Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

BALL KIT, CERAMIC

Active
N0010426QFD00Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

NAICS

332919 - Other Metal Valve and Pipe Fitting Manufacturing

Place of Performance

PA

Set-Aside

NONE

Documents

1

RFQ NO00104-26-Q-FD00 - Ball Kit, Ceramic

PDF, High priority: read this firstrfq
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseSolicitation
Posted

Solicitation

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Navsup Weapon Systems Support Mech
Contacts1 person available
OfficeMECHANICSBURG, PA, 17050-0788, USA
Office AddressMECHANICSBURG, PA, 17050-0788, USA
Contacts

Full Description

Show more
CONTACT INFORMATION|4|N743.49|WVT|771-229-0573|benjamin.t.spangler.civ@us.navy.mil| ITEM UNIQUE IDENTIFICATION AND VALUATION (JAN 2023)|19|||||||||||||||||||| HIGHER-LEVEL CONTRACT QUALITY REQUIREMENT (DEC 2014)|1|See specification sections C and E.| INSPECTION OF SUPPLIES--FIXED-PRICE (AUG 1996)|2||| INSPECTION AND ACCEPTANCE - SHORT VERSION|8||||||||| GENERAL INFORMATION-FOB-DESTINATION|1|B| WIDE AREA WORKFLOW PAYMENT INSTRUCTIONS (JAN 2023)|16|Stand-Alone Receiving Report - Certifications Combo - Receiving Report & Invoice - Material |N/A|TBD|N00104|TBD|N39040 - Certifications, S4306A - Material |N50286|TBD|133.2|N/A|N/A|N39040 - Certifications |N/A |N/A|SEE DD FORM 1423 |PORT_PTNH_WAWF_NOTIFICATION@NAVY.MIL BENJAMIN.T.SPANGLER.CIV@US.NAVY.MIL| NAVY USE OF ABILITYONE SUPPORT CONTRACTOR - RELEASE OF OFFEROR INFORMATION (3-18))|1|| MANDATORY USE OF WORKFLOW PRO (WFP) MOD ASSIST MODULE|1|| WARRANTY OF SUPPLIES OF A NONCOMPLEX NATURE (JUNE 2003)|6|One year from date of delivery.|One year from date of delivery.||||| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM-BASIC (FEB 2024)|11|||||||||||| SMALL BUSINESS SUBCONTRACTING PLAN (DOD CONTRACTS)-BASIC (DEV 2026-O0037)(JUL 2026))|2||| WARRANTY OF DATA-BASIC (DEVIATION 2026-O0035) (FEB 2026)|2||| NOTICE OF TOTAL SMALL BUSINESS SET-ASIDE (DEV 2026-O0037)(FEB 2026)|1|| SECURITY PROHIBITIONS AND EXCLUSIONS (CLASS DEVIATION 2026-O0025)(FEB 2026)|7|||||||| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024))|5|||||| BUY AMERICAN-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024)|1|| ALTERNATE A, ANNUAL REPRESENTATIONS AND CERTIFICATIONS (DEVIATION 2026-O0043)(FEB 2026))|13|||||||||||||| NOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY PERPARDENESS, AND ENRGY PROGAM USE (APRIL 2008))|2||X| 1. DD1423 Data Items with title of "INSPECTION AND TEST PLAN" SUB TITLE "INSPECTION SYSTEM PROCEDURES" may be waived if already on file at NAVSUP WSS Mechanicsburg. 2. Portsmouth NSY's DODAAC has changed from N00102 to N50286. Any reference toN00102 within this order should be updated to N50286. 3. The following proposed delivery schedule applies: Submission of Certification Data CDRLs will be on or before 20 days prior to scheduled delivery. PNSY review/acceptance of Certification CDRLs 6 working days after receipt of Certification DD 1423 CDRLs. Final delivery of material will be on or before 137 days after effective date of the resulting contract. 4. Any contract awarded as a result of this solicitation will be "DO" rated order; "DO" rated order certified for national defense use under the Defense Priorities and Allocations System (DPAS). 5. NAVSUP WSS Mechanicsburg will be considering past performance in the evaluation of offers in accordance with DFARS 252.204-7024. 6. If drawings are included in the solicitation, access needs to be requested on the individual solicitation page on Contracts Opportunities on the Government's SAM.gov website. After requesting access, send an email to the Primary POC listed on the solicitation. 7. This order is issued pursuant to Emergency Acquisition Flexibilities (EAF). 8. This is a Level 1 Repair. 9. Please submit: NOT TO EXCEED (NTE) pricing or FIRM FIXED PRICE (FFP). This includes the teardown, evaluation, inspection and full repair of the item to "like new" or "A" condition. See statement of work in solicitation. Please also provide an approximate cost of new item if available. 10. A beyond repair (BR)/ beyond economic repair (BER) price shall also beprovided in addition to the repair price at time submission of quote. 11. Do NOT include the cost for shipping material as the government implemented shipping system or ATAC will be shipping/deliveringmaterial. 12. This contract utilizes Commercial Asset Visibility (CAV). See clause NAVSUPWSSFA25 for further details. \ 1. SCOPE 1.1 The material covered in this contract/purchase order will be used in a crucial shipboard system. The use of incorrect or defective material would create a high probability of failure resulting in serious personnel injury, loss of life, loss of vital shipboard systems, or loss of the ship itself. Therefore, the material has been designated as SPECIAL EMPHASIS material (Level I, Scope of Certification, or Quality Assured) and special control procedures are invoked to ensure receipt of correct material. 2. APPLICABLE DOCUMENTS 2.1 Order of Precedence - In the event of a conflict between the text of this contract/purchase order and the references and/or drawings cited herein, the text of this contract/purchase order must take precedence. Nothing in this contract/purchase order, however, must supersede applicable laws and regulations unless a specific exemption has been obtained. 2.2 Applicable Documents - The document(s) listed below form a part of this contract/purchase order including modifications or exclusions. 2.2.1 Specification Revisions - The specification revisions listed under "Documents References" below are the preferred revision. Older and/or newer r evisions are acceptable when listed within Contract Support Library Reference Number CSD155 in ECDS (Electric Contractor Data Submission) at: ht tps://register.nslc.navy.mil/. This is to allow Contractors to use certain acceptable older specification revisions to purge their existing stock of material certified to those older revisions or to use newer specification revisions when material is certified to newly released revisions,without requiring the submittal of waiver/deviation requests for each specification revision on every contract. Revisions of specifications reflecting editorial and/or re-approval (e.g. E2009, R2014, etc.) are considered inconsequential, but are acceptable when their revisions are listedwithin CSD155 or elsewhere within this contract. 2.2.2 Documents, drawings, and publications supplied are listed under "Drawing Number". These items should be retained until an award is made. 2.2.3 "Document References" listed below must be obtained by the Contractor. Ordering information is included as an attachment to this contract/purchase order. DRAWING DATA=EB-2000 |96169| C|SP |D|0001 | C|49998|0484385 DRAWING DATA=4384676 |53711| C| |D|0001 | C|00026|0000000 DRAWING DATA=7016077 |53711| B| |D|0001 | B|49998|0175546 DRAWING DATA=7016077 |53711| B| |D|0002 | B|49998|0144180 DRAWING DATA=7016077 |53711| B| |D|0003 | B|49998|0157797 DRAWING DATA=7016077 |53711| B| |D|0004 | B|49998|0219730 DRAWING DATA=7016077 |53711| B| |D|0005 | B|49998|0175065 DRAWING DATA=7016077 |53711| B| |D|0005.1 | B|49998|0433181 DRAWING DATA=7016077 |53711| B| |D|0006 | B|49998|0137035 DRAWING DATA=7016077 |53711| B| |D|0007 | B|49998|0114084 DRAWING DATA=7016077 |53711| B| |D|0008 | B|49998|0149567 DRAWING DATA=7016077 |53711| B| |D|0009 | B|49998|0121920 DRAWING DATA=7016077 |53711| B| |D|0010 | B|49998|0169937 DRAWING DATA=7016077 |53711| B| |D|0011 | B|49998|0102221 DRAWING DATA=7016077 |53711| B| |D|0012 | B|49998|0076363 DRAWING DATA=7016077 |53711| B| |D|0013 | B|49998|0130062 DRAWING DATA=7016077 |53711| B| |D|0013.1 | B|49998|0055906 DRAWING DATA=7016077 |53711| B| |D|0014 | B|49998|0110930 DRAWING DATA=7016077 |53711| B| |D|0015 | B|49998|0157569 DRAWING DATA=7016077 |53711| B| |D|0016 | B|49998|0096892 DRAWING DATA=7016077 |53711| B| |D|0017 | B|49998|0105348 DRAWING DATA=7016077 |53711| B| |D|0018 | B|49998|0079948 DRAWING DATA=7016077 |53711| B| |D|0019 | B|49998|0106131 DRAWING DATA=7016077 |53711| B| |D|0020 | B|49998|0071311 DRAWING DATA=7016077 |53711| B| |D|0021 | B|49998|0091132 DRAWING DATA=7016077 |53711| B| |D|0022 | B|49998|0070819 DRAWING DATA=7016077 |53711| B| |D|0023 | B|49998|0110036 DRAWING DATA=7016077 |53711| B| |D|0024 | B|49998|0103251 DRAWING DATA=7016077 |53711| B| |D|0025 | B|49998|0124278 DRAWING DATA=7016077 |53711| B| |D|0026 | B|49998|0100543 DRAWING DATA=7016077 |53711| B| |D|0027 | B|49998|0139517 DRAWING DATA=7016077 |53711| B| |D|0028 | B|49998|0133775 DRAWING DATA=7016077 |53711| B| |D|0029 | B|49998|0092742 DRAWING DATA=7016077 |53711| B| |D|0030 | B|49998|0077445 DRAWING DATA=7016077 |53711| B| |D|0031 | B|49998|0094077 DRAWING DATA=7016077 |53711| B| |D|0032 | B|49998|0067914 DRAWING DATA=7016077 |53711| B| |D|0033 | B|49998|0094440 DRAWING DATA=7016077 |53711| B| |D|0034 | B|49998|0088128 DRAWING DATA=7016077 |53711| B| |D|0035 | B|49998|0078641 DRAWING DATA=7016077 |53711| B| |D|0036 | B|49998|0075186 DRAWING DATA=7016077 |53711| B| |D|0037 | B|49998|0071460 DRAWING DATA=7016077 |53711| B| |D|0038 | B|49998|0068639 DRAWING DATA=7016077 |53711| B| |D|0039 | B|49998|0078106 DRAWING DATA=7016077 |53711| B| |D|0040 | B|49998|0069474 DRAWING DATA=7016077 |53711| B| |D|0041 | B|49998|0077366 DRAWING DATA=7016077 |53711| B| |D|0042 | B|49998|0082080 DRAWING DATA=7016077 |53711| B| |D|0043 | B|49998|0098311 DRAWING DATA=7016077 |53711| B| |D|0044 | B|49998|0063930 DRAWING DATA=7016077 |53711| B| |D|0045 | B|49998|0139043 DRAWING DATA=7016077 |53711| B| |D|0046 | B|49998|0195681 DRAWING DATA=7016077 |53711| B| |D|0047 | B|49998|0112401 DRAWING DATA=7016077 |53711| B| |D|0048 | B|49998|0188714 DRAWING DATA=7016077 |53711| B| |D|0049 | B|49998|0091075 DRAWING DATA=7016077 |53711| B| |D|0050 | B|49998|0108246 DRAWING DATA=7016077 |53711| B| |D|0051 | B|49998|0085364 DRAWING DATA=7016077 |53711| B| |D|0052 | B|49998|0093309 DRAWING DATA=7016077 |53711| B| |D|0053 | B|49998|0101459 DRAWING DATA=7016077 |53711| B| |D|0054 | B|49998|0081213 DRAWING DATA=7016077 |53711| B| |D|0055 | B|49998|0087062 DRAWING DATA=7016077 |53711| B| |D|0056 | B|49998|0082649 DRAWING DATA=7016077 |53711| B| |D|0057 | B|49998|0077652 DRAWING DATA=7016077 |53711| B| |D|0058 | B|49998|0067483 DRAWING DATA=7016077 |53711| B| |D|0059 | B|49998|0085396 DRAWING DATA=7016077 |53711| B| |D|0060 | B|49998|0068904 DRAWING DATA=7016077 |53711|B9|1N |D|0001 |B9|49998|0040107 DRAWING DATA=7016077B147 |53711| A|ER |D|0001 | A|49998|0078803 DRAWING DATA=7016077B147 |53711| A|ER |D|0001.1 | A|49998|0071521 DRAWING DATA=7016077B147 |53711| A|ER |D|0001.2 | A|49998|0076275 DRAWING DATA=7016077B147 |53711| A|ER |D|0001.3 | A|49998|0085170 DRAWING DATA=7016077B147 |53711| A|ER |D|0001.4 | A|49998|0082066 DRAWING DATA=7016077B147 |53711| A|ER |D|0001.5 | A|49998|0026339 DRAWING DATA=7016077B147 |53711| A|ER |D|0001.6 | A|49998|0026274 DRAWING DATA=7016077B147 |53711| A|ER |D|0002 | A|49998|0230472 DRAWING DATA=7016077B165 |53711| A|ER |D|0001 | A|49998|3807537 DRAWING DATA=7016077B66 |53711| B|ER |D|0001 | B|00026|0000000 DOCUMENT REF DATA=FED-STD-H28 | | |B |190424|A| | | DOCUMENT REF DATA=FED-STD-H28 |0020| |B |941221|A| |01| DOCUMENT REF DATA=ANSI/ASQ Z1.4 | | | |080101|A| | | DOCUMENT REF DATA=ASTM-B367 | | | |220401|A| | | DOCUMENT REF DATA=ASTM-B381 | | | |130701|A| | | DOCUMENT REF DATA=MIL-STD-792 | | |F |060519|A| | | DOCUMENT REF DATA=ISO_9001 | | | |081115|A| | | DOCUMENT REF DATA=ISO10012 | | | |030415|A| | | DOCUMENT REF DATA=ISO/IEC 17025 | | | |050515|A| | | DOCUMENT REF DATA=MIL-I-45208 | | |A |810724|A| 1| | DOCUMENT REF DATA=MIL-STD-45662 | | |A |880801|A| | | DOCUMENT REF DATA=ANSI/NCSL Z540.3 | | | |130326|A| | | DOCUMENT REF DATA=0900-LP-001-7000 | | | |810101|C| |01| DOCUMENT REF DATA=S9074-AQ-GIB-010/248 | | |1 |191112|A| | | DOCUMENT REF DATA=T9074-AS-GIB-010/271 | | |1 |140911|A| | | DOCUMENT REF DATA=S9074-AR-GIB-010A/278 (CHG A) | | | |130214|A| | | 3. REQUIREMENTS 3.1 REFURBISHED MATERIAL STATEMENT OF WORK (REPAIR SOW) - 3.1.1 INSPECTION - Clean and determine if refurbishment is possible. At disassembly, the Contractor must record all identifying markings found on the parts of each assembly. The Contractor must maintain traceability of these markings to each unit throughout refurbishment. 3.1.2 IDENTIFYING MARKINGS - Part must have a MIC (Material Identification a and Control) code, heat/heat lot code, or unique Contractor traceability number/code that is visible on the part. See Material Traceability in paragraph 3 (Quality Assurance Provisions) of this contract for traceability requirements. The MIC code can consist of a 2, 3, or 4 letter material identifier, 4 or 5 digit Julian date, 3 digit lot serial number, and Certifying Activity Designator (CAD) which will be 1 or 2 letters; the 4 parts are normally separated by hyphens; examples: TIA-3089-30-QQ and ST-06262-506-A. 3.1.3 RE-USEABLE PARTS - - Any parts of the original assembly that are useable (replacement is not necessary), that are properly marked as identified above, and that have material certifications available may be utilized as initially supplied. Certifications are not required to be resubmitted by the contractor. - Any parts of the original assembly that are useable (replacement is not necessary), are properly marked as identified above, but material certifications are not available at the contractor's facility, a waiver must be submitted in accordance with Waiver/Deviation (Configuration Control) requirements specified elsewhere in the Contract. 3.1.4 NON-USEABLE PARTS - -Any parts of the original assembly that are not properly marked as identified above must be replaced and the required certifications must be submitted. - Any parts of the original assembly that are not usable (replacement is necessary) must be replaced and the required certifications must be submitted. 3.1.5 REFURBISHMENT - Upon completion of inspection, this item must be refurbished to be in accordance with ;Naval Ship Systems Command Drawing 845-7016077, ER7016077B66, ER7016077B147, and ER7016077B165 consisting of one Ball, Item 116 and one each mating Seats, Items 114 and 115; , except as amplified or modified herein. This applies to all "Parts Requiring Certification" as identified elsewhere in this Contract/Purchase Order. 3.1.6 ADDITIONAL SOW REQUIREMENTS - ;Balls which are not usable must be dispositioned and new balls are not to be manufactured under this contract.; 3.2 ;For seats, Items 114 and 115, dimension 1.562 inch nominal must be manufactured to 1.582 +/- 0.005 inch. The stack height requirement of ER7016077B66 does not apply.; 3.3 Material for Parts Requiring Certification - Quantitative chemical and mechanical analysis is required for the parts listed below unless specifically stated otherwise: Part - ;Ball, Item 116; Material - Centrifugally cast 6AL-4V, ASTM-B367, Grade C-5, with mechanical properties as listed in Supplimentary Requirements S6 and S8. ;or ASTM-B381, Grade F-5 with the following modified mechanical properties: Ultimate Tensile Strength - 125,000 psi Minimum (Longitudinal direction) Elongation in 4D - 10% Minimum Yield Strength - 115,000 psi Minimum Reduction of Area Minimum 20%; Part - ;Seats, Items 114 and 115 (Q3); Material - MC903 (Type 6 cast nylon produced with polyepsilon caprolactam by the direct polumerization process) as manufactured by the Polymer Corporation or equal in accordance with Electric Boat Division Specification 2000. (Properties Specified Below Only) ITEM PROPERTY ASTM TEST METHOD VALUE (A) Melting Point D789 221 deg C +/- 9 (430 deg F +/- 16) (B) Relative Viscosity D789 1500-6500 (RV is a unitless value, the RV test specimens must dissolve within a 120 hour period) (C) Specific Gravity D792 1.15 - 1.17 @ 23 deg C (73F) (D) Dimensional Change Note 1 .2% MAX (E) Tensile Impact D1822 80 FT-LB/SQ IN Type S Specimen Minimum Note 3 Note 2 (F) Tensile Yield Stress D638 9,000 PSI MIN Note 2 Note 3 (G) Compressive Strength D695 9,000 PIS MIN 1% Offset Note 2 Note 3 (H) Water Absorption D570 24 HR 1.3% MAX Saturation 7% MAX NOTES: 1. The test method to determine dimensional stability must be performed as follows: The test specimens must be measured at 23 deg C +/- 3 (73 deg F +/- 5) and placed in a mineral oil^ bath maintained 184 deg C +/- 3 (363 deg F +/- 5). The specimens must remain in the bath for six (6) hours at temperature and allowed to slow cool in the bath at a rate not to exceed 23 deg C +/- 3 (41 deg F +/- 5) per hour. When the bath reaches 23 deg C +/- 3 (73 def F +/- 5), the test specimens must be removed and measured. The percent change in each dimension, outside diameter, inside diameter and thickness must not be greater than the value specified. ^Mineral oil meets the specifications as listed below: Description..........................Passes U.S.P. Test (USP XX, P.1143) Solubility...........................Passes U.S.P. Test (USP XX, P.1143) Neutrality...........................Passes U.S.P. Test (USP XX, P.532) Readily Corbonizable Substances......Passes U.S.P. Test (USP XX, P.532) Limit of Polynuclear Compounds.......Passes U.S.P. Test (USP XX, P.532) Solid Parafin........................Passes U.S.P. Test (USP XX, P.532) Specific Gravity @ 25 deg C (77F)....0.8600 to 0.8900 Viscosity @ 37.8 deg C (100 F).......73.6 to 84.4 Centistokes (340-390 SUS) Flash Point Cleveland Open Cup.......420 deg F (216 C) (Typical) Refractive Index @ 20 deg C (68F)....1.480 (Typical) 2. Prior to test specimens must be conditioned as follows: The specimens must be subjected to a temperature of 71 deg C +/- 3 (160 deg F +/- 5) under a vacuum to a maximum of one millimeter absolute pressure until a change of less than .2% between two weighings sixteen (16) hours apart is achieved. 3. These values are minimum averages. Separate specimen values may not vary more than 25% under the specified minimum. 3.4 Testing Certification - Certifications are required for the following tests on the items listed below. Additional testing on other piece parts (if any) per applicable drawings is still required, but certifications are only required as listed below. Test - Non-Destructive Tests Item - ;Weld Repair and/or Production Weld (as applicable); Performance - Per applicable fabrication specification Acceptance - Per applicable fabrication specification 3.5 Alumina-Titania/PTFE coating of Ball(s) must be in accordance with A & A Company Specification Navy016 Rev L. Each Ball manufactured/repaired under this Order must be tagged with a durable non-metallic tag with thefollowing statement: "Ball coated with Alumina-Titania/PTFE coating per A & ACompany, South Plainfield New Jersey, proprietary procedure NAVY016 Rev L. This coating was approved by NAVSEA and these Balls are an approved replacement for the Ball, piece ;2; , of Naval Ship Systems Command Drawing ;845-7016077; ." 3.6 A visual inspection shall be performed on the finished seat with acceptance criteria on critical surfaces per CSD167 in the ECDS (Electronic Contractor Data Submission) system at: https://register.nslc.navy.mil/. 3.7 Ball Spherical Surface Waviness - Unless otherwise specified on drawing, all sealing area surfaces must have a spherical surface waviness which does not exceed 0.0005 inches of height per inch of spherical surface. Roughness and waviness ratings must apply in a direction which yields the maximum rating, normally perpendicular to the lay. 3.8 ;Surface waviness must be verified after Grinding/Finishing of Alumina-Titania coating and before PTFE application. Surface finish of the Alumina-Titania coating, prior to PTFE application must be 32 Microinches.; 3.9 Internal Threads - All internal threads must be formed by cutting. Cold forming of internal threads is not acceptable. 3.10 Thread Inspection Requirements - All threads on threaded parts must be inspected using appropriate inspection methods, inspection systems, and inspection gages/instruments in accordance with FED-STD-H28 series. Substitution of thecommercial equivalent inspection in accordance with ASME B1 series is acceptable. 3.10.1 System 21 of FED-STD-H28/20 must be used as a minimum inspection requirement for threads when the design drawing or design specification does not specify an inspection requirement. 3.10.2 For Navy and Shipyard drawings, system 21 of FED-STD-H28/20 may be substituted for System 22 without further Navy approval when the design drawing invokes System 22 and does not cite governing specifications that specifically require system 22. System 22 of FED-STD-H28/20 must be used when the drawing references other governing specifications that specifically require System 22, such as certain thread types of MIL-DTL-1222. 3.10.3 A written request for concurrence must be submitted when utilizing alternative measuring equipment or measuring systems not applicable to the specified inspection system. 3.11 Welding or Brazing - When welding, brazing, and allied processes are required, as invoked by Section C paragraph 3 requirements, they must be in accordance with S9074-AR-GIB-010A/278, 0900-LP-001-7000 for brazing of piping and pressure vessel applications, or S9074-AQ-GIB-010/248 for brazing of other applications. For all production and repair welding and brazing personnel and procedures must be qualified under S9074-AQ-GIB-010/248 or 0900-LP-001-7000, as applicable. Procedures and Qualification Data must be submitted for review and approval prior to performing any welding or brazing. 3.12 Certificate of Compliance - (SPECIAL EMPHASIS MATERIAL) The Contractor must prepare and submit a certificate of compliance certifying that the items/components furnished under this contract comply with the requirements of the procurement document, including any/all invoked specifications and drawings. 3.13 Configuration Control - The Contractor must maintain the total equipment baseline configuration. For items of proprietary design, Contractor drawings showing the latest assembly configuration must be provided to the Government in electronic (C4) format. Definitions are provided elsewhere in the Contract/Purchase Order. 3.13.1 Waivers/Deviations - All waivers and deviations, regardless of significance or classification require review and approval by the Contracting Officer. Waivers and Deviations must be designated as Critical, Major, or Minor. The Contractor must provide a copy of this request to the QAR. Requests must include the information listed below. a. A complete description of the contract requirement affected and the nature of the waiver/deviation (non-conformance), including a classification of Critical, Major, or Minor. b. Number of units (and serial/lot numbers) to be delivered in this configuration. c. Any impacts to logistics support elements (such as software, manuals, spares, tools, and similar) being utilized by Government personnel or impacts to the operational use of the product. d. Information about remedial action being taken to prevent reoccurrence of the non-conformance. 3.13.2 All requests for Waivers/Deviations on NAVSUP-WSS Contracts must be submitted to the NAVSUP WSS Contracting Specialist via eMail. 3.13.3 ECPs - The Government will maintain configuration control and change authority for all modifications or changes affecting form, fit, function, or interface parameters of the Equipment and its sub-assemblies. The Contractor must submit an Engineering Change Proposal (ECP) for any Class I or II changes that impact the Equipment covered by this contract. ECPs must be prepared in Contractor format, and must include the following information: a. The change priority, change classification (Class I or Class II), and change justification. b. A complete description of the change to be made and the need for that change. c. A complete listing of other Configuration Items impacted by the proposed change and a description of the impact on those CIs. d. Proposed changes to documents controlled by the Government. e. Proposed serial/lot number effectivities of units to be produced in, or retrofitted to, the proposed configuration. f. Recommendations about the way a retrofit should be accomplished. g. Impacts to any logistics support elements (such as software, manuals, spares, tools, and similar) being utilized by Government personnel in support of the product. h. Impacts to the operational use of the product. i. Complete estimated life-cycle cost impact of the proposed change. j. Milestones relating to the processing and implementation of the engineering change. 3.14 Mercury Free - Mercury and mercury containing compounds must not be intentionally added or come in direct contact with hardware or supplies furnished under this contract. Mercury contamination of the material will be cause for rejection. 3.15 NAVSEA 0948-LP-045-7010 - Any applicable requirements of NAVSHIPS 4410.17,NAVSEA 0948-LP-045-7010, or 0948-045-7010 which the contractor must meet are included in this contract/purchase order. The above documents are for GovernmentUse Only. Further application of the above documents is prohibited.prohibited. 3.15.1 Marking of material with a Material Designator per the Drawing is also prohibited, with the exception of Fasteners. Fasteners must be marked with a Material Symbol/Designator as specified elsewhere in this contract. ^ QUALITY ASSURANCE REQUIREMENTS ^ 3.16 See CDRL DI-MISC-80678 (Test Certification) - A statement of tests performed, listing the pieces tested must be furnished along with a copy of the test results. Certification must include the contractor's name, address and date, quantity inspected, identified to the contract/purchase order and item number, and the Contractor's or authorized personnel's signature. Test certifications must reference the standard/specification, including the revision, to which the testing was performed and the acceptance criteria used. Test procedure numbers may also be referenced on test reports. Test reports on weldments must be identified to weld joint and layer. 3.17 Quality System Requirements - The Contractor furnishing items under this contract/purchase order must provide and maintain a quality system in accordance with ISO-9001 as amplified or modified herein, with the calibration system requirements of ISO-10012 or ANSI-Z540.3 with ISO-17025. A Quality System in accordance with MIL-I-45208, with the calibration system requirements of MIL-STD-45662, is acceptable as an alternate. 3.17.1 The Contractor's quality system and products supplied under the system are subject to evaluation, verification inspection, and acceptance/non-acceptance by the Government representative to determine the system's effectiveness in meeting the quality requirements established in the Contract/Purchase Order. 3.17.2 The Contractor's quality system must be documented and must be available for review by the Contracting Officer or his representative prior to initiation of production and throughout the life of the contract. The Prime Contractor must, upon notification, make his facilities available for audit by the contracting Officer or his authorized representative. 3.17.3 See CDRL DI-QCIC-81110 (Inspection System Procedures) - All suppliers of Level I/SUBSAFE (LI/SS) material are required to submit a copy of their current documented quality system procedures to the Procurement Contracting Officer (PCO) prior to award of any contract/purchase order. Suppliers that have a copy of their current quality system procedures on file at the Procuring Activity may request the PCO waive this requirement. 3.17.4 This contract provides for the performance of Government Quality Assurance at source. The place or places of performance may not be changed without the authorization of the Procurement Contracting Officer. Upon receipt of this order, promptly notify the Government representative who normally services your plant so that appropriate planning for Government inspection can be accomplished. If you do not have an assigned Government representative, notify the nearest Defense Contract Management Agency (DCMA) Office. In the event that a local Government representative or DCMA Office cannot be located, our purchasing agent should be notified immediately. 3.17.5 Any changes made by the Contractor to a qualified quality system will require re-submittal to the PCO and concurrence by the Government Quality Assurance Representative prior to adoption. 3.18 Contractor Inspection Requirements - The Contractor must maintain adequate records of all inspections and tests. The records must indicate the nature and number of observations made, the number and type of deficiencies found, the quantities approved and rejected and the nature of corrective action taken as appropriate. Inspection records must be traceable to the material inspected. 3.18.1 The supplier's gages, measuring and test equipment must be made available for use by the Government representative when required to determine conformance with Contract requirements. When conditions warrant, the supplier's personnel must be made available for operations of such devices and for verification of their accuracy and condition. 3.18.2 All documents and reference data applicable to this contract must be available for review by the Government representative. Copies of documents required for Government inspection purposes must be furnished in accordance with the instructions provided by the Government representative. 3.19 Subcontractor Inspection Requirements - The Government has the right to inspect at source, any supplies or services that were not manufactured or performed within the contractor's facility. Such inspection can only be requested by or under authorization of the Government representative. Any purchasing documents to a subcontractor must cite the applicable portions of the contractually invoked quality system (e.g. calibration requirements), plus any product requirements that apply to the supplies being purchased. When the Government elects to perform source inspection at the subcontractor's facility, applicable purchase documents must be annotated with the following statement: "A Government inspection is required prior to shipment from your plant. Upon receipt of this order, promptly notify the Government representative who normally services your plant so that appropriate planning for Government inspection can be accomplished. If you do not have an assigned Government representative, notify the nearest Defense Contract Management Agency (DCMA) Office. In the event that a local Government representative or DCMA Office cannot be located, our purchasing agent should be notified immediately." 3.20 The prime contractor's program must include procedures to assess the capability of the prospective suppliers to produce the products or supply the services in accordance with the contract, prior to the issuance of any purchase document. 3.20.1 Each sub-tier supplier of material or services for items in Section 3 of this contract must be subjected to a periodic review or audit by the Prime to determine the continued capability of the supplier to control the quality of the products or services specified in the purchase order or contract. 3.20.2 The prime contractor must ensure that the purchased product conforms to specified purchase requirements and this contract. The type and extent of control applied to the supplier and the purchased product must be dependent upon the effect of the purchased product on the end item represented by this contract. 3.20.3 The prime contractor must evaluate the requirements of the contract and select suppliers based on their ability to supply the product in accordance with the prime contractor's requirements and the contract. Criteria for selection and evaluation must be established. Records of this effort must be available for review by the government. 3.20.4 The prime contractor's supplier quality assurance program must provide for a review of purchase documents to assure applicable quality requirements are included or referenced in the documentation for compliance by the supplier. 3.21 Government Furnished Material and/or Equipment (GFM/GFE) - When material or equipment is furnished by the Government, the Contractor must develop documented control procedures that require at least the following: 3.21.1 Visual examination upon receipt to detect damage during transit. 3.21.2 Inspection for completeness and proper type. 3.21.3 Verification of material quality received. 3.21.4 Periodic inspection and precautions to assure adequate storage conditions and to guard against damage from handling and deterioration during storage. 3.21.5 Functional testing, either prior to or after installation, or both, as required by the Contract to determine satisfactory operation. 3.21.6 Identification and protection from improper use or disposition. 3.21.7 Reporting to the Government, any GFM or GFE property found damaged, malfunctioning, or otherwise unsuitable for use. In the event of damage or malfunction during or after installation, the supplier must determine and record probable cause and necessity for withholding the material from use. 3.21.8 For GFE material, and as required by the terms of the bailment agreement, the supplier must establish procedures for adequate storage, maintenance, and inspection of bailed Government material. Records of all inspection and maintenance performed on bailed property must be maintained. 3.21.9 Material returned to the contractor must be handled as GFM. 3.22 Traceability and Certification Requirements - To assure that correct materials are installed in Level I/SUBSAFE systems, it is imperative that traceability be maintained from the material to the material certification test report and other required Objective Quality Evidence (OQE). The material certification report must completely and accurately reflect that the material supplied meets the specified requirements. Materials requiring Traceability and Certification Data are identified within Paragraph 3, Section C of this contract/purchase order. 3.22.1 The following provides the minimum requirements for maintaining material traceability and supplements the requirements specified in DI-MISC-81020 and elsewhere in the contract/purchase order. The Contractor must develop written procedures that implement the material control requirements stated herein. 3.23 Material Traceability - The certification data report must be identified through a unique traceability number, heat-lot number, or heat-treat number for metallic material or batch of non-metallic material, as applicable, which must also be marked on the material. This traceability marking on the material must provide direct traceability to the material's chemical composition and mechanical properties certification data. For material produced by batch, continuous cast, or continuous pour processes, samples must be taken no less than once in every eight hours of operation for the purpose of validating proper chemical composition and mechanical properties. Traceability must be maintained through all process operations including any subcontracted operations, to the finished component. 3.23.1 Material Marking for Traceability and Identification - The following are the minimum marking requirements. Additional/alternate marking requirements, if applicable, will be specified elsewhere in the contract/purchase order. In addition to the marking requirements on applicable drawings and/or specifications, marking for traceability is required. All traceability markings must be permanently applied in accordance with MIL-STD-792 (except as specified below). An alternate marking method is permissible provided it is an available option in the contractually invoked specification or drawing, except in instances where the material has been modified by this contract/purchase order and differs from that specified in the specification or drawing. 3.23.2 Traceability markings for items with precision machined or plated surfaces, or material with suitable marking surface areas less than 3/8 inches square (either 3/8" x 3/8" or an area equal to 0.1406 inches square) must be applied to a durable tag and the tag securely affixed to the material. 3.23.3 Permanent marking must be legible and must be located so as to not affect the form, fit, and function of the material. ;The MIC markings and traceability or other identifying marks may be re-marked on top of the Ball near the Stem Hole in a non-working area. Seats to be marked on the outer cylindrical surface.; 3.23.4 Seat Marking - Each seat must be permanently marked in accordance with MIL-STD-792, type I and as stated below, except for Teflon seats, which must only be tagged. Type IX marking may be substituted for type I, provided the minimum character size scribed by the marking tool must be approximately 3/32 inch high to insure legibility. Permanent marking is not permitted on Teflon seats. Seat marking requirements must maintain complete traceability to certification OQE. Seat marking must be either heat/lot or batch number, a vendor traceability number/code, or a combination thereof and must be unique to the material certification. 3.23.5 Traceability markings must be maintained through assembly, and whenever possible must be visible after assembly. For items where the marking is not visible after assembly, a durable tag must be securely attached to the item identifying the part number, piece number, traceability number, and the location of the permanent mark. 3.24 See CDRL-DI-MISC-81020 (Chemical and Mechanical) and CDRL DI-MISC-80678 (SEAT MATERIAL) - Material Certifications - The following material certification requirements apply: 3.24.1 Metallic Material - Quantitative chemical and mechanical analysis of material traceable to traceability markings is required. Material certification test reports must include the class, form, condition, grade, type, finish, and/or composition, as applicable, of the material supplied. 3.24.2 Non-Metallic Material - The Contractor must furnish the applicable test reports for each heat/lot/batch of seat material. Material certification test reports must include, in addition to the specification, the class, form, grade, type, process, and/or composition, as applicable, of the material supplied. 3.24.3 Re-identification and re-certification of metallic material is required when the material is subjected to a process which alters its properties. If the starting material or raw stock is processed in a manner that will not affect its chemical composition or mechanical properties, the original certifications for the chemical composition and mechanical properties, as required by the material specification, are acceptable. Re-certification of the chemical or mechanical properties is required if a process is used during fabrication that alters the original properties of the material (e.g. alloying, heat treating, or forming). In these instances, the properties of the material must be re-determined and documented to reflect the altered condition. The altered material must be uniquely re-identified. The properties thus determined and documented, are required for final certification and must conform to the material specification or the contract/purchase order requirements. When only the mechanical properties are altered, the original certification forchemical composition must be overstamped and annotated with the unique traceability marking used with the altered material and at a minimum contain the information below. TRACEABILITY MARKING________________________________________________ (marking on finished item) IS FABRICATED FROM RAW MATERIAL IDENTIFIED TO HEAT/LOT NUMBER _______________ AND HEAT TREAT NUMBER ______________________ (when applicable) _________________________________________ DATE _____________________ (name and signature of auth. co. rep.) 3.24.4 Material certification data forwarded by the manufacturer must contain a signed certification that the report results represent the actual attributes of the material furnished and indicate full compliance with all applicable specification and contract requirements. Transcription of certification data is prohibited. 3.24.5 Statements on material certification documents must be positive and unqualified. Disclaimers such as "to the best of our knowledge" or "we believe the information contained herein is true" are not acceptable. 3.24.6 If material is received without the required certification papers or with incorrect/missing data on the certification papers, the material will be rejected. 3.25 Material Handling - The written material control process must include the following: 3.25.1 All raw materials must have traceability markings (except as specified below). 3.25.2 Stored raw materials requiring traceability must be segregated to preclude intermingling with materials not requiring traceability. 3.25.3 When traceability markings will be removed by a manufacturing or fabrication process, the marking must be recorded prior to removal and be immediately restored upon completion of the process. If this cannot be done or is impractical, an appropriate material control procedure (such as a bag and tag, tagging, and/or tote box control) must be employed. The material control procedure must provide a method of positive control to preclude commingling of heats/lots or loss of traceability. The traceability marking must be reapplied upon completion of the final manufacturing process. 3.25.4 Brazing or weld filler metals for strength welds forming or integral with pressure containing components or assemblies requiring traceability must be verified to be the correct material, and type or grade, as applicable, prior to consumption. At a minimum, material verification must consist of inspection of material test reports for conformance to specified requirements. Control of welding and brazing filler metals must be maintained to the point of consumption to assure use of the correct type and grade. Markings and traceability requirements do not apply to brazing and weld filler metals after consumption. It is the responsibility of the prime contractor to ensure conformance with the above requirements on welds performed by their subcontractors. 3.25.5 Purchase orders for raw material must specify that the material be traceable to material certification test reports by traceability markings on the material and identified on the test reports. The certification data requirements contained in DI-MISC-81020 must be invoked by the prime contractor on all subcontractors supplying Level I material. 3.25.6 The material control process must include requirements for the maintenance of traceability for items sent out for subcontracted operations. If such operations would remove traceability markings, purchase or work orders must specify a method and marking location for remarking. The contractor must also ensure that subcontractor production controls are adequate to preclude commingling of materials during processing. 3.26 Receiving Inspection 3.26.1 Products and services produced by sub-tier suppliers for incorporation in the contract end item must be subject to inspection or audit at the time of receipt by the prime prior to further processing within the prime contractor's plant or shipment to another location. 3.26.2 Receiving Inspection must include as a minimum - Verification that the traceability marking on the material agrees with that on the certification test reports. Verification that certification test reports are legible and complete. Verification that the contents of the certification test reports are in compliance with the contractually invoked specifications and requirements. 3.27 Discrepancy Reporting 3.27.1 Nonconforming products must be identified and processed in accordance with the prime contractor's procedures for controlling nonconforming products. The prime contractor must report the receipt of any nonconforming products to the responsible sub-tier supplier in accordance with established procedures. Nonconforming material records will be maintained and available for review by the government Quality Assurance Representative (QAR). 3.28 Final Inspection - The following inspections must be performed prior to Government inspection and acceptance. 3.28.1 Material Sampling - Material must be inspected for form, fit, and function. Lot acceptance must be based on zero defects and lot rejection based on one defect. The sample size must be in accordance with the sampling plan(s) in the applicable military specification or standard, federal specification or standard, or drawing to which the material was manufactured. In the absence of such sampling plans, sampling inspection must be per ANSI/ASQ-Z1.4, general inspection level II (for sample size selection code), table IIA (for sample size). SMALL LOT SIZES - For lot sizes of fifty or less, the minimum sample size must be eight units. For lot sizes of eight or less, the sample size must be one hundred percent of the lot. 3.28.2 The Manufacturer may elect to use Statistical Process Control (SPC) to assure product quality in lieu of the above attribute sampling plan, provided that the SPC methodology/system used provides acceptable products to the Government. However, the Government/Navy Receipt Inspection Activity may perform their acceptance inspection of the material using the attribute sampling plan outlined above. 3.28.3 All data concerning material verification (chemical, mechanical or physical properties), traceability (material certifications to material marking), and nondestructive test (NDT) certifications for material must be 100% inspected. The certification test reports must also be 100% inspected for completeness and legibility. 3.28.4 All material requiring traceability must be 100% inspected for traceability marking and that the marking is legible. 3.28.5 Sampling for certification of non-metallic material must be on the basis of one set of test specimens from each heat/lot or batch. 3.29 Quality Statement for the Procurement of Forgings - The forgings must be free of scale and machining burrs. A. All accessible surfaces of the finished forging must be magnetic particle or liquid penetrant inspected (as required by the contract/purchase order) in accordance with T9074-AS-GIB-010/271. Indications obtained by the inspection must be evaluated and must be free of injurious imperfections as defined below: Depth of Injurious Imperfections - Linear imperfections must be explored for depth. When the depth encroaches on the minimum wall thickness of the finished forging, such imperfection must be considered injurious. Any imperfection located in gasket, bearing or machined surfaces which can cause leakage or otherwise interfere with proper function of the component(s). B. Machining or Grinding Imperfections not Classified as Injurious - Surface imperfections not classified as injurious must be treated as follows: Seams, laps, tears or slivers, not deeper than 5 percent of the nominal wall thickness or 1/16 inch (1.6MM), whichever is less. Mechanical marks or abrasions and pits must be acceptable, without grinding or machining, provided the depth does not exceed the limitations set forth in para A above. Imperfections that are deeper than 1/16 inch (1.6MM), but which do not encroach on the minimum wall thickness of the forgings must be removed by grinding to sound metal. When imperfections have been removed by grinding or machining, the outside dimension at the point of grinding or machining may be reduced by the amount removed. Should it be impractical to secure a direct measurement, the wall thickness at the point of grinding or at an imperfection not required to be removed, must be determined by deducting the amount removed by grinding from the nominal finished wall thickness of the forging and the remainder must be not less than the minimum specified or required wall thickness. C. Surface conditions noted in paragraph B above, must be considered acceptable without weld repair provided the grinding is blended smoothly with the adjacent material and is scattered and provided the total ground area does not exceed 10 percent of the forging surface. All ground areas must be reinspected by magnetic particle or liquid penetrant inspections (as required by the contract/purchase order). D. Injurious imperfections and defect excavations which violate the minimum required wall thickness may be weld repaired in accordance with S9074-AR-GIB-010A/278. Authority for the repair of wrought or forged material must be obtained from the Procurement Contracting Officer. This request must be submitted on a DD Form 1694 describing the defect, including size, depth, and location. This request must also include a description of the proposed repair. E. All weld repaired areas must be inspected by magnetic particle or liquid penetrant inspection. Acceptance criteria must be in accordance with S9074-AR-GIB-010A/278. 3.30 Welding Requirements - When production or repair welding is required, the applicable welding procedure(s) and qualification data must be submitted for review and approval. In addition, the CONSUMED WELD METAL C of C as defined below must be submitted as part of the certification OQE package submitted by the Contractor. Note: These requirements do not apply to tack/spot welds. 3.30.1 Approval of the Contractor's qualification data must be obtained prior to performing any welding (production or repair). 3.30.2 If the Contractors qualification data has previously been approved by the Navy for other contracts, a copy of the original approval letter may be submitted along with the procedures and qualification data report to expedite the approval process. The approval letter must reference the applicable welding procedure and qualification data report identification/number. Prior approval does not guarantee acceptance for this or any future contracts. As far as practical, all procedures for the contract must be submitted at the same time. Welding procedures and qualification data must be submitted in a commercially available electronic format such as Adobe Acrobat PDF. The contractor must state the applicability of each weld procedure and qualification data submitted, citing the drawing number and pieces to be welded. (i.e. ''WP-123 and QD-123 are submitted for the weld joint between pieces 1 and 2 on drawing ABC'.' WP-456 and QD-456 are submitted for the hardfacing of piece 3 on drawing XYZ'') 3.30.3 The PCO's authorization for the use of weld procedure(s) and qualification data for the specific application as submitted does not mitigate the vendors responsibility to comply with the requirements of S9074-AQ-GIB-010, S9074-AR-GIB-010A/278,248d the contract. 3.30.4 Authority for the repair of Special Repairs in castings, the repair of wrought material, or the repair of forged material must be obtained via request for waiver from the Procurement Contracting Officer. This request must describe the defect; including size, depth, location, and a description of the proposed repair. Repairs deemed minor or nominal in accordance with S9074-AR-GIB-010/278 can be made at contractor discretion in accordance with S9074-AR-GIB-010/278 requirements; however, Weld Procedure Specification (WPS) and Procedure Qualification Record (PQR) submittals are still required. This request for NAVSUP-WSS Contracts must be submitted via the Electronic Contractor Data Submission (ECDS) application. 3.30.5 Any new procedure qualification performed under this Contract will require the vendor to provide a minimum 72 hour notification to DCMA with an offer to observe the welding of the test assemblies. The 72 hour time limit may be modified upon mutual agreement between the vendor and DCMA. 3.30.6 When drawings require hardfacing surface Iron or Nickel content not to exceed 5%, the contractor must verify surface Iron or Nickel content by performing chemical testing as defined by the applicable drawing. The chemical test results must be submitted as part of the qualification data. 3.30.7 Additional qualification requirements for production hardfacing thickness less than 1/8-inch: Macro-etch (or legible photomacrographs clearly showing the fusion area) must be submitted for review and show consistent, minimized dilution. All essential elements and any elements not listed in S9074-AQ-GIB-010/248 that influence dilution must be in the qualification data and weld procedure, with strict limits placed on each essential element. 3.30.8 Preparation and retention of weld records is required, as specified by paragraph 4.1.3 of S9074-AR-GIB-010A/278. 3.30.9 When production or repair welding is required on titanium materials, theapplicable fabrication plan, facilities procedure, training plan, and active welder qualification must also be submitted for review and approval. 3.30.10 If the contractor's fabrication plan, facilities procedure, training plan, or active welder qualification has previously been approved by the Navy for other contracts, a copy of the original approval letter may be submitted along with the applicable documentation to expedite the approval process. The approval letter must reference the applicable documentation. Prior approval does not guarantee acceptance for this or any future contracts. The contractor's fabrication plan, facilities procedure, training plan, and active welder qualification must be submitted at the same time as the applicable welding procedure(s) and weld procedure qualification data. All documentation must be submitted in a commercially available electronic format, such as Adobe Acrobat PDF. 3.30.11 A Certificate of Compliance is required for all weld filler metals used for production or repair welding, and must include the following: a) Filler Metal LOT number(s) b) Specification and Type c) A positive statement that the vendor has obtained OQE and verified that each LOT of weld filler material conforms to specification requirements. d) A positive statement verifying that the weld filler metals were the correct material type or grade prior to consumption. 3.30.12 When production welds or repair welds are performed by a subcontractor, the requirement for submission of all certification documentation required herein must be passed down to the subcontractor. 3.31 See CDRL DI-MISC-80678 (Special Emphasis C of C) - The certificate of compliance must show traceability to the marking applied on each individual item, and must contain the following information: 1. Contractor's name, address and date. 2. The contract/purchase order number (for example: N00104-11-P-FA12) 3. The National Stock Number (NSN). The 18 character National Stock Number for Special Emphasis Material includes the two digit COG, the four digit FSC, the 9 digit NIIN, and the two digit SMIC (for example: 1H 4820 012345678 L1) ("N/A" when Not Applicable). 4. Lubricants, sealants, anti-seize, and/or thread locking compounds ("N/A" when Not Applicable). 5. Certification that O-rings, packing, gaskets, or other elastomeric products were installed in a compressed state within an assembly or sub-assembly, prior to expiration of the shelf life ("N/A" when Not Applicable). 6. Manufacturer's compound number ("N/A" when Not Applicable). 7. When weld procedure submittal is required by the contract, a statement that the approval date of the qualification data precedes any production or repair welding performed on this Contract. ("N/A" when Not Applicable). 8. A statement to the effect that all items furnished on this contract are in full compliance with the specifications and requirements and list each contractually invoked conformance/compliance test performed by name and that it was performed satisfactorily. 9. Contractor's or authorized personnel's signature. 4. QUALITY ASSURANCE 4.1 Notes to DCMA QAR and the Contractor - 4.1.1 DCMA QAR and the Contractor for proprietary designs - Departures from Contractor imposed requirements, not specifically covered by the contract, must be judged individually on the basis of the effect, if any, on contractual requirements. When there is a disagreement between the Contractor and the Government representative as to the effect on contractual requirements, the departure must be considered a nonconformance and be submitted to the PCO for disposition. 4.1.2 DCMA QAR and the Contractor for proprietary designs - All records of departures from Contractor imposed requirements must be maintained and available for review at the Contractor's facility. A copy must be given to the local Government representative. A record of these departures, traceable to the applicablepart number and contract number must be submitted to the PCO. 4.1.3 DCMA QAR and the Contractor for proprietary designs - For proprietary designs, the contractor's part numbers are acceptable for reference only. The delivered material must conform to all drawings, specifications, and other contractual requirements. 4.1.4 DCMA QAR - It is the responsibility of DCMA QAR to review Non-Destructive Testing (NDT) procedures for NAVSUP Contracts/Purchase Orders. 4.1.5 DCMA QAR and the Contractor - The ECDS (Electronic Contractor Data Submission) system is available for certain data submissions and to submit questions and clarifications, and waiver requests on Contracts and Solicitations. ECDS can be found at: https://register.nslc.navy.mil/ 5. PACKAGING 5.1 Preservation, Packaging, Packing and Marking - Preservation, Packaging, Packing and Marking must be in accordance with the Contract/Purchase Order Schedule and as specified below. MIL-STD 2073 PACKAGING APPLIES AS FOUND ELSEWHERE IN THE SCHEDULE 6. NOTES 6.1 Several definitions of terms that apply to CSI items are listed below. All terms may not apply to every item. 6.1.1 The ECDS (Electronic Contractor Data Submission) system is at: https://register.nslc.navy.mil/ This application will require advance registration using a PKI Digital Certificate on a CAC. A Vendor User Guide is available as CSD001 in the CSD (Contract Support Document) Library within ECDS. 6.1.2 Critical Safety Item (CSI) - Any ship part, assembly, or support equipment containing a critical characteristic whose failure, malfunction, or absence of which could cause a catastrophic or critical failure resulting in loss of, or serious damage to the ship, or unacceptable risk of personal injury or loss of life. 6.1.3 Critical Process - As determined by the TWH, any process, operation or action performed on a Ship CSI that serves to establish a critical characteristic (such as welding, soldering, machining, polishing, cleaning, or assembling) or confirm that a critical characteristic is within drawing or specification compliance (such as, testing, measurement, or non-destructive evaluation). 6.1.4 First Article - Pre-production models, initial product samples, test samples produced to ensure a manufacturer's capability to meet full specification requirements. 6.1.5 First Article Test (FAT) - Contractually required testing and inspection of a supplier's pre-production, production, or "production representative" specimens to evaluate a manufacturer's ability to produce conforming product prior to the Government's commitment to receive subsequent production items. First Article Testing is product specific and does not assess manufacturing process controls nor does it assure the effectiveness of the manufacturer's quality program. 6.1.6 Government Source Inspection (GSI) - GSI is independent oversight performed by a government representative usually a DCMA Quality Assurance Representative (QAR)) to assure that those unique product quality and system elements, identified by the Contracting Agency as important, are observed and evaluated. 6.1.7 Quality Assurance Letter of Instruction (QALI) - A QALI is a formal document initiated by a contracting activity that provides essential requirements and instructions for contracted materials to be independently verified and accepted by a government representative prior to shipment. 6.1.8 Objective Quality Evidence (OQE) - The quantitative and qualitative data of all mechanical, chemical, and performance tests performed (as required by the applicable specification, drawing, or purchase document) to prove that the material supplied conforms to the specified requirements. 6.1.9 Surface Discontinuity - Any surface irregularity, marking, or localized change in physical character of the surface, other than dimensional, that exists infrequently at one or several places. (Examples: burrs, dents, nicks, scratches, gouges, pits, center-punches, scribes, and tool marks) Surface discontinuities less than 0.005-inch in depth are acceptable provided they do not violate any other design requirements specified in this Contract/Purchase Order. 6.1.10 Traceability Code - A code or number providing traceability to the actual chemical and mechanical properties of the specified heat, batch, or form from which the material originated. 6.1.11 Verification - An examination performed to determine compliance with a specific requirement. 6.1.12 Nonconformance - A nonconformance is defined as affecting or violating the followi

Similar Contracts

Same NAICS industry code

NAICS: 332919
New
Federal
VALVE,GLOBE
Solicitation # N0010426QFE70
This contract pertains to the procurement of a 1/4 inch globe needle valve designated as SPECIAL EMPHASIS material (Level I, Quality Assured) for use in a critical shipboard system where failure could result in catastrophic consequences including loss of life or vessel. The valve must fully conform to Swagelok Process Drawing PS-1020, model SS-6NKRSW4P-E4-1103A, with strict material specifications requiring ASTM-A276 or ASTM-A479 UNS S31600 for key components such as the bonnet, union nut, stem assembly, and body. Comprehensive certification and traceability are mandatory, with each assembly requiring a nonferrous metal tag bearing CID number 887075356 and permanent traceability markings linked to chemical and mechanical test reports that must accompany every shipment. All material must be traceable from raw stock through fabrication to final assembly without commingling, and any processing altering properties necessitates re-certification with a new traceability identifier. Testing and quality assurance requirements are rigorous and non-negotiable. Pressure tests must adhere to precise tolerances based on test pressure levels, with durations tightly controlled. Welding and brazing must follow S9074-AQ-GIB-010/248 or 0900-LP-001-7000 standards, requiring prior submission and approval of procedures and qualification data, including WPS and PQR documentation. All welds, especially on titanium or with hardfacing, demand strict oversight, and filler metals require certification with lot numbers and compliance statements. Quality systems must comply with ISO-9001, ISO-10012, and ISO/IEC 17025 or the alternate MIL-I-45208 and MIL-STD-45662, subject to government audit at source. Documentation must be submitted electronically via WAWF to the Portsmouth Naval Shipyard under DODAAC N50286, with inspection and acceptance authority held by N39040, and no material may ship without prior written acceptance. Electronic signatures are accepted as legally equivalent to handwritten, provided they are uniquely controlled and auditable. Final delivery must occur within 365 days of contract effective date, with zero-defect lot acceptance required, and all certifications must be unqualified, positive, and fully traceable to individual items. The contract
Navsup Weapon Systems Support Mech

POSTED

about 3 hours ago

DEADLINE

in 14 days
View Details
NAICS: 332919
New
Federal
RETAINER,SEAT,VALVE
Solicitation # N0010426QFF38
The contract pertains to the procurement of a Retainer, Seat, Valve designated as SPECIAL EMPHASIS Level I material, critical to shipboard systems where failure could result in catastrophic consequences including loss of life or vessel. The item must fully comply with Naval Ship Systems Command Drawing 801-6404739 and adhere to stringent quality and traceability controls. Materials are required to be QQ-N-286, annealed and age-hardened, with mandatory quantitative chemical and mechanical analysis, ultrasonic inspection of starting material, and slow strain rate tensile testing performed exclusively by approved laboratories. All traceability must be maintained from raw material through fabrication to final component via unique heat-lot markings, with electronic and physical records preserving integrity through every process step. Certification documentation must be 100% complete, legible, and signed, with electronic signatures accepted under strict identity verification protocols. No weld repair is permitted on QQ-N-286 material, internal threads must be cut not cold-formed, and mercury is strictly prohibited from contacting any supplied hardware. All deliveries must be preceded by certification data submission via WAWF to Portsmouth Naval Shipyard (N50286) for prior review and acceptance, with notifications sent to PORT_PTNH_WAWF_NOTIFICATION@NAVY.MIL; no material may ship without formal acceptance. The contractor must maintain and document a quality system compliant with ISO-9001 and either ISO-10012 or ANSI-Z540.3 with ISO-17025, or alternatively MIL-I-45208 with MIL-STD-45662, subject to government audit. Thread inspections must follow FED-STD-H28 System 21 or 22 as applicable, and all packaging, preservation, and marking must conform to MIL-STD-2073. Subcontractors must be evaluated, monitored, and their quality controls aligned with prime contractor obligations. Any deviations or waivers require explicit Contracting Officer approval and must be classified as Critical, Major, or Minor. Final acceptance relies on zero-defect lot inspection per ANSI/ASQ Z1.4, with 100% verification of all certifications, traceability markings, and nondestructive test results. The contract is a total small business set-aside, rated under DPAS for national defense priority, and includes mandatory compliance with Buy American Act, Security Prohibitions, and other federal regulations. Delivery must be completed
Navsup Weapon Systems Support Mech

POSTED

about 3 hours ago

DEADLINE

in 3 months
View Details
NAICS: 332919
New
Federal
PARTS KIT,BALL VALV
Solicitation # N0010426QFE42
This contract is a firm fixed-price repair purchase order for a ball valve parts kit designated as Special Emphasis Level I material, critical to shipboard systems where failure could result in catastrophic loss of life, vessel, or mission capability. The contractor must refurbish the valve components to “like new” or “A” condition, including teardown, inspection, and repair, and must provide a beyond-repair price alongside the repair quote. All work must adhere strictly to Newport News Shipbuilding drawings 255583 and 255584, with precise material specifications for the ball (SAE AMS-6931 or ASTM-B367 Grade C-5) and seats (MD71-GG Mearthane, manufactured by Mearthane Products Inc.), including stringent mechanical and chemical property requirements. Traceability is mandatory from raw material through final assembly, requiring permanent marking on components and full certification of chemical composition, mechanical properties, and non-destructive testing, including ultrasonic inspection and surface waviness verification. All certifications must comply with ISO-9001 and either ISO-10012/ISO/IEC 17025 or MIL-I-45208/MIL-STD-45662, with the contractor required to maintain documented quality procedures subject to government audit. Delivery is strictly controlled under a compressed timeline, with final material due no later than 100 days after contract award, and certification data must be submitted via Wide Area Work Flow (WAWF) to Portsmouth Naval Shipyard (DODAAC N50286) for approval prior to any shipment. The government will inspect and accept material at source, and no shipment is permitted without prior written acceptance. The contract mandates 100% inspection of certification documents and traceability markings, with zero-defect acceptance criteria for sampling and strict adherence to MIL-STD-792 for marking, with exceptions for Teflon-coated seats that require tagging. Waivers, deviations, and engineering change proposals require formal government approval and must be submitted through the Electronic Contractor Data Submission system, with critical safety-related changes subject to additional scrutiny. The order is designated as a DO-rated priority for national defense use under the Defense Priorities and Allocations System and issued under Emergency Acquisition Flexibilities. All materials must be mercury-free, and no unapproved substitutions or transcription of certification data is allowed. The contractor must also ensure sub-tier suppliers comply with all traceability, certification,
Navsup Weapon Systems Support Mech

POSTED

about 3 hours ago

DEADLINE

in 28 days
View Details
NAICS: 332919
New
Federal
PARTS KIT,SEDIMENT
Solicitation # N0010426QFB74
This contract pertains to the procurement of a parts kit for sediment control, designated as special emphasis Level I material due to its critical role in a shipboard system where failure could result in catastrophic consequences including loss of life or the ship itself. The material, specifically a stud manufactured to Hellan Strainer Company Drawing 1471 under ASTM-A193 Grade B16, must comply with stringent quality, traceability, and certification requirements. All components require full traceability from raw material through fabrication to final delivery, with unique heat-lot markings permanently applied in accordance with MIL-STD-792 and verified against certified test reports for chemical composition and mechanical properties. Testing must include liquid penetrant or magnetic particle inspection per T9074-AS-GIB-010/271 and MIL-DTL-1222, with 100% inspection of all certification documentation, traceability markings, and nondestructive test results. The contractor must maintain an ISO-9001-compliant quality system with calibration standards aligned to ISO-10012 or ANSI-Z540.3 and ISO-17025, subject to government audit at source. All shipments require prior review and acceptance by Portsmouth Naval Shipyard through the Wide Area WorkFlow (WAWF) system using designated DODAACs N50286 for shipping and N39040 for inspection and acceptance, with electronic notification sent to PORT_PTNH_WAWF_NOTIFICATION@NAVY.MIL. Certification data must be submitted via WAWF no later than 20 days before delivery and cannot be overridden until formal acceptance is granted. No material may be shipped without this pre-shipment approval. The contract mandates full compliance with Buy American provisions, prohibits mercury use, requires defect-free lot acceptance with zero tolerance for nonconformities, and enforces strict configuration control through Engineering Change Proposals for any modifications affecting form, fit, function, or interface. All subcontractors must adhere to the same quality and traceability standards, and any deviations or waivers require formal approval from the Contracting Officer. The delivery timeline is capped at 365 days from the contract’s effective date, and the order is classified as a “DO” rated priority under the Defense Priorities and Allocations System for national defense use.
Navsup Weapon Systems Support Mech

POSTED

about 3 hours ago

DEADLINE

in 14 days
View Details
NAICS: 332919
New
Federal
VALVE ASSEMBLY,MANI
Solicitation # N0010427RNA02
This solicitation, issued by Navsup Weapon Systems Support Mech, is a total small business set-aside for the procurement of a Mani Valve Assembly (NSN 3HD 4820-01-490-9868). The material is designated as Special Emphasis Level I/Subsafe, meaning it is used in crucial shipboard systems where failure could result in catastrophic loss of life or the vessel. Due to this criticality, the contract mandates rigorous quality controls, including a required Quality Assurance Manual for eligibility, adherence to ISO-9001 or MIL-I-45208 standards, and mandatory source inspection and certification by the Level I/DSS SOC Certifying Activity prior to shipment. Technical requirements specify the use of precise materials, such as QQ-N-281 for the valve body and ASTM-B150 for the needle valve, with strict hydrostatic and non-destructive testing protocols. The government will make a single award based on the most advantageous offer, weighing past performance as more important than price. Administrative requirements include electronic invoicing and reporting via Wide Area Workflow (WAWF), compliance with Buy American and cybersecurity regulations, and strict adherence to MIL-STD-129 and MIL-STD-130 for packaging and marking. All deliverables must be mercury-free and include a comprehensive Certificate of Compliance ensuring full traceability.
Navsup Weapon Systems Support Mech

POSTED

about 3 hours ago

DEADLINE

in 24 days
View Details
NAICS: 332919
New
Federal
1VALVE,REGULATING,F
Solicitation # N0010426QFF10
This contract pertains to the procurement of a specialized valve, specifically an Automatic Shutoff Valve, designated as SPECIAL EMPHASIS material (Level I) due to its critical role in shipboard systems where failure could lead to catastrophic outcomes including loss of life or vessel. The material requirements are stringent, mandating strict adherence to specific alloy specifications such as ASTM-B150, QQ-N-281, and SAE AMS-5640, with detailed testing and certification protocols for chemical composition, mechanical properties, and intergranular corrosion resistance. Traceability is paramount: every component must bear a unique traceability marking that links directly to its certification data, and all raw materials must remain segregated and documented from procurement through final assembly to prevent commingling. The contractor must maintain a quality system compliant with ISO-9001 and ISO-10012 or MIL-I-45208 and MIL-STD-45662, subject to government oversight at the source, including mandatory audits and inspections by the Defense Contract Management Agency. All certifications and test reports must be provided in standardized formats and submitted electronically via the Wide Area WorkFlow (WAWF) system, with final acceptance authority vested in Portsmouth Naval Shipyard using DODAAC N50286. Documentation must be complete, unqualified, and physically or electronically signed—no disclaimers are permitted. Welding and brazing procedures require prior approval and adherence to S9074 series standards, with qualification data and filler metal certifications submitted for every production run. The order is classified as a DO-rated national defense priority under the Defense Priorities and Allocations System, and is issued under Emergency Acquisition Flexibilities. Delivery is capped at 365 days post-contract effective date, with certification data must be submitted 20 days prior to each scheduled delivery and approved prior to shipment. The contract enforces Buy American provisions, mandatory small business subcontracting requirements, and a one-year warranty on delivered items, while prohibitions against mercury and improper marking are strictly enforced. Any deviations or waivers require prior written approval from the Contracting Officer and must include full justification and impact analysis, with all changes to configuration managed through formal Engineering Change Proposals.
Navsup Weapon Systems Support Mech

POSTED

about 3 hours ago

DEADLINE

in 7 days
View Details
NAICS: 332919
New
Federal
VALVE,GLOBE
Solicitation # N0010426QFF28
This contract pertains to the procurement of a 2-inch socket weld in-line stop valve with backseat, manufactured in strict compliance with NAVSHIPS drawing 803-2177525, assembly C8A1AF, and is designated as SPECIAL EMPHASIS material due to its critical role in shipboard systems where failure could result in loss of life, vessel damage, or system collapse. All materials, including forged ASTM-A105 or MIL-S-24093 for the body and bonnet, ASTM-A182 Grade F6A or SAE-AMS-QQ-S-763 Class 410 for the stem, and MIL-DTL-1222 for studs and nuts, must meet precise chemical and mechanical requirements, with mandatory certifications for each heat lot. Traceability is enforced from raw material through final assembly via permanent markings and unique traceability numbers, linked directly to chemical and mechanical test reports that must be 100% verified, electronically signed, and unqualified in assertion of compliance. Hydrogen embrittlement relief is required for coated fasteners exceeding specified hardness thresholds, and all internal threads must be cut, not cold-formed. First Article Testing is mandatory, requiring one pre-production unit to be inspected and tested per General Note 7 of Drawing 2177525, with welding procedures and qualification data submitted for approval prior to any production or repair welding performed under S9074-AQ-GIB-010/248 or 0900-LP-001-7000. Certifications must adhere to CDRL requirements, including DI-MISC-80678 for test results, DI-MISC-80875 and DI-MISC-80876 for welding data, and DI-MISC-81020 for material certification, all subject to government inspection at source. The contract mandates ISO-9001 with ISO-10012 and ISO/IEC 17025 compliance, or MIL-I-45208 with MIL-STD-45662 as an alternate, and requires full quality system documentation available for audit. All deliveries are subject to zero-defect lot acceptance criteria using ANSI/ASQ Z1.4 Level II sampling, with material shipments restricted to 365 days after contract effective date. Final delivery is to be supported by electronic submission
Navsup Weapon Systems Support Mech

POSTED

about 3 hours ago

DEADLINE

in 21 days
View Details
NAICS: 332919
New
Federal
REGULATOR,TEMPERATU
Solicitation # N0010423QFC03
This contract pertains to the procurement of a pressure transducer and associated components designated as Special Emphasis Material Level I, critical to shipboard systems where failure could result in catastrophic consequences including loss of life or vessel. The item must conform precisely to Allied Signal drawing 3337765, part number 3337765-1, with strict controls over material composition, welding, heat treatment, and non-destructive testing. The fitting and diaphragm must be fabricated from AMS 5659 alloy and undergo mandatory dye penetrant inspection, proof pressure testing, and electrical validation per specified drawing parameters, with all tests conducted in accordance with MIL-STD-2035 and T9074-AS-GIB-010/271. Traceability is mandatory throughout the supply chain, requiring unique markings on each component linked directly to chemical and mechanical test reports, with batch sampling every eight hours during production. All welds and brazing must comply with S9074-AQ-GIB-010/248 or S9074-AR-GIB-010A/278, requiring prior submission and Navy approval of welding procedures and qualification records, plus submission of consumed weld metal certificates. Strict controls govern material handling, segregation of traceable lots, and prohibitions against cold-formed internal threads or mercury-containing compounds. The contractor must maintain a quality system compliant with ISO-9001, ISO-10012, and ISO/IEC 17025 or alternatively MIL-I-45208 and MIL-STD-45662, subject to government audits and source inspection by DCMA. All documentation, including test certifications, weld records, and material compliance reports, must be submitted electronically through the ECDS system and via WAWF to Portsmouth Naval Shipyard prior to shipment, with specified recipients and notification email for acceptance tracking. The contract mandates 100% inspection of certification data, traceability markings, and non-destructive test results, with zero-defect acceptance criteria for lot sampling. The order is rated for national defense priority under the Defense Priorities and Allocations System, and adherence to Buy American provisions and security restrictions is required. Waivers and deviations must be formally submitted through ECDS, classified as Critical, Major, or Minor, and approved by the Contracting Officer. Engineering Change Proposals are required for any configuration changes affecting form, fit, or
Navsup Weapon Systems Support Mech

POSTED

about 3 hours ago

DEADLINE

in 14 days
View Details
NAICS: 332919
New
Federal
UNION NUT
Solicitation # N0010426QFC62
This contract involves the procurement of a union nut to be used in a critical shipboard system where incorrect or defective material could result in severe consequences including injury, loss of life, or damage to vital equipment or the ship itself. As such, the item is designated as Special Emphasis Material (Level I) with stringent quality and certification requirements. The union nut must conform to Carleton Technology drawing 1970 002 and material specifications under ASTM-B150 alloy C63200, with oxygen cleaning in accordance with MIL-STD-1330. Detailed traceability is required, including unique markings tied to comprehensive material certification data that verify chemical and mechanical properties. Testing certifications, including non-destructive testing for weld repairs, must be submitted and approved before shipment, with all documentation transmitted electronically via Wide Area WorkFlow (WAWF) to the Portsmouth Naval Shipyard for review and acceptance. The contractor is obligated to maintain an ISO-9001 quality system augmented with specific military standards, ensuring rigorous inspection and control throughout fabrication, including welding, brazing, and thread inspection in accordance with FED-STD-H28 or commercial equivalents when authorized. Any deviations or waivers require formal approval, and the government retains configuration control over all modifications through Engineering Change Proposals (ECPs). Government source inspections and audits will be performed, including at subcontractor facilities as applicable. Packaging, preservation, and handling must adhere to MIL-STD 2073. The contract also incorporates prohibitions on mercury contamination and mandates strict compliance with government security and certification protocols, including the acceptance of electronic signatures on certification documents. All material deliveries are subject to zero-defect lot acceptance criteria, with full traceability and quality assurance measures enforced to safeguard critical naval operations.
Navsup Weapon Systems Support Mech

POSTED

about 3 hours ago

DEADLINE

in 14 days
View Details

More opportunities from Department Of Defense → Navsup Weapon Systems Support Mech

Same awarding agency

NAICS: 333998
New
Federal
36--CANISTER
Solicitation # N0010426QFG27
This contract pertains to the procurement of a specialized CANISTER designed for use in a critical shipboard system, where any failure could result in catastrophic consequences including loss of life, ship damage, or system failure. The item is classified as SPECIAL EMPHASIS MATERIAL (Level I) and is subject to stringent quality control, traceability, and inspection protocols under the Deep Submergence Systems Program. The contractor must comply with ISO-9001 or equivalent quality systems, maintain traceability from raw material to finished product using MIL-STD-792-compliant markings, and ensure 100% inspection of all Objective Quality Evidence and certification documents. All materials must conform to NAVSEA SS521-AM-MMA-010 Chapter 7, Navy part number 3.80.1018-3, and meet strict toxicity and flammability standards per NAVSEA SS800-AG-MAN-010/P-9290. Mercury and mercury-containing compounds are prohibited, and configuration control is strictly enforced through Engineering Change Proposals for any modifications affecting form, fit, function, or interface. The contract mandates zero-defect acceptance criteria for lot inspections, with sampling governed by ANSI/ASQ Z1.4 or full lot inspection for small batches. All compliance documentation, including Certificates of Compliance, must be submitted electronically via Wide Area Work Flow prior to delivery and must contain precise traceability to individual units, NSNs, and material certifications with no disclaimers or ambiguities. Certification data must be reviewed and accepted by Portsmouth Naval Shipyard six working days before final delivery, which is due within 210 days of contract award. Subcontractors are bound by the same quality requirements and must be notified of required Government inspections. The contractor must provide records of all inspections, calibrations, and nonconformances, and any waivers or deviations require prior written approval from the Contracting Officer with classification as Critical, Major, or Minor. Government Source Inspection by DCMA is mandatory at the contractor’s facility, and all packaging must conform to MIL-STD-2073. The contract further enforces Buy American provisions, Small Business Set-Aside status, and strict security restrictions in accordance with recent DOD deviations. All documentation submissions, including waiver requests and quality system procedures, must be processed via the Electronic Contractor Data Submission system, requiring PKI/CAC authentication. Final shipment is prohibited until formal acceptance is granted through WAWF with designated inspection and
All Other Miscellaneous General Purpose Machinery Manufacturing

POSTED

about 3 hours ago

DEADLINE

in about 1 month
View Details
NAICS: 332618
New
Federal
53--KEY
Solicitation # N0010426QFF94
This contract, issued under solicitation number N0010426QFF94 by the Naval Supply Systems Command Weapon Systems Support in Mechanicsburg, Pennsylvania, is for the procurement of a critical shipboard component known as the Key (KARON Block), designated as SPECIAL EMPHASIS Level I material due to its direct impact on the safety and operational integrity of naval vessels. The item must be manufactured strictly in accordance with Kamatics Drawing KPD4544 and comply with stringent quality, traceability, and certification requirements. All materials must be mercury-free, and non-metallic components must meet NAVSEA SS800-AG-MAN-010/P-9290 toxicity and flammability standards. The contract mandates full traceability from raw material through final assembly, requiring permanent markings on the product and corresponding Objective Quality Evidence (OQE) linked to each unit, with controls to prevent commingling or loss of traceability during subcontracted processes. The contractor must maintain a certified quality management system compliant with ISO-9001, ISO-10012, and ISO/IEC 17025, or alternatively MIL-I-45208 and MIL-STD-45662, subject to government audit at any time. Inspection and acceptance are governed by zero-defect sampling standards, with 100% review of all certification documents, test reports, and traceability records. A detailed Certificate of Compliance is required for each shipment, including specific certifications for lubricants, weld procedures, and HM&E testing, signed by authorized personnel. All waivers, deviations, and engineering change proposals must be formally submitted and approved by the Contracting Officer prior to implementation and annotated in WAWF with designated ship-to and inspect-by codes. Delivery schedules require certification data submission 20 days prior to shipment, with final acceptance only granted after Portsmouth Naval Shipyard review and explicit approval via WAWF. The contract enforces Buy American and Federal Trade Agreement compliance, prohibits unauthorized distribution of technical data, and retains government authority to perform source inspection at any point in the supply chain, including subcontractor facilities.
Other Fabricated Wire Product Manufacturing

POSTED

about 3 hours ago

DEADLINE

in about 1 month
View Details
NAICS: 335311
New
Federal
61--CABLE ASSEMBLY,SPEC- AND SIMILAR REPLACEMENT PARTS
Solicitation # N0010426QFF21
Solicitation NO0104-26-Q-FF21 is a combined fixed-price request for quotations issued by NAVSUP Weapon Systems Support Mechanicsburg for the manufacture of multiple specialized cable assemblies, including NIIN 015433620. These items are designated as Special Emphasis material (Level I, Scope of Certification) because they are used in crucial shipboard systems where failure could result in serious personnel injury or loss of the vessel. Due to this criticality, the contract mandates strict adherence to quality standards, including ISO-9001, ISO-10012, and ISO/IEC 17025, and requires a one-year warranty. The government may make multiple awards at the CLIN level, with evaluation prioritizing past performance over price. Technical requirements include compliance with NAVSEA SS800-AG-MAN-010/P-9290 for toxicity and flammability, as well as specific hydrostatic pressure, insulation resistance, and dielectric testing. The delivery schedule specifies a final material delivery window of 400 days, with staggered deadlines for weld procedure data, First Article Test reports, and certification CDRLs. All shipments are FOB Destination and must follow MIL-STD-2073-1 for packaging and MIL-STD-129 for marking. Offerors must submit a Quality Assurance Manual to be eligible for award, and the deadline for receipt of offers has been extended to 4:30 PM EST on October 23, 2026.
Power, Distribution, and Specialty Transformer Manufacturing

POSTED

about 3 hours ago

DEADLINE

in about 1 month
View Details
NAICS: 335931
New
Federal
59--CONNECTOR,ELECTRIC
Solicitation # N0010426RFE40
Solicitation N00104-26-R-FE40, issued by NAVSUP Weapon Systems Support Mechanicsburg, is for the procurement of Electrical Connector Assemblies (NSN 1H-5995-01-481-6257). These components are designated as Special Emphasis material (Level I) because they are used in crucial shipboard systems where failure could result in serious personnel injury or loss of the vessel. The requirement includes the manufacture of 40 units for delivery to Portsmouth Naval Shipyard, with a final delivery deadline of 365 days after the effective date of the resulting contract. The order is designated as a DO-rated order for national defense use under the Defense Priorities and Allocations System. The contract mandates rigorous quality assurance and testing protocols, including both contractor and government First Article Testing (FAT). Technical requirements specify compliance with MIL-DTL-24231 and ISO-9001 quality systems, with strict mandates for quantitative chemical and mechanical analysis, dye penetrant inspection, and ultrasonic inspection on specific parts. All materials must maintain full traceability to original heat/lot numbers. Award will be made to a single responsible offeror based on the most advantageous combination of price and past performance, with past performance weighted as more important than price. Invoicing and receiving reports must be processed electronically through the Wide Area Workflow system.
Current-Carrying Wiring Device Manufacturing

POSTED

about 3 hours ago

DEADLINE

in 14 days
View Details
NAICS: 335313
New
Federal
SWITCH,PROXIMITY
Solicitation # N0010426QQB91
Solicitation N0010426QQB91, issued by NAVSUP Weapon Systems Support Mechanicsburg, is a fixed-price request for quotations for the teardown, evaluation, and repair of Proximity Switches (NSN 5930-01-354-4383). The contractor must ensure repaired items meet the operational and functional requirements associated with CAGE Code 53711 and Reference Number 6570535, performing all work according to original manufacturer specifications and drawings. A critical performance metric is the Repair Turnaround Time (RTAT) of 430 days, measured from the physical receipt of the asset to the date of acceptance. Award will be granted to the responsible offeror submitting the lowest priced technically acceptable offer, with evaluations incorporating Supplier Performance Risk System (SPRS) assessments regarding item, price, and supplier risk. The contract mandates strict adherence to quality and technical standards, including physical identification per MIL-STD-130, electrostatic discharge control per ANSI/ESD S20.20, and packaging according to MIL-STD-2073. Inspection and acceptance are conducted at the origin, and Government Source Inspection (GSI) is required. Contractors must maintain all inspection records for 365 calendar days following final delivery. Administrative requirements include the use of Wide Area Workflow (WAWF) for invoicing and compliance with DFARS 252.204-7012 for safeguarding covered defense information. Offerors must provide proof of being an authorized distributor of the original manufacturer's item to be considered for award.
Switchgear and Switchboard Apparatus Manufacturing

POSTED

about 3 hours ago

DEADLINE

in 14 days
View Details
NAICS: 332722
New
Federal
NUT,PLAIN,HEXAGON
Solicitation # N0010426QFF19
This contract pertains to the procurement of hexagon nuts designated as SPECIAL EMPHASIS Level I material for use in critical shipboard systems, where failure could lead to catastrophic outcomes including loss of life or vessel. The nuts must conform to York drawing 366-59531 and be manufactured from QQ-N-286 material in annealed and age-hardened condition, with stringent requirements for traceability, chemical and mechanical testing, and nondestructive inspection. Each shipment must include an additional fastener per heat/lot with full traceability, and all materials must be marked permanently using approved methods per MIL-DTL-1222 and MIL-STD-792, ensuring identification of manufacturer, material symbol, and unique heat-lot traceability. All certification data must be submitted via WAWF to Portsmouth Naval Shipyard (N50286) prior to shipment, approved by N39040, and accompanied by electronic notification to PORT_PTNH_WAWF_NOTIFICATION@NAVY.MIL, with no material allowed to ship without prior acceptance. The contract mandates adherence to ISO-9001 or MIL-I-45208 quality systems, with Government Quality Assurance at source, including inspections by DCMA and review of all test reports, which must be positive, unqualified, and directly tied to traceable marking on the material. Testing must be performed by approved labs for critical procedures like Slow Strain Rate Tensile Tests, and chemical and mechanical certifications must reflect actual properties post-fabrication, prohibiting transcription or ambiguous language. Internal threads must be cut, not cold-formed; threads must be inspected per FED-STD-H28, with System 21 as minimum unless otherwise specified. Mercury is strictly prohibited, and all packaging and handling must follow MIL-STD-2073. Delivery is capped at 365 days post-effective date, early delivery is permitted without cost, and the order is classified as DX/DO rated under DPAS for national defense priority. All subcontracting, waivers, and deviations require formal approval, and failure to comply with any requirement—including missing, incomplete, or improperly formatted certifications—will result in rejection of materials.
Bolt, Nut, Screw, Rivet, and Washer Manufacturing

POSTED

about 3 hours ago

DEADLINE

in 14 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS