Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on July 25, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6640--BLOOD BANK REFRIGERATOR

Closed
36C26224Q1518Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

Place of Performance

Department of Veterans Affairs VA New Mexico (Albuquerque) Healthcare System 1501 San Pedro SE, Albuquerque, NM, 87108, USA

Set-Aside

NONE

Documents

1

RFI 36C26224Q1518 - Blood Bank Refrigerator

DOCX, Low priorityrfi
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)
Contacts1 person available
OfficeGilbert, AZ, 85297, USA
Office AddressGilbert, AZ, 85297, USA
Contacts
Kal CarabonContract Specialist

Full Description

Show more
THIS REQUEST FOR INFORMATION (RFI) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT DESCRIPTION This is NOT a solicitation announcement. This is a RFI only. The purpose of this RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 333415 (size standard of 1250 Employees). Responses to this RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this RFI, a solicitation announcement may be published. Responses to this RFI synopsis are not considered adequate responses for a solicitation announcement. The Department of Veterans Affairs (VA), VISN 22 Network Contracting Office, is seeking sources that can provide Blood Bank Refrigerator to store blood supplies that at a minimum meets the following salient characteristics with a brand name or equal product for the VA New Mexico (Albuquerque) Healthcare System: The refrigerator must have a capacity of 44 to 46 cubic feet. The refrigerators exterior dimensions in inches must fall in the following range: Width: 53 - 55 Height: 57 - 58.5 Depth: 22 - 24 The refrigerator must be capable of maintaining a set point of +4 degrees Celsius with minimal fluctuations. Temperature fluctuations shall remain between, +1 to +6 degrees Celsius. The refrigerator must have a digital temperature monitoring system (data logger) that provides 24/7 tracking/monitoring of the refrigerators temperature. The refrigerator must have a minimum of one (1) access port to allow for external temperature monitoring probe(s) to be inserted. All temperature monitoring devices must be medical grade. The refrigerator must have a touch screen display for user interface. The refrigerator must have double doors that open from the front. Users must be able to view the contents of the refrigerator without having to open the doors. The refrigerator doors should have a self-closing feature that ensures the doors close after being opened. The refrigerator doors must be lockable. The internal storage of the refrigerator must be drawers. The refrigerator must have a minimum of 14 slide out drawers. Each drawer must be liquid-tight to prevent spills from leaking out of the drawers. Drawers must be able to hold up to 728 units of blood products that will be stored in standard red blood cell (RBC) blood bags. The refrigerator must have the ability to captures spills. The spill capture system must be removal to allow for emptying and cleaning. The refrigerator must be compatible with existing electrical outlets that are 110V 120V, 60Hz, 15amps. The refrigerator must have the following plug type, NEMA 5-15. The refrigerator must have an internal backup power supply that will automatically supply power to maintain temperature monitoring. The refrigerator must be capable of providing both audible and visual notifications of power loss and when backup power is being used. The refrigerator must have both audible and visual temperature sensor alarm that alerts users when temperature fluctuations beyond +1 to +6 degrees Celsius. The refrigerator must have both audible and visual alarm that alerts users when the doors are left opened. The refrigerators internal and external surfaces must be made of bacteria-resistant materials. The refrigerator must be constructed of medical grade materials designed for blood storage. The refrigerator must have swivel locking casters wheels that allow the refrigerator to be moved. The refrigerator must have feet that allow for leveling on uneven surfaces. The refrigerator must use EPA compliant refrigerant. The refrigerator must comply with FDA requirements for blood product storage. The refrigerator must be energy star certified. Brand name Info: BRAND PRODUCT DESCRIPTION PRODUCT # QTY Helmer Scientific I.Series Double Doors Blood Bank Refrigerator iBR245-GX 1 The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. If you are interested and are capable of providing the sought-out supplies, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.)? (2) Is your company considered small under the NAICS code identified under this RFI? (3) Are you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items? (4) If you re a small business and you are an authorized distributor/reseller for the items identified above (or equivalent product/solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? (5) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number. (6) If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions available on your schedule/contract? (7) Please provide general pricing for your products/solutions for market research purposes. (8) Please submit your capabilities in regards to the salient characteristics being provided and any information pertaining to equal to items to establish capabilities for planning purposes? *** Submissions addressing Section (8) should show clear, compelling and convincing*** evidence that all equal to items" meet all required salient characteristics. Responses to this notice shall be submitted via email to kahlfanie.carabon@gov. Telephone responses shall not be accepted. Responses must be received no later than Thursday, August 1st, 2024 at 1:00 P.M. Pacific Time. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. Notice: No remanufactured or gray market items/supplies will be acceptable. Interested parties of RFI must be an authorized reseller, distributor, or dealer of the Original Equipment Manufacturer (OEM). Verification can be provided by an authorization letter or other documents from the OEM. Equipment shall be in accordance with the OEM terms and conditions.

More opportunities from Department Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)

Same awarding agency

NAICS: 562211
New
Federal
F999--Hazardous Material & Waste Disposal
Solicitation # 36C26227Q0071
The Department of Veterans Affairs, through Network Contracting Office 22, has issued a sources sought announcement under solicitation number 36C26227Q0071 to identify qualified contractors for hazardous material and waste management services. This is a market research effort and not a formal solicitation for award. The scope of work involves providing all labor, materials, equipment, and transportation for hazardous waste disposal, collection, and emergency response services. Performance will take place at the Greater Los Angeles VA Healthcare System West LA Main Campus and various Community Based Outpatient Clinics, including locations in San Gabriel Valley, Santa Barbara, Santa Maria, San Luis Obispo, Bakersfield, and the Captain Rosemary Bryant Mariner clinic. The acquisition is classified under NAICS code 562211 for Hazardous Waste Treatment and Disposal, with a size standard of 47.0 million dollars. In accordance with Public Law 109-461, the government is considering a total set-aside for Service-Disabled Veteran Owned Small Businesses, though it may opt for alternate set-asides or full and open competition based on the responses received. Interested firms must be registered in the System for Award Management and, if applicable, the SBA VetCert system. To be considered, respondents must submit a capability statement detailing their qualifications and past performance from the last five years, along with a completed price schedule for market research purposes. All submissions must be emailed to the contract specialist by November 6, 2026.
Hazardous Waste Treatment and Disposal

POSTED

1 day ago

DEADLINE

in 8 days
View Details
NAICS: 811111
New
Federal
Yuma Mobile Vet Center (MVC) Repair
Solicitation # 36C26227Q0055
The Department of Veterans Affairs, through the Southern Arizona Health Care System, is soliciting quotes for a firm-fixed-price service contract to perform non-mechanical body repairs on Mobile Vet Center 0828. The scope of work involves repairing cosmetic and potential structural damage to the driver's rear side, including the removal and replacement of damaged body panels, decals, and the body wrap. The selected contractor will be responsible for repainting repaired surfaces to match the existing finish and providing a craftsmanship warranty on all work. Performance will take place in Tucson, Arizona, with a base period of performance from December 1, 2026, to November 30, 2027. This opportunity is a total Small Business Set Aside, and the government will evaluate offerors based on their service-disabled Veteran-owned or Veteran-owned small business certification status and their intent to use such entities as subcontractors. Proposals must be submitted by November 9, 2026, at 11:00 am. A site visit is scheduled for November 3, 2026, in Tucson. To be eligible for award, offerors must provide a signed certification regarding limitations on subcontracting and represent compliance with FASCSA and telecommunications prohibitions. Payments will be processed via Electronic Funds Transfer through the System for Award Management.
General Automotive Repair

POSTED

1 day ago

DEADLINE

in 11 days
View Details
NAICS: 335910
New
Federal
6135--UPS Battery Replacement
Solicitation # 36C26227Q0064
Solicitation 36C26227Q0064 is a firm-fixed-price request for quotes issued by the Department of Veterans Affairs, NCO 22, for the one-time replacement of 60 batteries for the Main Server Uninterrupted Power Supply (UPS) at the San Diego VA Medical Center. This procurement is a total small business set-aside under NAICS code 335910, with a small business size standard of 1,250 employees. The scope of work requires a certified technician to remove and replace 60 C&D UPS12-545PLP batteries across two cabinets in Building 1, Room BB100-1. The contractor is responsible for all freight, installation, testing, removal, and recycling costs, and must ensure the work is completed during one coordinated event within 365 days after receipt of order. The award will be based on price only. Offerors must submit a completed and signed SF 1449 via email to the contracting officer by 15:00 Pacific Local Time on November 10, 2026. Required submission elements include the vendor's SAM UEI number, acknowledgement of amendments, specific manufacturer and model numbers, and a certificate of compliance regarding limitations on subcontracting. Performance requires strict adherence to safety protocols, including Lock out/Tag out procedures on the primary feed and tightening terminals to manufacturer torque specifications. The contractor must maintain all necessary licenses and insurance, and comply with Buy American and other federal regulatory clauses.
Battery Manufacturing

POSTED

1 day ago

DEADLINE

in 15 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS