Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Department Of Veterans Affairs was posted on January 25, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6530--HOSPITAL BEDS VAMC ASHEVILLE NC SDVOSB SET-ASIDE

Awarded
36C24623Q0207Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

Solicitation 36C24623Q0207 is a Department of Veterans Affairs request for the procurement of 176 replacement hospital beds for the Charles George VA Medical Center in Asheville, North Carolina. This SDVOSB set-aside contract seeks Stryker brand or equal equipment, including Med-Surg, Long Term Care (CLC), and ICU beds, as well as powered clinical chairs. The procurement emphasizes standardized bedframes across levels of care with specific requirements for dimensions to ensure elevator and door compatibility, integrated bed scales, and advanced safety features such as three-zone bed exit alarms and rapid-release CPR functions. Technical specifications require that Med-Surg and ICU beds feature battery-operated powered drive systems, while the 90 CLC beds do not. ICU beds must include high-acuity capabilities such as Continuous Lateral Rotation Therapy, pulmonary therapy modes, and Electronic Medical Record compatibility. All beds must support a maximum working weight of 500 pounds and utilize mattresses incorporating gel technology and low air loss capabilities with a 10-year warranty. Clinical chairs must be powered with stand-assist and transfer capabilities. Offerors are permitted to bid on individual line items rather than the entire package.

General Info

Contract Value

$4,236,161.83

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

VA, USA

Set-Aside

NONE

Award Issued Date

Documents

2

Amendment 0001 to Solicitation 36C24623Q0207

DOCX, High priority: read this firstamendment
High

Solicitation 36C24623Q0207 - Hospital Beds for VAMC Asheville

DOCX, High priority: read this firstrfq
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

2 updates
PhaseAwarded
Posted

Presolicitation

Notice updated

Notice details unchanged. Attachments may have changed.

Type Changed

Presolicitation → Solicitation

Notice updated

Response deadline time changed from 5:00 PM UTC to 7:00 PM UTC on Feb 7, 2023. The notice description changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 246-NETWORK Contracting Office 6 (36C246)
Contacts1 person available
OfficeHAMPTON, VA, 23667, USA
Office AddressHAMPTON, VA, 23667, USA
Contacts
John P HarmsenContract Specialist

Full Description

Show more
36C24623Q0207 Page 1 of Page 1 of 6 Page 1 of Salient Characteristics Update Questions and answers are at the end Transaction #: Functions to be performed; Replace 176 hospital beds Essential physical characteristics; Dimensions (if applicable) Standardized bedframe across all levels of care to include Long Term Care, Med Surg, and ICU beds. Acute CareLong Term Care (CLC) and Med-Serg bed Salient Characteristics Minimum length of bed deck is 84 inches or lessto accommodate standard mattress. Must not exceed 93 inches total bed length to support elevator transport. Built-in Bed Extender requiring no additional attachments increasing length of bed. Minimum width of bed deck to accommodate sleep surfaces of 35 inches or greater compatible with the bedframe. Total width Must not exceed 42 inches to accommodate the doors in the CLC. Bed deck (top of deck) can be lowered below 15 inches from the floor. Nurse Call, Universal TV and Lighting controls must be accessible through the bed. Bed must have three zone bed exit alarm system Bed Exit alarms must be controlled from the footboard. Bed Exit Alarm must have a local audible alarm and one which will sound via the nurse call system or flashing call light over the door and be capable of wireless communication to nurse-patient communication devices. Bed exit alarm status has visible indicator from distance. When Bed alarm is set, a foot end colored light indicator visible from a distance indicating that that the bed is also in a safe position with the bed exit alarm on, the side rails up, bed in the lowest position and brakes are set. Alert will go off if any of these safety items are compromised. Bed alarms will include capability to customize alarms. Bed exit alarm status connection to nurse call system allows for central monitoring of alarm status. CPR function/quick release is clearly marked, at the head of the bed, and is not power dependent. The CPR function must be dampened to prevent staff injury and accessible without moving patient or side rails. The CPR function must be engaged using one hand and a one-step activation. When CPR is activated, the head of bed must go completely flat in 5 seconds or less. the bed must have automatic night lights located underneath the bed for safer patient egress. Integrated Bed scale with access on the footboard of the bed for staff efficiencies. Bed scale +/- 1% accuracy of patient weight. Update To: Bed scale shall provide accurate patient weight regardless of patient or bed position Bed Frame has IV Pole Holders (2 at head of bed) Two auxiliary AC outlets near foot of bed, the auxiliary outlets should not be bed power dependent and must be angled and/or covered to prevent fluid intrusion into the outlet. Bed must have integrated battery backup system sufficient to power transport and so controls can still be accessed if power is lost. Central electronic braking system with brakes activated from caregiver controls. Bed braking system can be also set and released by foot pedal located at head and foot of bed. Bed must accept a variety of surfaces/mattresses All surfaces should be accessible and able to be cleaned with standard hospital grade disinfectants Capable of transporting at any height Movements must include Trendelenberg/Reverse Trendelenberg. Movement must also include automated Vascular foot positioning (i.e., no operator lifting of foot of bed deck). Bed must support a maximum working weight of 500 pounds and bed will support attachment of single bar patient helper traction equipment with a weight capacity to hold 500 lbs. Minimum 5 casters and minimum 5-inch bed clearance under frame Central steering system Bed must accommodate evacuation sleds Siderails, in addition to meeting entrapment standards, must maintain a safe rail to floor gap to avoid staff foot injury. 61 Med-Serg Beds must have a battery-operated powered drive system for ease of transport. This requirement is not applicable to the 90 CLC (long-term) beds. Mattresses must incorporate GEL technology and low air loss capability and an included 10year warranty. Controls may be a combination of integrated control panels on side rails and footboard controls. Two accessory outlets: must be covered or angled for prevention of contamination Add-in: Beds must have a cable free solution for bed exit alarm and nurse call through the Nurse call System Add-in: Beds must have a built-in FIPS certified wireless radio capable of communicating directly with a 3rd party solution such as Vocera Engage ICU Bed The ICU Bed must meet national safety standards regarding interface of both patient and caregiver, with particular attention to FDA side rail and entrapment issues. Reference: FDA / Hospital Bed System Dimensional and Assessment Guidance to Reduce Entrapment ICU Bed shall support Patient Safety as outlined by the Institute of Medicine. ICU Bed shall have the capacity to sustain patients up to and including 500 pounds. The ICU Bed shall be equipped with an In-bed scale, Nurse Call, Universal TV, Pre-set and customizable Continuous Lateral Rotation Therapy (CLRT) The ICU Bed/Mattress shall have mechanism/technology that addresses weight-based pressure redistribution, shear, friction, excess heat removal from the skin surface and moisture, manage microclimate and maintain patient position when head of bed is raised and lowered to reduce shear. Low air loss Mattress that addresses up to stage 4 ulcers. The ICU Bed/Mattress shall possess an antimicrobial technology, which protects the surface against stain. The ICU bed shall be capable of descending to at least 16 from floor for easy egress, chair egress, Trendelenburg and reverse Trendelenburg with angle indicator The ICU Bed shall be Electronic Medical Record Compatible with a bed exit patient monitor. The ICU Bed shall have controls on both side rails and footboard with built-in Help screen with tutorial to offer control and access for caregivers. Enhanced surface system that combines pulmonary and pressure relief therapy modes. The ICU Bed shall be equipped with the following: Mounted IV Poles, Integrated or attachable Oxygen Tank Carrier, Built-in X-Ray Sleeve, Low Air Loss therapy, Bed Scales, Retractable foot mechanism, integrated power outlet. The ICU bed shall have a Motorized Drive with Variable Speed Control Mechanism. The ICU bed/mattress shall have Continuous Lateral Rotation Therapy without blower box The ICU bed/mattress shall have weight-based pressure redistribution in any bed position The ICU bed/mattress shall have Digital Head of bed angle indicator and alarm The ICU bed/mattress shall have 3 mode bed exit sensors with alarm silence and alarm suspend mode The ICU bed/mattress shall have One-button patient repositioning support The ICU bed/mattress shall have Turn assist The ICU bed/mattress shall have manual bed retraction and extension The ICU bed/mattress shall have Hands free emergency CPR and Trendelenburg The ICU bed/mattress shall have History data on patient weight, head of bed elevation, chair position, and pulmonary therapies The ICU bed/mattress shall have Therapy reminders The ICU shall be no higher than 15 inches from the floor when fully lowered. The ICU bed/mattress shall have Safety stop and alarm for pulmonary therapies when side rails are down Clinical Chair Must be powered Must have stand assist Must be capable of the following positions: Stand Assist Recline Upright Full-Flat Transfer Must have dual-sided, lighted, care-giver controls Must have integrated exit alarm Must have dual-sided patient control with lock-out function Must have adjustable height to a minimum of 61 inches Must have pivoting arm rests Must include options tray Must have a one-touch braking system Must have a weight capacity of 350 pounds Must have minimum 3.5 casters Must have maneuverability handles on both sides Questions question: For the (90) CLC beds, do they need to have the drive system as well? The Acute Care Bed Salient Characteristics state that the beds must have a battery-operated powered drive system for ease of transport. - We assume the CLC beds fall under the Acute Care Bed characteristics. However, during the Bed Fair, we were told by the facility that the CLC beds do not need the powered drive system. Answer: No, the (90) CLC beds do not need the drive system and we d prefer them not to so that the bed height may be lowered farther. However, MedSurge and ICU must have the drive units. Question and Answer Is this solicitation an ALL or NONE, meaning we need to bid on all line items? Bid what you can. Is percussion and vibration required for the pulmonary therapies on the ICU Beds? Not required Is full chair foot egress required on the ICU Beds? Not required Is powered push of a button length extension required on all beds? Not required Is it required to have integrated surfaces to prevent blower boxes on the footboard of beds? Not required Is it acceptable to have controls on the siderails at point of care instead of footboard? It is not preferred by clinical staff to have controls on siderails at point of care due to increased COVID exposure and higher potential to disrupt a patient that is sleeping. Is it acceptable to have powered air & nonpowered air surfaces instead of gel? No, the surfaces need to be gel but could be a combination of both air and gel, where air can be added for something like wound care, but the gel allows for a solid foundation without power

More opportunities from Department Of Veterans Affairs → 246-NETWORK Contracting Office 6 (36C246)

Same awarding agency

NAICS: 238220
New
Federal
RENTAL OF TWO CHILLERS FOR ONE YEAR
Solicitation # 36C24627Q0086
Solicitation 36C24627Q0086 is a request for a firm-fixed-price contract from the Department of Veterans Affairs for the one-year rental of two air-cooled chillers, specifically 100-ton and 400-ton units, including associated hoses. The equipment will be installed at the Charles George VA Medical Center in Asheville, North Carolina, to provide uninterrupted cooling services to Building 15 and Building 47. The period of performance is scheduled from December 11, 2026, to December 10, 2027. The contractor is responsible for the safe installation, operation, and routine maintenance of the units, which includes replenishing coolant and verifying electrical systems. Key deliverables include consistent cooling services and the submission of monthly maintenance reports. This procurement is a 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS codes 238220 and 238990. Award decisions will be based on the most advantageous offer, evaluating technical capability, past performance within the last three years, and price. Technical evaluations will focus on the offeror's ability to comply with HIPAA, VA criteria, NFPA, OSHA, and local building codes, as well as the quality of their contingency plans. Quotes must be submitted via email to the contracting office by November 10, 2026, and must include a signed Standard Form 1449, pricing schedules, and verification of SDVOSB status.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

1 day ago

DEADLINE

in 11 days
View Details
NAICS: 541380
New
Federal
F103--D AND D LABORATORY STEAM & WATER TESTING
Solicitation # 36C24627Q0096
Solicitation 36C24627Q0096 is a request for quotes issued by the Department of Veterans Affairs Network Contracting Office 6 for laboratory steam and water testing services. The contract supports the Durham VA Medical Center and its Community Based Outpatient Clinics in Greenville and Garner, North Carolina. The primary objective is to ensure that critical and utility water systems used in sterile processing services meet the rigorous standards set by the National Program Office for Sterile Processing Service and the Office of Healthcare Environment and Facilities Program. Required services include monthly sampling and testing for endotoxins, bacteria, pH, conductivity, alkalinity, and total hardness. This opportunity is a total set-aside for certified Veteran-Owned Small Businesses (VOSB) under NAICS code 541380. The contract structure includes a base period from November 10, 2026, to November 9, 2027, with multiple option periods extending through November 9, 2031. Award will be based on the Lowest Price Technically Acceptable (LPTA) method, evaluating offerors on their technical and management approach, capability to perform, and a history of at least two similar contracts completed within the last three years. Contractors must adhere to strict safety and quality standards, including OSHA and NFPA regulations, and provide calibration certifications for all test equipment traceable to a national standard. Invoicing must be submitted monthly in arrears through the OB10 e-Invoicing network. The deadline for response is November 9, 2026, at 9:00 AM EST.
Testing Laboratories and Services

POSTED

1 day ago

DEADLINE

in 10 days
View Details
NAICS: 811210
New
Federal
2-WAY RADIO MAINTENANCE FOR SALISBURY NETWORK
Solicitation # 36C24627Q0055
Solicitation 36C24627Q0055 is a total small business set-aside for the Department of Veterans Affairs to obtain inspection, maintenance, and repair services for the two-way radio system (call letters KAO-497) serving the Salisbury VA Medical Center and the Charlotte and Kernersville Health Care Centers in North Carolina. The scope of work includes upgrading the current system to Motorola Capacity Max, providing three FB-type exclusive channels for wide area coverage, and maintaining NC state law enforcement and medical VIPER frequencies. The contractor must adhere to a strict emergency response protocol, requiring a phone response within one hour and on-site arrival within four hours, 24/7/365. The contract is structured with a base year from January 1, 2027, through December 31, 2027, and four subsequent option years, with a total performance period ending December 31, 2031. Award will be based on a best value determination considering technical capability, past performance, and price, following Simplified Acquisition Procedures. Technical requirements include maintaining detailed maintenance and pager logs and complying with OSHA Bloodborne Pathogens Standards. Invoicing is handled monthly in arrears via the VA Electronic Invoice Presentment and Payment System. Quotes must be submitted to Amy Balicat by the specified deadline and include a technical proposal, past performance references from the last five years, and a separate price schedule.
Electronic and Precision Equipment Repair and Maintenance

POSTED

1 day ago

DEADLINE

in 17 days
View Details
NAICS: 236220
New
Federal
Z1DA--RENOVATE WARDS 3 EAST & 3 WEST
Solicitation # 36C24627Q0105
The Department of Veterans Affairs, Network Contracting Office 6, is conducting market research via a Sources Sought Notice to identify qualified contractors for the renovation of Wards 3 East and 3 West in Building 47 at the Charles George VA Medical Center in Asheville, North Carolina. This planning effort seeks to determine the best procurement strategy and potential set-aside status for a future one-time Firm-Fixed Price contract with a magnitude exceeding 10 million dollars. The project falls under NAICS code 236220 and involves comprehensive demolition and renovation, including structural work, the upgrade of architectural, mechanical, electrical, plumbing, fire protection, and telecom systems, and the abatement of lead-based paint and asbestos. Qualified respondents must demonstrate the ability to implement ICRA measures, infection control barriers, and construction safety enclosures while complying with VA, Federal, State, NFPA, and Life Safety codes. Key requirements include providing an on-site OSHA Competent Person, ensuring all personnel have OSHA 10/30 certification, and utilizing certified installers for firestopping. Interested firms must submit a capability statement of no more than 10 pages by November 12, 2026, detailing their socioeconomic status, bonding capacity, safety programs, and relevant healthcare renovation experience from the last five years. Registration in the System for Award Management and the VetCert database is required for applicable entities.
Commercial and Institutional Building Construction

POSTED

1 day ago

DEADLINE

in 13 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine