Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on February 27, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Barren River Lake Bulkhead and Cylinder Painting

Closed
W912QR24Q0011Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238320
New
SLED
Central Park Splash Pad Painting And Sealing
Solicitation # 20261019052
The City of Rancho Santa Margarita is soliciting sealed bids for the Central Park Splash Pad Painting and Sealing project, with a City Engineer's estimate of 25,000 dollars. The scope of work includes public works construction focused on refreshing the splash pad area through mobilization, surface preparation, painting, sealing, staining, and other miscellaneous improvements. The contract will be awarded to the lowest responsive responsible bidder who possesses a valid Class A General Engineering, Class B Building Contractor, or applicable Class C Contractor's License. Bids must be submitted to the Office of the City Engineer by 10:30 a.m. on November 10, 2026. The project is subject to California Department of Industrial Relations prevailing wage rates and requires contractors to be registered with the DIR. Following the bid opening, the successful bidder must adhere to a strict submission timeline: a revised bid bond within three business days, the contract agreement and insurance within five working days of the Notice of Apparent Low Bidder, and faithful performance and material and labor bonds, a construction schedule, and a water pollution control plan within ten working days of the Notice of Award. Financial terms include a five percent retention on all payments, with final release authorized thirty-five days after the recordation of the Notice of Completion.
CITY OF RANCHO SANTA MARGARITA

POSTED

about 18 hours ago

DEADLINE

in 21 days

General Info

NAICS

238320 - Painting and Wall Covering Contractors

Place of Performance

Glasgow, KY, 42141, USA

Set-Aside

SBA

Documents

5

Solicitation W912QR24Q0011 - Bulkhead Painting at Barren River Lake

PDF, High priority: read this firstifb
High

W912QR24Q0011 Amendment 0001

PDF, High priority: read this first2 pages · amendment
High

W912QR24Q0011 Amendment 0002

PDF, High priority: read this first2 pages · amendment
High

W912QR24Q0011 Amendment 0003

PDF, High priority: read this first3 pages · amendment
High

W912QR24Q0011 Amendment 0004 - Barren River Lake Bulkhead and Cylinder Painting

PDF, High priority: read this first2 pages · amendment
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

5 updates
PhaseClosed
Posted

Combined Synopsis

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Notice updated

Response deadline changed from Jan 17, 2024 to Jan 23, 2024. The notice description changed.

Notice updated

Response deadline changed from Jan 23, 2024 to Jan 26, 2024. The notice description changed.

Response Deadline

Deadline has passed

Notice updated

Notice details unchanged. Attachments may have changed.

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W072 Endist Louisville
Contacts2 people available
OfficeLOUISVILLE, KY, 40202-2230, USA
Office AddressLOUISVILLE, KY, 40202-2230, USA

Full Description

Show more
This scope of work includes surface prep, debris containment and disposal, and painting of one (1) Maintenance Bulkhead, one (1) Bulkhead Door, four (4) Multilevel Cylinders, two (2) Bypass Cylinders, and three (3) Main Gate Cylinders and their respective baseplates, and other bypass platform appurtenances as indicated in this contract. Prices shall include mobilization & de-mobilization, fuel, labor, material, equipment, disposal, and any and all applicable permits to prep and paint the above listed components at Barren River Lake. ***Solicitation amended to include*** Information regarding the U.S. Army Corps of Engineers process for settling requests for equitable adjustments and duration goals to achieve definitization of equitable adjustments for change orders under construction contracts can be found by going to https://www.usace.army.mil/Business-With-Us/Partnering/ then clicking on - View FFP Contract Changes Playbook Here. Any additional questions from the solicitation must be received by 17 January 2024 to be accepted and answered by the government. All quotes must acknowledge all amendments to be an acceptable quote. The offeror due date is hereby extended to 26 January 2024 at 11:00 AM ET. ***Clarification about Exhibit E in the solicitation*** For clarification purposes, items listed in Exhibit E (Lead-Based Paint (LBP) Chip Sampling Reports) that tested positive for lead on the analysis report from Schneider Laboratories order #526706 ARE NOT included in the scope of work beginning on page 5 of solicitation W912QR24Q0011. The items listed below in order#526706 were found to include lead and therefore were intentionally removed from the scope of work for this solicitation. Customer sample ID #3 - Multi-Level Entry Door is a hinged rectangular door on the bypass platform that allows access to the multi-level well. This item is not represented in any line item of the solicitation and was not represented in the site visit. Customer Sample ID #6 - Emergency Bulkhead is mislabeled in the report. This item should be known as - Emergency Gate and is located inside the control tower. This item is not represented in any line item of the solicitation and was not represented in the site visit. To further reduce confusion, Contractors shall refer to Schneider Laboratories order #515930, for an item that IS included in the scope of work that was mislabeled, but did not test positive for the presence of lead. Customer sample ID #3 - Emergency Bulk Head. This Item is mislabeled on order #515930 and should be known as - Maintenance Bulkhead. This is the same item that is represented as - Line Item 001: Blast and Paint Maintenance Bulkhead on page 5 of the solicitation and was displayed for contractors analysis during the site visit. ***Questions answered about the solicitation*** Q: The Solicitation does not contain specific instructions on quote submission. Is pricing on the SF1442 the only item required for submission? Please confirm. A: Please submit all quote submissions to justin.m.mcpherson@usace.army.mil by completing both the SF1442 and the Price Breakout Schedule found on page 4 of the solicitation. Q: I need to know if there are any pictures of the Maintenance Bulkhead, Bulkhead Door and Cylinders that can be viewed. Will the area be dry for work or will the contractor be responsible for site preparations before work begin. If no photos are available can measurements be given of the maintenance bulkhead, bulkhead door and cylinder's so the work perspective can be evaluated appropriately since I will not be visiting the worksite before bidding. A: Please refer to the attachment Solicitation W912QR24Q0011.pdf on the SAM.gov posting for answers to your questions. Please refer to the Scope of Work, beginning on page 5 of that attachment, that includes approximate measurements. Offerors should attend the site visit (10 JAN 2024 @ 10 AM CT) to obtain precise measurements. Please refer to Exhibit F, Project Photos and Drawings, beginning on page 45 of the attachment for all pictures of the work needed on the bulkhead and cylinders for this solicitation. Q: I had a quick question concerning the EPA Lead Certification needed. The 8hr "Lead Renovator Certification" course that is offered through Zack Academy is it sufficient it is an accredited course. A: The Certification needs to meet the requirements of the EPA. A good place to start is here: https://www.epa.gov/lead/renovation-repair-and-painting-program-renovator-training That website lists training requirements as well as training providers in various localities. Q: We provided a proposal when this project bid last year. Can you tell me why the bid was canceled? Also has anything in this solicitation changed form the initial? A: Good afternoon. I was not on this project last year. Because of that I am unsure why it didn't move forward before or if there have been any changes on this solicitation. However, we hope you are interested in this solicitation and we will look forward to receiving your quote. Q: Just wanted to confirm that (3) weeks is the anticipated time to be required for USACE inspection of the bulkhead gate? A: See Line Item 001, section - e Q: Please confirm that the bulkhead gate will require an initial pre blast prior to inspection, and a re-blast after inspection has been completed. A: See Line Item 001, section - e Q: Will the USACE require any certifications or test panels of the coating applicators? A: See section 8 - Permits and Licenses Q: What level or class of containment is required for the abrasive blasting surface preparation of the project? A: See section 10 - Containment and Respiratory Plans Q: Can the contractor anchor into the control tower for supporting of erected structures and containment? Anchor points will be patched after completion of the project. A: Proposed anchor points must be submitted by drawing and approved by USACE before installation. Q: Will USACE require full time onsite SSHO, QCM, or any other safety oversight for the project? A: See EM385 1-1 (01.A.17) Q: Will there be any UFGS specifications to be adhered to on this project? A: Contractor shall conform to specifications as outlined in this solicitation as well as any and all other applicable publications; see Section 31, - Applicable Publications Q: In the solicitation, the paint chip lead testing seems to only be focused on areas not included in this project (i.e. control tower walls, floors, and bridge). At the site visit, it visually appeared the items we are being asked to quote contained lead-based paint primer. Please advise how to proceed with bidding this project. A: The lead based paint chip sampling report included in this solicitation ( Schneider laboratories order # 526706, 515930 ) includes the components specifically identified within each line item. Results of each item tested are outlined in the report. Q: Will SSPC QP-1/QP-2/QS-1 be required of the surface preparation and painting contractor? A: SSPC QP-1 is sufficient. Q: Will 10hr workdays and Saturday work be allowed for this project? A: See - working hours in section 5 of the Solicitation.

More opportunities from Department Of Defense → W072 Endist Louisville

Same awarding agency

NAICS: 236220
New
Federal
Design-Build Maintenance and Repair Army Reserve (MRAR) of Equipment Concentration Site (ECS), B-56767, at North Fort Hood, TX
Solicitation # W912QR25RA013
Solicitation No. W912QR25RA013 is a two-phase Design-Build procurement issued by the U.S. Army Corps of Engineers, Louisville District, for the repair and expansion of the Equipment Concentration Site (ECS), Building 56767, at North Fort Cavazos, Texas. This total small business set-aside project involves renovating approximately 26,000 square feet of a failing maintenance facility. The scope of work includes repairing HVAC and electrical systems, replacing the roof and insulation, restoring non-code compliant bathrooms and showers, and removing non-structural interior walls to create flexible workspaces. Additionally, the project requires the installation of ABA-compliant entrance and curb ramps, the implementation of a code-compliant fire alarm and suppression system—specifically requiring Monaco Enterprises Incorporated equipment for network compatibility—and ensuring the facility meets minimum DOD Antiterrorism standards. The contract is a Firm-Fixed-Price award with an estimated construction magnitude between $10,000,000 and $25,000,000, funded by FY25 Operations and Maintenance Army Reserves funds. The estimated duration of performance is 913 calendar days from the Notice to Proceed. Selection is based on a Best-Value Tradeoff process, where Phase I evaluates technical approach and past performance to select five qualified offerors for Phase II. Phase II evaluation focuses on the design narrative, management plan, schedule narrative, and price. Award is subject to the availability of funds and requires offerors to maintain active registration in the System for Award Management and comply with NIST SP 800-171 cybersecurity standards.
Commercial and Institutional Building Construction

POSTED

1 day ago

DEADLINE

in about 1 month
View Details
NAICS: 236220
New
Federal
Small Business D/B Military Construction MATOC
Solicitation # W912QR25R0018
The U.S. Army Corps of Engineers Louisville District is soliciting proposals for an Indefinite-Delivery, Indefinite-Quantity Multiple-Award Task Order Contract (MATOC) for design-build and design-bid-build construction and renovation projects. This 100% Total Small Business Set-Aside under NAICS 236220 supports military construction and operations and maintenance requirements across Michigan, Illinois, Indiana, Ohio, and Kentucky. The contract has a total capacity not to exceed 240 million dollars, with a target of seven firm-fixed-price awards. Each contract includes a five-year ordering period with a possible six-month extension, though no additional capacity is added if the option is exercised. Sample project magnitudes are anticipated to be between 5 million and 10 million dollars, with a maximum task order limit of 15 million dollars. The procurement follows a two-phase selection process using a Best Value Trade-Off approach. Phase I evaluates offerors based on Past Performance and Technical Approach to down-select a target of ten highly qualified firms for Phase II. In Phase II, proposals are evaluated on Design/Technical factors, Management Approach, and Price, with non-price factors combined being approximately equal to price. Offerors must maintain active registration in the System for Award Management and provide a licensed Designer of Record. Key requirements include the submission of a Contractor Construction Quality Control Plan within 30 days of notice to proceed and adherence to the Louisville District Military Design Guide and various technical standards including ASHRAE and EPACT.
Commercial and Institutional Building Construction

POSTED

6 days ago

DEADLINE

in 23 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS