This Combined Synopsis/Solicitation opportunity from Department Of Health And Human Services was posted on July 9, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Acquisition of an Applied Biosystems QuantStudio 3 Real-Time PCR System

Closed
75N98026Q00714Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334516
New
Federal
RFQ: Smart-ABI+ wireless system
Solicitation # 75N95D27Q00002
The National Institutes of Health Office of Logistics and Acquisition Operations is soliciting a firm-fixed price purchase order for one Smart-ABI+ wireless system to support the National Institute on Aging Clinical Research Unit. This equipment is intended to replace obsolete ankle-brachial index testing tools to ensure standardization for peripheral arterial disease clinical research studies. The comprehensive system includes a Smart-LEDA+ software license, a portable computer with a Microsoft operating system, wireless pressure cuffs for ankles and arms, a system console with a charging station, a pulse oximeter, and various accessories such as power cords, disposable electrodes, and educational materials. A one-year partnership program including a product warranty is also required. The contract will be awarded to the responsible offeror providing the best value based on price, technical capability, past performance, and delivery schedule, with additional considerations for lifecycle cost and maintenance availability. Delivery is to be made to the National Institute on Aging at MedStar Harbor Hospital in Baltimore, Maryland. Interested offerors must be registered in the System for Award Management and submit their proposals via the SAM.gov portal by November 23, 2026. Required submission documents include unit and total pricing, delivery terms, business size certification, and completed FAR 52.212-3 representations and certifications.
National Institutes Of Health Olao

POSTED

about 23 hours ago

DEADLINE

in 9 days
NAICS: 334516
New
Federal
Request for Information - DNA Buccal Collection Kits
Solicitation # 20270753FDDU
The Federal Bureau of Investigation (FBI) is issuing a Sources Sought Notice and Request for Information (RFI) under solicitation number 20270753FDDU to identify potential sources capable of providing DNA Buccal Collection Kits. These kits are used by the Laboratory Division's Biometrics Analysis Section to process DNA databasing samples for upload to the National DNA Index System (NDIS). This is a market research effort for preliminary planning purposes and does not constitute a formal request for proposal or a commitment to award a contract. Interested small and large businesses must submit a capability statement by November 16, 2026, to Contracting Officer Bryan Lane. The required kits must meet international testing laboratory standards and ISO 9000 accreditation. Each kit must include a color-printed FD-936 form on 100# Tag Stock paper, nitrile gloves, a pre-inked fingerprint pad, ink-removal wipes, and a drying envelope with a desiccant packet. A critical requirement is the use of matching 8-character alphanumeric barcodes (format code 128 or 93) across the FD-936 form, the collection device, and the outer kit envelope. The outer envelope must be a non-white, tamper-evident, self-adhesive poly or Tyvek material with a tamper tape closure. Additionally, vendors must demonstrate the capacity to maintain a minimum inventory of 100,000 kits for immediate shipment.
Division 0700

POSTED

about 23 hours ago

DEADLINE

in 12 days
NAICS: 334516
New
Federal
Upgrade a Microscope for Fluorescence and Reflected-Light Imaging
Solicitation # 494472
UT-Battelle, LLC, the management and operating contractor for Oak Ridge National Laboratory (ORNL), is soliciting proposals to upgrade a microscope for fluorescence and reflected-light imaging. This procurement, identified by solicitation number 494472, is for products intended for use within a DOE nuclear facility. The award will be granted to the lowest priced, technically acceptable proposal based on a firm fixed price quote. Offerors must provide a proposed delivery schedule and ensure the system arrives at the company site in undamaged, working condition, with shipping notifications provided two weeks in advance. Key deliverables include the supplies specified in the Bill of Materials, written documentation verifying catalogue specifications, and a signed functional test report verifying the operability of installed systems. The contract is governed by a comprehensive set of FAR and DOE clauses, including requirements for the Buy American Act, cybersecurity compliance under DOE O 205.1D, and strict personnel security and access programs. Performance is subject to DOE site safety and health programs, including workplace substance abuse protocols. Proposals must be submitted via email to the Procurement Officer by November 20, 2026, and must include an Exceptions/Non-Compliance section; otherwise, the offeror is deemed to have accepted all terms and conditions unequivocally. This is not a small business set-aside, though offerors must provide representations and certifications regarding their business size and socioeconomic status.
Ornl Ut-Battelle Llc-Doe Contractor

POSTED

about 23 hours ago

DEADLINE

in 6 days
NAICS: 334516
New
Federal
ARBITRARY WAVEFORM GENERATOR
Solicitation # N0016427Q0014
The Naval Surface Warfare Center (NSWC) Crane has issued solicitation N0016427Q0014 for a firm fixed price, commercial, sole source procurement of six custom Arbitrary Waveform Generators (Manufacturer Part Number: 670C-4C-256M-HV4-GPIB). The equipment must feature 256 Ms memory, a high voltage output of 12Vpp on 50 phm, and a GPIB/USBTMC interface option. The government intends to negotiate exclusively with BNC Corp, as they are identified as the only responsible source capable of meeting the strict physical, technical, and operational readiness requirements necessary to avoid mission delays and financial burden. The contract includes two option years, with delivery schedules for all line items set at six weeks from the date of award or option exercise. The procurement is governed by NAICS 334516 and requires strict adherence to item identification and marking standards, including MIL-STD-130 and MIL-STD-129, using two-dimensional data matrix symbology. All deliveries are FOB Contractor Destination to NSWC Crane in Indiana. The contract incorporates critical cybersecurity requirements, specifically NIST SP 800-171 and FAR clause 252.204-7012 for safeguarding covered defense information. Invoicing must be processed electronically through the Wide Area Workflow (WAWF) system. The closing date for offers is November 25, 2026, at 2:00 PM Eastern Time.
Nswc Crane

POSTED

about 23 hours ago

DEADLINE

in 11 days
NAICS: 334516
New
Federal
Computed Tomography (CT) Scanner System
Solicitation # SP4706-27-R-XXXX
The Defense Logistics Agency (DLA) has issued a Sources Sought Notice to conduct market research for a brand-new, non-refurbished Industrial Computed Tomography (CT) Scanner System. This notice is intended for information and planning purposes to identify qualified sources, with a specific focus on small businesses, including HUBZone, 8(a), Service-Disabled Veteran-Owned, and Women-Owned Small Businesses. The procurement is categorized under NAICS code 334516 and is designated as a Small Business Set Aside. The required system must be brand-new and capable of operating on standard office power (110V, 20A). It must adhere to strict security standards, being either air-gapped or utilizing a government-secure cloud, and must comply with DoD-approved standards such as NIST SP 800-171 or CMMC. The vendor is expected to provide a complete operational handoff, which includes onsite installation, precision calibration, and comprehensive software training for up to five government employees, along with a minimum one-year manufacturer warranty and technical support. Interested respondents must submit a capability statement of five pages or less by November 30, 2026. This statement should include the company's UEI, CAGE code, and SAM.gov registration status, as well as a determination of whether the system is a Commercial-Off-The-Shelf (COTS) item or requires modification. Additionally, vendors must provide estimated lead times and up to three examples of similar systems delivered and supported within the last three years.
DCSO-COLUMBUS-DIVISION-2

POSTED

about 23 hours ago

DEADLINE

in 17 days
NAICS: 334516
New
Federal
Q301--NEW | Automated Blood Bank Solid Phase Analyzer and Associated Reagents/Consumables
Solicitation # 36C25927Q0058
The Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 19 is conducting market research through a Sources Sought Notice to identify potential providers for an instrument rental reagent agreement. The requirement is for an Automated Blood Bank Solid Phase Analyzer and associated reagents and consumables to support the Rocky Mountain Regional VA Medical Center. The proposed period of performance is from April 1, 2027, through March 31, 2032. The system must be new, in current production, and FDA approved for in vitro diagnostic methods, maintaining a monthly up-time of 95 percent. Key technical requirements include the ability to perform ABO/Rh testing, antibody screening, antibody identification, antigen phenotyping, Direct Antiglobulin Tests, and crossmatching. The system must achieve a Type and Screen turnaround time of 26 minutes or less and include an automated cell washer and centrifuge. Reagents must be compatible with manual tube testing for backup purposes, or a second analyzer must be provided. The contractor is responsible for providing and maintaining an uninterruptable power supply and ensuring all hardware and software upgrades are installed within 60 days of commercial release. Interested parties must submit a capabilities statement and a completed market research questionnaire by November 25, 2026, at 1630 CST.
Network Contract Office 19 (36C259)

POSTED

about 23 hours ago

DEADLINE

in 11 days

AI Contract Overview

Show more

The National Institutes of Health, through the National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS), is seeking to acquire a single Applied Biosystems QuantStudio 3 Real-Time PCR System to replace aging StepOnePlus instruments and ensure uninterrupted research operations. This system is essential for performing nucleic acid quantification and analysis across a broad range of applications including gene expression, pathogen detection, and validation of experimental results. The instrument must match the StepOnePlus in workflow compatibility while offering enhanced capabilities such as touchscreen operation, standalone functionality, and support for both Mac and PC platforms. It must feature a 96-well 0.1 mL block with VeriFlex technology enabling up to a 10°C temperature gradient across separated zones, support reaction volumes of 10–30 μL, and execute fast PCR protocols under 30 minutes. The system must be factory-calibrated for key dyes, include a heated lid, and operate on standard 120–240 V power without modification. It must come with an onboard computer with 10 GB storage, support for USB, network, and Connect platform data transfers, and allow local user accounts with PIN access and guest mode functionality. The instrument must integrate seamlessly into the broader QuantStudio ecosystem, including cloud connectivity via the Connect platform for remote monitoring, data uploads, and batch analysis of up to 500 experiments. Software must support absolute and relative quantification, SNP genotyping, high-resolution melt analysis, and allow protocol conversion from StepOnePlus systems. It must include preoptimized templates, statistical tools like box-whisker and heat maps, and the ability to import standard curves from one plate to another. Data can be exported to Excel and saved as image files, with command-line functions for batch processing. The system must support more than 61,000 pre-designed TaqMan assays for human, mouse, and rat gene expression, and include an API for custom programming. The contractor must deliver and install the system within 30 days of award and accept trade-in of the existing StepOnePlus unit with serial number 272008444. The device must meet ISO 13485 and ISO 9001 manufacturing standards and hold regulatory certifications including UL, CE, and WEEE. All features are designed to ensure data consistency, operational efficiency, and long-term technical support.

General Info

NIAMS seeks QuantStudio 3 Real-Time PCR system to replace aging StepOnePlus, ensuring seamless workflow, fast PCR, cloud connectivity, and full compatibility.

NAICS

334516 - Analytical Laboratory Instrument Manufacturing

Place of Performance

Bethesda, MD, 20892, USA

Set-Aside

NONE

Documents

1
DOCX, High priority: read this firstsow
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

View Full Breakdown

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Health And Human Services → National Institutes Of Health Olao
Contacts1 person available
OfficeBETHESDA, MD, 20892, USA

Full Description

Show more

Requirements:


To ensure continuity of research, NIAMS proposes the acquisition of an Applied Biosystems QuantStudio 3 Real-Time PCR System. qPCR is a core technology used for nucleic acid amplification, quantification, and analysis and supports a wide range of research applications, including gene expression studies, pathogen detection, transcript quantification, and validation of experimental results. The QuantStudio 3 is the closest replacement to the current StepOnePlus systems, allowing researchers to maintain established workflows and consistency in experimental design and data interpretation. The QuantStudio 3 offers several operational advantages, including user-friendly software, compatibility with both Mac and PC platforms, touchscreen operation, and the ability to function as a standalone instrument or in conjunction with a computer. Its thermal block design is similar to the existing systems, minimizing the learning curve for users and supporting a broad range of genomic applications. In addition, the manufacturer offers trade-in credit for the current instruments, reducing the overall acquisition cost while providing access to a fully supported platform with available parts and technical support. Acquiring the QuantStudio 3 at this time will help prevent interruptions to research activities, maintain reliable and consistent data generation, and ensure that NIAMS laboratories have access to a supported and dependable qPCR platform.


4.1 PRODUCT FEATURES/SALIENT CHARACTERISTICS The contractor shall provide one Applied Biosystems QuantStudio 3 Real-Time PCR System or an equal system that meets all the following minimum requirements. 4.1.1. System Features/Benefits The system shall: • Utilize a platform providing 1 TB or storage space for data sharing at user discretion • be used with online scientific apps • come with desktop-based software, allowing single-plate run setup and analysis.


4.1.2. Technical specifications – Instrument The instrument shall: • have a 96 well 0.1 ml plate block format and the option to run fast protocols <30 minutes • not require a field service engineer for set up by end user. Set up should be easy for end user – directly out of the box. • not require a computer for installation • use an RNase P verification plate to verify performance • not require dye calibration upon installation • have dimensions fo 27 x 50 x 40 cm and be designed to maximize horizonal and vertical bench space • be capable of analyzing 96 samples simultaneously in various formats incluing both 96-well plates, 8-tube strips and individual tubes • the 96-well block should be made of at least 3 separated Peltier elements – VeriFlex Blocks. The maximum temperature difference programmable across the block should be 10 degrees C. 5 degrees C should be the maximum difference in temperature allowed between adjacent blocks. • Support reaction volumes of 10-30 uL on 0.1mL the 96-well block • Be factory calibrated with FAM, SYBR Green 1, VIC, NED, ABY, JUN, TAMRA, and ROX dyes • Have melt or dissociation curves that take place in steps with deltaT varying between 0.015 degrees C and 3.66 degrees C • Have a maximum block ramp rate of 9.0 degrees C/sec for the 0.1 mL block • Have a block with a temperature range of 4-99.9 degrees celcius • Have a heated cover with temperature range of 50-110 degreesC 2


• Have a long-lasting bright white LED source with median lifetime of at least 60,000 hours • Have a CMOS imager for data acquisition and collects data for each filter combination in less than 2 seconds • be used with 120-240 V outlets without modification or special plug requirements • Include a heated lid assembly to heat tops of sample plates and minimize reaction evaporation.


 4.1.3 Technical specifications – Instrument onboard computer The system shall: • Possess the capability to run in stand-alone mode, without an attached computer • Include a touchscreen interface and store protocols for quick starts with no computer needed • Have a touchscreen interface that enables viewing amplification plots and filtering them by sample, target and task • Have a touchscreen interface that facilitates uploading of protocols or downloading of run files via a USB, local network and the Connect platform • Have a touchscreen interface that allows uploading of protocols and run files directly to the Connect platform • Contain onboard storage with memory capacity of 10 GB for storing 1,000-5,000 standard absolute quantification run files, and be designed for run protection in case of power outages • Be able to be customized through the touchscreen for time zones and service/calibration notification settings • Have a touchscreen interface that supports the creation of local user accounts with PIN-protected access that can be linked to the Connect platform to online accounts on thermofisher.com • Have a touchscreen interface that allows creation and running of protocols as guests • Have a touchscreen interface that allows for editing of protocols at all stages of the reaction cycle as well as block settings, temperature settings duration, ramp rate, etc. • Have a touchscreen interface that allows a template to be loaded from a USB, local network or the Connect platform • Have a touchscreen interface that allows user to enter reagent information • Have a touchscreen interface that allows a run to be paused and during that pause for the block temperature to be set as well as for the drawer to be opened and closed • Have a touchscreen interface that allows editing of sample and target assignments • Have a touchscreen interface that allows the repeat of a previous run 3 • Have a touchscreen interface that allows users to perform dye calibrations and view results on the touchscreen • Have a touchscreen interface that allows RNase P verification runs and automatically provides pass/fail results • Have a touchscreen interface that allows a user to run a self-verification test • Have a touchscreen interface that allows the user to view the cure QC assessment after calibration and RNase P plate runs are finished • Have a touchscreen interface that allows progress monitoring.


 4.1.4 Performance Requirements The instrument shall: • Complete 40-cycle real-time PCR runs using fluorogenic 5’ nuclease assay and Fast chemistry in a standard 96-well plate in less than 30 minutes as well as being able to run in standard ramping mode with standard chemistry • Include an OptiFlex system that combines four coupled excitation, and emission filter sets to allow multiplexing up to four unique wavelengths • Support at least two reaction chemistries-TaqMan® Probes and SYBR Green dye • Have real-time quantitative PCR installation specifications to be able to distinguish between 5,000 and 10,000 template copies at a 99.7% confidence level.


 4.1.5 Software Requirements The software shall: • Allow flexible customization of run protocols • Allow the creation of secure templates that are locked with a password to limit modification of run setup • Provide run monitoring of connected instruments • Include preoptimized run protocols for applications like standard curve, relative standard curve, relative quantification of gene expression, and SNP genotyping with TaqMan® or SYBR Green chemistries • Include a copy of free software to analyze data for absolute and relative quantification, SNP detection and other assays. • Collect information on both TaqMan and SYBR assays in the same run • Have a genotyping optimization tool that uses real-time data • Provide raw fluorescence data and multicomponent data for troubleshooting • Allow conversion of protocols for the Applied Biosystems StepOnePlus and 7500 to the QuantStudio 3 system protocols • Allow batch analysis of up to 500 experiments simultaneously • Can control the instrument and analyze data from a remote computer on the same network 4 • Provide status monitoring of connected instruments and real-time plots STATEMENT OF NEED (SON) • Have the ability to send user notifications when a run is started, stopped or has an error • Allow registered users of the Connect platform to monitor any connected instrument • Allow users to run an assay plate without performing plate setup prior to beginning of run and to correct plate set up after the run • Allow export of all run results to excel and save graphs as .jpg files • Provide the ability to import a standard curve from one plate for analysis of another plate of the same instrument type • Allow for the selection of endogenous controls for gene expression experiments • Include statistical analysis tools including box-whisker plots, scatter plots and heat maps • Allow preselection of data to export and the location of the exported file • Allow for command-line functions for batch exporting of analyzed run files • Allow users to save predefined analysis settings for auto-exporting run data into format of choice • Contain online high-resolution melt application so user can specify number of clusters/variants and save defined controls and analysis setting.


 4.1.6 Instrument Ecosystem The instrument ecosystem shall: • Be part of a desktop ecosystem that consists of a suite of qPCR applications. Instrument data can be grouped (multi-plate) for relative quantitation, SNP genotyping, standard curve, HRM analysis, and presence/absence analysis. • Be part of the Connect platform • Be able to connect to the Connect platform for run setup download and data uploads • Allow a run to be monitored by a web browser or mobile device • Allow batch-analysis of up to 500 experiments simultaneously through an online relative quantitation module • Provide an endogenous control selection tool for gene expression experiments in both the desktop and online quantitation software • Contain statistical anaylsis tools with both the desktop and online quantitation software • Contain a genotyping optimization tool that uses real-time data to pick the best cycle number for calling genotype in both the desktop and online genotyping software • Allow the user to specify number of clusters/variants and save defined controls and analysis settings with both desktop and online software.


 4.1.7.  Design 5 The system shall: • Have an application programming interface (API) included that allows programming routines to be developed for controlling the instrument • Be cUL, UL, CE, C-TICK, and WEEE compliant • Be developed and manufactured in a facility with quality system requirements that comply with ISO 13485 standards and ISO 9001 standards 4.1.8 Gene expression profiling • Users shall be able to select from more than 61,000 predesigned human, mouse and rat Applied BiosystemsTMTaqMan® Assays.


 4.1.9 Able to accept the trade-in of Model STEPONEPLUS. Serial number 272008444 4.1.10 Must be compatible with protocols from Applied Biosystems StepOnePlus Real Time PCR (qPCR) allowing for consistency in experimental set-up 4.2 DELIVERY / INSTALLATION The contractor shall deliver and install the equipment within thirty (30) calendar days after receipt of award.


More opportunities from Department Of Health And Human Services → National Institutes Of Health Olao

Same awarding agency

NAICS: 811210
New
Federal
Preventive Maintenance Service - GE TracerLab
Solicitation # 75N98027Q00080
The National Institutes of Health (NIH), Office of the Director, Office of Acquisitions, is seeking to award a firm-fixed-price purchase order for preventive maintenance services for two GE Healthcare TracerLab automated radiosynthesizers located at the National Heart, Lung, and Blood Institute (NHLBI) Chemistry and Synthesis Center PET Laboratory in Bethesda, Maryland. This non-competitive acquisition, conducted under FAR 12.603 and other streamlined authorities, is intended for GE Precision Healthcare LLC as the original equipment manufacturer. The scope of work requires one comprehensive preventive maintenance visit per instrument over a one-year period of performance, including system calibration, diagnostic testing, software and firmware updates, and the provision of all necessary OEM replacement parts. All services must be performed by manufacturer-authorized, factory-trained personnel during normal business hours and must comply with NIH campus security and radiation safety requirements. The contractor is required to provide a detailed written service report for each visit to certify that the systems meet original manufacturer specifications. Invoicing must be processed through the Invoicing Processing Platform using a three-way match. This requirement is classified under NAICS code 811210 and is not set aside for small businesses. Proposals must be submitted electronically to the contracting specialist by November 27, 2026.
Electronic and Precision Equipment Repair and Maintenance

POSTED

about 23 hours ago

DEADLINE

in 13 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS