BAEY 240015 - Replace Fire Pump Controllers

Closed
BAEY240015Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

541330 - Engineering Services

Place of Performance

Beale AFB, CA, 95903, USA

Set-Aside

SBA

Documents

3

BAEY 240015 – Upgrade Fire Pump Controllers B11600 SOW

PDF, High priority: read this first27 pages · sow
High

B11600 Site Plan

PDF, Low priority1 page · other
Low

Sources Sought Questionnaire - Upgrade Fire Pump Controllers B11600

DOCX, Low priority1 page · sources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA4686 9 Cons Pk
Contacts2 people available
OfficeBEALE AFB, CA, 95903-1702, USA
Office AddressBEALE AFB, CA, 95903-1702, USA

Full Description

Show more
This contract opportunity serves as a presolictation for the following requirement: BAEY 240015 Upgrade Fire Pump Controllers at B11600 located at Beale Air Force Base (AFB), California. The services to be performed shall include demolition of the existing fire alarm system and fire pump controllers, design and construction of a new fire alarm system and fire pump controllers. Project also includes installation of a ductless split system air conditioner with programmable thermostat. See site map for location and layout. Building 11600 pump house provides dedicated fire water for aircraft hangars 1-6. The site arrangement includes two water storage tanks and an associated water pumping facility that houses three electric fire pumps and two electric jockey pumps with associated controllers. The pump house facility was constructed in 2004. Subsequent projects have replaced selected equipment within the pumphouse except for the fire pump controllers. They are old and out of compliance with current standards and need replacement. The current fire alarm system does not provide adequate monitoring of the fire pump system which has resulted in reoccurring damage to fire equipment. The fire alarm system is out of compliance with current cyber security regulations and the space where the FACP is located is not properly temperature controlled. Improper reporting by the fire alarm system and old fire pump controllers pose a serious risk to the operability and maintainability of the system. The Contractor shall furnish all design, labor, supervision, transportation, materials, testing, analysis, reports, permits, hauling, tools, equipment, disposal, and professional services to accomplish all the work involved to construct the project described in section 1.2. The completed project shall result in a fully functional and code compliant fire alarm system and fully operable/functional electric fire pump controllers meeting all government and industry standards. This Notice will serve to satisfy synopsis requirements outlined in FAR 5.204. If there are any NAICS or PSC code that do not match the presolicitation posting and your company is able to fullfill this requirement please provide the approrpiate information in the Sources Sought Questionnare. Should there be any questions about the the Statement of Work or the accompanying documents, please notify the CA/CO.

More opportunities from Department Of Defense → FA4686 9 Cons Pk

Same awarding agency

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS