69kV Power Circuit Breaker Supply

Closed
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 335311
New
DIBBS
CABLE ASSEMBLY, SPECIAL
Solicitation # SPE4A6-27-T-048J
This solicitation, numbered SPE4A6-27-T-048J, is issued by the Defense Logistics Agency Weapons Support ASC Commodities Division for the procurement of four special purpose electrical cable assemblies (NSN 6150-01-672-5862). The contract specifies a delivery timeline of 165 days after receipt, with a required ship date of May 4, 2027, and a final delivery date of August 13, 2027. Delivery is established as FOB Origin under the First Destination Transportation program, with the final destination being the DLA Distribution DDSP New Cumberland facility in Pennsylvania. The government explicitly prohibits the use of additive manufacturing processes for the production of these assemblies. The contract mandates strict quality and security compliance, including CMMC Level 2 certification and adherence to ITAR and EAR export controls for technical data. Quality assurance requires inspection and acceptance at the origin, with manufacturer systems complying with SAE AS9003 or ISO 9001. Sampling must follow MIL-STD-1916 or ASQ H1331, with a zero non-conformance requirement for acceptance under MIL-STD-105/ASQ Z1.4. Packaging must adhere to MIL-STD-2073-1E and MIL-STD-129, with specific requirements for coiling the item and labeling hazardous or radioactive materials. Administrative processes, including invoicing and payment requests, must be managed through the Wide Area WorkFlow system.
DLA WEAPONS SUPPORT ASC COMMODITIES DIVISION

POSTED

about 3 hours ago

DEADLINE

in 8 days

AI Contract Overview

Show more

This subcontract involves the supply of five 69kV power circuit breakers for prime contractors working on City of Rocky Mount substation projects in North Carolina. The equipment must be manufactured to a maximum rating of 69kV/72.5kV, featuring 3,000 Amps of continuous current and a 40,000 Amps symmetrical interrupting rating. All units must adhere to IEEE, ASTM, ANSI, NEMA, OSHA, and NESC standards. The contract mandates that the breakers be manufactured within the United States or Mexico. The final delivery must include five fully tested circuit breakers accompanied by certified test reports. The solicitation was posted on October 7, 2026, with a response deadline of October 15, 2026.

General Info

Supply five 69kV power circuit breakers for City of Rocky Mount substation projects.

Documents

This scope was carved out of IFB 320-010926FD.

The full solicitation package (2 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

69kV Circuit Breakers for the North POD Substation

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

subcontract

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyNorth Carolina → City of Rocky Mount
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Supplies five 69kV power circuit breakers for prime contractors on City of Rocky Mount substation projects. Manufactures breakers to 69kV/72.5kV max rating, 3,000 Amps continuous current, and 40,000 Amps symmetrical interrupting rating per IEEE, ASTM, ANSI, NEMA, OSHA, and NESC standards. Requires US or Mexico manufacture. Delivers five fully tested breakers and certified test reports.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown