A-E IDIQ, Small Business Set-aside, Mechanical Engineering, Electrical Engineering, and Plumbing A-E Services at various military installations in NAVFAC Southwest area of responsibility; but may be available worldwide

Closed
N62473-19-R-1226Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541330
New
SLED
Fire Alarm engineering for Lewis County
Solicitation # 2026-RFQ-040
Lewis County is soliciting qualifications under solicitation 2026-RFQ-040 for a professional engineering firm to provide comprehensive design and engineering services for fire alarm systems. The project encompasses several County-owned facilities, including the IT Building, Historic Courthouse, Health Building, and Lewis County Jail. The selected firm will be responsible for conducting on-site evaluations to determine the remaining useful life of existing systems, assessing code compliance with NFPA 72, IBC, and IFC standards, and developing bid-ready construction drawings and technical specifications. All designs must be stamped by a licensed electrical engineer familiar with Washington State fire alarm requirements and must integrate smoothly with existing infrastructure to ensure standardized maintenance and operations. Proposals are due by November 10, 2026, via the OpenGov platform and will be evaluated by a committee of at least three County employees using a points-based system. The evaluation criteria are equally weighted at 20 percent each across four categories: firm qualifications (including NICET certifications and licensed engineer availability), responsiveness and capacity to begin work within 30 days, regulatory compliance and permitting records, and the clarity and detail of blueprint designs. Applicants must provide a statement of qualifications, three public agency references from the last five years, and resumes of key personnel. The contract is administered by Matt Patana, Capital Infrastructure Specialist, based in Chehalis, Washington.
Capital Infrastructure

POSTED

about 17 hours ago

DEADLINE

in 21 days

General Info

NAICS

541330 - Engineering Services

Place of Performance

1220 Pacific Highway, SAN DIEGO, CA, 91932, USA

Set-Aside

SBA

Documents

5

N62473-19-R-1226 MEP Architect-Engineer Services

PDF, High priority: read this firstrfp
High

Amendment_01_MEP_Synopsis_N6247319R1226.pdf

PDF

Attacnment_A_AE_PPQ.doc

DOC

RFIs_19R1226_MEP.pdf

PDF

SF330-16e_FORM.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

3 updates
PhaseClosed
Posted

Combined Synopsis

Notice updated

Response deadline time changed from 10:00 AM UTC to 10:00 PM UTC on Aug 6, 2019. The notice description changed.

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Navfacsyscom Southwest
Contacts2 people available
OfficeSAN DIEGO, CA, 92132-0001, USA
Office AddressSAN DIEGO, CA, 92132-0001, USA
Contacts
Betty J. KimesContract Specialist
Easter P. ChristopherContract Specialist

Full Description

Show more
Amendment 01 - Dated July 17, 2019. The words "a new building HVAC system or" is added as follows: Criterion 2 -Specialized Experience & Technical Competence (SF-330, Part I, Section F): Submission Requirements: The first paragraph's second bullet item is revised to read as follows: - A minimum of one (1) project shall demonstrate relevant self-performed (see definition) experience with the preparation of a Request for Proposal for Design-Build for a new building HVAC system or the renovation/repair of an existing HVAC system. AMENDMENT 01 IS INCORPORATED INTO THE NOTICE LISTED BELOW. N62473-19-R-1226 INDEFINITE DELIVERY/INDEFINITE QUANTITY CONTRACT FOR MECHANICAL ENGINEERING, ELECTRICAL ENGINEERING, AND PLUMBING (MEP) ARCHITECT-ENGINEER SERVICES AT VARIOUS MILITARY INSTALLATIONS LOCATED IN THE NAVFAC SOUTHWEST (SW) AREA OF RESPONSIBILITY (AOR): CALIFORNIA, ARIZONA, NEVADA, COLORADO, NEW MEXICO, AND UTAH; BUT MAY BE AVAILABLE WORLDWIDE. Description: ALL INFORMATION NEEDED FOR INTERESTED PARTIES TO SUBMIT A STANDARD FORM SF-330, ARCHITECT ENGINEER QUALIFICATIONS, IS CONTAINED HEREIN. THERE IS NO SEPARATE REQUEST FOR PROPOSALS (RFP) PACKAGE TO DOWNLOAD. THIS IS A SMALL BUSINESS SET-ASIDE. This procurement will result in one Indefinite Delivery/Indefinite Quantity (IDIQ) contract for Mechanical Engineering, Electrical Engineering, and Plumbing Architect-Engineer (AE) services for various projects at various military installations located in the NAVFAC SW AOR: California, Arizona, Nevada, Colorado, New Mexico, Utah, but may include work worldwide. The preponderance of work is expected to be in Southern California. These services will be procured in accordance with 40 USC Chapter 11, Selection of Architects and Engineers, as implemented by FAR Subpart 36.6. The IDIQ contract will be for a base period of two (2) years and one (1), three (3) year option period., for a total of 5 years. The total fee for the contract term shall not exceed $30,000,000. The guaranteed minimum for the contract term is $5,000. Firm-fixed price task orders will be negotiated for this contract. The minimum value of individual task orders executed under this contract is $100,000 and the maximum value is $2,000,000. There will be no dollar limit per year. Multiple task orders may be awarded with similar completion schedules and overlapping delivery dates. Estimated start date is May 2020. THIS IS SMALL BUSINESS SET-ASIDE PROCUREMENT. A market research study was conducted by NAVFAC SW that included an assessment of relevant qualifications and capabilities of potentially qualified firms. This included review and analysis of responses to sources sought # N62473-19-R-MEPS. As a result of the market research analysis, a determination was made to solicit this procurement as a 100% total small business set-aside. The NAVFAC SW small business office concurs with the determination. This proposed contract is being solicited on an SMALL BUSINESS SET-ASIDE basis. The Small Business size standard classification is North American Industrial Classification System (NAICS) Code 541330 (Engineering Services). The Government seeks the most highly qualified firm to perform the required services, based on the demonstrated competence and qualifications, in accordance with the selection criteria. The Offeror/Contractor must demonstrate adequate in-house staffing capable to self-perform at least 50 percent of the cost of the contract as required by FAR Clause 52.219014 (b)(1) Limitation on Subcontracting. Primary A-E services required: Preparation of Requests for Proposals (RFP) for Design Build (DB) projects; Design-Bid-Build (DBB) construction contract packages (i.e., full plans and specifications); Mechanical/Electrical Site Investigations, Studies, Surveys, and Reports. Secondary A-E services required: Cost estimates; construction contract support services (CCSS) or post construction award services (PCAS); Fire Protection Engineering Designs, Studies, Surveys and Site Investigation (e.g. fire risk/hazard analysis, life safety code analysis, fire modeling and engineering documentation, antiterrorism, and final inspections and tests of installed Fire Protection Systems. Fire Protection surveys shall be conducted within the guidelines established by OPNAVINST 11320.23G. Support A-E services which may be required: Technical reviews of government-prepared RFP for DB projects and/or full plans and specifications for DBB projects; preparation of planning and programming support documents (such as DD1391 documents); incidental architectural, civil, structural, geotechnical, and environmental work; identification and abatement methods for existing asbestos-containing materials, lead-based paint, and other hazardous materials. Types of projects that are similar in scope include: sustainable energy documentation (e.g. Energy Master Planning, Commissioning, Life Cycle Cost, LEED/Third Party Certifications, Title 24 Energy Compliance documents, ASHRAE 90.1 compliance documents, and ASHRAE 90.1 Performance Rating Method reports); new construction, major repair/renovation of: onsite power generating systems (e.g. solar, cogeneration); control systems (e.g. microgrid, utility control systems); heating, ventilation, air conditioning and control systems (e.g. exhaust systems, direct digital control schematic and architecture); energy supply and distribution systems (e.g. above and below ground steam distribution, medical gas, high temperature/pressure water, refrigeration systems, and natural gas including earthquake shut off valves); plumbing systems; interior and exterior electrical power systems (e.g. interior building power, medium and low voltage distribution systems, primary and secondary substations, Uninterruptable Power Supply (UPS), emergency generators); communication and security systems (e.g. cable TV, electronic security systems); fire protection systems (e.g. fire sprinklers, fire alarm and detection systems, fire alarms and fire resistant building assemblies); and lighting systems for airfield, operational and training, commercial, institutional, industrial, research development, quality of life facilities, and other similar facilities. All contractors are advised that registration in System for Award Management (SAM) Database is required prior to award of a contract. Failure to register in the SAM Database may render your firm ineligible for award. For more information, check the SAM Web site: https://www.sam.gov. The awarded contract will be subject to specific provisions addressing the avoidance of organizational conflicts of interest, including NFAS 5252.209-9300, Organizational Conflicts of Interest. The prime firm for this contract will be required to perform throughout the contract term. Interviews may be scheduled with firms slated as the most highly qualified. Firms slated for interviews may be asked to clarify information contained in the SF-330 submittal. Elaborate presentations are not desired. SELECTION CRITERIA: Firms responding to this synopsis will be evaluated to determine the most highly qualified firms to perform the required services in accordance with the published selection criteria. Failure to comply with instructions, or provide complete information may affect the firm's evaluation or disqualify the firm from further consideration. Criteria 1 and 2 are considered most important and of equal importance to each other; Criteria 3, 4, and 5 are of lesser importance and listed in descending order of importance; and Criterion 6 is of lesser importance and will be used as a tiebreaker among firms considered to be technically equal. Evaluation of past performance and experience may include information provided by the firm, customer inquiries, Government databases, and publicly available sources. Failure to provide requested data, accessible points of contact, or valid phone numbers may result in a firm being considered less favorably in the evaluation. Specific selection criteria include: 1. Professional Qualifications 2. Specialized Experience & Technical Competence 3. Past Performance 4. Quality Control 5. Program Management, Capacity, and Location 6. Volume of Work Criterion 1-Professional Qualifications (SF330, Part I, Sections E & G): Firms will be evaluated on professional qualifications, competence, and experience of the proposed key personnel in providing services to accomplish the tasks required under this contract, including participation in example projects in the SF-330, Part I, Section F. Key personnel are individuals who will have major contract or project management responsibilities and/or will provide specialized expertise. All key personnel must be professionally registered/accredited (see definition) in their discipline. Specific disciplines that must be included in key personnel are: the Program Manager; Quality Control Managers; and professionally registered Electrical Engineers, Mechanical Engineers, and Fire Protection Engineer. Provide additional Project or Task Order Managers and Engineers, as applicable. Key personnel demonstrating experience with projects located at Navy and Marine Corps military installations may be considered more favorably in the evaluation. Firms that have both the Mechanical and Electrical Quality Control Managers as part of the Prime A-E firm may be considered more favorably. All key personnel must include the state where registration was issued, registration number, expiration date of registration, and geographic office location for each proposed key personnel member. Key personnel not providing mechanical, electrical, or fire protection engineering services will not be evaluated. Submission Requirements: SF-330, Part I, Section E. Provide resumes for all proposed key personnel that illustrate experience in the A-E services for the relevant project types proposed under this contract. Non-relevant information will not be considered. Resumes of personnel performing only support services (as listed in this contract) are not required and will not be considered. The designated Program Manager shall either be a professionally registered Electrical Engineer or a professionally registered Mechanical Engineer, and be an employee of the prime A-E firm. Provide one (1) designated Quality Control Manager that is a professionally registered Electrical Engineer and one (1) designated Quality Control Manager that is a professionally registered Mechanical Engineer. At least one (1) of the designated Quality Control Manager shall be an employee of the prime A-E firm. The prime A-E firm shall have a minimum of one (1) professionally registered Electrical Engineer on staff and one (1) professionally registered Mechanical Engineer on staff, in addition to the Program Manager, to perform the anticipated work of this contract. In addition, provide at least one (1) registered professional Fire Protection Engineer. See definitions at the end of this notice for professional registration and experience requirements. Resumes of key personnel shall demonstrate their depth of experience in their respective roles. Each resume shall include a maximum of five (5) specific relevant projects and should indicate: professional registration, certification, licensure and/or accreditation in appropriate disciplines; cite recent (within the past seven (7) years) and complete projects (see definition) - that exhibit specific experience in work relevant to the A-E services required under this contract; and indicate proposed role and responsibility in this contract. Identifying only the individual's job title will not provide sufficient information to determine their specific experience as it relates to services to be performed under this contract. Submit a copy of the applicable current professional certification/registration/accreditation certificate (personnel with registration in multiple states need only submit a copy from one state). Projects not meeting these requirements will not be considered. Indicate participation of key personnel in example projects in the SF-330, Part I, Section G. Criterion 2 -Specialized Experience & Technical Competence (SF-330, Part I, Section F): Firms will be evaluated on specialized experience in performance of services similar to those anticipated under this contract through evaluation of experience in: - 1. The proposed team's experience and technical competence in the primary and secondary A-E services for project types identified for this contract. - 2. Experience applying sustainability concepts through an integrated, cost effective design approach and designing in accordance with recognized sustainability rating systems such as Green Globe, LEED, etc. Firms may be considered more favorably by demonstrating the following: - 1. Offeror demonstrating a depth of relevant experience with the primary and secondary engineering services expected for this contract. - 2. Offeror demonstrating a depth of self-performed relevant experience with both mechanical and electrical projects expected for this contract. Submission requirements: Provide a maximum of ten (10) completed projects (see definitions) within the past seven (7) years immediately preceding the date of issuance of this notice that best demonstrate specialized experience of the proposed team in performing the primary and secondary A-E services for project types identified for this contract. Projects providing only PCAS experience will not be considered. Sufficient information to determine the date of completion of the project must be included in the project description or the project will not be considered. All relevant projects shall have a professional fee of $100,000 or more. If more than ten (10) projects are submitted, the Government will only evaluate the first ten (10) projects in the order submitted. Additional requirements: - A minimum of one (1) project shall demonstrate relevant experience with projects having professional fees of $500,000 or greater. - A minimum of one (1) project shall demonstrate relevant self-performed (see definition) experience with the preparation of a Request for Proposal for Design-Build for a new building HVAC system or the renovation/repair of an existing HVAC system. - A minimum of one (1) project shall demonstrate relevant self-performed (see definition) Design-Bid-Build experience (i.e. full plans and specs, not just PCAS services) of a mechanical system. - A minimum of one (1) project shall demonstrate relevant experience with the preparation of a Request for Proposal for Design-Build or with the design (i.e. full plans and specs, not just PCAS services) for each of the following: Exterior electrical power system with a minimum of 15kV (i.e., overhead and underground distribution systems, primary and secondary substations, emergency generators, etc.) Fire protection system and life safety features for a facility. Note: A single project may satisfy more than one of the above minimum requirements. All projects provided in the SF-330 must be completed by the actual office/branch/regional office/individual team member proposed to manage and perform work under this contract identified in SF-330, Part I, Section C. Projects not meeting this requirement will be excluded from consideration in the evaluation. To enable verification, firms should include the DUNS number along with each firm name in the SF-330 Part I, Section F, block 25, "Firm Name". Include a contract number or project identification number in block 21. Include the month and year of completion in block 22. Include an e-mail address and phone number for the point of contact in block 23(c). In block 24, include in the project description the type of project and its relevance to the scope of this contract, the contract period of performance, award contract value, current contract value, relevant sustainable features incorporated in the project, and a summary of the work performed that demonstrates relevance to specialized experience as outlined above. Firms with multiple offices shall indicate which office/branch performed the A-E services. For projects performed as a subcontractor or a joint venture involving different partners, specifically indicate the value of the work performed as a subcontractor or by those firms proposed for this contract, and identify the specific roles and responsibilities performed as a subcontractor or by those firms on the project rather than the work performed on the project as a whole. If the project description does not clearly delineate the work performed by the entity/entities offering/teaming on this contract, the project could be eliminated from consideration. NOTE: If the firm is a joint venture, projects performed by the joint venture should be submitted; however, if there are no projects performed by the joint venture, projects must be submitted for each joint venture partner, not to exceed the ten (10) project limitation. Firms failing to provide projects from all joint venture partners will be considered to have not met the requirements of the criterion. In cases where the submitted project was performed by a JV, but all JV partners for that project are not on the team identified in Part I, Section C, specifically describe the relevant work performed by the JV partner(s) proposed for this contract. Projects shall be submitted on the SF-330 at Part I, Section F and shall be completed projects. Projects not completed will be excluded from evaluation consideration. For submittal purposes, a task order on an IDIQ contract is considered a project, as is a stand-alone contract award. Do not submit an IDIQ contract as an example project. Instead, submit a relevant task order or stand-alone contract award that fits within the definition above. The Government will not evaluate information provided for an IDIQ contract. Examples of project work submitted that do not conform to this requirement will not be evaluated. All information for Criterion 2 should be submitted in the SF-330, Part I, Section F. The Government WILL NOT consider information submitted in addition to Part I, Section F in evaluation of Criterion 2. Criterion 3-Past Performance (SF330, Part I, Section H): Firms will be evaluated on past performance with Government agencies and private industry in terms of work quality, compliance with schedules, cost control, and stakeholder/customer satisfaction. Evaluating past performance and experience will include information provided in Past Performance Questionnaires (PPQs) or CPARS/ACASS for Criterion 2 projects and may include customer inquiries, Government databases, and other information available to the Government including contact with points of contact in other criteria. NOTE: Past performance information for projects listed under Criterion 2 may be given greater weight. Submission Requirements: SUBMIT A COMPLETED CPARS/ACASS EVALUATION FOR EACH PROJECT UNDER CRITERION 2. IF A COMPLETED CPARS/ACASS EVALUATION IS NOT AVAILABLE, the Past Performance Questionnaire (PPQ) (Attachment (A)) included in this notice is provided for the firm or its team members to submit to the client for each project included under Criterion 2. DO NOT SUBMIT A PPQ WHEN A COMPLETED CPARS/ACASS IS AVAILABLE. Submitted CPARS/ACASS and PPQ evaluations will not be counted as part of the 30-page limitation and shall be attached to the SF-330, behind the SF-330 Part II document. IF A CPARS/ACASS EVALUATION IS NOT AVAILABLE, ensure correct phone numbers and email addresses are provided for the client point of contact. Completed PPQs should be submitted with your SF-330. If the firm is unable to obtain a completed PPQ from a client for a project(s) before the response date set forth in this notice, firms should complete and submit with their responses the first page of the PPQ (Attachment (A)), which will provide contract and client information for the respective project(s). PPQ evaluations that are completed by a team member identified in Part I, Section C of the SF-330 are considered interested parties to this solicitation and will not be evaluated. Firms may submit a PPQ previously submitted under a different Notice/RFP (copies must be legible) as long as it is on the same form as posted with this Synopsis. Firms should follow up with clients/references to ensure timely submittal of questionnaires. If requested by the client, questionnaires may be submitted directly to the Government's point of contact, NAVFAC SW, Code CINAV.BK, Attn: Betty Kimes via email at betty.kimes@navy.mil, prior to the response date. Firms shall not incorporate by reference into their response PPQs or CPARS previously submitted in response to other A-E services procurements. However, this does not preclude the Government from utilizing previously submitted PPQ information in the past performance evaluation. Firms may provide any information on problems encountered and the corrective actions taken on projects submitted under Criterion 2. Firms may also address any adverse past performance issues. Information shall not exceed two double-sided pages (or four single-sided pages) in total. Awards, letters of commendation, certificates of appreciation, etc. shall not be submitted and will not be considered in the evaluation. Criterion 4-Quality Control Program (SF330, Part I, Section H): Firms will be evaluated on the strength of the quality control program proposed by the firm to ensure quality products and services under this contract, along with the means of ensuring quality services from their consultants/subcontractors. Submission Requirements: Describe the quality control program that will be utilized for all deliverables of this contract and the management approach for quality control processes and procedures. The description shall: - 1. Explain the quality control program including an example of how the plan has worked for one of the projects submitted under Criterion 2 or how the plan will work if it has not been used previously. - 2. Provide a quality control process chart showing the inter-relationship of the management and team components. - 3. Describe specific quality control processes and procedures proposed for this contract to ensure technical accuracy of and assurance of overall coordination of plans and specifications, and engineering and design services. - 4. Identify the design quality control managers and any other key personnel responsible for the quality control program and a description of their roles and responsibilities. One (1) designated Quality Control Manager shall be a professionally registered Electrical Engineer and one (1) designated Quality Control Manager shall be a professionally registered Mechanical Engineer. At least one (1) of the designated Quality Control Manager shall be an employee of the prime A-E firm - 5. Describe how the firm's quality control program extends to management of subcontractors. - 6. For offerors who are joint ventures and/or teams with offices in a variety of locations, describe how the QC effort will be implemented across the various team offices. Describe from which office the QC program will be managed/coordinated and the plan/methods to ensure effective QC and communication between offices. Criterion 5-Program Management and Capacity and Location (SF330, Part I, Section D & H): Firms will be evaluated on the firm's ability to plan for and manage work under the contract, the capacity to accomplish the work in the required time, and on the locations of their office(s) that will be performing the work under this contract and demonstrated knowledge of the primary geographic areas in which projects could be located. Submission Requirements: - 1. Provide an organizational chart for the team in the SF-330, Part I, Section D and discuss the management plan for this contract and personnel roles in the organization. Identify on the submitted organization chart the relationships and lines of authority of the proposed team members, including key subcontractors. Note: All individuals listed on the organization chart are not required to have a resume in Section E, such as administrative or lower level engineering positions. - 2. Describe the ability of the firm to manage, coordinate and work effectively with team members, both internal staff and subcontractors. Discuss the history of working relationships with team members, including joint venture partners where applicable. - 3. Describe the firm's present workload and the availability of the project team (key personnel and subcontractors) for the specified contract performance period. Describe the ability of the firm to accomplish multiple large task orders simultaneously and strategies to meet surges in unexpected workload demand. Describe the ability of the firm to provide qualified backup staffing for key personnel to ensure continuity of services. General statements of availability/capacity may be considered less favorably. - 4. Provide the location of the office(s) that will be performing the work, including main offices, branch offices, and offices of team members. Evaluation of firms will include consideration of the location of their offices and key personnel within the primary geographic area of the anticipated projects, primarily NAVFAC SW AOR. Provide a narrative describing the team's knowledge of the primary geographic areas in which projects could be located and the team's availability and ability to ensure timely response to requests for onsite support at Government installations throughout the NAVFAC SW AOR. Firms with a main office outside Southern California shall address how they would effectively communicate, collaborate, and share data with clients and subcontractors. Firms with a main office in Southern California may be considered more favorably in the evaluation. Criterion 6-Volume of Work (SF330, Part I, Section H) Firms will be evaluated in accordance with DOD Federal Acquisition Regulation Supplement (DFARS) Procedures, Guidance and Information (PGI) 236.602-1, from data extracted from the Federal Procurement Data System (FPDS). In the case of a joint venture (JV), data will be extracted for the JV and for each JV partner. Firms will be evaluated in terms of work previously awarded to the firm by DOD within the past twelve months with the objective of effecting an equitable distribution of contracts among qualified A&E firms including small, disadvantaged business firms, and firms that have not had prior DOD A&E contracts. Submission Requirements: Firms do not submit data for this factor. SF-330 SUBMISSION REQUIREMENTS: Architect-Engineer firms desiring to be considered for this contract must submit a completed SF-330 package. The SF-330 shall be typed, one sided, at least 11 point Times New Roman or larger. Part I shall not exceed thirty (30) single-sided 8.5 by 11 inch pages (the page limit does not include the Organizational Chart, certificates, PPQs, licenses, or the draft subcontracting plan as required by the Small Business Subcontracting criterion, nor does the page limit include cover sheets or dividers, provided these do not contain any substantive information submitted in response to the synopsis or intended to demonstrate the qualifications of the firm). Part I pages shall be numbered sequentially. The organizational chart in Section D may be one-page single sided 11 by 17 foldout, using 11 point font or larger (font limitations do not apply to graphics, captions or tables). The Organization Chart will not be counted against the 30-page limitation. Please include your DUNS and CAGE numbers in Block 30 of the SF-330. In accordance with the FAR 36.601-4(b) contracts for architect-engineer services may only be awarded to firms permitted by law to practice the professions of architecture or engineering. Firms must submit proof that they are permitted by law as required by FAR 36.601-4(b). If a firm is in a jurisdiction that requires AE firm registration, the firm must provide proof of registration. If a firm is in a jurisdiction that does not require AE firm registration, the firm must provide proof of eligibility to practice (e.g., a summary explaining under the laws of that jurisdiction.) This documentation is not counted as part of the 30-page limitation. Failure to submit the required proof could result in a firm's elimination from consideration. Firms who are offering as a joint venture should include with their submission a copy of the joint venture agreement. Failure to include the joint venture agreement may result in the firm's elimination from further evaluation. Architect-Engineer firms that meet the requirements described in this announcement are invited to submit one (1) original and two (2) hard copies of the SF-330 and one (1) CD (Adobe Acrobat .PDF format) to Naval Facilities Engineering Command Southwest, Code CINAV.BK, Attn: Betty Kimes 1220 Pacific Highway, San Diego, CA 92132. Responses are due no later than, 2:00P.M. Pacific Standard Time on, August 6, 2019. THIS IS NOT A REQUEST FOR PROPOSAL. Late responses will be handled in accordance with FAR 52.215-1. The point of contact is Betty Kimes, Contract Specialist, at betty.kimes@navy.mil, 619-532-4261. If an SF-254/SF-255 is submitted for this solicitation, it will not be reviewed or considered. As required above, provide verifiable evidence that your firm is permitted by law to practice the professions of architecture or engineering (e.g., state registration number). If hand-carrying or express mailing proposal, the firm is advised that the Contracting Officer is on a secured base. Anticipate delays in base access and plan accordingly. Hand-carried proposals must be delivered to the mailroom. Government personnel will not pick up proposals at the gate. It is the contractor's responsibility to ensure delivery to the location specified. An Offeror risks late receipt and rejection of their SF-330 package when delivery is delayed until the last few minutes before the deadline. Offerors intending to deliver the SF-330 package in-person are cautioned that the NAVFAC SW facility is located in downtown San Diego. It is recommended that the Offeror allow for delays driving through downtown San Diego caused by traffic (both freeway and city street), train/trolley crossings, parking at the pay lots/meters near the facility, and gaining access to a secure Government facility. No parking or offloading of SF-330s is available at the Government facility. SF-330s shall be delivered to the mailroom in Building 128 and reasonable time shall be allowed for mailroom personnel to receive and time stamp the SF-330. The stamp time is determined by the NAVFAC SW facility mailroom time stamp device only, not by any other time keeping device that the Offeror may use or own. Immediately upon proposal delivery, the Offeror shall leave the premises of the Government facility. An Offeror that does not leave the premises may be requested to leave or be escorted off the premises. Electronic (E-mail, facsimile, etc.) submissions are not authorized. It is the offeror's responsibility to check the NAVFAC electronic solicitation website FedBizOpps website, www.fbo.gov for any revisions to this announcement or other notices. Interested Vendors List is available via the FedBizOpps website, www.fbo.gov, under this solicitation number. Inquiries concerning this procurement should include solicitation number and title and be forwarded via email to betty.kimes@navy.mil. ALL REQUESTS FOR INFORMATION (RFIs) MUST BE SUBMITTED IN WRITING TO RECEIVE AN ANSWER. RFIs WILL BE ANSWERED VIA FEDBIZOPS. RFIs MUST BE SUBMITTED BY July, 30, 2019. *** END OF ANNOUNCEMENT *** DEFINITIONS OF TERMS: BRANCH OFFICE: An office of a firm located separately from a firm's other office(s) and having a separate address. COMBINED PROJECT(S): Projects with multiple starting and ending points, performed under separate task orders, delivery orders, or multiple contracts combined in a single description. ...

More opportunities from Department Of Defense → Navfacsyscom Southwest

Same awarding agency

NAICS: 238210
New
Federal
IDIQ JOC TOTAL SMALL-BUSINESS SET-ASIDE FOR ELECTRICAL AND OTHER WIRING INSTALLATION PROJECTS AT VARIOUS GOVERNMENT FACILITIES LOCATED WITHIN THE MARINE CORPS LOGISTICS BASE BARSTOW, MARINE CO
Solicitation # N6247324R2610
Solicitation N6247324R2610 is a Total Small-Business Set-Aside Indefinite Delivery Indefinite Quantity Job Order Contract (IDIQ JOC) issued by NAVFAC Southwest. The contract is for electrical and other wiring installation projects, including repair, renovation, and minor new construction, at various government facilities in California, specifically Marine Corps Logistics Base Barstow, Marine Corps Air-Ground Combat Center 29 Palms, Marine Corps Mountain Warfare Training Center Bridgeport, and Naval Air Weapons Station China Lake. The contract has a maximum value of 35 million dollars, with individual task orders ranging from 2,000 dollars to 1 million dollars. The performance period consists of a two-year base period and two three-year option periods, for a maximum total duration of eight years. The basis of award is Lowest Priced Technically Acceptable (LPTA). Proposals are evaluated on five factors: Ability to Manage Multiple Simultaneous Projects, Experience, Past Performance, Safety, and Price. All non-price factors are rated as acceptable or unacceptable, with Factor 1 serving as a threshold requirement for eligibility. Pricing is based on established coefficients and pre-determined unit prices using R.S. Means Cost Data. Offerors must submit their proposals electronically via the PIEE Solicitation Module by October 28, 2026. Key requirements include a 5,000 dollar bid bond, CMMC Level 2 (Self) status, and compliance with Davis-Bacon wage determinations and various DFARS clauses regarding Russian fossil fuel business operations and restrictions on certain magnets, tantalum, and tungsten.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

5 days ago

DEADLINE

in 8 days
View Details
NAICS: 238220
New
Federal
IDIQ, JOC FOR PLUMBING, HEATING, AIR CONDITIONING PROJECTS AT MARINE CORPS LOGISTICS BASE BARSTOW, MARINE CORPS AIR-GROUND COMBAT CENTER 29 PALMS, MARINE CORPS MOUNTAIN WARFARE TRAINING CENTER BRIDGEPORT, AND NAVAL AIR WEAPONS STATION CHINA LAKE, CA AOR
Solicitation # N6247324R2611
This is a Total Small Business Set-Aside Indefinite Delivery Indefinite Quantity (IDIQ) Job Order Contract (JOC) issued by NAVFAC Southwest for plumbing, heating, and air conditioning projects. The contract covers various government facilities within the California Area of Responsibility, specifically Marine Corps Logistics Base Barstow, Marine Corps Air-Ground Combat Center 29 Palms, Marine Corps Mountain Warfare Training Center Bridgeport, and Naval Air Weapons Station China Lake. The contract has a maximum ceiling value of 49 million dollars with a minimum government obligation of 5,000 dollars. The performance period consists of a two-year base period from December 1, 2024, through November 30, 2026, with two subsequent three-year option periods extending the potential performance through November 30, 2032. The procurement utilizes a Lowest Priced, Technically Acceptable (LPTA) award process. Non-price evaluation factors, including the bidder's ability and experience, technical approach, and safety records, are rated as either acceptable or unacceptable. Pricing is based on a coefficient model where offerors provide multipliers applied to R.S. Means Cost Data. Task orders are issued as Firm Fixed Price contracts with individual order limits ranging from a minimum of 2,000 dollars to a maximum of 2 million dollars. Key compliance requirements include adherence to the Davis-Bacon Act for prevailing wages in San Bernardino, Kern, Mono, and Inyo counties, and Cybersecurity Maturity Model Certification (CMMC) verification. Recent amendments have incorporated prohibitions regarding Russian fossil fuel business operations and restrictions on certain foreign-sourced magnets, tantalum, and tungsten. Contractors must also comply with strict safety standards, including OSHA and EM 385-1-1, and utilize the Wide Area WorkFlow (WAWF) system for electronic invoicing and payment.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

5 days ago

DEADLINE

in about 6 hours
View Details
NAICS: 236220
New
Federal
IDIQ JOC FOR GENERAL CONSTRUCTION PROJECTS AT GOVERNMENT INSTALLATIONS WITHIN NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND SOUTHWEST THE METROPOLITAN SAN DIEGO (NAVAL BASES SAN DIEGO, POINT LOMA, CORONADO AND MARINE CORPS AIR STATION (MCAS) MIRAMAR, CALIF
Solicitation # N6247325R0062
Navfacsyscom Southwest is conducting a market survey via a Sources Sought Synopsis to identify qualified small businesses for an Indefinite Delivery Indefinite Quantity Job Order Contract. The scope of work involves new general building construction, repair, and renovation projects at various government facilities in the Metropolitan San Diego area, including Naval Base San Diego, Naval Base Point Loma, Naval Base Coronado, and Marine Corps Air Station Miramar. The proposed contract features a two-year base period with a three-year option, for a maximum duration of five years. The estimated total contract value is 99 million dollars, with individual task orders expected to range between 2,000 and 2 million dollars. The government is specifically seeking sources that are Small Businesses, SBA certified 8(a), HUBZone, Women Owned, or Service-Disabled Veteran Owned. Under NAICS code 236220, the small business size standard is 45 million dollars. To be considered, interested firms must provide their UEI and CAGE code, bonding capacity, and evidence of a physical office within a 150-mile or three-hour radius of the installations. Capability is evaluated based on the submission of three to five recent prime contracts completed within the last five years, each valued at a minimum of 100,000 dollars, with at least 50 percent of the work self-performed. Additionally, firms must provide OSHA DART and TRC rates for 2023 through 2025, with detailed explanations required for DART rates above 3.0 or TRC rates above 4.5. Responses must be submitted via email to Rashonda T. Smith by October 28, 2026.
Commercial and Institutional Building Construction

POSTED

6 days ago

DEADLINE

in 8 days
View Details
NAICS: 562910
Federal
Request for Offer for RADMAC III Parcel E Remedial Action
Solicitation # N6247326RB009
Solicitation N62473-26-R-B-009 is a competitive request for offers under the RADMAC III Multiple Award Contract for the second phase of remedial action at Parcel E, Hunters Point Naval Shipyard in San Francisco, California. The project focuses on remediating non-aqueous phase liquid contamination at Installation Restoration Site 03, with a scope of work that includes shoreline excavation, confirmation sampling, in-situ stabilization, shoreline revetment, and the installation of a groundwater containment slurry wall and monitoring wells. The performance period is 60 months from the date of award, with work required to commence within 15 calendar days of the task order. The contract will be awarded based on best value using a trade-off process, evaluating three primary factors: Technical Approach, Local Hiring, and Price. The Technical Approach is weighted as twice as important as Local Hiring, and combined, these non-price factors are approximately equal in importance to the price. Offerors must possess valid radioactive materials licenses from the Nuclear Regulatory Commission and the State of California Department of Health Services. Additionally, the project requires 100 percent Payment and Performance Bonds for construction elements and adherence to both Service Contract Act and Davis-Bacon wage determinations. Proposals must be submitted electronically via the PIEE Solicitation Module, with a final submission deadline of November 3, 2026.
Remediation Services

POSTED

7 days ago

DEADLINE

in 14 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS