/reseller for the items identified above (or equivalent product/solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? (5) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number. (6) If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract? (7) Please provide general pricing for your products/solutions for market research purposes. (8) Please submit your capabilities in regard to the salient characteristics being provided and any information pertaining to equal to items to establish capabilities for planning purposes? *** Submissions addressing Section (8) should show clear, compelling, and convincing*** evidence that all equal to items" meet all required salient characteristics. Responses to this notice shall be submitted via email to Michael.Jones16@va.gov. Telephone responses shall not be accepted. Responses must be received no later than March 16, 2026, at 10:00AM EST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.

More opportunities from Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)

Same awarding agency

NAICS: 541310
New
Federal
C1DA--Renovate Specialty Clinics on 2nd
Solicitation # 36C24526R0101
Solicitation 36C24526R0101 is a request for Architect/Engineer services to provide a turnkey design package for the renovation of approximately 16,530 square feet of specialty clinic space on the second floor of the Beckley VAMC in West Virginia. The project focuses on creating an updated central check-in and waiting area, improving wayfinding and traffic flow to support a one-stop care approach, and upgrading systems in a facility originally constructed in the 1950s to meet current building codes and VA guidelines. Key deliverables include construction drawings across all disciplines, schematic designs, life-cycle cost analysis, preconstruction risk assessments, and detailed phasing and infection control plans to manage work within an occupied facility. While the A/E service value is not specified, the resulting construction budget is not to exceed 19,912,000 dollars. This procurement is a 100 percent Service-Disabled Veteran-Owned Small Business set-aside conducted under the Brooks Act. Selection is based on qualifications, with a shortlist of three to five firms chosen for interviews. The primary evaluation factors are professional qualifications, specialized experience in healthcare renovation, and past performance, followed by capacity to accomplish the work, organization and quality control, and geographic knowledge of the locality. Interested firms must be registered in SAM and certified in the SBA Veteran Small Business Certification database. The submission deadline for SF 330 qualifications packages has been extended to November 13, 2026, at 2:00 PM EST, with submissions required in PDF format and limited to 5MB per email attachment.
Architectural Services

POSTED

about 11 hours ago

DEADLINE

in 23 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS