654-100-005-01 | Upgrade Computer Room Fire Protection

Open
654-100-005-01State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Illinois Emergency Management Agency is seeking an Architect/Engineer (A/E) for the upgrade of the computer room fire protection system at the Emergency Operations Center in Springfield, Sangamon County. The project involves the full replacement of the existing pre-action fire protection system with a new clean agent system. The A/E is responsible for coordinating all telecommunications and networking requirements with the Department of Innovation & Technology and ensuring the design complies with the Illinois Stretch Energy Code where applicable. Additionally, the A/E must identify and apply for all eligible utility incentive programs, energy grants, and rebates to support the project. The total estimated project cost and appropriated amount are $580,200. The A/E is required to maintain $250,000 in professional liability insurance and is held responsible for providing a design that remains within the project budget, with estimates verified at each stage per the Design and Construction Manual. While there are no specific MBE, WBE, PBE, or VBE goals, participation is encouraged. There is no set-aside status for this contract. Selections for the project are scheduled to be presented at the Board Meeting on March 9, 2027.

General Info

A/E sought to replace the EOC computer room fire protection system.

NAICS

N/A

Place of Performance

IL, USA

Set-Aside

NONE

Documents

1
PDF, High priority: read this firstsow
High

Read the document

Due in 20 days

Every page of every file, in your free workspace.

Read the document

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

View Full Breakdown
Due in 20 days

Everything you need to bid on this one

Open the full contract in your free workspace.

  • 1 solicitation documentRead every page
  • AI contract breakdown13 sections, Uniform Contract Format
Open the full contract

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

Posted

Contract opportunity posted

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyIllinois Emergency Management Agency
Contacts1 person available
OfficeIL
Office AddressIL
Contacts
McHenry MattProject manager

Full Description

Show more
The Emergency Operations Center (Z0101) is a 50,000 square foot, 2-story building established in 2005,
The scope of work provides for the full replacement of the current pre-action fire protection system with a new, clean agent fire protection system in the computer room. The A/E shall assess the project for eligibility under applicable utility incentive programs, energy grants, rebates, and other funding opportunities. The A/E shall identify all qualifying programs and shall prepare, coordinate, and submit all required applications, calculations, supporting documentation, and related materials necessary to obtain available incentives for the project.
The A/E is required to coordinate all telecommunications and networking requirements with the Department of Innovation & Technology (DoIT) during design and construction.
The A/E is encouraged to include independent cost estimators on their teams to verify estimates are in line with current market conditions to avoid project bids that exceed the available funding for the project. The A/E estimates should be updated and verified at each stage of the project in accordance with the Design and Construction Manual. Designers are reminded that their Professional Services Agreements make them responsible for providing a design that is within budget, and they can be held responsible for redesigning the project should the bids received exceed project funding.
If applicable, the design will need to comply with the Illinois Stretch Energy Code. There are no MBE/WBE/PBE/VBE goals applied to the A/E team, but participation is encouraged.

More opportunities from Illinois Emergency Management Agency

Same awarding agency

Get AI-powered intelligence on this solicitation and the ones like it

Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.

Miguel
Hillary
Keith Deutsch
Christine

Join 900+ contractors already using CLEATUS