Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Pre-Solicitation opportunity from Department Of Defense was posted on February 2, 2006. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

70 -- WCRO Phase I Infrastructure

Closed
Reference-Number-F3LNBB6017A100-AFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

443120 - Computer and Software Stores

Place of Performance

Peterson AFB, CO 80917, CO

Set-Aside

SBA

Documents

1

20060120175032.zip

ZIP

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

3 updates
PhaseClosed
Posted

Presolicitation

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Notice updated

Response deadline changed from Jan 27, 2006 to Feb 2, 2006. The notice description changed.

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA2517 21 Cons Bldg 350
Contacts1 person available
OfficePETERSON SFB, CO, 80914-1117, USA
Office AddressPETERSON SFB, CO, 80914-1117, USA
Contacts
Carol L DitmerContracting Officer

Full Description

Show more
Ensure your information is current in CCR http://www.ccr.gov/ (Central Contractor Registration) and in ORCA https://orca.bpn.gov/ (Online Representations and Certifications Application). The list of items may indicate a brand name preference; however, other products considered of equal quality can be quoted. Please indicate the brand name being quoted. Please provide prices per item, a line item total, and a grand total. Ability to deliver in 30 days will be considered when reviewing quotes. If you have any questions, please contact contact@example.gov. 3 1/2 EMT CONDUIT 3 1/2 in, EMT, 10 ft, Steel 100 FT; 3-EMT CONDUIT 3 in, EMT 10 ft. Steel 530 FT; 2-EMT CONDUIT 2 in, EMT, 10 ft, Steel 350 FT; 1-EMT CONDUIT 1 in, EMT, 10 ft, Steel 400 FT; 8075 Arlington Industries Conduit, Connector, Straight, 3 1/2 in, EMT, Die Cast Zinc, Set-Screw, UL and CSA 20 EA; 807A Arlington Industries Conduit, Connector, Straight, 3 in, EMT, Die Cast Zinc, Set-Screw, UL and CSA 15 EA; 805A Arlington Industries Conduit, Connector, Straight, 2 in, EMT, Die Cast Zinc, Set-Screw, UL and CSA 20 EA; TC123A Thomas & Betts Equiv to 2004-8- Conduit, Connector, Straight, 1 in, EMT, Steel, Set-Screw, UL 75 EA; 8175 Arlington Industries Conduit, Coupling, EMT, 3 1/2 in, Die Cast Zinc, Set Screw, UL and CSA 20 EA; 817 Arlington Industries Equiv to 718-Conduit, Coupling, EMT, 3 in, Die Cast Zinc, 4-Set Screws 100 EA; 815 Arlington Industries Conduit, Coupling, EMT, 2 in, Die Cast Zinc, Set Screw, UL and CSA 80 EA; 812 Arlington Industries Conduit, Coupling, EMT, 1 in, Die Cast Zinc, Set Screw, UL and CSA 100 EA; 448 Arlington Industries Equiv to- 230-TB-Conduit Bushing, Insulated, 3 1/2 in, Plastic, Threaded 20 EA; 447 Arlington Industries Equiv to 229-TB-Conduit Bushing, Insulated, 3 in, Plastic, Threaded 20 EA; 445 Arlington Industries Equiv to 227-TB-Conduit Bushing, Insulated, 2 in, Plastic, Threaded, 20 EA; 442 Arlington Industries Equiv to 224-TB-Conduit Bushing, Insulated, 1 in, Plastic, Threaded 275 EA; P1120EG Unistrut Strut, Clamp, 3-1/2 in Pipe, 2-Piece 1-Bolt Clamp, Hot Rolled Steel 16 EA; P1119SS Unistrut Strut, Clamp, 3 in Pipe, 3.50 in O.D., 2-Piece 1-Bolt Clamp, Stainless Steel Type 304 80 EA; P1117EG Unistrut Strut, Clamp, 2 in Pipe, 2.375 in O.D., 2-Piece 1-Bolt Clamp, Hot Rolled Steel 50 EA; P1113EG Unistrut Strut, Clamp, 1 in Pipe, 1.315 in O.D., 2-Piece 1-Bolt Clamp, Hot Rolled Steel 100 EA; Conduit FLEXSTEEL Conduit, 1 in, Flexible, Steel, 50 ft, Coil 1000 FT; L423 Arlington Industries Equiv to XC273-Conduit, Connector, Straight, 1 in, Armored Cable, 1 in, Armored Cable, Squeeze, Zinc Die Cast 200 EA; B22SH-10FT-GRN B-LINE Equiv to A1200HS-10-GR-Strut, 1-Channel, Slotted, 10 ft, Hot Rolled Steel, Green Powder Coated, 1-5/8 W X 1-5/8 H in 200 FT; R1038 Thomas & Betts Strut, Threaded Rod, 3/8-16 in, 10 ft, Steel, 900 FT; B200D-PLTD B-Line Strut, Fitting, Washer Square, Steel, Zinc Plated, 1-5/8 X 1-5/8 in, 3/8 in Bolt Size 5/16 Inch Hole Size, No Twist Design 100 EA; N165 Metallics Hexagonal Nuts, Material Steel, Thread Size 3/8 in. 16 tpi, Finish Zinc Plated, 100 pk 4 PK; W127 Metallics Fender Washers, Bolt Size 3/8 in, Zinc Chromate, Inner Diameter 3/8 in, Steel, Outer Diameter 1 in 4 PK; 84256 Greenlee Concrete Anchors, Bolt Size 3/8 in 16 tpi, Diameter 1/2 in, Material Steel, Drop Anchors-50/pk 4 EA; LW174 Metallics Locking Washers, Bolt Size 3/8 in., Finish Zinc Chromate, Material Steel, Type Split, 100 pk 4 PK; 5Z337 WW Grainger 3" fire stopping caulk 4 EA; F-66-G24 Hoffman 6" X 24" Hoffman Gutter 6 EA; F-66-GCP Hoffman 6" end plate for gutter 12 EA; 6T10 Caddy Rod Hangers 250 EA; CAT324Z34 Caddy 2" J-Hooks w/clip 250 EA; TCH14134 Tapcon Concrete Anchor 1/4" Diameter 5/16" Slotted Hex Head 13/4 length- 100/box 3 EA; Condrive 2000 Tapcon Condrive 2000 Insulation tool 1 EA; 247816 Hilti 1/2" HDI-L Drop in Anchor- 50 / BOX 2 EA; H119D Steel City 1/2" Superstrut Square Washers 150 EA; 4TG35 Grainger 1/2" SDS masonry bit 6 EA; 4P106 Grainger 1/4 x 20 bolts 75 EA; JN163 Wesco Equiv to 785-991-75597-1/4" unistrut nuts- 100/BOX MIN. 100 EA; P1008EG Unistrut Strut, Channel Nut, 3/8-16 in, Mild Steel, Electro Galvanized, Channel Nut with Spring 100 EA; 4P471 Grainger 1/4" flat washers 50 EA; 521511234EW Thomas & Betts Equiv to- 4-SDW-EKO-Box, Electrical, 4 X 2-1/8 D in, 30.3 Cubic in, Steel, Standard Conduit Fittings 30 EA; CDOW Thomas & Betts Equiv to 52-NE-Box, Electrical, Switch, 1-Gang, 2 W X 3 H X 2-1/2 D in, Steel 100 EA; 84429 GREENLEE Toggle Bolts, Bolt Size 1/4 in, Length 4 in, Toggle Bolts and Spring Wings 50 per box 2 BX; TS12 Metallics Tapping Screws, Length 1/2 in Diameter No. 6 Slotted/Phillips Pan Head- 100/pk 3 EA; DWS4C Metallics Screws, Black Phosphate Finish, Self-Piercing Drywall Screws, No. 6 Diameter, Steel Zinc Chromate, Phillips Bugle Head, 1 5/8 in Length 50 EA; ASE8X8X6NK Hoffman Equiv to SC080806NK-8X8X6 Screw Cover Box 10 EA; ASE12X12X6NK Hoffman EQUIV TO SC121206NK-12x12x6 Screw Cover Box 5 EA; ASE16X16X6NK Hoffman Equiv to SC161608NK-16x16x8 Screw Cover Box 5 EA; ASE6X6X4NK Hoffman Equiv to SC060604NK-6x6x4 Screw Cover Box 20 EA; CP-25WBPLUS-10 3M Fire Barrier Caulk 10.1 fl. Oz tubes 10 EA; 1375255-8 AMP 5/8 X 5 yds. Yellow velcro 15 EA; 1375255-7 AMP 5/8 X 5 yds. Red velcro 10 EA; 1375255-9 AMP 5/8 X 5 yds. Green velcro 15 EA; PLT2S-M Panduit Cable Ties Blk Lg. 7" Pk 100 20 EA; 721X085 SPC fiber Loctite 7649 Anaerobic Primer 25 EA; 721X080 SPC fiber Loctite 680 Adhesive Hardener 25 EA; 49886-FCN Leviton Leviton Replacement Needles, 25/pack 10 PK; 35 RED 3M Electrical Tape (RED) 3/4" wide 25 RO 35 BLACK 3M Electrical Tape (BLACK) 3/4" wide 25 RO; 430 GREENLEE Poly Line, 6500 ft 2 EA; 024X190 Clauss PFAO-.5 .5 Micron Film-10/PK 2 EA; 024X194 Clauss PFAO-3 3 Micron Film-10/PK 2 EA; 024X192 Clauss PFAO-12 12 Micron Film-10/PK 2 EA; 820D Thomas & Betts Equiv to EZM1EXT-Electrical box mounting hardware F-straps 200 EA; smTalk Corning Multimode smallTalk fiber (850nm) ST compatible 1 EA; RepairitQuik Polymeric Systems Epoxy tube 1- +1 (555) 000-0000 5 EA; 3-1/2-EMT-ELL CONDUIT Conduit, Elbow, EMT, 3-1/2 in, 90 deg, Radius 15 in, Steel, Plain End, Offset 23-3/4 in 8 EA; 3-EMT-ELL CONDUIT Conduit, Elbow, EMT, 3 in, 90 deg, Radius 13 in, Steel, Plain End, Offset 20 in 12 EA; 2-EMT-ELL CONDUIT Conduit, Elbow, EMT, 2 in, 90 deg, Radius 9 1/2 in, Steel, Plain End, Offset 14-1/4 in 6 EA; 3-1/2-45DEG-EMT-ELL CONDUIT Conduit, Elbow, EMT, 3-1/2 in, 45 deg, Radius 15 in, Steel, Plain End, Offset 23-3/4 in 8 EA; 3-45DEG-EMT-ELL CONDUIT Conduit, Elbow, EMT, 3 in, 45 deg, Radius 13 in, Steel, Plain End, Offset 20 in 8 EA; 2-45DEG-EMT-ELL CONDUIT Conduit, Elbow, EMT, 2 in, 45 deg, Radius 9 1/2 in, Steel, Plain End, Offset 14-1/4 in 4 EA; CBJ-C COPE/B-LINE Bonding Jumper 40 EA; CF150/300 Cablofil Cable tray Electrozinc 12"W 6"D 10'L 60 EA; COT54 Cablofil Divider strip pre galvanized 2"H 10'L 100 EA; EDRN Cablofil Fast splice connector 50qty + 1 mounting tool 2 EA; FASLOCK Cablofil Fast lock splice connector 25qty 2 EA; GNDSB Cablofil Ground bolt 60 EA; CABLEXIT Cablofil Cable exit 5 EA; DROPOUT Cablofil Drop out 5 EA; HB2 Cablofil Wall termination 4 EA; COUPFIL Cablofil Bolt cutters 4 EA; FAS ROLLER Cablofil Fas Roller 1 EA; FS 41 Cablofil Strut connector 50qty 6 EA; TNP152 ALTINEX tilt n plug Jr. twins w/2 RG45 and 2 outlet plugs 8 EA; To encourage more participation, the response time is extended to 3 Feb 06, 8:00 a.m. MST.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS