Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Defense was posted on January 19, 2017. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Avian Array Line Repair - John Day Dam

Awarded
W9127N-17-R-0007Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 237990
New
SLED
Pennsauken Community Pool Improvements
Solicitation # 2026-BID-15
The Township of Pennsauken, New Jersey, is soliciting bids for the complete rehabilitation and improvement of the Pennsauken Community Pool under solicitation number 2026-BID-15. The scope of work includes significant structural improvements to the pool, the demolition and construction of the pool mechanical room, electrical upgrades, and the installation of plumbing and other general complex upgrades. Specific deliverables include reinforced concrete flooring and walls, sandblasting the pool interior, and the installation of two 25 by 25 foot shade structures. All work must adhere to the 2019 NJDOT Standard Specifications for Road and Bridge Construction, the Americans with Disabilities Act of 1990, and New Jersey Prevailing Wage Act requirements. Bids must be submitted electronically via the OpenGov Procurement Portal by November 10, 2026, at 10:30 AM. The contract will be awarded to the lowest qualified responsible bidder. Submission requirements include a bid bond of 10 percent not to exceed 20,000 dollars, a notarized Non-Collusion Affidavit, a Certificate of Non-Debarment, and signed acknowledgments for Addenda 01 and 02. The successful contractor must provide a performance bond within three days of the contract award. The initial contract period is one year, with a possible one-year extension upon mutual agreement. Payment will be processed through the Township Governing Body following certification by the Township Engineer and the submission of itemized invoices and certified payrolls.
Procurement

POSTED

about 17 hours ago

DEADLINE

in 11 days

AI Contract Overview

Show more

The Avian Array Line Repair project at John Day Dam, identified by solicitation number W9127N-17-R-0007, is managed by the Department of Defense through the W071 Endist Portland office. This contract focuses on the repair and rope reinstallation of avian lines, with technical specifications guided by Drawing G-100. Prospective bidders are cautioned that while the plan view on Drawing G-100 serves as a reference for which lines require replacement, the horizontal span distances should be verified using the table in the upper right hand corner, which is based on a previous inspection report. To ensure a proposal is considered responsive, submitters must include signed copies of all SF-30 forms. The project falls under NAICS code 237990 and is coordinated by Contract Specialist Patrick Collins. All administrative inquiries and proposal submissions are handled through the designated Department of Defense channels in Portland, Oregon.

General Info

Contract Value

$212,576

NAICS

237990 - Other Heavy and Civil Engineering Construction

Place of Performance

OR, USA

Set-Aside

NONE

Award Issued Date

Documents

16

A.01.23_JDD1_109_G100XXX_Draft.pdf

PDF

A.01.28_PWS_John_Day_Avian_Array_Improvements_Phase_I_Draft_02.pdf

PDF

A.07.23_W9127N-17-R-0007_Avian_Array_Rope_Replacement_RFP.pdf

PDF

A.07.24_Amendment_01_SF30.pdf

PDF

A.07.24_Amendment_03_SF30.pdf

PDF

A.07.24_Amendment_04_SF30.pdf

PDF

A.07.24_Revised_S-500_JDD1.109_G500XXX.pdf

PDF

A.07.24_W9127N-17-R-0007_Am_0002_Avian_Array_Rope_Replacement.pdf

PDF

Appendix_E_-_Reference_As-Builts.pdf

PDF

Attachment_A_-_Drawing_Packet.pdf

PDF

Attachment_B_CDR_dd2772.pdf

PDF

Attachment_C_-_BRZ.pdf

PDF

Attachment_D_-Rev_01_05_Dec_Vectran_Factory_Cut_Length_Material_Properties.pdf

PDF

Attachment_D_-_Vectran_12_Strand_Factory_Cut_Length_per_Line.pdf

PDF

JDD1.109_S500XXX.pdf

PDF

Question_Responses.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

5 updates
PhaseAwarded
Posted

Presolicitation

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Notice updated

Response deadline changed from Dec 14, 2016 to Dec 13, 2016. The notice description changed.

Type Changed

Presolicitation → Solicitation

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W071 Endist Portland
Contacts1 person available
OfficePORTLAND, OR, 97204-3495, USA
Office AddressPORTLAND, OR, 97204-3495, USA
Contacts
Patrick CollinsContract Specialist

Full Description

Show more
The following questions about the solicitation were submitted and have been addressed below. Numbering is continued from the previous set of questions. ---Two (2) amendments (SF-30), amendment 0003 and amendment 0004, are also issued and attached. For a proposal to be responsive, signed copies of ALL SF-30's must be submitted with the proposal.--- --Amendment 0003 Revises Attachment D and extends the proposal due date-- --Amendment 0004 Revises the PWS-- 9. What is the height (elevation of MSL) and width of the lower NAVLOCK guide wall extensions? Both (Both the wide guide wall between towers N3 and N2, and the narrow guide wall between towers N2 and N1) of the lower NAVLOCK guide wall extensions between the North towers N3 and N2, then between N2 and N1 ANSWER: Elevation, span, and connection details of the North Shore Carrier line connections can be found in Appendix E, Drawing Packet 29026-001. 10. I do not see in any of the drawings, whether the new solicitation drawings or the reference drawings how far are from lower NAVLOCK guide wall extension from the N1, N2 and N3 North Peninsula towers. Could the contractor put a JLG aerial boom on a barge, on the North side of the lower NAVLOCK guide wall extension and reach over to the 1 1/8" Carrier line to re-terminate the 3/16" Vectran rope without having to get into the possible turbulent waters below the spillway, just long enough to pull the lines across and terminate them. Time would probably have to be scheduled with the lock operators in order to do this? ANSWER: Refer to Revised PWS (Amendment 04), Section 5.2. 11. Concerning the 1/4" x 1 1/4" Flared Soft Copper Sleeve that is called out for terminating the 3/6 Vectran rope on the winches on the lock wall. This is for rope no's. 39, 45, 54, 56, 59, 60 as shown on Drawing Sheet No. 29026-011, Sheet No. 1 of 7. Who is the manufacturer of these 1/4" x 1 1/4" Flared Soft Copper Sleeves and part number OR can regular 1/4" ID x 3/8" OD copper tubing from McMaster-Carr be used, such as their no. 8967K89? ANSWER: The item call out is standard 1/4" soft copper sleeve. Contractor shall coordinate with COR for approved part item. 12. Because of the answers to earlier questions saying that there was 17 failures of the existing ropes between the years 2015 and 2016 this leads me to believe there has been a lot more failures. What other rope numbers have failed? ANSWER: As of 10/27, 28 lines are reported missing. 13. Concerning the solicitation with Attachment "D". The Attachment "D" list does not show rope no's. 73 & 77 as being Cut and furnished to the USACE's from Cortland Cable. Have these actually been furnished by Cortland to the USACE's since all of the other paper work does show this work to be done? ANSWER: Lines 73 and 77 are also furnished from Cortland Cable Co. See Appendix D for changes. 14. Concerning where the Oregon South shore towers EE, WE, S2, S3 and S4 are located in regards to getting into them with a trailer with the spools of GFM (Cortland Cables 3/16" Vectran rope) rope to be able to set up and pay or feed them out across the Columbia river. Is there any problem with backing a trailer up to where needed to be able to do the foregoing work? Specialty just South of towers WE, S2 and S3? ANSWER: Refer to PWS, Section 6.3 and 9.1.3 for location access and equipment placement. 15. From the solicitation ITEM NO. 0002, Perform Survey. Is this work to be Surveying done by a licensed "Land Surveyor" along with the installing contractor while adjusting the ropes so that the minimum elevation of the ropes at their lowest sage point is at a MSL of 185 ft.? Also with this work is there a BENCH MARK in the South Shore area with a known ELEVATION, in order to work from for making the final adjustments at the 185 ft. MSL? ANSWER: Surveying does not need to be performed by a licensed "Land Surveyor." Surveying method shall be completed using standard surveying practices and equipment with approval by the COR prior to surveying. Refer to PWS, Section 6.3. Anchor connections are called out in Appendix E with known Elevations. Contractor can coordinate with COR to determine additional South Shore elevation bench marks if necessary.

More opportunities from Department Of Defense → W071 Endist Portland

Same awarding agency

NAICS: 238220
New
Federal
John Day Dam Powerhouse HVAC Upgrades
Solicitation # W9127N26BA006
The U.S. Army Corps of Engineers Portland District is seeking a single firm-fixed-price contract for comprehensive HVAC upgrades at the John Day Dam Powerhouse, located across Oregon and Washington. The project involves replacing primary and secondary chillers, installing four new chiller skid packages with approximately 600 tons of refrigeration capacity, and implementing a new automated digital HVAC control system. Key technical requirements include a mix of water-cooled and air-cooled systems, new intake and exhaust ducting for fire smoke propagation prevention, and the installation of mini-split units. The work must be performed within an active powerhouse containing high-voltage electrical equipment and areas prone to water intrusion, with a construction period of 1,004 calendar days. The estimated project magnitude is between 25 million and 100 million dollars under NAICS code 238220. A critical condition for award is compliance with Cybersecurity Maturity Model Certification, specifically CMMC Level 2 (Self) for the prime contractor and appropriate levels for subcontractors based on the type of information processed. The solicitation is expected to be issued as an Invitation for Bids in mid-September 2026, requiring bidders to have an active SAM registration and a current NIST SP 800-171 assessment.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

1 day ago

DEADLINE

N/A
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS