Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Defense was posted on September 15, 2016. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

BLDG 801 - A-1 INVESTIGATIVE

Closed
F7R3136215AW01Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541330
New
SLED
Road Asset Management
Solicitation # FY27-ENGCP-002-6
The Bulloch County Board of Commissioners is soliciting Statements of Qualifications for project FY27-ENGCP-002-6, focused on Road Asset Management. The selected consultant will be responsible for collecting and analyzing field data, creating a road asset inventory, and developing a Capital Improvement Plan with an outlook extending to FY 35. The scope includes GIS database development, web-based mapping, and the identification of structural hazards and drainage failures to minimize safety risks and legal liability. All prime and sub-consultants must be GDOT Prequalified Contractors as of the submission deadline on November 20, 2026, at 3:00 PM EDT. Proposals are evaluated based on a composite scoring system that weights prime consultant experience and technical approach at 20% each, GIS capabilities at 20%, asset prioritization methodology at 15%, workload capacity at 15%, and past references at 10%. The highest-ranked consultant will be invited to negotiate a contract. Key requirements include a Principal-in-Charge with at least 10 years of industry experience and comprehensive insurance coverage, including professional malpractice and general liability of at least 1 million dollars per occurrence. Submissions are limited to ten pages, excluding mandatory forms and charts, and must include a Non-Collusion Affidavit and Bidder Declaration. Either party may terminate the resulting agreement with 30 days written notice.
Bulloch County Board of Commissioners

POSTED

about 16 hours ago

DEADLINE

in 21 days

General Info

NAICS

541330 - Engineering Services

Place of Performance

179TH AIRLIFT WING, OHIO AIR NATIONAL GUARD 1947 HARRINGTON MEMORIAL RD, MANSFIELD, OH, 44903-8049, USA

Set-Aside

8A

Documents

1

RFI_template_-_Bldg_801.doc

DOC

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

special-notice

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W7NU Uspfo Activity Ohang 179
Contacts1 person available
OfficeMANSFIELD, OH, 44903-8049, USA
Office AddressMANSFIELD, OH, 44903-8049, USA
Contacts
GORDON STROMCONTRACTING OFFICER

Full Description

Show more
ARCHITECT ENGINEER (A-E) CONTRACT FOR THE NATIONAL GUARD IN SUPPORT OF THE AIR AND ARMY NATIONAL GUARD PROGRAMS THROUGHOUT THE US AND ITS TERRITORIES. CONTRACT INFORMATION: The National Guard Bureau is soliciting for Non-Personal Architect-Engineer (A-E) Services in accordance with Public Law 92-582 (Brooks Act) and Federal Acquisition Regulation (FAR) Part 36. This announcement is posted in accordance with FAR 5.205(f). This requirement is set-aside for qualified 8(a) companies within Small Business Administration (SBA) Columbus, Ohio District - 0593, in accordance with FAR 19.804-2(c). All qualified companies shall be identified by the SBA district office. The North American Industry Classification System (NAICS) code for this action is 541330. The Small Business size standard is $38.5. 8(a) companies are encouraged to team with other Small businesses where possible. The 179th AW intends to award a single firm fixed price contract for this requirement. Selection of A-E firms is not based upon competitive bidding procedures, but rather upon the professional qualifications necessary for the performance of the required services. All A-E firms are cautioned to review the restrictions of FAR 9.5 Organizational and Consultant Conflicts of Interest and 36.209 Construction Contracts with Architect-Engineer Firms. All interested Architect-Engineers are reminded that, in accordance with the provisions of PL 95-507, they will be expected to place subcontracts to the maximum practicable extent consistent with the efficient performance of the contract with small and small disadvantaged firms. PROJECT INFORMATION: ***ONLY TYPE A-1 SERVICES ARE BEING REQUIRED FOR THIS PROJECT*** A-E Services shall provide services in accordance with ANGETL 10-03, ANG Design Objectives and Procedures (Tab C) and any/all applicable standards, to include but not limited to; Presidential Orders, Congressional Mandates, UFCs, DoD Directives, Air Force Instructions and Engineering Technical Letters (ETLs). Services shall include, but not be limited to, preparation of a basis of design, concept proposal and development, generation of multiple alternative concepts, development of construction contract documents (to include plans, specifications, calculations, cost estimates, cost management plans, quality control and assurance plans, drawings, and associated details), and construction inspection and testing services. The services are for the investigation and repair of the roofing system at Building 801 for the 179 Airlift Wing in Mansfield, Ohio. Additionally, task orders may be issued for support services which require A-E Services as defined in FAR 2.101. SITE SPECIFIC CRITERIA: The 179th Airlift Wing (179AW) and 200th RED HORSE, Detachment 1 requires a facility to provide training in support of home station and contingency training. Building 801 was constructed in 2010 and completed in 2011. The existing roofing is constructed of a metal roof system. Evidence of leaking has been identified and recorded around areas of the facility. SELECTION CRITERIA: Authority: Air National Guard (ANG) Engineering Technical Letter (ETL) 15-04, Architect-Engineer Selection Process, Attachment 1, Paragraph 4: Criterial for A-E Evaluation, et seq. The selection criteria are listed below in descending order of importance (first by major criterion and then by each sub-criterion). - 1. Criteria A: Past Performance based on established CPARS ratings, personal knowledge and other credible information included on SF 330 - a. Government Agencies & Private Industries - b. Cost Control; - c. Quality of Work; - d. Complexity of Work; - e. Performance Schedule; - f. Customer Satisfaction. - 2. Criteria B: Professional Qualifications - Qualifications deemed necessary for satisfactory performance of required services. The selected firm must have, either in-house or through consultants, the following disciplines, with registration required, where applicable. This factor evaluates the experience of persons on the team in each of the architectural and engineering disciplines required to accomplish the project, with appropriate registration by the State of Ohio where applicable: - a. Architect; - b. Structural Engineer; - c. Interior Designer; - i. Registered Architect with specialized experience; - ii. Registered Interior Designer, and/or; - iii. NCIDQ Certified Interior Designer - d. Cost Estimator; - i. Must be Certified by the following: - 1. AACE; - 2. ICEC, and/or; - 3. PCEA; - ii. Firm and/or Consultants must be: - 1. Specifically Identified; - 2. Competence Indicated by Resume - e. Sustainability Specialist; - i. LEED-AP - ii. Commissioning Agent - 3. Criteria C: Specialized Experience and Technical Competence in the type of work required, including, as appropriate, experience in sustainable design, energy conservation, pollution prevention, waste reduction, and the use of recovered materials. Examples and representative projects related to roofing systems repair and construction are preferred and recommended. - a. Design of Military Projects - i. Programming Documents; - ii. Plans; - iii. Specifications - b. Design of Government and Commercial Facilities; - c. Sustainable Design - i. Utilization of Leadership in Energy and Environmental Design (LEED) rating tools; - ii. LEED Certified Projects - iii. LEED Registered Projects - iv. LEED Accredited Professionals - d. Use and Compliance of DoD Unified Facilities Criteria (UFC) and Unified Facilities General Specifications (UFGS); - e. Use and Compliance of International Building Code (IBC) - f. Preparation of Related Permit applications - g. Design Tools such as CAD - h. Construction Quality Assurance/Construction Quality Control (CQA/CQC); - i. Submittal Evaluation; - ii. Construction Surveillance; - i. Standard Form 330, Block H - i. Quality Management and Assurance Plans (QMPs & QAPs); - ii. Cost Controls - iii. Significant Experience, to include other firms; - 4. Criteria D: Capacity to accomplish multiple tasks in the required time; - 5. Criteria E: Location(s) of Offices; - a. Ability to deliver services to location; - b. Knowledge of location (e.g. climate, local work force, etc.) and - i. Local Laws - ii. State Laws - 6. Criteria F: Volume of DoD Work; - 7. Criteria G: Small Business Participation; - a. Small Business; - b. Small Disadvantage Business; - c. Women-Owned Small Business; - d. HUB Zone Small Business; - e. Veteran-Owned Small Business, and/or - f. Service-Disabled Veteran-Owned Small Business This is not a request for proposal. NOTE: To avoid a conflict of interest, any contractor proposing as a prime may not have a subcontractor who is also proposing as a prime. Solicitation packages shall not be provided. Declaration of Interest and applicable SF 330's shall be submitted no later than 3:00 P.M. Eastern Time on 20 September 2016. Regulation requires that the Selection Board not consider any submittals received after this time and date. Late submission rules in FAR 15.208 will be followed for submittals received after 3:00 P.M. Eastern Time on the closing date specified in this announcement. Interviews are not planned to be conducted at this time. All questions shall be in writing to the POC listed above. Phone calls and personal visits for the purpose of discussing this solicitation with ANG contracting/project management and or engineering personnel are not allowed. To verify your SF 330 submittals and any supplemental information have been received, you may e-mail the Base Contracting Officer. SUBMIT QUESTIONS ONLY TO: The Base Contracting Officer (Gordon Strom, contact@example.gov ). No phone questions will be honored. Questions will be answered in writing via email or in request for information (RFI) format

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS