Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

This Award Notice opportunity from Department of Health and Human Services was posted on September 29, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Adaptive Mechanical Models for Realistic Radiation Sterilization Simulations

Awarded
SBIR / STTR
Solicitation #
203788

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Food and Drug Administration has awarded a Phase I SBIR contract for the project titled Adaptive Mechanical Models for Realistic Radiation Sterilization Simulations. The initiative aims to shift sterilization validation from a late-stage trial-and-error process to an early-stage Design for Sterilization approach by utilizing computational simulations. By integrating simulation tools early in the development cycle, medical device companies can analyze potential sterilization failures as soon as a CAD model exists, reducing the reliance on physical prototypes and rules-of-thumb. To achieve this, the project focuses on developing a software tool capable of generating a family of CAD models that reflect the realistic range of device orientations and positions within sterile packaging, accounting for gravity and other physical forces. Additionally, the project involves the creation of a custom phantom to compare measured and simulated radiation doses. This comparative study will validate the approach, ultimately improving the accuracy of radiation sterilization simulations and streamlining the regulatory validation process for medical devices.

General Info

FDA Phase I SBIR contract for computational radiation sterilization simulations for medical devices.

Contract Value

$189,703.29

NAICS

N/A

Place of Performance

CA, USA

Set-Aside

NONE

Award Issued Date

Contract End Date

September 28, 2025

Documents

0

No documents available

This contract was awarded without public documents.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

PhaseAwarded
Posted

Award Notice

Awarded

Contract was awarded

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment of Health and Human Services → Food and Drug Administration
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Project Summary Medical Device development has an underlying paradigm to reduce risk early in the development cycle. Developers are using computational tools such as finite element analysis to mitigate risks from thermal loads, mechanical stresses etc. There is one exception to this paradigm: sterilization validation. Sterilization validation is addressed late in the development cycle as an actual physical device is needed to perform these activities. Sterilization configurations (e.g., packaging design, radiation beam direction, etc.) are iteratively modified until the regulatory requirements are met. This “trial-and-error” approach is prevalent throughout all aspects of sterilization. As another example, when choosing between sterilization modalities, medical device companies often rely on rules-of-thumb which may lead to a suboptimal choice for their device. However, use of simulations to model the radiation sterilization process is an emerging field that has the promise to address sterilization validation early in the development process and thereby allow for a Design for Sterilization approach. That means as soon as a Computer Aided Design (CAD) model of the device exists, simulation can be performed to analyze whether the device will pass sterilization validation or mitigations will be needed. While simulations are a key ingredient to address sterilization early in the design process, we find that a single representation of the device might not be sufficient to tell the whole story. Sterile packaging is another important factor that needs to be considered. The package determines how the device is presented to the radiation beam, but within the package the device can move to a certain degree with separate parts of the device also can move against each other. Thus, there is a range of possible orientations and positions of the device that will influence the overall radiation dose that the device will receive. In this project we propose to develop a software tool that can generate a family of CAD models that spans the realistic range of device orientations and positions expected from packaging constraints and device configuration. The tool will account for gravity and other forces to realistically describe the range of possible configurations. We also will develop a custom phantom that can be used in simulations and in measurements to explore the range of dose received. The comparative study of measured and simulated dose will be used to overall validate our approach. The new tool developed under this project will improve the utility of radiation sterilization simulations and pave the path for Design for Sterilization.

Get AI-powered intelligence on the opportunities still open

Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.

Miguel
Hillary
Keith Deutsch
Christine

Join 900+ contractors already using CLEATUS