This Sources Sought opportunity from Department Of Veterans Affairs was posted on January 21, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6530--BK HTM Ceiling Lift RFI

Closed
36C24525Q0228Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

Department of Veterans Affairs Beckley VAMC TBD 200 Veterans Ave, Beckley, WV, 25801, USA

Set-Aside

NONE

Documents

1

36C24525Q0228.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
Contacts1 person available
OfficeLINTHICUM, MD, 21090, USA
Office AddressLINTHICUM, MD, 21090, USA

Full Description

Show more
Sources Sought Notice Sources Sought Notice Page 6 of 6 Sources Sought Notice *= Required Field Sources Sought Notice Page 1 of 6 THIS REQUEST FOR INFORMATION IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. This is a Request for Information (RFI)/Sources Sought Notice (SS), this is not a Request for Quotes (RFQ) or Request for Proposals (RFP). No formal solicitation document exists at this present time. This is not a solicitation announcement. The purpose of this Sources Sought notice NAICS 339113 - Surgical Appliance and Supplies Manufacturing PSC 6530 hospital furniture, equipment, utensils, and supplies NAIC size standard of 800 employees for the Beckley VAMC. Responses to this Sources Sought notice will be utilized by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought notice, a solicitation announcement may or may not be published in SEWP, FedBizOpps (FBO) or GSA ebuy. REQUESTED INFORMATION Responses to this Sources Sought notice shall also include: company name, address, point of contact, if applicable contract number, product brochures, place of manufacturer, NAIC/PSC codes, Sam Uei number, and business size. If vendor is interested and capable, and can provide the required product/service, please provide the requested information for questions 1-15 as indicated below: Is this service/product priced on vendor s GSA/SEWP/FSS/NAC/SAC contract? Yes/No If yes, provide vendor government contract number or leave blank? Is this service/product open market pricing? Yes/No Is open market priced online? Yes/No Provide vendor s business size status and representations NAIC and PSC code? Does vendor have capability, product, and interest for Brand name Patient lift system end item product requirement? Yes/No Does vendor have capability, product, and interest of an equal Patient Lift System end item product? Yes/ No If equal product end item; provide equal product name/model/ product brochure/ specification sheet/warranty/life expectancy/maintenance requirements information. Where is brand name end item patient lift system product place of manufacturer,- complete table below? Where is equal end item patient lift system product place of manufacturer- complete table below? Is interested vendor LG/SB/SDVOSB/VOSB (which BS) manufacturer or (which BS) authorized distributor of an equal domestic patient lift system end item product? Is interested vendor LG/SB/SDVOSB/VOSB (which BS) manufacturer or (which BS) authorized distributor of brand name a domestic patient lift system end item product? Is interested vendor LG/SB/SDVOSB/VOSB (which BS) manufacturer or (which BS) authorized distributor of nondomestic patient lift system brand name end item product? Is interested vendor LG/SB/SDVOSB/VOSB (which BS) manufacturer or (which BS) authorized distributor of nondomestic patient lift system equal end item product? Provide 2024 signed copy authorized distributor letter if vendor is not the manufacturer. SOW GENERAL INFORMATION BRAND NAME SOW PATIENT LIFT SYSTEM INSTALL/DEINSTALL OR EQUAL PURCHASE AND AUTHORIZED INSTALLER REQUIREMENT Minium Technical Requirement 2.7.1. Fixed Ceiling Lift 2.7.1.1. Manual Traverse 2.7.1.2. Lift Motor: 24 Volt 2.7.1.3. Lift Capacity at least 600 lbs 2.7.1.4. Unit weight max 45 pounds 2.7.1.5. The Patient Lift unit must be able to collect and report the following data at each LCD Display unit: 2.7.1.5.1. lift Life total count 2.7.1.5.2. Total number of load weighing more than 330lbs 2.7.1.5.3. Number of lifts in the last 7 (seven) days 2.7.1.5.4. Average number of lifts per week 2.7.1.6. The Patient Lift unit must also be able to report the following additional safety / maintenance data via USB connection to a laptop / tablet: 2.7.1.6.1. Lifting strap life total Count 2.7.1.6.2. critically low battery life count 2.7.1.6.3. The total number of weightings 2.7.1.6.4. Total lifting time 2.7.1.7. Software transfer data must operate with VA existing IT infrastructure. (laptop / tablet USB/cord connection solution). 2.7.1.8. Wi-Fi compatibility will NOT be required in any Patient Ceiling Lift. 2.7.1.9. Requires emergency stop function 2.7.1.10. Requires emergency lowering capability 2.7.1.11. Requires manual lowering capability 2.7.1.12. Rails must provide continuous in-rail charging 2.7.1.13. Lifts must be safe for bathroom use 2.7.1.14. Requires integrated compatible scale module 2.7.1.15. Requires lowest position to reach the floor MINIMUM TECHNICAL REQUIREMENT 2.7.2. Bariatric Ceiling Lift 2.7.2.1. Manual Traverse 2.7.2.2. Lift Motor: 24 Volt 2.7.2.3. Lift Capacity at least 1000 lbs 2.7.2.4. Unit weight Max 45 pounds 2.7.2.5. The Patient Lift unit must be able to collect and report the following data at each LCD Display unit: 2.7.2.5.1. Lifts total count 2.7.2.5.2. Total number of load weighing more than 330lbs 2.7.2.5.3. Total Count of lifts in the last seven days 2.7.2.5.4. Average count of lifts per week 2.7.2.6. The Patient Lift unit must also be able to report the following additional safety / maintenance data via USB connection to a laptop / tablet: 2.7.2.6.1. Lifting strap life 2.7.2.6.2. critically low battery life count 2.7.2.6.3. The total weightings count 2.7.2.6.4. Total lifting time/hours 2.7.2.7. Software transfer data must operate with VA existing IT infrastructure. (laptop / tablet/cord/ USB connection solution). 2.7.2.8. Wi-Fi compatibility will NOT be required in any Patient Ceiling Lift. 2.7.2.9. Requires emergency stop function 2.7.2.10. Requires emergency lowering capability 2.7.2.11. Requires manual lowering capability 2.7.2.12. Rails must provide continuous in-rail charging 2.7.2.13. Lifts must be safe for bathroom use 2.7.2.14. Must include integrated scale 2.7.2.15. Must be able to reach the floor in its lowest position 2.7.3. Accessories / Supplies 2.7.3.1. Disposable Slings one of each size (M, L, XL, Bariatric, Repositioning, Limb) for each installed lift. 2.7.3.2. Reusable Slings (M-8 Qty, L-8 Qty, Repositioning-22 Qty) 2.7.3.3. Tracks/rails for each lift 2.8.1.1.1. Phased installation/destination delivery throughout the hospital to minimize patient impact. Vendor to coordinate with COR for room downtimes and access. 2.8.1.2. Travel cost and time 2.8.1.3. Inspection of existing rails and correction of any deficiencies 2.8.1.4. Provide structural support calculations for each room/lift system 2.8.1.5. Ceiling lift installation and certification 2.8.1.5.1. To be completed in accordance with VA Installation or Relocation Checklist for Ceiling Mounted Patient Lifts (Attached) 2.8.1.6. Vendor must follow all VHA Infection Control Risk Assessment (ICRA) and VHA Pre-Construction Risk Assessment (PCRA) protocols. 2.8.1.6.1. This will include but will not be limited to: 2.8.1.6.1.1. HEPA filters, HVAC isolation, block off/seal air vents, and sticky mats at the entrance of work site 2.8.1.6.1.2. Specific requirements to be determined post-award on a room by room basis. 2.8.1.7. Vendor is responsible for all incidental drywall repairs, repainting of walls that is required to install structural supports 2.8.1.8. Vendor is responsible for running additional electrical lines as necessary. 2.8.1.9. VA Electricians will handle lock out tag out procedures for any existing lines. 2.8.1.10. Vendor is responsible for deinstall for existing equipment Removal of existing lift systems, tracks, and etcc that is being replaced on 6 floors. 2.8.1.11. Vendor shall destination deliver all equipment and track equipment to the Beckley VAMC when the (1st-6th floors) sites are ready for installation. 2.8.1.12. Vendor is responsible to track and manage equipment until it is fully operational and installed. 2.8.1.16. The vendor shall remove all related shipping debris and packing from the VA facility. 2.8.1.17. Vendor delivery shall be completed with COR approval between 8:00 a.m. and 3:30 p.m. Monday Friday. All federal holidays are excluded. 2.8.1.18. Vendor delivered materials to job in manufacturer's must be in original sealed containers with PO number on the outside of box. 2.8.1.19. Vendor is responsible for package damage or deterioration during shipment, handling, storage, and until fully operational installation. 2.8.1.20. Vendor is responsible to store products in dry condition inside enclosed facilities until ready for delivery and install. Line item No. Country of origin - - - NOTES All Capability Statements and Responses RFI questions in this Sources Sought notice shall be submitted via email contact@example.gov Telephone, Fax, or any other form of communication inquiries will not be reviewed or accepted in response to this Sources Sought notice. Responses to this Sources Sought notice must be received no later than 1/28/25 at 1:00 p.m. (Eastern Standard Time). This Sources Sought notice is to assist the VA in determines sources only. A solicitation is not currently available. If a solicitation is issued, it may or may not be announced at a later date, and all interested parties shall respond to that solicitation announcement separately from the responses to this Sources Sought notice. DISCLAIMER This Request for Information (RFI) is issued for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked a proprietary will be handled accordingly in accordance with (IAW) Federal Acquisition Regulation (FAR) 15.201(e), RFIs may be used when the Government does not presently intend to award a contract, but wants to obtain price, delivery, other market information, or capabilities for planning purposes. Responses to these notices are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses incurred associated with responding to this RFI. End of Notice

More opportunities from Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)

Same awarding agency

NAICS: 561730
New
Federal
Snow and Ice Removal Management Services
Solicitation # 36C24527Q0041
The Department of Veterans Affairs is soliciting quotes for on-call, 24/7 snow and ice management services at the Beckley VA Medical Center in West Virginia. The contract period of performance runs from November 1, 2026, to April 30, 2027. The selected contractor will be responsible for providing all labor, equipment, and materials to perform plowing, clearing, deicing, pre-treatment, and snow relocation across approximately 11 acres, including roads, parking lots, garages, sidewalks, and emergency access routes. Services must follow a three-tier priority scheme to ensure continuous vehicular and pedestrian access, with a strict prohibition on using sodium chloride on parking garage decks and ramps. This is a total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). Award decisions will be based on a comparative evaluation of technical capability, past performance over the last three years, and pricing reasonableness, rather than a low-price technically acceptable process. Offerors must submit their proposals by October 29, 2026, at 3:00 PM EST. Key requirements include continuous monitoring of the National Weather Service, submission of Safety Data Sheets for all deicing products, and adherence to Service Contract Act wage determinations for West Virginia. Invoicing must be processed electronically via the FSC e-Invoice Payment system.
Landscaping Services

POSTED

about 19 hours ago

DEADLINE

in about 12 hours
View Details
NAICS: 561210
New
Federal
J044--NOTICE OF INTENT TO SOLE SOURCE Baltimore VAMC Steam System Preventive Maintenance from Vicinity Energy Baltimore Corporation
Solicitation # 36C24527Q0048
The Department of Veterans Affairs is issuing a Notice of Intent to Sole Source for an open market award to Vicinity Energy Baltimore Corporation to provide annual steam system preventive maintenance at the Baltimore VA Medical Center. This requirement, classified under NAICS code 561210 and PSC J044, is driven by the fact that the facility's steam equipment is directly connected to the district steam distribution system owned and operated by Vicinity Energy. Due to this interconnected configuration and the proprietary operational data involved, the government identifies Vicinity Energy as the sole source capable of ensuring the reliable operation of the system without risking the broader distribution network. The scope of work requires a two-person crew to provide eight hours of service every two weeks, totaling 416 labor hours per year. Key responsibilities include steam trap surveys, cleaning pressure-reducing valves, inspecting heat exchangers, and ensuring proper water chemistry and meter operation. The contractor must supply all necessary parts meeting original manufacturer specifications and provide emergency call-back services with a technician on-site within five hours of notification. The anticipated period of performance is one year from the award date, with the possibility of option-year extensions. Interested vendors may submit capability statements to Contract Specialist Patricia Thai by 11:00 AM EST on November 10, 2026, referencing announcement number 36C24527Q0048. These submissions will be used solely to determine if the procurement will be conducted on a competitive basis. All work will be performed at the Baltimore VAMC, adhering to strict VA security, safety, and infection control requirements.
Facilities Support Services

POSTED

about 19 hours ago

DEADLINE

in 12 days
View Details
NAICS: 423440
New
Federal
J072--JR/BP POTS AND PANS ROOM | WASHINGTON DC VAMC
Solicitation # 36C24527Q0043
The Department of Veterans Affairs is seeking a contractor for the emergency procurement, delivery, and factory assembly of commercial-grade kitchen equipment for the Nutrition and Food Services Pot and Pan Washing Room at the Washington DC VA Medical Center. This firm-fixed-price acquisition is driven by critical infection control and physical environment deficiencies identified during a June 2026 Joint Commission survey. The required equipment includes a custom Aerowerks two-compartment sink system with a drainboard, a Salvajor food waste disposer, and a Hobart TurboWash II pot scrubber. All equipment must be NSF listed, commercial grade, and compliant with Joint Commission, CMS Conditions of Participation, and FDA Food Code standards. The contractor is responsible for freight, uncrating, and delivery to the facility within 60 calendar days of award. A qualified Aerowerks technician must perform the on-site assembly within 14 days of delivery to preserve the manufacturer warranty. Strict safety and cleanliness protocols are in effect, including the requirement for hot work permits for welding and the immediate removal of all packaging and metal debris to prevent food service contamination. Payment will be issued via a single electronic invoice on a Net 30 basis following the COR's written acceptance of the installed and inspected equipment.
Other Commercial Equipment Merchant Wholesalers

POSTED

3 days ago

DEADLINE

in 6 days
View Details
NAICS: 238210
New
Federal
J061--INTENT TO SOLE SOURCE AWARD TO EATON CORP - BASE YEAR MAINTENANCE AND SERVICE CONTRACT FOR 8 UPS HERSHEL WOODY WILLIAMS VAMC
Solicitation # 36C24527Q0046
The Department of Veterans Affairs intends to award an open market sole source contract to Eaton Corporation (UEI: NP3NSFVMNUM3) for a one-year service and preventative maintenance agreement. The contract covers eight specific Eaton UPS systems located at the Hershel Woody Williams VA Medical Center in Huntington, West Virginia. The scope of work includes a Flex Plan consisting of two UPS and two battery preventive maintenance checks for all eight systems. This procurement is classified under NAICS code 238210 for Electrical Contractors and Other Wiring Installation Contractors and PSC J061 for the maintenance and repair of electric wire and power distribution equipment. The government is pursuing a sole source award because Eaton Corporation is the original equipment manufacturer and the only authorized provider of the proprietary service software, repair documentation, and materials required for 3-phase Eaton UPS products. As an ISO9001 certified supplier, Eaton does not certify or support third-party providers for these specific products. This notice is published in accordance with FAR 5.101(a) and FAR 12.102. Interested vendors may submit capability statements to Contracting Officer William Pratt by November 12, 2026, at 10:00 AM ET, referencing announcement number 36C24527Q0046 to determine if the requirement will be competed.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

3 days ago

DEADLINE

in 14 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS