Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Tennessee was posted on March 23, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Aluminum Fluted Shaft

Closed
Z4139State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The contract calls for the supply of a 16-foot aluminum fluted post designed for outdoor lighting and banner mounting, manufactured by Hadco or Banner. The post features a fluted aluminum shaft with a diameter between 5 and 6 inches, topped with a heavy-duty cast aluminum fitter welded at the top. The base is constructed from cast aluminum reinforced with structural schedule 80 pipe to enhance strength and provide a damping effect. It includes a large access hand hole for easy mounting and wiring, with a ground screw installed opposite the hand hole. The post is anchored using 3/4" or 1" stainless steel anchor bolts within a bolt circle of 11.5 to 12.5 inches and is finished with a durable black polyurethane coating. The post is engineered to support a single luminaire or two luminaires on twin cross arms, as well as two 20" x 60" banners, though banner arms are not included in the bid and must be considered in the post’s design strength. The maximum permitted luminaire size is 1.6 square feet in effective projected area, weighing up to 60 pounds and approximately 36 inches high. The product must be certified by a licensed professional engineer to withstand wind loads of up to 80 mph with gusts reaching 104 mph, though certification may be waived if specifications remain unchanged from previous purchases and a waiver request is submitted. The contract is issued by Nashville Electric Service in Tennessee, with responses due by March 30, 2026.

General Info

Supply of 16-foot aluminum fluted post for lighting and banners, certified for 80 mph wind.

Documents

1

Z4139_RFB - Stand Aluminum Fluted 16 Ft Hadco/Banner

PDF, High priority: read this firstrfb
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyTennessee → Nashville Electric Service
Contacts1 person available
OfficeNashville, TN, USA
Office AddressNashville, TN, USA
Contacts
Shanna FaulkProcurement Contact

Full Description

Show more
STAND AL FLUTED 16 FT HADCO/BANNER STAND AL FLUTED 16FT HADCO/BANNER POST S HALL HAVE AN ALUMINUM FLUTED SHAFT WITH A HEAVY DUTY CAST ALUMINUM FITTER, 3" O. D. X 3" LONG, WELDED AT THE TOP. POST HEIGHT SHALL BE 16 FEET AND THE SHAFT DIAMETER SHALL BE 5" TO 6". THE POST BASE SHALL BE CONSTRUCTED OF CAST ALUMINUM WITH REINFORCED STRUCTRUAL SCHEDULE 80 PIPE TO INCREASE THE STRUCTURAL STRENGTH OF THE POLE SYSTEM AND PROVIDE A DAMPING EFFECT ON THE POST SHAFT. THE POST BASE SHALL HAVE A LARGE HAND HOLE WITH EASY ACCESS TO ALLOW MOUNTING AND WIRING TO BE ACCOMPLISHED EASILY. GROUND SCREW SHALL BE MOUNTED ON THE INSIDE BACK OF THE BASE ACROSS FROM THE HAND HOLE. POST MOUNTING SHALL BE WITH 3/4" OR 1" ANCHOR BOLTS ON A BOLT CIRCLE FROM 11.5" TO 12.5". ALL HARDWARE SHALL BE STAINLESS STEEL. POLE AND HARDWARE SHALL BE FINISHED WITH A BLACK POLYURETHANE COATING. THE POST SHALL BE ABLE TO ACCOMODATE A SINGLE LUMINAIRE OR 2 LUMINAIRES ON TWIN CROSS ARMS, & 2 20" X 60" BANNERS. THE BANNER ARMS ARE NOT INCLUDED IN THE BID, BUT ARE TO BE CONSIDERED FOR POST STRENGTH REQUIREMENT. MAXIMUM SIZE OF THE LUMINAIRE TO BE USED ON THIS POST IS 1.6 SQ. FT. EPA, 60 POUNDS, AND APPROXIMATELY 36" HIGH. THE POST SHALL BE MET AND CERTIFIED BY A LICENSED PROFESSIONAL ENGINEER FOR A WIND LOADING OF 80 MPH WITH GUST UP TO 104 MPH. THE POST CERTIFICATION MAY BE WAIVED IF THERE IS NO CHANGE FROM THE PREVIOUS PURCHASE AND IF A WAIVER IS REQUESTED. Approved Manufacturers and/or Part Numbers: PHILIPSSP5442V-16A(DWG10)

More opportunities from Tennessee → Nashville Electric Service

Same awarding agency

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS