66 -- Notice of Intent to award a sole source contract.

Closed
CPSC-Q-03-1303Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

N/A

NAICS

N/A

Place of Performance

10901 DARNESTOWN ROADGAITHERSBURG, MARYLAND 20878-2611

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Presolicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts2 people available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts
Peter J. NerretContract Specialist
Donna HuttonContracting Officer

Full Description

Show more
Notice of Intent to award a sole source contract for a Process Multi-Method/ Channel Analyzer to Rosemount Analytical, Inc. The Contractor shall provide a Multi-Method Channel Analyzer, model NGA 2000 MLT 4 (#Z-A-4-4-A3-B5-06-C3-A3-B-1-F-I-A-4-V-P-4-3) to be used in gas sampling. The analyzer shall be programmable, 5 channel'MLT 4.5M, capable of measuring CO, CO2, O2 and hydrocarbons in test chamber with another CO channel capable of measuring background CO. Each channel shall have between 2 and 4 ranges. Channels shall be configurable in series or parallel. System shall be capable of processing samples with up to 89% water saturation at 20 Centigrade. System shall be capable of a nominal sample flow rate of 500-1000cc/min. The system shall be rated for ambient temperature conditions between 59 to 95 C and must be capable of higher temperature than ambient temperature so as to eliminate condensation within the instrument. Sample cell will be 55 centigrade. System shall employ digital outputs for auto calibration. Analyzer shall have interchangeable sampling modules. Accuracy, drift and reproducibility shall be +/- 1% full scale per 24 hours and no more than 2% per week. Power supply shall be 120/130 VAC, 10 A, 24 VDC. Interested parties offering equal systems to the model identified above, may submit evidence of technical equality and complete system specifications to: Mr. Peter J. Nerret, Sr.,Consumer Product Safety Commission, Division of Procurement Services, Suite 517, 4330 East West Hwy., Bethesda, Maryland 20814. If interested parties propose no equal analyzers within 10 calendar days after publication of this notice, this contract will be negotiated and awarded to Rosemount Analytical, Inc.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS