Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Florida was posted on August 22, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Airside E Cooling Tower Refurbishment Phase 2

Closed
7310 24*State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The contract pertains to the refurbishment of the cooling towers serving Airside E, which have reached the end of their operational lifespan. The scope of work, designated as Phase 2, involves the removal and replacement of critical components including piping, manual and equalizing valves, control valves, and piping accessories such as vibration compensators, temperature and pressure sensors. Additionally, measures will be taken to mitigate plume entrainment by installing intake louvers. The project aims to enhance the reliability and efficiency of the cooling system, ensuring compliance with relevant standards and addressing aging infrastructure. The contract is managed by the Planning and Development agency in Florida, with a project size estimated between $500,000 and $1,500,000, and responses are due by October 3, 2024. This procurement is part of a broader effort to maintain and upgrade essential airport infrastructure, with a primary point of contact being Rianner Woodard. The project emphasizes technical precision and adherence to safety and environmental standards, reflecting a comprehensive approach to infrastructure refurbishment. The detailed scope and technical requirements indicate a focus on ensuring the cooling towers operate effectively and reliably, supporting the overall airside operations. The contract's timeline and scope underscore the importance of timely execution to prevent operational disruptions and extend the lifespan of critical cooling components at the airport facility.

General Info

Agency

Florida → Planning and Development

Place of Performance

FL, USA

Set-Aside

NONE

Documents

7

Airside E Cooling Tower Refurbishment – Phase 2

PDF, High priority: read this firstitb
High

Airside E Cooling Tower Refurbishment - Phase 2 Division 01 General Requirements

PDF, High priority: read this firstspecifications
High

Airside E Cooling Tower Refurbishment – Phase 2 (Project 7310 24)

PDF, High priority: read this firstifb
High

Hillsborough County Aviation Authority Change Order Form

PDF, High priority: read this firstmodification
High

Tampa International Airport Airside E Cooling Tower Refurbishment Technical Specifications

PDF, High priority: read this firstspecifications
High

Tampa International Airport - Safety, Traffic, and Security Notes

PDF, High priority: read this firstspecifications
High

Aviation Authority Application for Payment

PDF, Low prioritypayment-application
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyFlorida → Planning and Development
Contacts1 person available
OfficeN/A
Organization / Agency
Florida → Planning and Development
Office AddressN/A

Full Description

Show more
The components associated with the cooling towers serving Airside E have reached the end of their useful life and require refurbishment. The Phase 2 scope of work includes the removal and replacement of piping, manual and equalizing valves, control valves, and piping accessories such as vibrations compensation, temperature and pressure sensors, and mitigating plume entrainment by adding intake louvers.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS