Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Veterans Affairs was posted on July 30, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6640--Mirion CRC-55tW Dose Calibrator (Brand Name Only)

Awarded
36C25724Q0871Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

Solicitation number 36C25724Q0871 is a brand-name-only request for quote issued by the Department of Veterans Affairs for the procurement and delivery of a Mirion CRC-55Tw Dose Calibration System for the North Texas Veterans Health Care System in Dallas, Texas. This acquisition is set aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 339113. The system must meet specific technical requirements, including compatibility with Windows 10 OS and SQL Database, and is justified as a brand-name procurement to ensure compatibility with existing Nuclear Medicine Department equipment. The anticipated delivery date for the equipment is August 31, 2024. Offers are due by August 2, 2024, and must be submitted via email to the designated contracting officer. To be considered, vendors must provide a completed price schedule, proof of experience, a valid authorized distributor letter, and a two-year warranty. Evaluation is based on five key factors: technical acceptability, authorized distributor status, warranty conditions, delivery capabilities including supply chain contingency, and price. Required submission documents include a signed cover letter, a technical evaluation questionnaire, and updated representations and certifications in the System for Award Management.

General Info

Contract Value

$64,995

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

North Texas Veterans Health Care System (NTVHCS) 4500 S. Lancaster Rd., Dallas, TX, 75216, USA

Set-Aside

SDVOSBC

Award Issued Date

Documents

5

36C25724Q0871 - Miron CRC (55ft) Dose Calibration System

PDF, High priority: read this firstrfq
High

Attachment C - Cover Letter Template

PDF, High priority: read this firstspecifications
High

Attachment D - Vendor's Questionnaire for Technical Evaluation

PDF, High priority: read this firstspecifications
High

Solicitation 36C25724Q0871 - Mirion CRC-55tW Dose Calibrator

DOCX, High priority: read this firstrfq
High

Brand Name Justification - Mirion CRC 55tW Dose Calibrator

PDF, Low priorityjustification-and-authorization
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseAwarded
Posted

Combined Synopsis

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 257-NETWORK Contract Office 17 (36C257)
Contacts1 person available
OfficeSan Antonio, TX, 78240, USA
Office AddressSan Antonio, TX, 78240, USA
Contacts
Oneka RobertsonContract Officer

Full Description

Show more
Combined Synopsis/Solicitation Notice Page 4 of 4 Combined Synopsis/Solicitation Notice *= Required Field Combined Synopsis/Solicitation Notice Page 1 of 4 This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. Solicitation number 36C25724Q0871 is issued as a request for quote (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2024-04. This solicitation is issued as Service-Disabled Veteran-Owned Small Business (SDVOSB), with the associated NAICS code of 339113, which has a small business size standard of 1,250 Employees. The Contractor shall provide the equipment and delivery of the Mirion CRC-55Tw Dose Calibration System at the North Texas Veterans Health Care System (NTVHCS). See attached schedule for the contract line-item number(s), quantities, and Statement of Work. The anticipated delivery date for the supplies is approximately August 31, 2024. The provision at FAR 52.212-1, Instructions to Offerors-Commercial Items, applies to this acquisition. ADDENDUM to FAR 52.212-1 INSTRUCTIONS TO OFFERORS COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES The following provisions are incorporated into 52.212-1 as an addendum to this solicitation: (a) This solicitation is issued as Service-Disabled Veteran-Owned Small Business (SDVOSB). The vendor must be registered under NAICS 339113 to be eligible for award. Late quotes or documentation may be accepted if advantageous to the Government. (b) Submission of offers. Submit signed and dated offers to the office specified in this solicitation at or before the exact time specified in this solicitation. Offers may be submitted on the SF 1449, letterhead stationery, or as otherwise specified in the solicitation. As a minimum, offers must show: 1) Solicitation number. 2) The time specified in the solicitation for receipt of offers. 3) The name, address, and telephone number of the offeror. 4) Acknowledgment of Solicitation Amendments. 5) A technical description of the items being offered in sufficient detail to evaluate compliance with the requirements in the solicitation. This may include product literature, or other documents, if necessary; 6) Terms of any express warranty; 7) Price and any discounts; 8) Remit to address, if different than mailing address; 9) A completed copy of the representations and certifications at Federal Acquisition Regulation (FAR) 52.212-3 (see FAR 52.212-3(b) for those representations and certifications that the offeror shall complete electronically); 10) If the offer is not submitted on the SF 1449, include a statement specifying the extent of agreement with all terms, conditions, and provisions included in the solicitation. Offers that fail to furnish required representations or information or reject the terms and conditions of the solicitation may be excluded from consideration. (c) Period for acceptance of offers. The offeror agrees to hold the prices in its offer firm for 30 calendar days from the date specified for receipt of offers, unless another time period is specified in an addendum to the solicitation. (d) Multiple offers. Offerors are encouraged to submit multiple offers presenting alternative terms and conditions, including alternative line items (provided that the alternative line items are consistent with FAR subpart 4.10), or alternative commercial products or commercial services for satisfying the requirements of this solicitation. Each offer submitted will be evaluated separately. (e) Late submissions, modifications, revisions, and withdrawals of offers. 11) Attachment C Cover Letter (attached) filled out by the offeror. Attachment D Vendor s Questionnaire for Technical Evaluation (attached) filled out by the offeror. Quoter shall provide at least two (2) references for similar contracts in the public or private sector. All vendors interested in responding to this solicitation must, at minimum, provide the following documentation: 1. Completion of B.2 Price/Cost Schedule. 2. Completion of E.5 52.212-3 Offeror Representations and Certifications Commercial Products and Commercial Services (not required if completed on-line in SAM.) 3. FAR Provision 52.204-24 is a contractor fill-in requirement and must be completed in SAM on-line before providing an offer. 4. Proof of Experience working with CRC-55tW Dose Calibration System which must include authorized distributor letters / certificates for all equipment / deliveries sent to North Texas Veterans Health Care System (NTVHC) The following submissions are required to be able to evaluate each offer/quote IAW 52.212-2 Evaluation - Commercial Products and Commercial Services: 1) Technical Capabilities: a) Contractor shall submit evidence of the reliability, ability, experience, equipment, facilities, and personnel directly employed or supervised by them to render prompt and satisfactory delivery of Mirion 55tW Dose Calibration System: IAW SOW. 3) Delivery Commitment: a) Contractor/licensee shall submit proof of having an available and adequate supply of products to meet the requirements of the Computer Peripherals for VA North Texas and proof of contingency supply chain to prevent disruptions. b) Contractor shall submit evidence and understanding of delivery location. 4) Pricing: a) Contractor shall submit pricing for 1 each and any other pricing factors depending on the quantity in the Price Schedule, which incorporates all the requirements within the Statement of Work. Offeror must complete and return the Price Schedule (B.2 Price). b) The offeror shall add a statement stating, The offeror agrees to hold the prices in its offer firm for 30 calendar days from the date specified for receipt of offers . *Failure to submit a complete offer may result in an unacceptable determination. (End of Addendum to 52.212-1) Please be advised: (a) The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate offers: 1) Technical Acceptability 2) Authorized Distributor (Letter) 3) Warranty Conditions 4) Delivery 5) Price Factor 1: Technical Acceptibility Quotes will only be considered from those who are regularly involved in the business called for as listed in Statement of Work (SOW). 1) The Government will evaluate the ability to show evidence of the reliability, ability, experience, equipment, facilities, and personnel directly employed or supervised by them to render prompt and satisfactory delivery of Mirion 55tW Dose Calibration Systems. Factor 2: Authorized Distributor (Letter) Quotes will only be considered from those who provide an authorized distributor letter with their submission. Factor 3: Warranty Conditions Quotes will only be considered from those who provide documentation detailing the terms and conditions of any warranty. Factor 4) Delivery a) Contractor will be evaluated on proof submitted of having an available and adequate supply of products to meet the requirements of the Mirion 55tW Dose Calibration System for VA North Texas and proof of contingency supply chain to prevent disruptions. b) Contractor shall submit evidence and understanding of the delivery location. Factor 5: Price 1) Pricing: Contractor shall submit unit prices rounded to the nearest hundredth. Prices should be documented on the Price/Cost Schedule with the correct unit price and total amounts. 2) Period for acceptance of offers: The offeror agrees to hold the prices in its offer firm for 30 calendar days from the date specified for receipt of offers. Prices will be evaluated for completeness and reasonableness. Unrealistically high or low proposed costs or prices, initially or subsequently, may be grounds for eliminating an offeror from competition either on the basis that the offeror does not understand the requirement or has submitted an unrealistic offer. Additionally, unbalanced pricing poses an unacceptable risk to the Government and may be reason to reject an offer. The burden of proof for credibility of proposed costs/prices rests with the offeror. The Government reserves the right to amend the solicitation and remove any set-aside should pricing of all quotes be found unreasonable. (b) Options. The Government will evaluate offers for award purposes by adding the total price for all options to the total price for the basic requirement. The Government may determine that an offer is unacceptable if the option prices are significantly unbalanced. Evaluation of options shall not obligate the Government to exercise the option(s). (c) A written notice of award or acceptance of an offer, mailed or otherwise furnished to the successful offeror within the time for acceptance specified in the offer, shall result in a binding contract without further action by either party. Before the offer's specified expiration time, the Government may accept an offer (or part of an offer), whether or not there are negotiations after its receipt, unless a written notice of withdrawal is received before award. Offeror must complete FAR 52.204-24 must be completed in SAM on-line. Offeror must complete FAR 52.212-3 Offeror Representations and Certifications Offers are due by August 02, 2024, by 13:00 CST. Offers must submitted by email (see size limit note below) to Oneka Robertson at contact@example.gov . Due to email constraints by the VA, it is requested that emails being sent to the POC be no larger than 7MB. Multiple emails can be sent to the POC for an offer. If an offer is sent in multiple parts, it is recommended that a confirmation request be included in the final email, for the POC to acknowledge that all (parts) of the offer have been received. See attached documents: See attached document: 36C25724Q0871 - 1449. See attached document: BRAND NAME JUSTIFICATION SOLICIT SIGNED. See attached document: COVER LETTER See attached document: VENDOR S QUESTIONNAIRE

More opportunities from Department Of Veterans Affairs → 257-NETWORK Contract Office 17 (36C257)

Same awarding agency

NAICS: 541350
New
Federal
NTX Elevator Inspection
Solicitation # 36C25727Q0031-0001
The Department of Veterans Affairs Network Contracting Office 17 is soliciting elevator and dumbwaiter inspection and testing services for three facilities located in Dallas, Garland, and Bonham, Texas. This requirement is 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 541350. The scope of work includes annual Category 1 inspections for all conveyances and five-year Category 5 full-load testing for 23 conveyances in Garland and Sam Rayburn, and 47 conveyances in Dallas, including three dumbwaiters. All services must be performed in accordance with A17.1 and A17.2 elevator codes by TDLR-registered and QEI-certified inspectors. The contract will be awarded based on technical capabilities, past performance, and price. Deliverables include inspection reports and regulatory filings submitted to the Texas Department of Licensing and Regulation and the Contracting Officer's Representative. Invoices are to be submitted in arrears upon the completion and acceptance of services. Proposals must be submitted as a single combined PDF by November 9, 2026, at 3:00pm CST, with a 25-page limit for the technical proposal, excluding technical exhibits such as licenses and certifications. Key administrative requirements include compliance with FAR 52.222-42 and 52.222-43 regarding labor standards and the VAAR 852.219-75 certification.
Building Inspection Services

POSTED

about 10 hours ago

DEADLINE

in 11 days
View Details
NAICS: 238220
New
Federal
CANCELLATION - NTX Steam Trap Monitoring - CANCELLATION
Solicitation # 36C25727Q0033
The Department of Veterans Affairs has issued solicitation 36C25727Q0033 for a Firm-Fixed-Price contract to standardize and monitor the steam trap population at the Dallas VA Medical Center Campus. This total set-aside for VIP-listed Service-Disabled Veteran-Owned Small Businesses (SDVOSBs) involves the survey, tagging, and baselining of approximately 673 steam traps, followed by the 100 percent replacement of the verified population with quick-change trap-station assemblies. The contractor is required to install and maintain a continuous wireless failure monitoring system, perform semiannual preventive maintenance and dual-method testing, and execute authorized repairs under a Not-to-Exceed allowance. The scope specifically excludes the central boiler plant. The contract spans a base year from December 1, 2026, to November 30, 2027, with four subsequent one-year option periods, totaling a five-year period of performance. Award will be based on a combination of technical approach, price, and past performance, with a heavy emphasis on the contractor's ability to provide a quantified pre-project baseline report and a detailed phasing plan. Compliance with OSHA safety standards, including Lockout/Tagout and confined space requirements, as well as The Joint Commission's life safety standards and NFPA 70, is mandatory. Proposals must be submitted in two separate PDF volumes by November 4, 2026, including a redacted technical volume to ensure an unbiased evaluation.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

about 10 hours ago

DEADLINE

in 6 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS