Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on July 2, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6640--VMU Rack Washer and Bedding Dispenser

Closed
36C26026Q0808Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The Department of Veterans Affairs, through Network Contracting Office 20, is conducting market research to identify qualified vendors capable of providing an upgrade to an existing Tecniplast RW900GP rack washer and acquiring two new Tecniplast UP&DOWN Stand Alone Bedding Dispensers for the Veterinary Medical Unit at VA Puget Sound Health Care System in Seattle, WA. The requirement includes the supply of specific OEM parts for the washer upgrade, all of which must be sourced directly from Tecniplast USA, properly packaged, and shipped as a complete kit. The two new bedding dispensers must be stand-alone units with automatic lifting systems, dual augers, ultrasonic dispensing triggers, a 3.5-inch touchscreen interface, ergonomic adjustable height, and integrated safety and filtration systems. All equipment must be powered by single-phase 115V/60Hz, include two 16-foot power cables, and be delivered with full onsite setup and training provided by manufacturer-approved technicians. The contract, if issued, will be firm-fixed price. Respondents must be authorized resellers of Tecniplast and provide an official authorization letter from the OEM. Responses must include company name, address, SAM UEI, business size under NAICS code 339999 with a 550-employee size standard, point of contact details, and confirmation of any existing federal contracts such as GSA or NASA SEWP. The response must specify whether the proposed equipment is manufactured in the United States. All submissions must be sent via email to Nazanin Kreiner no later than July 17, 2026, 1 PM Mountain Time; no telephone inquiries will be accepted. Vendors are expected to notify the COTR at least two weeks prior to shipment. Delivery must be made to the specified address in Building 100, Warehouse 90D, and installation must occur no later than two weeks after delivery. The Government will not pay for responses, will not acknowledge receipt, and this notice does not constitute a solicitation or obligation to award a contract. Contractor personnel will not require access to VA systems or facilities and no background investigation is needed.

General Info

Upgrade Tecniplast washer and acquire two stand-alone bedding dispensers with full setup and training, sourced directly from OEM.

NAICS

339999 - All Other Miscellaneous Manufacturing

Place of Performance

Department of Veteran Affairs Puget Sound Health Care Systems, Seattle, WA, 98108

Set-Aside

NONE

Documents

1

Sources Sought Notice 36C26026Q0808 VMU Rack Washer and Bedding Dispenser

DOCX, Low prioritysources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)
Contacts1 person available
OfficeVANCOUVER, WA, 98661, USA
Office AddressVANCOUVER, WA, 98661, USA
Contacts
Nazanin KreinerContracting Officer

Full Description

Show more
THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method.
The intended contract is a firm-fixed price.
The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide Upgrade of Tecniplast Rack Washer and Acquisition of 2 Tecniplast Bedding Dispensers as outlined below in support of the Veterans Health Administration, VA Puget Sound Health Care System, 1660 South Columbian Way, Seattle, WA 98108. Potential candidates having the capabilities necessary to provide for this requirement at a fair and reasonable price are invited to respond to this Sources Sought Notice via e-mail to Nazanin Kreiner at contact@example.gov no later than July 17, 2026, 1PM, Mountain Time. No telephone inquiries will be accepted.
RESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION: Company name, address, SAM UEI, and business size; point of contact name, phone number, and e-mail address; whether services are presently offered on a current GSA Federal Supply Schedule contract, NASA SEWP, or any other Federal contract. NAICS Code 33999 with size standard of 550 employees, is applicable to determine business size standard. Please indicate whether proposed system is manufactured in the United States. Any questions or concerns may also be directed via email to Nazanin Kreiner at contact@example.gov. Telephone inquiries will not be accepted. Vendors must be authorized re-sellers of the OEM and provide an authorization letter from the OEM.
Salient Characteristics For Upgrade of Tecniplast Rack Washer and Acquisition of 2 Tecniplast Bedding Dispensers in the Veterinary Medical Unit
Background The Veterinary Medical Unit at VA Puget Sound has a requirement for upgrades to and replacement of equipment used to clean and to fill rodent housing cages with fresh bedding. The requested equipment has been approved and supported by VA Office of Research and Development through the LAM (Laboratory Animal Major Equipment) grant mechanism.
The Tecniplast rack washer (Tecniplast Model RW900GP, SN 901507) was installed as new equipment in 2012, and is now 14 years old. This washer is key to our facility s function, in use every day of the week to clean cages, cage lids and wire-bar tops, feeders, bottles, enrichment items/cage furniture, cage racks, buckets and food barrels, and carts. For this reason, we need to extend the functionality of the Tecniplast rack washer now in use. A curated list of parts was provided by the Tecniplast technician. The installation of these parts (upgrade) will be performed by our in-house R&D Lab Operations Manager.
Equipment that is used to fill the rodent housing cages (an older model Tecniplast Model 9BDS+, SN 321238) must be replaced. We need to acquire 2 stand-alone bedding dispensers (Tecniplast Model UP&DOWN Stand Alone Bedding Dispenser) to replace the poorly functioning existing bedding dispenser and to add a dispenser to a separate facility location where staff have been doing cage setup by hand. Onsite setup and training of bedding dispensers is performed by the vendor.
Salient Characteristics Curated Parts List for upgrade/ repair of Tecniplast rack washer (Tecniplast Model RW900GP, SN 901507) Must be OEM parts obtained from Tecniplast, USA Must be packaged per manufacturer requirement Must include shipping in total cost.
Item Description Part Number Qty 1 BUTTERFLY VALVE OMAL 494 CLAMP BS 4825 2"1/2-63,5+ DA+1 PN.ACT P-C0004760-00 5 2 BUTTERFLY VALVE OMAL 494 CLAMP BS 4825 2"1/2-63,5 + DA+1 PN.ACT_90°OP.ADJ P-C000477Q-00 3 3 BUTTERFLY VALVE OMAL 494 CLAMP BS 4825 2"1/2-63,5 + 2STAGE+1 PN.ACT P-C000478S-00 1 4 SILICONE CLAMP GASKET 2" PRIKG120003 3 5 CLAMP GASKET 4" (101) PRIKG140001 1 6 BUTTERFLY VALVE OMAL 494 CLAMP BS 4825 1"1/2-38,1 + DA+1 PN.ACT P-C0004741-00 4 7 1"1/4 CLAMP GASKET PRIKGI11402 10 8 2" CLAMP PRIKMI20003 1 9 STANDARD CYLINDER DSBC-63-160-PPV-A D.50 STROKE 160 STD ISO 15551 DBLE ACT PPNCL0630L4 2 10 PROXIMITY SENSOR SMT-8M-A-PS-24V-E-0,3-M8D PPNFM000006 2 11 PNEUMATIC VALVE SERIES Y DN20 PPNVR000026 1 12 PTFE CLAMP GASKET 3/4" PRIKG103401 4 13 CLAMP 3/4" - 1" - 1" 1/4 PRIKMI03401 1 14 STEAM TRAP KLINGER DTF + CLAMP DSTD00340100X10 1 15 GASKET FOR CLAMP CONNECTION 1/2" PRIKGI01201 2 16 1/2" CLAMP PRIKMI01201 1 17 BUTTERFLY VALVE OMAL 494 CLAMP BS 4825 3"-76,1 + DA+1 PN.ACT P-C000486P-00 1 18 2"1/2 CLAMP CONNECTION GASKET PRIKG121204 2 19 PROXIMITY SENSOR IB040BM46VB3 PCEIP000031 2 20 PRESSURE REDUCER MS4-LR-1/4-D5-AS PPNRD000004 1 21 SINGLE-EFFECT PNEUMATIC VALVE PPNELA00026 2 22 DOUBLE-EFFECT PNEUMATIC VALVE PPNELA00027 2 23 SINGLE-EFFECT PNEUMATIC VALVE 3 WAYS PPNELA00028 2 24 ELBOW QUICK CONNECTION D6 G 1/4" + OR GASKET PPNRSGB3000 5 25 QUICK CONNECTION D6 G 1/8" + OR GASKET PPNRSGB2000 5 26 QUICK CONNECTION D6 G 1/4" + OR GA SKET PPNRSDB3000 4 27 QUICK CONNECTION D6 G 1/8" PPNRSDB2000 4 28 QUICK CONNECTION D.6 M5 PPNRSDB1000 4 29 FLOW REGULATOR D6 G 1/8" + OR GASKET (UNLOAD) PPNRSGB20R1 4 30 FLOW REGULATOR D6 G 1/8" + OR GASKET (LOAD) PPNRSGB20R0 4 31 RILSAN TUBE 6X4 BLUE PTFR06040B0 5 32 RILSAN TUBE 6X4 RED PTFR06040R0 5 33 M12 PLUG QUICKON 0,34MM2 PHOENIX: SACC-M12MS-4QO-0,34 PCESP000009 4 34 PROCESS PUMP PB1011-F01-1002 W/BUILT-IN SOLENOID VALVE/EPDM CONN. MALE M8 PPDP0000029 4 35 QUICK CONNECTION SERTO D.8 - 1/8" cod. SO 21121-8-1/8 PPNRSDC2001 8
UP&DOWN - Stand Alone Bedding Dispenser (quantity = 2) Power supply requirements: Single Phase 115V / 60Hz Must include features: - Shipping, setup and training in total cost -Automatic electric driven lifting system: > Recessed position for bedding refilling operations > Raised position for bedding dispensing operations - #2 Separate bedding (or selected enrichments) processable - #2 Minimum level sensors - #2 Independent augers for accurate material dispensing - Dispensing triggered by ultrasonic sensors - #20 Different dosage volumes settable - 3.5" Colored touchscreen operator interface - Operator protection system inclusive of double filtration level (G4+F7) - Automatic adjustable working height for operator ergonomics - Light Bedding Kit inclusive of #2 stirrers with 24V motors - Up&Down Additional lifting control pad
Overall dimensions in resting position (L x W x H): 51.6" x 33.1" x 39.4" h Max height in working mode: 76.8" Bedding loading height: 36 Include 2 Power Cables (16' 5")
Specific Tasks Delivery: a. Notify COTR at least two weeks before shipment occurs for planning for delivery, installation and training b. Package and ship all equipment and components to the manufacturer specifications c. Delivery address: Veterinary Medical Unit Warehouse 90D Bldg. 100 1660 South Columbian Way Seattle, WA 98108
Installation and Training (for Bedding Dispensers): d. must be provided by Manufacturer approved technicians e. must be scheduled no later than 2 weeks after the scheduled delivery date.
Performance Monitoring The performance of the contractor will be supervised by the COR, or by a designee such as the Veterinary Medical Unit Supervisor. The COTR is responsible for certifying the inspection and acceptance of products provided.
Security Requirements This requirement is for parts and equipment only. The contractor employees shall not have access to VA sensitive or computer information and will not require routine access to VA Facilities. Background Investigation is not required.
Disclaimer and Important Notes: This Sources Sought Notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. The Government will treat any information received as proprietary and will not share such information with other companies. Any organization responding to this Sources Sought Notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this announcement. There is no solicitation available at this time.

More opportunities from Department Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)

Same awarding agency

NAICS: 334513
New
Federal
Boiler Plant O2 Sensor Replacement
Solicitation # 36C26027Q0101
The Department of Veterans Affairs, through the Network Contract Office 20, is conducting market research via a Sources Sought Notice for a firm-fixed price service contract to perform inspection, testing, maintenance, and repair of three model 6888 Rosemount flue gas analyzers. The work will be performed at the VA Southern Oregon Rehabilitation Center and Clinics in White City, Oregon. The primary scope involves replacing internal O2 analyzer components using original equipment manufacturer parts, specifically 18 inch standard cells, 18 inch heater strut assemblies, Hastelloy with Vee Deflectors for service up to 1300 degrees Fahrenheit, and new flange gaskets. The period of performance is six months, with on-site work required during core hours of 7:00 AM to 4:00 PM, Monday through Friday. This opportunity is designated as a total Small Business Set Aside under NAICS code 334513, with a size standard of no more than 750 employees. Qualified sources, including SDVOSB and VOSB entities, must provide company details, SAM.gov UEI numbers, and proof of manufacturer authorization if they are not the OEM. Contractors must employ qualified personnel, maintain general third-party liability insurance per FAR 52.228-5, and adhere to NEC, OSHA, and JCAHO standards. Deliverables include written daily reports to the Deputy Chief Facilities Management and testing documentation provided to the Contracting Officer's Representative. Interested parties are requested to provide a courtesy quote and capability statement to assist the government in evaluating price reasonableness and market availability.
Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables

POSTED

about 15 hours ago

DEADLINE

in 6 days
View Details
NAICS: 325998
New
Federal
Microbiological media purchase order for Clinical Microbiology laboratory.
Solicitation # 36C26027Q0104
The Department of Veterans Affairs Network Contracting Office 20 is seeking sources for a microbiology testing media purchase order to support the Seattle Division of the VA Puget Sound Medical Center. This requirement covers a wide range of critical supplies for identifying pathogenic organisms in veteran patients, including long shelf-life products like Oxidase and Indole, perishable selective agar, biochemical test kits, and ATCC organisms mandated by the College of American Pathologists for quality control. The contract is structured with a base year running from February 1, 2027, to January 31, 2028, followed by four subsequent one-year option periods ending January 31, 2032. Deliveries are to be made to the Microbiology Lab in Seattle, with weekly shipments typically scheduled for Tuesdays and individual requests fulfilled as available. Due to the perishable nature of many items, the vendor must provide tracking information, and the cost of next-day delivery for all perishable goods must be included in the individual item price. All temperature-liable products require immediate refrigeration upon delivery. Invoicing is processed through the Austin Automated Payment System in Texas, and the vendor must provide SDS sheets for all media upon request. This sources-sought notice specifically looks for capable sources, including qualified SDVOSB/VOSB entities, with a response deadline of November 10, 2026.
All Other Miscellaneous Chemical Product and Preparation Manufacturing

POSTED

about 15 hours ago

DEADLINE

in 14 days
View Details
NAICS: 238220
New
Federal
Z1DA--CON-NRM-668-22-106 Correct Domestic Water System
Solicitation # 36C26027R0014
Solicitation 36C26027R0014 is a negotiated request for proposals for the Department of Veterans Affairs to correct domestic water system deficiencies in Buildings 1 and 12 at the Mann-Grandstaff VA Medical Center in Spokane, Washington. The project is 100% set aside for Service-Disabled Veteran-Owned Small Businesses under NAICS 238220, with an estimated contract magnitude between $1 million and $2 million. The primary objective is to modify hot and cold potable water distribution systems to comply with VHA Directive 1061 for the prevention of scald injuries and Health Care-Associated Legionella Disease. The scope includes all labor, materials, and equipment, with a specific requirement to flush potable water dispensing fixtures twice weekly from installation until final acceptance. The period of performance is 275 calendar days from the Notice to Proceed. The government will utilize a Best Value tradeoff process for award, prioritizing technical experience and past performance over cost. Technical evaluations will favor offerors with demonstrated experience in phasing and Infection Control Risk Assessment (ICRA) within 24-hour operational emergency rooms. Proposals must be submitted in three separate volumes—Technical, Past Performance, and Price—by November 23, 2026. Awardees must provide performance and payment bonds, adhere to Davis-Bacon Act wage determinations, and comply with Buy American requirements. Additionally, the contractor must maintain strict confidentiality regarding sensitive information and provide a one-year warranty on all materials and installation.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

about 15 hours ago

DEADLINE

in about 1 month
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS