Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

836544_36800001_SoCalGas_UGS

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

California Conservation, Department of

NAICS

N/A

Place of Performance

Goleta, CA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia Conservation, Department of
Contacts2 people available
OfficeN/A
Organization / Agency
California Conservation, Department of
Office AddressN/A
Contacts
Kyle LackeyEnvironmental Scientist

Full Description

Show more
Southern California Gas Company has proposed to rework UGS well Miller 8, API #04-083-03411. The well is located in the La Goleta Gas Storage field in Santa Barbara County. The rework would punch and inject resin into the annulus to mitigate pressure buildup and inspect the integrity of the well. The work would include pulling the 3-1/2” completion tubing and associated BHA accessories, cleaning out the liner to bottom (if possible), running diagnostic logs to evaluate source(s) of annular pressure buildup in the 8-5/8” x 6-5/8” annulus, running a Punch-and-Inject tool, and injecting resin into the annulus. After resin injection, an assessment of the injection well would involve running inspection logs to evaluate the 6-5/8” production casing and pressure testing the production casing to meet the minimum pressure requirement (2140 psi). New 3- 1/2” tubing (to include a SSSV, a production packer and profile nipples) would be installed in the well. The well would be returned to service, and a noise/temp survey would be run to verify no communication from the storage zone to the production casing x tubing annulus (6-5/8” x 3-1/2”). Temporary equipment such as pumps and return bins would be needed. No permanent facilities would be constructed. No expansion of associated facilities would be required. Waste materials would be properly disposed of as nonhazardous or hazardous waste, as appropriate, at a facility licensed to accept the waste. The proposed work is expected to last between 45 and 60 days, with variance depending on the amount of fill and/or sand that the operator would need to cleanout in the wellbore, and the amount of resin injection intervals to complete as determined by log interpretations and vendor recommendations.

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS