Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

This Award Notice opportunity from Department of Health and Human Services was posted on September 30, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Air Plasma Sterilization Device with Plasma-in-Lumen Technology

Awarded
SBIR / STTR
Solicitation #
219236

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

Advanced Cooling Technologies, Inc. is developing a novel dry air plasma sterilization system for flexible endoscopes to replace toxic Ethylene Oxide and limited Vaporized Hydrogen Peroxide methods. The technology features a sheet plasma reactor embedded in flexible pouches, Plasma-in-Lumen technology for devices of arbitrary length, and a chamber-free compact design for centralized control. Phase I successfully demonstrated feasibility using biological indicators and process-challenging devices, marking the first global confirmation of air plasma sterilization via these standards. Under this Phase II award from the Food and Drug Administration, the project aims to build a full-feature system including reusable pouches and automation components. Key objectives include validating consistent sterilization performance, ensuring long-term material compatibility, developing high-throughput operations, and exploring alternative gas sources. Beyond medical applications, the technology holds commercial potential for space mission planetary protection and other sectors requiring non-toxic, efficient sterilization.

General Info

FDA Phase II award to develop non-toxic dry air plasma endoscope sterilization systems.

Contract Value

$999,890

NAICS

N/A

Place of Performance

PA, USA

Set-Aside

NONE

Award Issued Date

Contract End Date

August 31, 2027

Documents

0

No documents available

This contract was awarded without public documents.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

PhaseAwarded
Posted

Award Notice

Awarded

Contract was awarded

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment of Health and Human Services → Food and Drug Administration
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Abstract Flexible endoscopy is widely used in diagnostic and therapeutic procedures for digestive diseases. However, current endoscope sterilization technologies can be labor intensive, have high health and environmental impacts, or have constraints in endoscope dimensions. Specifically, the mainstream approach Ethylene Oxide (EtO) is facing significantly tightened regulations due to its high toxicity and carcinogenicity, and alternatives such as Vaporized Hydrogen Peroxide (VHP) technologies are unable to sterilize lumens with >1 m length while suffering from moisture-induced sterilization failure. To tackle the challenge, Advanced Cooling Technologies, Inc. develops a novel dry air plasma sterilization system that can perform automated endoscope sterilization without lumen length constraints or toxic gas emission. Major innovations include 1) Sheet plasma reactor design that is embedded in a flexible pouch for enhanced sterilization and combined storage; 2) Plasma-in-Lumen technology that directly delivers sterilant into the lumens with arbitrary length; and 3) Chamber-free compact system design that allows a centralized control unit to operate multiple pouches with a flexible sterilization scheduling. Further, the system is compatible with various gas sources, including dry air, oxygen-rich air, and VHP for future commercialization. In Phase I, we conducted a series of prototype development on both the component (pouch reactor and Plasma- in-Lumen technology) and system levels to demonstrate the feasibility of the concept. The sterilization/disinfection of the medical devices was successfully confirmed by the industrial field-standard self- contained biological indicators (SCBIs) inoculated with G. stearothermophilus spores combined with process- challenging devices (PCDs). Our work is the first in the world to successfully confirm air plasma sterilization via SCBI and PCD. We also evaluated alternative gas sources to achieve a sterilization cycle time shorter than that with the VHP system. In potential Phase II, our goal is to develop a full-feature system that can achieve reliable sterilization of endoscopes and other medical devices. Four Aims are strategically designed to achieve this goal: Aim 1) Build a complete sterilization system with all the peripherals including a high-quality, reusable pouch with sheet plasma reactors, Plasma-in-lumen reactors, and all safety and automation components. Aim 2) Perform and validate consistent sterilization performance and long-term material compatibility. Aim 3) Develop high-throughput operations. Aim 4) Explore alternative gas sources. The recently tightened EtO emission regulation provided a unique commercialization potential for alternative approaches such as plasma. Our technology can also be used in other applications such as planetary protection for space missions, etc., further expanding commercialization opportunities with simplified regulatory pathways.

Get AI-powered intelligence on the opportunities still open

Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.

Miguel
Hillary
Keith Deutsch
Christine

Join 900+ contractors already using CLEATUS