Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

This Award Notice opportunity from Department Of Veterans Affairs was posted on March 25, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6632--Automated Osmolality Testing

Awarded
Federal
Solicitation #
36C24826Q0407

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334516
New
International
Purchase of Rapid Visco Analyzer (RVA)
Solicitation # 26-58222
The National Research Council of Canada (NRC) is seeking to procure a Rapid Visco Analyzer (RVA) to establish in-house viscosity and pasting profile testing capabilities. This acquisition is intended to increase analytical capacity for research involving starches, flours, grains, and other biomaterials, thereby reducing reliance on external service providers and improving the efficiency of test result delivery. The contract includes the provision of the equipment, as well as travel, installation, testing, and commissioning services. All deliverables must be received by March 31, 2027, with the RVA and associated accessories delivered within 60 calendar days of the contract award to the NRC facility in Saskatoon, SK. The award will be based on the lowest evaluated price among offers that meet all mandatory technical criteria. These requirements include specific physical dimensions (maximum 400 mm height, 310 mm width, 350 mm depth), a maximum weight of 20 kg, and a temperature range of 0 °C to 140 °C. The instrument must be capable of measuring viscosities from 20 to 40,000 cP at 80 rpm and be compatible with a refrigerated circulator. Additionally, the supplier must provide a comprehensive library of validated standard methods, including General Pasting, High-Temperature General Pasting, and Pulse Flour and Starch methods. There is no set-aside status for this procurement.
National Research Council of Canada

POSTED

1 day ago

DEADLINE

in 24 days

AI Contract Overview

Show more

The Department of Veterans Affairs, Veterans Integrated Service Network 8, through the James A. Haley Veterans Hospital in Tampa, Florida, is preparing to issue a Request for Quote (RFQ) for Automated Osmolality CPT testing equipment or equivalent. This procurement follows the North American Industry Classification System code 334516, which pertains to Analytical Laboratory Instrument Manufacturing, with a small business size standard of 1,000 employees. The solicitation, numbered 36C24826Q0407, is expected to be posted on or around March 11, 2026, with a response deadline of March 18, 2026, at 11:00 a.m. EST. Vendors interested in submitting quotes must be registered in the System for Award Management (SAM) and SDVOSBs must be certified by the Small Business Administration. This pre-solicitation notice serves only to inform potential vendors and is not a request for quotes or a commitment by the government to procure. The place of performance for the contract is Tampa, Florida, and the primary point of contact for this opportunity is Contracting Officer David Griganavicius. Interested parties are advised to monitor the Sam.gov website for the official RFQ posting and any amendments.

General Info

VA seeking quotes for Automated Osmolality CPT testing equipment; response deadline March 18, 2026.

Contract Value

$147,504.01

NAICS

334516 - Analytical Laboratory Instrument Manufacturing

Place of Performance

FL, USA

Set-Aside

service-disabled veteran-owned small business

Award Issued Date

Potential End Date

May 31, 2031

Documents

5
DOCX, High priority: read this first3 pages · contract-language-clause
High
DOCX, High priority: read this first51 pages · rfq
High
PDF, High priority: read this first20 pages · special-notice
High
DOCX, Low priorityaward
Low
DOCX, Low priority2 pages · presolicitation
Low

Read all 5 documents

Every page of every file, in your free workspace.

Read the documents

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

View Full Breakdown

This one is closed. Find the next one like it.

Open contracts like this one, right now:

  • Air Comparator Gage Manufacturing and SupplyOpen now, due in 11 days
  • Draeger CO2 Measuring Tube SupplierOpen now, due in 7 days
See open contracts like this

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

1 update
PhaseAwarded
Posted

Presolicitation

Type Changed

Presolicitation → Solicitation

Notice updated

The notice description changed.

Awarded

Contract was awarded

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 248-NETWORK Contract Office 8 (36C248)
Contacts1 person available
OfficeTAMPA, FL, 33637, USA

Full Description

Show more
Statement of Need: Automated Osmometer CPT
SCOPE: The Contractor shall provide a two (2) fully automated Osmometer System, including, delivery, installation, training, reagents, consumables for the Tampa VA Healthcare Network (TVAHCN), Department of Pathology and Laboratory Medicine Service (P&LMS) located at 13,000 Bruce B. Downs Blvd., Tampa, Florida 33612.
All work is to be performed in accordance with the guidelines established by Federal, State, and local ordinances. FDA and manufacturer's guidelines, with all terms, conditions, provisions, schedules, and specifications provided herein. The Contractor selected is responsible for system installation, maintenance coordination and supply procurement for all equipment.
GENERAL REQUIREMENTS:
The contractor is required to furnish all of the following:
All reagents and supplies necessary to operate the contractor's equipment, including calibrators and or calibration material, reagents, linearity testing material, at least 2 levels of test control material, disposables, consumables, cleaning solutions, diluent solutions, sheath fluids, and any instrument part required for operating all analyzers and equipment. ADDITIONAL NOTES: Contractor shall provide enough reagents sufficient to perform testing at each location for a minimum of 30 days. Reagent quality must be high enough to satisfy proficiency testing of the College of American Pathologists and the Joint Commission. Contractor to provide all reagents, calibrators, and controls needed along with technical assistance to perform correlation studies from a single lot at no additional cost for new test methods or changes in test menus. (i.e., Contractor is to provide all manpower and reagents/supplies to do correlation studies). Equipment must be able to Interface to the Lab Information System (Vista) / middleware (Data Innovations). All consumables and user-defined replacement parts necessary to operate the contractor's equipment, including secondary, aliquot tubes. On- and/or Off-site training for end users and key operators. Delivery and installation of equipment at no additional charge as well as return shipping costs at end of contract (removal). Contractor to perform equipment and assay installation including full validation of system hardware and software as well as assay performance studies as applicable (assay correlations to existing instrumentation, carryover, linearity, dilution validation, precision, accuracy, reference range studies, and normal range studies). Accuracy studies for each analyte. A minimum of 30 samples, spanning the reportable range, will be run by the present and the new contracted method. Contractors will analyze numbers and provide statistical data to accept the new method. Statistics will consist of at least mean, bias, slope, y-intercept, correlation coefficient, analysis, and meet current standards defined by CLSI. Linearity analysis will be performed on new contracted instrument(s) for each analyte to determine reportable range. A 5-point linearity analysis that adheres to the Beer­ Lambert Law should be performed as a minimum. Precision study utilizing normal and abnormal control material will be performed. This should consist of a within run precision study of 10 normal and 10 abnormal controls and a day-to-day precision study of normal controls and abnormal controls for 10 days (may be run twice a day) for a total of 20 values per level of control. Calibration verification will be performed using samples of known value. These can be calibrators or CAP assayed survey samples, or equivalent. Sensitivity: Sensitivity may be validated concurrently with the linearity verifications. Reference Range: Determine a reference range for each analyte following CLSI guidelines. Samples used for the reference range study shall be representative of the patient population being tested. Reference range assessment shall be performed for each lab. One of the following protocols should be used: A verification of the manufacturer's suggested reference range may be performed as long as the suggested range is based on a comparable population of test subjects. The manufacturer shall provide specific information defining how the suggested range was determined. A minimum of 20 reference individuals shall be used to verify the manufacturer's range. Any apparent outliers should be discarded and new specimens obtained to provide a statistically valid verification. If the suggested manufacturer's range is not appropriate for the patient population, a reference range shall be established. Establishing a reference shall follow CLSI guidelines. This requires a minimum of 120 reference individuals be used to establish a reference range. The reference interval should be determined using the nonparametric method. If a laboratory is currently using the proposed instrument/reagent system, the "in-use" reference range can be transferred to the "new" system if a method comparison study between the two systems proves to be acceptable. If comparison studies are not acceptable, then an alternate test shall be provided. Therapeutic range validation studies shall be performed by Contractor for applicable analytes, using CLSI guidelines. Carryover studies shall be performed, as applicable, as part of the initial evaluation of the instrument. Contractor will provide interpretation of raw data for each instrument installed and validate no carryover exists within the test platforms. All technical procedures shall be provided by Contractor on diskette in CLSI format, using software compatible with each Laboratory's computer system, for local modification to meet CAP requirements. All shipping costs for reagents, consumables, supplies and equipment (install and removal at the end of contract) including delivery to the clinical laboratory at all sites. Note: includes emergency, overnight delivery as necessary. Special handling for emergency orders of supplies: If the supplies are found to be defective and unsuitable for use with the Contractor s equipment, or the Contractor has failed to comply with the requirements for routine supply delivery, the Contractor is required to deliver the supplies within 24 hours of receipt of a verbal order for emergency delivery. If either circumstance has occurred, the Contractor shall deliver to the Government site in the most expeditious manner possible without additional cost to the Government, the necessary consumables in sufficient quantity as required to allow operation of the Contractor s equipment for one week (under normal Government test load volume). If additional requests for emergency supply delivery are required by the Government, they shall be honored by the Contractor until the arrival at the laboratory of the monthly standing order/routine supplies delivery with no shipping expenses.
EQUIPMENT SYSTEM TECHNICAL SPECIFICATIONS AND FEATURES:
The vendor must provide: One (1) Advanced Instruments OsmoPRO® MAX Automated Osmometer One (1) Advanced Instruments Osmo1® Single-Sample Micro-Osmometer Redundant equipment must use the same reagents, controls, calibrators, and consumables, and provide the same reference ranges.
General System Requirements OsmoPRO® MAX Automated Osmometer: All equipment provided must be new. Dimensions (W x D x H): 14.0 x 16.5 x 18 (+ or 2 inches in any direction). Electrical voltage: 100 to 240 VAC (50/60 Hz) Operating Conditions (must operate ranges below or better): Temperature 18°C to 35°C (64°F to 95°F); 5 to 80% relative humidity (non-condensing) Sample type: Serum, plasma, and urine Sampling must be from the primary tube, no pipetting or aliquoting required Measurement Principle: Freezing point depression Minimum Required Sample Volume: 190 L Sample Capacity: Must support continuous loading of at least 500 samples or more. Resolution: 1 mOsm/kg H2O Range: 0 to 2000 mOsm/kg H2O Display: Touchscreen with onboard video instructions Memory capacity: 1,000 results / 10,000 events (+ or 5% for each results / events) Temperature effects: Less than 1 mOsm/kg H2O per 5 °C (9 °F) ambient temperature change Accuracy specifications: Mean value ±2 mOsm/kg H2O from nominal value between 0 and 400 mOsm/kg H2O (1 SD) Mean value ± 0.5% from nominal value between 400 and 1500 mOsm/kg H2O (1 SD) Mean value ±0.75% from nominal value between 1500 to 2000 mOsm/kg H2O (1 SD) Precision (within run) specifications (must meet range for deviation/ variation below, or better): Standard deviation 2 mOsm/kg H2O between 0 and 400 mOsmo/kg H2O Coefficient of variation 0.5% mOsm/kg H2O between 400 to 1500 mOsm/kg H2O Coefficient of variation 0.75% mOsm/kg H2O between 1500 to 2000 mOsm/kg H2O Systems must be barcode driven, random access, and have a precision delivery system. Must be 100% walk-away system, monitoring during specimen analysis must be minimal. Must be capable of rules-based resulting of which the operator is notified when flags or warnings occur. The system shall come ready for Auto-verification of negative results. Must not introduce additional chemicals or other fluids to sample that would contaminate the sample which would preclude additional testing if needed. Shall have accurate capability of monitoring reagent usage, and provide reagent inventory upon request, in real time. Regent handling should include on board reagent stability greater or equal to 30 days. Shall have calibration and lot (calibrator and reagent) tracking. The systems shall deliver well established, standout performance on proficiency surveys. The vendor must offer peer group analysis program. The systems shall have minimal maintenance, <30 minutes, with walkaway capability and minimize staff hands-on and free technologists for more critical tasks. An electronic operator s manual shall be furnished with each model supplied. Temperature and Humidity Requirements (must meet temperature and humidity requirements, or better than, i.e. a wider tolerance for the operating range): Temperature: Between 59- and 86-degrees Fahrenheit (I5 - 30° Celsius) Humidity: Relative humidity between 30 and 80 percent Note: Troubleshooting should be provided for instances in which the operating environmental conditions are out of range. Electrical Characteristics 100-120 VAC for each module, 50/60 Hz, 250 watts max
General System Requirements Osmo1® Single-Sample Micro-Osmometer: All equipment provided must be new. Dimensions (W x D x H): 15 x 14 x 15 (+ or 2 inches in any direction). Electrical voltage: 100 to 240 VAC (50/60 Hz) Operating Conditions (must operate ranges below or better): Temperature 18°C to 35°C (64°F to 95°F); 5 to 80% relative humidity (non-condensing) Sample type: Serum, plasma, and urine Measurement Principle: Freezing point depression Minimum Required Sample Volume: 20 L Sample Capacity: One-step direct sampling, aspirate sample and load On-board printer Integrated barcode scanner for traceable sample identification and reduce transcription errors.
SYSTEM DATA MANAGEMENT HARDWARE / SOFTWARE
System shall interface instruments to Data Innovations or directly to the Lab Information System (LIS), Vista. Data Management with record storage, including instrument used for testing, for all patient results. Shall include all software and software licenses, interfaces, and hardware (e.g., servers, printers, printer drivers, monitors, UPS, etc.) required for complete system operations. Result, calibration and quality control reports must be available to be printed.
PREVENTATIVE MAINTENANCE:
The contractor shall provide maintenance, at their expense (travel, labor and parts), to keep the equipment in good operating condition and subject to security regulations. The government shall provide the contractor access to the equipment to perform maintenance services. The preventive maintenance shall be of a frequency that conforms to the manufacturer's operation and maintenance instructions for the supported equipment. Preventative maintenance tasks must be completed within 2 weeks of the due date, based on the date of the previously completed task.
SERVICE AND SUPPORT
Contractor shall respond with full service on-site technical support, Monday Friday, excluding federal holidays, 8am-5pm, for all equipment to keep the equipment in good operating condition and subject to security regulations. Response time within 3 days from date of call. Telephone technical support shall be available 24 hours/day, 7 days/week with follow up on all calls within one hour of initial call. Following determination that service is required, technical on-site support must be provided within 3 Days. The contractor will provide all parts and labor needed to repair the malfunction. Travel, per diem and other expenses associated with the repair will be borne by the contractor. The contractor shall furnish a comprehensive malfunction incident report to the installation upon completion of each maintenance call. The report shall include, at a minimum, the following: (a) date and time of notification (b) date and time of arrival (c) serial number type and model numbers(s) of equipment (d) time spent for repair, (e) description of malfunction and (f) proof of repair. Parts (e) and (f) shall be written verification of quality control of the sample run. During the contract period, should the repair record of any laboratory equipment reflect a downtime of 10% or more of the normal working days in one calendar month, a determination will be made by the contracting officer representative (COR) of the government to request a replacement the initial laboratory equipment with new equipment. Credit for Prolonged and/or Frequent Equipment Malfunction/Downtime: If a piece of equipment remains inoperative (unable to process patient specimens, perform patient testing, and/or report a valid test result) due to a malfunction through no fault or negligence of the government for a total of 48 hours consecutive hours or more, the contractor shall be assessed damages at the rate of 1/30 of the preceding average three month CPRR billings times the total number of days certified as downtime for each incident. The downtime shall start from the time the user makes a bona fide attempt to contact the contractor's designated representative (technical support hotline) until the equipment is returned to good operating order. Computer Patient Data Handling: No hardware, containing any VA patient information, is to be removed from either location, without the approval and removal of data by the VA Information Technology Department. Failure Mean Time Disclosure: The contractor will state the failure mean time (between failure and mean time to repair) for each piece of equipment offered. In addition, the Contractor will help establish normal ranges. The Contractor will provide emergency backup equipment. Only instruments which are FDA approved will be considered and shall be operational and interface with VA laboratory computer systems and upgrades. This shall be a "tum-key" system. Operator Procedure Manuals: Operator and Service manuals along with CLSI procedures shall be furnished for each instrument model supplied.
DELIVERY, PERFORMANCE, INSPECTION AND ACCEPTANCE:
General: The Contractor is responsible for performing all inspections and tests necessary to substantiate that the equipment, supplies and services furnished under the contract conform to contract requirements. The VA has the right to test all services ordered under the contract at all times and places throughout the term of the contract Government testing and inspection will not unduly delay any Contractor work being performed nor will it create a defect in services covered by this contract. Request for upgrades or replacement hardware/software, due to workload increase, excessive instrumentation failures will be evaluated as needed or at least annually with communication to the Contractor for modification of the contract. A high incidence of such problems with any equipment/analyzer or assay within the test menu supplied may indicate probable non-compliance with the terms of this contract and will entitle the government to its replacement with other analyzer(s) that can produce the required criteria of this contract satisfactorily. Downtime is defined as any time the equipment is not available for patient testing due to malfunction, unacceptable quality control, software system errors, or hardware failures. This includes time used for end-user troubleshooting, conversations with technical support or on-site engineer repair/support. Downtime for each incident shall start from the time the government makes a bona fine attempt to contact the contractor's designated representative at the prearranged contact point until the system or machine(s) is returned to the government in proper operating condition. Standard acceptable performance for the life of the contract is defined as a period of 30 consecutive calendar days by operating in conformation with the contractor's technical specification without prolonged downtime (>4 hours) per instance more than 3 times within 30 days or more than 10 instances of downtime (of any length of time) within 30 days. In the event the equipment or an assay does not meet the standard acceptable performance for 30 consecutive days, the government will notify the contractor of the ongoing unacceptable performance, and the performance will be monitored for an addition 90 consecutive days. If after 120 calendar days from the initial date of unacceptability, the vendor does not resolve the performance concerns to meet the governments expectations, the government, through the contracting officer, may request a replacement of the equipment / assay or terminate the order upon mutual agreement. Removal of the existing instrument by the Contractor shall be performed within 30 days following the acceptance of replacement equipment without additional charge to the government. Enhancements to the contractor's equipment shall be delivered to the government site and installed by the contractor within 60 days of their issuance or date of first commercial availability. The Contractor shall provide all upgrades to the equipment hardware and operating system software without additional charge to the government as necessary to ensure compliance with vendor and VA specifications. Returned goods: The VA is responsible for inspecting all products shipped hereunder and will give the contractor written notice of rejection within thirty (30) calendar days following receipt or installation by the contractor. Government's Responsibility: The trained user will perform routine operation maintenance and cleaning as required in the manufacturer's operation and maintenance instructions. The user shall maintain appropriate daily records to satisfy the requirements of this paragraph.
Equipment: The contractor is required to provide new state-of the art equipment. Previously used or discontinued models are not acceptable. Site Preparation: Site preparation specifications shall be furnished in writing by the contractor as a part of the equipment proposal. These specifications shall be in such detail as to ensure that the equipment to be installed shall operate efficiently and conform to the manufacturer's claimed specifications. Space Requirements, System Specifications, etc.: System specifications shall all be disclosed in the proposed space with limited adjustments. These specifications shall be in such detail as to ensure that the equipment to be installed shall operate efficiently and conform to manufacturer s claimed specifications. Crossover from current to new instrumentation shall be performed timely with no interruption in patient care laboratory services. The government shall prepare the site at its own expense and in accordance with the specifications furnished by the contractor. Any alterations or modifications in site preparation which are attributable to incomplete or erroneous specifications provided by the contractor which involve additional expense to the government, shall be made at the expense of the contractor. Acceptance will normally be consummated upon delivery and, when applicable, following installation and completion of personnel training. The VA reserves the right to request a ninety (90) day test and evaluation of all pieces of equipment prior to placing a delivery order under the contract. If the test and evaluation is not successful as determined by the CO and COR, the VA will not be required to continue with placing a delivery order under this contract, and no default or penalty will accrue. The contractor shall be responsible for installation, which consists of in-house delivery, positioning and mounting of all equipment listed on the delivery order and connections of all equipment and interconnecting wiring and cabling if applicable. Upon receipt of notice to proceed with installation, it shall be the contractor's responsibility to inform the Contracting Officer of any problems which may be anticipated in connection with installation, or which will affect optimum performance once installation is completed. If progress of the installation is interrupted through no fault of the contractor, the continuous installation referenced in the preceding paragraphs may be terminated until such time as the cause of delay has been eliminated, and then shall be resumed within 24 hours after the contractor has been notified that work may again proceed. Upon completion of installation the equipment will be turned over to the hospital for use. Final acceptance of the equipment and installation will be based upon an inspection and test to be performed within ten (10) calendar days from date of installation. If equipment passes inspection or if acceptance inspection is not conducted within ten (10) calendar days from installation, the Government shall accept installation with guaranteed date commencing ten calendar days after installation. The contractor will provide all operational upgrades to the equipment hardware and operating system software that materially affects the performance of the equipment, without additional charge to the government. These enhancements to the contractor's equipment shall be delivered to the government site and installed by the contractor within 60 days of their issuance or date of first commercial availability. Ownership of Equipment shall remain with the contractor. All equipment accessories (hardware and software) furnished by the contractor shall accompany the equipment when returned to the contractor. The contractor, upon expiration of order(s) at termination and/or replacement of equipment, will remove the equipment. The contractor will disconnect the equipment and will be responsible for all packing and shipping required to remove the equipment within ten business days. The hard drive will remain within the VA.
Reagents / Supplies / Consumables: The VA shall require the delivery of reagents for all services required under this contract. The contractor shall deliver reagents, shipping cost included, as needed (including emergency over-night delivery orders) from CALL orders within 24 hours. The contractor will assure that all supplies provided/ordered for use on their equipment will be of the quality necessary to produce a quality result. The reagent quality must be high enough to satisfy proficiency testing standards of the College of American Pathologists (CAP) and The Joint Commission. In the event that the supplies, to include consumables, are found to be defective and unsuitable for use with the contractor's equipment or the contractor has failed to comply with the requirements herein, the contractor is required to deliver the supplies within 24 hours of receipt of the verbal order for priority delivery from the government activity. This will be done at no cost to the government and in sufficient quantity as required to allow operation of the contractor's equipment for one week (under normal government test load volume). The Contractor is required to provide a continuously stocked inventory of reagents, calibrators, troubleshooting controls, required consumable supplies including all routinely replaced parts, disposables and any other materials required to properly perform tests on the equipment. Unexpected changes in methodology or technology will be at the expense of the Contractor. Alert and Notification of all technical advisory recalls and, or alerts, prior to or simultaneously with field alerts should be forwarded to Laboratory Supervisor and the Laboratory Manager. On or about the first day of each month, the contractor will ensure that each site is furnished with sufficient consumable supplies to produce a volume of tests for that month. Separate deliveries of products will be shipped to each testing site, as applicable. Failure to reserve adequate inventory will result in default. If the supplies / consumables are found to be defective and unsuitable for use with the contractor's equipment or the contractor has failed to comply with the requirements herein, the contractor is required to deliver the supplies within 24 hours of receipt of the verbal order from the government activity, if verbal order is received by 1pm EST time. This will be done at no cost to the government, in sufficient quantity as required to allow operation of the contractor's equipment for one week (under normal government test load volume). The Contractor shall reimburse each facility for any costs/supplies related to tests performed by another Contractor or sent to a referral laboratory when reagents were not available due to product issues or instrumentation failure. Items Included: The Contractor shall provide all routine and specialty items required to operate and maintain the equipment analyzer in optimal condition, such as but not limited to, standards, controls, calibrators, chemical test strips, printers, consumable equipment parts, and required replacement parts for maintenance or service. Any items excluded by the Contractor but required for operation of the system at any time, shall be delineated in their technical proposal. The cost of the any excluded items shall be disclosed in the price proposal. If additional requests for emergency supply delivery are required by the government, the contractor shall honor them until the arrival of the monthly standing order and routine supplies are delivered. All deliveries (routine and emergent) of reagents, supplies, consumables must be delivered directly to the laboratory at the expense of the contractor.
TRAINING The contractor, without additional charge to the government, shall provide training on- and/or off-site for at least two (2) key operating personnel per instrument module installed and all automation system components at the time of installation of the contractor's equipment. The contractor will also supply one (1) additional key operator training slots per year throughout the life of the contract. The contractor shall provide supplemental operating training to (2) two government personnel, without additional charge to the government, upon installation of an upgrade in equipment hardware or operating system software connected with the operation of an instrument already furnished. Contractor shall provide, install, and train users on the data management system with either on- or off-site training. Additional training will be provided for 2 additional operators throughout the life of the contract. Training of Operating Personnel: The contractor shall provide the services of a qualified technical person, at the time of equipment installation and at such time designated by Contracting Officer (CO) or Contracting Officer's Representative (COR) to on-site orientation and training to designated personnel in: operation and care of equipment; techniques and procedures recommended by manufacturer to achieve maximum dependable, efficient, and economical utilization of equipment. This training shall include actual demonstration and operation of the equipment including any adjustments or other actions which may be undertaken by operating personnel in the event of failure of equipment, provided that such adjustment or action will in no way jeopardize the Government's rights under contract guarantee clause. This training shall include at least (2) two-day on-site training sessions, all day, upon installation and acceptance of equipment and later, for refresher training.
REGULATORY REQUIREMENTS: If the product(s) included are considered medical devices by the US Food and Drug Administration, the manufacturer shall be in compliance with the Food, Drug and Cosmetic Act, as amended, and regulations promulgated there under.
TECHNICAL INDUSTRY STANDARDS: The contractor certifies that all applicable equipment offered under this contract shall conform to all common industry standards.
MANUFACTURED PRODUCTS: Materials furnished shall be of the current productions of manufacturers regularly engaged in manufacture of such items. Approval by Contracting Officer is required of deviation from products and manufacturers as shown in the schedule of items. Shelf-life of all consumables shall be at least ONE YEAR from shipping date unless FDA requires different expiration date.
REFERENCE SPECIFICATIONS AND PUBLICATIONS: Where an item is required to conform to certain requirements, conformance shall be evidenced by seal, label, stamp, or approval listing from such agency, or by a certified test report from an independent testing laboratory acceptable to the Government, that the item has been tested and conforms to requirements of referenced agency.
RECALLS: If at any time during the term of the contract, the FDA or the Contractor, or subcontractor initiates an item recall or FDA withdraws its approval to manufacture an item, the contractor will issue a notice to indicate the complete item description and identification of the recall with necessary instructions for return for credit or replacement.

More opportunities from Department Of Veterans Affairs → 248-NETWORK Contract Office 8 (36C248)

Same awarding agency

NAICS: 238160
New
Federal
Bid-Build (BB) Replace Miami VAHCS BLDG1 Roof
Solicitation # 36C24826R0132_1
The Department of Veterans Affairs, Network Contracting Office 8, is soliciting proposals for a fixed-price construction project to replace the roofing system on Building 1 at the Bruce W. Carter VA Medical Center in Miami, Florida. The scope of work involves the removal and replacement of approximately 214,637 square feet of roofing, including phased construction, demolition, installation of a new roofing system, removal and reinstallation of photovoltaic panels, and replacement of the Lightning Protection System. The project requires a period of performance of 1,095 calendar days from the Notice to Proceed, with a construction magnitude estimated between $10 million and $20 million. This procurement is a Service-Disabled Veteran-Owned Small Business (SDVOSB) tiered set-aside, meaning SDVOSB offers are evaluated first, followed by VOSB, other small businesses, and finally large businesses. Award will be based on best value to the Government, where non-price factors—including specialized experience, technical approach, schedule, past performance, and roofing warranty—are combined and weighted as significantly more important than price. Offerors must be actively registered in the System for Award Management (SAM) and, if submitting as an SDVOSB or VOSB, must be certified by the SBA. Key requirements include the provision of performance and payment bonds for 100% of the contract price, compliance with the Davis-Bacon Act, and adherence to the Buy American Act. Proposals are due by December 28, 2026, and must be submitted via email to the Contracting Officer and Contract Specialist.
Roofing Contractors

POSTED

2 days ago

DEADLINE

in about 1 month
View Details

Get AI-powered intelligence on the opportunities still open

Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.

Miguel
Hillary
Keith Deutsch
Christine

Join 900+ contractors already using CLEATUS