Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity was posted on December 19, 2016. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Above Ground Storage Tank (AST) Construction and Design

Closed
FA8201_OIL_STORAGE_TANKFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 332420
New
Federal
Brand Name Supply Buy for a Tank Liner for Paint Strip Tank PS-10
Solicitation # W51AA127QA006
Solicitation W51AA127QA006 is a brand name procurement for one custom-engineered, chemically resistant drop-in or bonded tank liner for Paint Strip Tank PS-10, located at the Tobyhanna Army Depot in Pennsylvania. The liner must be fabricated from 3/16 inch thick 304SS plate with outer dimensions of 143.625 by 50.625 by 72.375 inches and a 3.25 inch rim. This item is a critical replacement part used for stripping paint off materials in the plating shop. The delivery must be completed no later than 12 to 14 weeks after the contract award, with a specific delivery date set for February 10, 2027. The government will award the contract on an all or none basis to a responsible offeror based on price, delivery, and strict conformance to all technical specifications. Submissions must include a signed SF1449, a detailed quote, specifications and dimensions of the proposed item, and proof that the product is manufactured by PKG (CAGE 062D1). Offers are due by October 26, 2026, via email to Kaila Black. The procurement includes a 10 percent price evaluation preference for HUBZone small business concerns that do not waive the preference. Administrative requirements include electronic invoicing through Wide Area WorkFlow and compliance with MIL-STD-129 and MIL-STD-130 for marking and labeling. Item Unique Identification is required for items with a unit acquisition cost of 5,000 dollars or more. The contract incorporates various FAR and DFARS clauses, including the Buy American Act, cybersecurity standards under DFARS 252.204-7012, and prohibitions on hexavalent chromium. Shipping is FOB Destination, with transportation costs borne by the contractor.
W6QK Acc-Apg Cont Ct Tyad Ofc

POSTED

1 day ago

DEADLINE

in 6 days
NAICS: 332420
DIBBS
TANK, SEWAGE COLLECT
Solicitation # SPE8E8-27-T-0150
Solicitation SPE8E8-27-T-0150 is a fixed-price request for the procurement of one sewage collection tank, identified by NSN 4630-01-255-7819, for the Defense Logistics Agency. The item is to be delivered FOB Origin to the MSC Warehouse in Norfolk, Virginia, with an original required delivery date of March 17, 2026, and a delivery window of 20 days after the order. The procurement is managed by DLA Troop Support, Construction and Equipment, with Alexis Selby serving as the primary point of contact. The contract mandates strict adherence to quality and packaging standards, including MIL-STD-2073-1E for packaging and MIL-STD-129 for marking. It incorporates the DLA Master List of Technical and Quality Requirements and prohibits the intentional addition of mercury to hardware, except where functionally required. Compliance with the Buy American and Balance of Payments Program is required for quotes exceeding the micro-purchase threshold. Administrative requirements include electronic invoicing via the Wide Area WorkFlow system and destination inspection and acceptance per FAR 52.246-1. Offerors must submit quotes through the DIBBS portal by October 26, 2026, and are encouraged to provide quantity ranges. Additionally, the successful offeror must provide a Safety Data Sheet prior to award and certify that no covered telecommunications equipment or services from prohibited sources will be provided.
Defense Logistics Agency

POSTED

7 days ago

DEADLINE

in 6 days
NAICS: 332420
SLED
RFQ - AS NEEDED 10,000 GALLON WATER STORAGE TANK
Solicitation # 13394
The County of San Diego, Department of County Fire, is soliciting quotes under RFQ 13394 for the provision of 10,000-gallon water storage tanks on an as-needed basis. These tanks are essential for firefighting operations in remote or rural areas of San Diego where reliable water sources are unavailable. The contract is structured with an initial one-year base period and four subsequent one-year option periods. All tanks must be new, constructed from carbon steel or equivalent material, and feature specific interior and exterior coatings, with gray as the preferred color. Deliveries are to be made F.O.B. destination, primarily to Fire Station 31 in Potrero or other locations within San Diego, between 8:00 am and 4:00 pm PST on weekdays. The contractor is responsible for all offloading equipment, staff, and necessary oversized load permits. Award decisions will be based on the best value to the County, evaluating factors such as technical merit, experience, capacity, price, and availability. Additional considerations include cultural competency and sustainability impacts per Board Policy B-67. Offerors must submit a signed cover page, representations and certifications, and a narrative response not exceeding five pages. Invoicing is handled electronically via email and must reference the contract number and a specific payment schedule. Compliance with federal and state non-discrimination laws, including the ADA and Title VII of the Civil Rights Act, is mandatory. Furthermore, contractors must certify they are not debarred or ineligible via the System for Award Management (SAM), the HHS Office of Inspector General LEIE, or the California Medi-Cal Suspended and Ineligible list.
San Diego County

POSTED

11 days ago

DEADLINE

in 10 days

General Info

Agency

N/A

NAICS

332420 - Metal Tank (Heavy Gauge) Manufacturing

Place of Performance

BLDG 515 HILL AFB, HILL AFB, UT, 84056, USA

Set-Aside

SBA

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts1 person available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts

Full Description

Show more
AST Required Specifications 1. Above Ground Storage Tank (AST) Construction and Design A. AST construction shall be of sound engineered design: i. AST must be heavy duty, steel construction and compatible for storage of flammable and combustible liquids IAW UL 142, OSHA, and NFPA standards. ii. Overall design and function shall maintain a high degree of structural integrity and quality. iii. Design and construction that enables precipitation to shed off tank surfaces iv. AST Capacity/Dimensions: AST capacity shall be a minimum of 660 gallons and have overall dimensions or footprint of no greater than 11 - ft. X 11 - ft. with maximum tank height of 6 ft. for placement on existing concrete pad. v. AST shall be double walled construction with a primary steel storage tank and secondary containment tank capable of containing 110% of the contents of the primary tank. vi. Secondary containment tanks shall be engineered to support primary tank and its contents vii. Interior steel tank joints must be continuous weld on each side of joints viii. Exterior joints not required for structural integrity may be seal welded ix. AST system must have support legs capable of providing stable distribution of tanks and contents x. AST shall have lifting lugs on tank system and forklift pockets to enable AST transport by forklift B. AST shall have stepped access to fill funnel to facilitate liquid pouring: 1. Step system shall meet Occupational Safety and Health Administration (OSHA) requirements 2. AST step system and components shall be anti-slip galvanized metal grate step design capable of draining precipitation and preventing personnel slips and falls 2. Primary tank shall have the following: A. Gauge capable of measuring tank liquid levels B. Access Ports: i. A manhole with cover and seal located 180 degrees from fill funnel to facilitate oil pumping station 1. Overfill Protection- Must be equipped with an overflow/high level shutoff float system capable of being set to activate when AST is 90% capacity 2. Emergency shutoff system capable of being set to activate at 95% tank capacity a. Must have audible alarm when emergency shutoff system is activated b. Must have emergency shut-off capable of activating at 95% AST capacity c. Emergency shut-off must have capability to shut-off air pump at remote pour station to prevent additional filling of tank past 95% capacity ii. Fill funnel: 1. Must be UL accepted with a capacity of 8-12 gallons 2. Shall be 8 to 10 inches height and have a width of 14-16 inch width having an anti-slash screen to prevent splashing when pouring of liquids and to prevent small object from entering primary tank 3. Shall be designed with a hinged cover: a. With rubber gasket to prevent water infiltration and shall be capable of being secured to prevent unauthorized filling b. Capable of remaining open when during filling 4. Must be incorporated into the top of the AST so that construction and positioning of funnel in tank shall enable precipitation to be removed from AST surfaces 5. Shall be fixed in place, no more than 3 inches from tanks edge to enable filling, but capable of being removed 6. Shall have a removable suction tube: a. That is UL accepted b. With 2 inch Quick coupling c. Mounted inside the fill funnel d. That terminates within - inch from primary tank floor 7. Shall be no more than 39 inches above landing level 8. Shall be capable of being secured to prevent unauthorized disposal C. Venting: i. Primary tank shall have standard and emergency venting to relieve excess internal pressure so as to prevent tank rupture ii. Venting to be protected by approved rain cap 3. Interstitial Space/ Release Detection: A. Must be continuous monitoring B. Shall be capable of vacuum monitoring C. Must pass UL142 vacuum test procedures D. Shall have vacuum valve with gauge that indicates vacuum retention or loss. i. Vacuum valve must facilitate vacuum pump connection ii. Vacuum valve shall have emergency vent E. Must have dip stick or leak detection gauge for positive identification of primary tank leakage 4. Finishes: A. Primary tank shall be coated with an interior epoxy liner with a minimum 15 MIL thickness B. Exterior surfaces of steel tanks must be corrosion coated with epoxy primer coating a minimum of 5 MIL and top coated with industrial grade polyurethane a minimum of 7 MIL thickness 5. Labeling: A. To meet UL 142 specifications B. Serial number plate C. Manufacturer model and identification plate D. Label identifying interstitial leak detection with monitoring frequency E. Product identification ("USED OIL") with minimum 3 inch lettering F. Fire safety warnings with a minimum of 3 inch lettering to be located on all 4 sides of AST system G. Vacuum vent identification label 6. AST Compatibility with Existing Equipment: AST must be capable of being used with existing Meyer's Remote Pumping Station that will be directly connected to AST to facilitate disposal of oils from within building. 7. Shipping: A. Freight charges are to be included with purchase B. MXSG will arrange off loading and placement of tanks

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS