Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Health And Human Services was posted on July 9, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Acquisition of an Applied Biosystems QuantStudio 3 Real-Time PCR System

Closed
75N98026Q00714Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334516
New
Federal
Temp Controlled 42 Plate Hotel
Solicitation # AB482902
Brookhaven Science Associates (BSA) is soliciting quotations for the procurement of a temperature-controlled plate storage incubator with two stackers and a built-in barcode reader, along with comprehensive on-site installation and training for integration with the Art Robbins CryCam UV imaging system at Brookhaven National Laboratory (BNL). The system must support SBS/ANSI-SLAS, low-profile SBS, and Linbro plates, maintaining temperatures between 4C and 25C. This is a small business set-aside solicitation for a firm fixed price purchase order, with the award based on the lowest total evaluated price from a responsive and responsible offeror. Quotations are due by October 2, 2026, and must remain valid for at least sixty days. The procurement includes strict shipping and pricing requirements. For items under 150lbs, shipping may occur via BSA's FedEx account; otherwise, pricing must be all-inclusive of freight, tariffs, and handling. For foreign products over 150lbs where all-inclusive pricing is unavailable, BNL will act as the Importer of Record under DAP Incoterms. Suppliers must provide the country of origin, Unique Entity Identifier (UEI), and applicable ECCN and HTS codes. All electrical equipment must be certified by a Nationally Recognized Testing Laboratory, and onsite personnel must adhere to stringent security badging and safety protocols, including specific documentation requirements for non-U.S. citizens. The contract incorporates BSA General and Supplemental Terms and Conditions for non-commercial items and onsite work, as well as various FAR clauses.
Brookhaven National Labor -Doe Contractor

POSTED

about 21 hours ago

DEADLINE

in 21 days
NAICS: 334516
New
Federal
Vibracoring System
Solicitation # 140G0126Q0293
The USGS Geological Survey Florence Bascom Geoscience Center (FBGC) is soliciting quotes under solicitation 140G0126Q0293 for the purchase of a lightweight vibra-coring system to evaluate sub-bottom stratigraphy in coastal areas, rivers, and lakes. The required system must weigh between 100 and 200 lbs, provide at least 3000 lb/ft of adjustable impact force, and exceed 1000 vibrations per minute. Technical specifications include compatibility with 3 and 4-inch core barrels, the ability to collect cores longer than 5 meters, and flexibility to switch between DC-AC or 120-220v power supplies. The procurement also includes the acquisition of a power transformer and 250 meters of cable, with all items to be delivered to Reston, VA, within 60 days after receipt of order. This is a total small business set-aside under NAICS code 334516, with a size standard of 1,000 employees. The contract will be awarded to the responsible offeror providing the lowest priced quotation that receives an acceptable technical compliance rating. Vendors must be registered in the System for Award Management (SAM) and comply with the Buy American Act. Quotes are due by September 16, 2026, with an anticipated award date of September 17, 2026. Payment will be processed electronically through the Invoice Processing Platform (IPP), and invoices must be submitted within 90 calendar days following the expiration of the period of performance.
Ofc Of Acqusition Grants-National

POSTED

about 21 hours ago

DEADLINE

in 4 days
NAICS: 334516
New
Federal
Astromaterials Glovebox Systems - Design & Fabrication (A-BOX)
Solicitation # 80JSC026A-BOX
This notice, issued by NASA’s Johnson Space Center under solicitation number 80JSC026A-BOX, is a Request for Information (RFI) for the design, fabrication, testing, delivery, and installation of controlled-atmosphere glovebox systems to support the Astromaterials Research and Exploration Science Curation Facility. The systems are intended for handling lunar and planetary samples, including those from Artemis missions, and must operate in ambient, cold (−85 to −20 °C), and ultra-cold/cryogenic (< −85 °C) environments while maintaining inert atmosphere conditions. Technical requirements are aligned with the American Glovebox Society Guidelines AGS-G001-2007 (3rd Edition), and compliance with quality standards such as ISO9001, AS9100, and NQA-1 is mandatory. The RFI seeks industry input on feasibility, capabilities, and cost estimates, with no formal proposals required. Access to the technical library containing detailed requirements is granted through SAM.gov after completing a two-step verification process and submitting a formal request form to NASA, with all requestors responsible for U.S. export control compliance. The response deadline has been extended to August 5, 2026, at 4:00 PM Central Time. The RFI emphasizes small business participation and solicit feedback on realistic subcontracting goals, barriers to entry for small businesses, and strategies to enhance involvement such as modularizing scope or encouraging teaming arrangements. NASA is considering potential set-asides for Small Business, Small Disadvantaged Business, HUBZone, Veteran-Owned, Service-Disabled Veteran-Owned, and Women-Owned Small Businesses. Organizational conflicts of interest (OCI) are a significant concern due to the nature of prior involvement in astromaterials handling and related design work; respondents must disclose any potential OCI and propose mitigation strategies, though NASA’s review at this stage does not constitute formal approval or assurance. Responses must be submitted electronically via email to the designated contracting officer and contract specialist, formatted according to Attachment II—Capabilities Questions and Responses—which addresses small business utilization, OCI, technical capability, and business considerations. The place of performance is the ARES Curation Facility in Houston, Texas, and final delivery and installation will occur there. No contract value, pricing, or award criteria are provided, as this is purely an information-gathering phase to inform future procurement strategy. Any information submitted is treated as voluntarily provided under FOIA and will not be publicly
NASA Johnson Space Center

POSTED

about 21 hours ago

DEADLINE

in 3 days
NAICS: 334516
New
Federal
Leica VT1200S Vibrating Blade - Brand name only
Solicitation # 36C25226Q0680
Solicitation 36C25226Q0680 is a brand-name-only request for quote issued by the Department of Veterans Affairs for the procurement of one new, non-refurbished Leica VT1200 S Fully Automated Vibrating Blade Microtome System. This equipment is required by the Research Department at the Jesse Brown VA Medical Center in Chicago, Illinois, to support diabetes mellitus research involving the generation of precision-cut liver slices. The procurement includes the microtome configuration, a NEMA5 15 C13 power cord, VT 1200 Silver Service, and Vibrocheck. The contract is set aside for HUBZone Small Businesses, and the award will be granted based on the Lowest Price Technically Acceptable (LPTA) offer. The successful contractor must deliver the equipment to the Jesse Brown VA Medical Center Warehouse within 30 to 45 calendar days after the award under FOB Destination terms, with shipping fees capped at 250 dollars. No onsite installation is required, but the contractor must provide the manufacturer's standard warranty. Quotes are due by September 16, 2026, at 1 PM CDT and must be submitted electronically to the contracting officer. Offerors must comply with Buy American certifications and specific security and access procedures at the delivery site. Payment will be made electronically upon receipt of the equipment.
252-NETWORK Contract Office 12 (36C252)

POSTED

about 21 hours ago

DEADLINE

in 4 days

AI Contract Overview

Show more

The National Institutes of Health, through the National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS), is seeking to acquire a single Applied Biosystems QuantStudio 3 Real-Time PCR System to replace aging StepOnePlus instruments and ensure uninterrupted research operations. This system is essential for performing nucleic acid quantification and analysis across a broad range of applications including gene expression, pathogen detection, and validation of experimental results. The instrument must match the StepOnePlus in workflow compatibility while offering enhanced capabilities such as touchscreen operation, standalone functionality, and support for both Mac and PC platforms. It must feature a 96-well 0.1 mL block with VeriFlex technology enabling up to a 10°C temperature gradient across separated zones, support reaction volumes of 10–30 μL, and execute fast PCR protocols under 30 minutes. The system must be factory-calibrated for key dyes, include a heated lid, and operate on standard 120–240 V power without modification. It must come with an onboard computer with 10 GB storage, support for USB, network, and Connect platform data transfers, and allow local user accounts with PIN access and guest mode functionality. The instrument must integrate seamlessly into the broader QuantStudio ecosystem, including cloud connectivity via the Connect platform for remote monitoring, data uploads, and batch analysis of up to 500 experiments. Software must support absolute and relative quantification, SNP genotyping, high-resolution melt analysis, and allow protocol conversion from StepOnePlus systems. It must include preoptimized templates, statistical tools like box-whisker and heat maps, and the ability to import standard curves from one plate to another. Data can be exported to Excel and saved as image files, with command-line functions for batch processing. The system must support more than 61,000 pre-designed TaqMan assays for human, mouse, and rat gene expression, and include an API for custom programming. The contractor must deliver and install the system within 30 days of award and accept trade-in of the existing StepOnePlus unit with serial number 272008444. The device must meet ISO 13485 and ISO 9001 manufacturing standards and hold regulatory certifications including UL, CE, and WEEE. All features are designed to ensure data consistency, operational efficiency, and long-term technical support.

General Info

NIAMS seeks QuantStudio 3 Real-Time PCR system to replace aging StepOnePlus, ensuring seamless workflow, fast PCR, cloud connectivity, and full compatibility.

Agency

Department Of Health And Human Services → National Institutes Of Health OlaoView Agency

NAICS

334516 - Analytical Laboratory Instrument ManufacturingView NAICS

Place of Performance

Bethesda, MD, 20892, USA

Set-Aside

NONE

Documents

(1)

NIAMS QuantStudio 3 Real-Time PCR System Requirements Rev8

DOCXsow

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Health And Human Services → National Institutes Of Health Olao
Contacts1 person available
OfficeBETHESDA, MD, 20892, USA
Organization / Agency
Department Of Health And Human Services → National Institutes Of Health Olao
View Agency Profile
Office AddressBETHESDA, MD, 20892, USA
Contacts

Full Description

Show more

Requirements:


To ensure continuity of research, NIAMS proposes the acquisition of an Applied Biosystems QuantStudio 3 Real-Time PCR System. qPCR is a core technology used for nucleic acid amplification, quantification, and analysis and supports a wide range of research applications, including gene expression studies, pathogen detection, transcript quantification, and validation of experimental results. The QuantStudio 3 is the closest replacement to the current StepOnePlus systems, allowing researchers to maintain established workflows and consistency in experimental design and data interpretation. The QuantStudio 3 offers several operational advantages, including user-friendly software, compatibility with both Mac and PC platforms, touchscreen operation, and the ability to function as a standalone instrument or in conjunction with a computer. Its thermal block design is similar to the existing systems, minimizing the learning curve for users and supporting a broad range of genomic applications. In addition, the manufacturer offers trade-in credit for the current instruments, reducing the overall acquisition cost while providing access to a fully supported platform with available parts and technical support. Acquiring the QuantStudio 3 at this time will help prevent interruptions to research activities, maintain reliable and consistent data generation, and ensure that NIAMS laboratories have access to a supported and dependable qPCR platform.


4.1 PRODUCT FEATURES/SALIENT CHARACTERISTICS The contractor shall provide one Applied Biosystems QuantStudio 3 Real-Time PCR System or an equal system that meets all the following minimum requirements. 4.1.1. System Features/Benefits The system shall: • Utilize a platform providing 1 TB or storage space for data sharing at user discretion • be used with online scientific apps • come with desktop-based software, allowing single-plate run setup and analysis.


4.1.2. Technical specifications – Instrument The instrument shall: • have a 96 well 0.1 ml plate block format and the option to run fast protocols <30 minutes • not require a field service engineer for set up by end user. Set up should be easy for end user – directly out of the box. • not require a computer for installation • use an RNase P verification plate to verify performance • not require dye calibration upon installation • have dimensions fo 27 x 50 x 40 cm and be designed to maximize horizonal and vertical bench space • be capable of analyzing 96 samples simultaneously in various formats incluing both 96-well plates, 8-tube strips and individual tubes • the 96-well block should be made of at least 3 separated Peltier elements – VeriFlex Blocks. The maximum temperature difference programmable across the block should be 10 degrees C. 5 degrees C should be the maximum difference in temperature allowed between adjacent blocks. • Support reaction volumes of 10-30 uL on 0.1mL the 96-well block • Be factory calibrated with FAM, SYBR Green 1, VIC, NED, ABY, JUN, TAMRA, and ROX dyes • Have melt or dissociation curves that take place in steps with deltaT varying between 0.015 degrees C and 3.66 degrees C • Have a maximum block ramp rate of 9.0 degrees C/sec for the 0.1 mL block • Have a block with a temperature range of 4-99.9 degrees celcius • Have a heated cover with temperature range of 50-110 degreesC 2


• Have a long-lasting bright white LED source with median lifetime of at least 60,000 hours • Have a CMOS imager for data acquisition and collects data for each filter combination in less than 2 seconds • be used with 120-240 V outlets without modification or special plug requirements • Include a heated lid assembly to heat tops of sample plates and minimize reaction evaporation.


 4.1.3 Technical specifications – Instrument onboard computer The system shall: • Possess the capability to run in stand-alone mode, without an attached computer • Include a touchscreen interface and store protocols for quick starts with no computer needed • Have a touchscreen interface that enables viewing amplification plots and filtering them by sample, target and task • Have a touchscreen interface that facilitates uploading of protocols or downloading of run files via a USB, local network and the Connect platform • Have a touchscreen interface that allows uploading of protocols and run files directly to the Connect platform • Contain onboard storage with memory capacity of 10 GB for storing 1,000-5,000 standard absolute quantification run files, and be designed for run protection in case of power outages • Be able to be customized through the touchscreen for time zones and service/calibration notification settings • Have a touchscreen interface that supports the creation of local user accounts with PIN-protected access that can be linked to the Connect platform to online accounts on thermofisher.com • Have a touchscreen interface that allows creation and running of protocols as guests • Have a touchscreen interface that allows for editing of protocols at all stages of the reaction cycle as well as block settings, temperature settings duration, ramp rate, etc. • Have a touchscreen interface that allows a template to be loaded from a USB, local network or the Connect platform • Have a touchscreen interface that allows user to enter reagent information • Have a touchscreen interface that allows a run to be paused and during that pause for the block temperature to be set as well as for the drawer to be opened and closed • Have a touchscreen interface that allows editing of sample and target assignments • Have a touchscreen interface that allows the repeat of a previous run 3 • Have a touchscreen interface that allows users to perform dye calibrations and view results on the touchscreen • Have a touchscreen interface that allows RNase P verification runs and automatically provides pass/fail results • Have a touchscreen interface that allows a user to run a self-verification test • Have a touchscreen interface that allows the user to view the cure QC assessment after calibration and RNase P plate runs are finished • Have a touchscreen interface that allows progress monitoring.


 4.1.4 Performance Requirements The instrument shall: • Complete 40-cycle real-time PCR runs using fluorogenic 5’ nuclease assay and Fast chemistry in a standard 96-well plate in less than 30 minutes as well as being able to run in standard ramping mode with standard chemistry • Include an OptiFlex system that combines four coupled excitation, and emission filter sets to allow multiplexing up to four unique wavelengths • Support at least two reaction chemistries-TaqMan® Probes and SYBR Green dye • Have real-time quantitative PCR installation specifications to be able to distinguish between 5,000 and 10,000 template copies at a 99.7% confidence level.


 4.1.5 Software Requirements The software shall: • Allow flexible customization of run protocols • Allow the creation of secure templates that are locked with a password to limit modification of run setup • Provide run monitoring of connected instruments • Include preoptimized run protocols for applications like standard curve, relative standard curve, relative quantification of gene expression, and SNP genotyping with TaqMan® or SYBR Green chemistries • Include a copy of free software to analyze data for absolute and relative quantification, SNP detection and other assays. • Collect information on both TaqMan and SYBR assays in the same run • Have a genotyping optimization tool that uses real-time data • Provide raw fluorescence data and multicomponent data for troubleshooting • Allow conversion of protocols for the Applied Biosystems StepOnePlus and 7500 to the QuantStudio 3 system protocols • Allow batch analysis of up to 500 experiments simultaneously • Can control the instrument and analyze data from a remote computer on the same network 4 • Provide status monitoring of connected instruments and real-time plots STATEMENT OF NEED (SON) • Have the ability to send user notifications when a run is started, stopped or has an error • Allow registered users of the Connect platform to monitor any connected instrument • Allow users to run an assay plate without performing plate setup prior to beginning of run and to correct plate set up after the run • Allow export of all run results to excel and save graphs as .jpg files • Provide the ability to import a standard curve from one plate for analysis of another plate of the same instrument type • Allow for the selection of endogenous controls for gene expression experiments • Include statistical analysis tools including box-whisker plots, scatter plots and heat maps • Allow preselection of data to export and the location of the exported file • Allow for command-line functions for batch exporting of analyzed run files • Allow users to save predefined analysis settings for auto-exporting run data into format of choice • Contain online high-resolution melt application so user can specify number of clusters/variants and save defined controls and analysis setting.


 4.1.6 Instrument Ecosystem The instrument ecosystem shall: • Be part of a desktop ecosystem that consists of a suite of qPCR applications. Instrument data can be grouped (multi-plate) for relative quantitation, SNP genotyping, standard curve, HRM analysis, and presence/absence analysis. • Be part of the Connect platform • Be able to connect to the Connect platform for run setup download and data uploads • Allow a run to be monitored by a web browser or mobile device • Allow batch-analysis of up to 500 experiments simultaneously through an online relative quantitation module • Provide an endogenous control selection tool for gene expression experiments in both the desktop and online quantitation software • Contain statistical anaylsis tools with both the desktop and online quantitation software • Contain a genotyping optimization tool that uses real-time data to pick the best cycle number for calling genotype in both the desktop and online genotyping software • Allow the user to specify number of clusters/variants and save defined controls and analysis settings with both desktop and online software.


 4.1.7.  Design 5 The system shall: • Have an application programming interface (API) included that allows programming routines to be developed for controlling the instrument • Be cUL, UL, CE, C-TICK, and WEEE compliant • Be developed and manufactured in a facility with quality system requirements that comply with ISO 13485 standards and ISO 9001 standards 4.1.8 Gene expression profiling • Users shall be able to select from more than 61,000 predesigned human, mouse and rat Applied BiosystemsTMTaqMan® Assays.


 4.1.9 Able to accept the trade-in of Model STEPONEPLUS. Serial number 272008444 4.1.10 Must be compatible with protocols from Applied Biosystems StepOnePlus Real Time PCR (qPCR) allowing for consistency in experimental set-up 4.2 DELIVERY / INSTALLATION The contractor shall deliver and install the equipment within thirty (30) calendar days after receipt of award.


More opportunities from Department Of Health And Human Services → National Institutes Of Health Olao

Same awarding agency

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS