Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, August 19 at 2:00 PM EDT

Register Free →

722449_Berry_UIC

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

Berry Petroleum Company, LLC is undertaking a short-term well rework operation at the Formax West GD-2 well in the Midway-Sunset Oil Field, Kern County, California, with API number 0403023129, to resume gas injection by perforating the existing slotted liner between 703 feet and 819 feet. The activity is expected to take one to two days during daylight hours and will utilize existing lease roads and infrastructure without requiring any new road modifications, well pad construction, or service line alterations. Temporary equipment such as a wireline unit, vacuum truck, fluid returns bins, and supporting vehicles will be mobilized to the site for the duration of operations, with produced water transported via vacuum truck for use in the rework. Human waste will be managed using self-contained toilets serviced weekly or as needed, with all waste disposed of at approved sewage facilities, and all garbage generated will be stored in closed-top containers and hauled to licensed disposal sites. The project has been granted categorical exemptions under the California Environmental Quality Act (CEQA) under Sections 14 CCR § 15301, 15302, and 15304, affirming that it involves maintenance and minor alterations to an existing facility with no significant environmental impact. The California Department of Conservation, Geologic Energy Management Division (CalGEM), is the regulatory authority overseeing the approval and acceptance of this work, with final compliance verification conducted at its Sacramento office. Although the operation is brief and low-impact, it remains subject to compliance with CalGEM regulations and state laws governing oil and gas operations. No contract value, pricing structure, federal acquisition regulation clauses, federal contracting identifiers such as UEI or CAGE codes, or formal procurement documents like solicitation numbers are included in the available information, and the project is documented as a CEQA exemption notice with no formal contract type or financial terms specified. Key points of contact for regulatory matters are provided through CalGEM’s general inquiry email and phone, while the contractor’s representative is listed as Ryan Nelson.

General Info

Berry Petroleum reworks Formax West GD-2 well for gas injection using existing infrastructure, compliant with CEQA exemptions.

Agency

California Conservation, Department of

NAICS

213112 - Support Activities for Oil and Gas OperationsView NAICS

Place of Performance

CA

Set-Aside

NONE

Documents

(1)

722449_Berry_UIC CEQA Notice of Exemption

PDFnotice-of-exemption

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia Conservation, Department of
Contacts2 people available
OfficeN/A
Organization / Agency
California Conservation, Department of
Office AddressN/A
Contacts
Catherine CalantasOffice Technician

Full Description

Show more
Berry proposes to rework a total of 1 existing well in the existing and heavily developed Midway-Sunset Oil Field to continue oil and gas resources development. The proposed rework will consist of perforating within the existing slotted liner from 703’ to 819’ and returning the well to gas injection. The rework will take 1-2 days to complete during daylight hours. Existing lease roads will be utilized to access the well location. Modifications to roads and location are not required for this project. Modifications to existing service lines are not required for this project. Produced water will be utilized for rework operations and hauled in via vacuum truck to location. Temporary equipment such as a wireline unit, vacuum truck, fluid returns bins and various vehicles to transport personnel, materials to mobilize and demobilize equipment will be utilized. Self-contained toilets will be used for human waste. Toilet holding tanks will be serviced weekly or as needed and the contents thereof will be disposed of at an approved sewage disposal facility. Garbage that is generated will be stored in closed top containers and disposed of at a licensed facility. The proposed project consists of the California Department of Conservation, Geologic Energy Management Division (CalGEM) approving 1 permit for Crimson to rework the well listed below, in the Midway-Sunset Oil Field. API # Well Name 0403023129 Formax West GD-2

Similar Contracts

Same NAICS industry code

NAICS: 213112
New
Federal
H266--Boiler Plant Gas Detection Testing
Solicitation # 36C25626Q1147
The contract titled H266--Boiler Plant Gas Detection Testing is issued by the Department of Veterans Affairs through the 256-NETWORK Contract Office 16 located in Ridgeland, Mississippi, with a solicitation number of 36C25626Q1147. It was posted on August 10, 2026, and requires responses to be submitted by 5:00 PM on August 21, 2026. The work falls under NAICS code 213112, which pertains to oil and gas field machinery and equipment manufacturing, indicating the technical nature of gas detection systems tied to boiler plant operations. The primary point of contact for inquiries is Contract Specialist Angela M Kennedy, reachable via email at angela.kennedy2@va.gov. The place of performance details are unspecified, suggesting the testing may occur at one or more VA facilities housing boiler plants requiring gas detection system verification. This solicitation does not specify a set-aside type, meaning it is open to all eligible contractors without preference given to small businesses or other categories. The purpose is to ensure safety and regulatory compliance through accurate and reliable gas detection testing in boiler plant environments, likely involving calibration, sensor verification, alarm functionality, and system documentation. Contractors must possess expertise in hazardous gas monitoring systems and be capable of performing field testing under operational conditions without disruption to facility functions.
256-NETWORK Contract Office 16 (36C256)

POSTED

5 days ago

DEADLINE

in 7 days
View Details