Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Veterans Affairs was posted on June 1, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

C1DA--557-23-102 Correct & Replace all Utility Systems FCA Deficiencies throughout the Facility (VA-22-00057016)

Awarded
36C24723R0007Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

Project 557-23-102 involves the architectural and engineering services required to correct and replace utility systems FCA deficiencies at the Carl Vinson VA Medical Center in Dublin, Georgia. The scope of work includes correcting deficiencies in DWV plumbing, potable water, process steam, chilled and heating water lines, and condensate return systems and pumps. Additionally, the project entails updating electrical utility delivery systems, renovating distribution closets for code compliance, removing unused utility piping, and eliminating plumbing dead-legs to meet Legionella standards. The estimated construction magnitude for these improvements is between 10 million and 20 million dollars, with a target completion period of 240 calendar days after the Notice to Proceed. This contract was a 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 541330 for Engineering Services. Procurement followed the Brooks Act selection procedures, requiring firms to be licensed to practice in the state of Georgia and verified through the Center for Veterans Enterprise and VetBiz. The contract, solicitation number 36C24723R0007, was awarded on June 1, 2023, to RGD Consulting Engineers Orlando, LLC, for a total award amount of 1,522,688.06 dollars.

General Info

Contract Value

$1,491,495.03

NAICS

541330 - Engineering Services

Place of Performance

GA, USA

Set-Aside

SDVOSBC

Award Issued Date

Documents

3

36C24723R0007 - A/E Correct & Replace All Utility Systems FCA Deficiencies

PDF, High priority: read this firstpresolicitation
High

Award 36C24723C0084 - Utility Systems FCA Deficiencies (Carl Vinson VA Medical Center)

DOCX, Low priorityaward
Low

Past Performance Questionnaire and Cover Letter - VA NCO 7

DOCX, Low prioritypast-performance
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
PhaseAwarded
Posted

Presolicitation

Notice updated

Response deadline added: Oct 1, 2022. The notice title changed. The notice description changed. The point of contact changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 247-NETWORK Contract Office 7 (36C247)
Contacts1 person available
OfficeAUGUSTA, GA, 30904, USA
Office AddressAUGUSTA, GA, 30904, USA
Contacts
Christopher JenkinsContracting Specialist

Full Description

Show more
This Pre-solicitation Notice is NOT A REQUEST FOR PROPOSAL. ALL INFORMATION NEEDED TO SUBMIT SF330 DOCUMENTS ARE CONTAINED HEREIN. NO ADDITIONAL SOLICITATION PACKAGE OR TECHNICAL INFORMATION WILL BE ISSUED. Project: 557-23-102 - A/E Correct & Replace All Utility Systems FCA Deficiencies Work Location: Carl Vinson VA Medical Center Dublin, GA 31021 Estimated/Target Completion Period: 240 calendar days after Notice to Proceed (NTP). Construction Magnitude: Between $10,000,000 and $20,000,000. NAICS: 541330 Engineering Services Small Business Standard: $22.5 million Set-Aside: 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) Site Visits will not be arranged during this phase. The anticipated award date of the proposed A-E Contract is on or before December 30, 2022. SF 330 Date of Receipt/Due Date: Interested firms having the capabilities to perform this work must submit one (1) electronic SF 330 and attachments (if any) no later than (NLT) 12:00 PM (EST) September 30, 2022. PROJECT OVERVIEW: The purpose of this project is to correct FCA deficiencies in utility systems including: all DWV plumbing, potable water, process steam, chilled water & heating water lines, condensate return lines/condensate return pumps, electrical utility delivery systems as well as renovate distribution closets to bring up to code compliance; as well demolish and remove all existing utility piping currently not in use, as well as remove all plumbing dead-legs not in compliance with Legionella standards. SDVOSB SET-ASIDE: This requirement is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses under the authority of 38 U.S.C. 8127(d). To be eligible for award the SDVOSB you must be considered small under the relevant NAICS code. SDVOSB contractors must be verified and viewable in VetBiz www.vip.vetbiz.gov prior to submission of proposal and prior to award of contract with VAAR 804.1103-70. Status as a qualified SDVOSB concern is under the authority of 38 CFR Part 74 in accordance with the VA Acquisition Regulation (VAAR) Part 819. Any person, persons, or business entity suspected of misrepresenting itself for the purpose of securing a government contract may be criminally investigated and prosecuted for fraud against the United States of America. Parties found misrepresenting their status also risk debarment from further Government contracts. Eligibility determination is performed by the Center for Veterans Enterprise (CVE). Eligible SDVOSB concerns must also be registered at the following websites: System for Award Management (SAM): https://www.sam.gov/portal/public/SAM/ VETS100/100A Report must be complete: http://www.dol.gov/vets/vets4212.htm Important Notice: Prior to submitting a proposal under this SDVOSB set- aside solicitation; offerors must apply for and receive verification from the Department of Veteran Affairs Center for Veterans Enterprise (CVE) in accordance with 38 CFR Part 74 and VAAR 819.70 by submission of documentation of Veteran status, ownership and control sufficient to establish appropriate status. All offerors are urged to contact the CVE and submit the aforementioned required documents to obtain CVE verification of their SDVOSB status if they have not already done so. For a Service-Disabled Veteran Owned Small Business (SDVOSB) to be considered as a prospective contractor, the firm, including Joint Ventures, must be verified and registered in the Department of Veteran Affairs (VA) Office of Small & Disadvantaged Business Utilization (OSDBU) Vendor Information Pages (VIP), VETBIZ (www.vip.vetbiz.gov , and registered in the System for Award Management (SAM) database (www.sam.gov) at time of submission of their qualifications. Failure of a prospective SDVOSB to be verified by the Center for Veterans Enterprise (CVE) at the time the SF 330 is submitted shall result in elimination from consideration. All Joint Ventures must be CVE verified at time of submission and submit agreements that comply with 13CFR 125.15 prior to contract award. In order to assure compliance with FAR Clauses, 52.219-14 Limitations on Subcontracting (DEVIATION 2019-01) and VAAR 852.219-10, VA Notice of Total Service-Disabled Veteran-Owned Small Business Set-Aside (JUL 2019) (DEVIATION), all firms submitting a SF 330 for this pre-solicitation notice are required to indicate what percentage of the cost of contract performance will be expended on the concerns employees and in which discipline(s) and percentage of cost of contract performance to be expended (and in what disciplines) by any other consultant/subcontractor or otherwise used small or large business entity(s). Any consultant/subcontractor or otherwise business entity(s) used must be identified by name, office location and size/type of business (i.e. SDVOSB, VOSB, 8(a), small, large, etc.). Failure to provide this information will deem the firm s SF 330 submittal as nonresponsive and preclude further evaluation. Federal Acquisition Regulation (FAR) Part 36.6 (Brooks Act) selection procedures apply. The A-E Services listed herein is being procured in accordance with the Brooks Act (Public Law 92-582) as implemented in Federal Acquisition Regulation (FAR) 36.6 and VAAR 836.6. Pursuant to FAR, the firm responding to this requirement must be permitted, by law, to practice the professions of architecture or engineering and meet all required qualifications for the state of Georgia. SF 330 SELECTION CRITERIA: The VA will utilize the following selection criteria in descending order of importance. Specialized experience and technical competence in the type of work required. Basis of Evaluation: Specialized experience pertains to the types, size, volume, budget, and complexity of work previously or currently being performed by the Offeror that is comparable to the work covered by this solicitation. Specialized experience may also include unique conditions, considerations, or circumstances encountered that are relevant to this solicitation. Specialized experience does not include overseas offices for projects outside the United States, its territories, or possessions; nor does it include subsidiaries that are not normally subject to management decisions, accounting, and policies, or a holding or parent company or an incorporated subsidiary that operates under a firm name different from the parent company. Technical competence includes construction and design projects similar in project scope, size, construction features, dollar value, and complexity of that listed in the solicitation. Technical competence also includes experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. Similar complexity is considered projects of an operational, construction, or design likeness to the work covered in this solicitation. Specific emphasis of experience and technical competence shall be geared primarily towards electrical systems design, while also demonstrating competence with related structure, fire protection, and healthcare facility design. Offerors unable to demonstrate proven specialized experience and technical competence may be considered non-responsive. Failure to provide requested data may negatively impact an Offeror's rating. Submission requirements: Submit a summary sheet for the Offeror and each key consultant. Each summary sheet shall not be more than one (1) page in length, and no more than fifteen (15) pages total. Past Performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules. Basis of Evaluation: Past performance is a measure of the degree to which an Offeror satisfied its customers needs and requirements and compliance with applicable codes, standards, laws, and regulations. The evaluation of past performance will include but is not limited to: The customer s assessment of the Offeror's commitment to customer satisfaction; Timely delivery of quality work; The Offeror's record of conforming to contract requirements and applicable codes, standards, laws, and regulations; Successful implementation of the Quality Control Plan and quality control procedures; Addressing design errors/omissions timely; Providing Construction Period Services satisfactorily to customers; Adherence to approved schedules; and, History of timely and professional communication and cooperative behavior. Include information on problems (errors/omissions) found, how the problems were corrected, and the impacts to the successful completion of the project (time delays, cost impacts, design modifications, etc.). Provide information supporting favorable cost control, quality of design submissions, and schedule compliance. Provide Contractor Performance Assessment Reporting System (CPARS) ratings for submitted relevant projects. If no CPARS data is available, provide Past Performance Questionnaires (PPQs). PPQs must be incorporated into the submission; CPARS reports and PPQs will not count towards page limitations. Offeror risks receiving a lower rating if fewer than three (3) are received. Include a discussion on the Offeror s record of significant claims for improper or incomplete design services. Higher ratings may be given for work performed on VA Medical Center campuses. Failure to provide requested data or to provide an accessible point of contact (POC) may negatively impact an Offeror's rating. Failure to demonstrate proven competence to perform projects like the requirements of the solicitation may be considered ineligible for award. Data from other projects not included in b) above are acceptable under past performance (such as cost control or schedule delays) in tables or charts. Submission requirements: Submit a summary sheet describing the Offeror s past performance. The summary sheet shall not be more than two (2) pages in length. Provide either a CPARS or PPQ for each submitted relevant project. Professional qualifications necessary for satisfactory performance of required. services. Evaluation of professional qualifications will include but is not limited to the subjective assessment of the Offeror's individual resumes. The Offeror shall have a professional engineer, registered in any state in the United States, knowledgeable in their appropriate design discipline, to be the lead designer responsible for reviewing and approving design submissions. The Offeror shall have a professional engineer, qualified and knowledgeable of state and local regulations, be the lead designer responsible for reviewing and approving design submissions and facilitating permit documentation (depending on the nature of the design i.e. environmental, stormwater, etc.). Key personnel to provide qualifications to meet this criterion include Principal(s), Project Manager(s), key consultants, individuals responsible for implementation of the Design QA/QC Plan, and other individuals that are responsible or accountable for design submissions. The Offeror shall describe and/or depict which projects and how well key personnel of the design team have worked together. Higher ratings for this criterion may be given when the Offeror's specific personnel demonstrate relevant credentials, such as professional engineer/architect registration, involvement, and degree of involvement in professional organizations, research/publications, code/standard body involvement, etc. Offerors unable to demonstrate professional qualifications necessary to perform designs may be considered non-responsive . Failure to provide sufficient data supporting professional qualifications may negatively impact an Offeror's rating. Submission Requirements: Submit personal resumes and relevant information for key and responsible personnel on SF330 documentation. SF330 documentation shall not be more than one (1) page in length, and not more than fifteen (15) total pages. Experience in construction period services to include professional field inspections during the construction period, review of construction submittals, support in answering requests for information during the construction period, and support of construction contract changes to include drafting statements of work, and cost estimates shall be included as an evaluation criterion when construction period services is included in the statement of work for A-E services. Evaluation of the Offeror s knowledge, skills, and abilities to complete necessary Construction Period Services (CPS) to support successful project completion. Provide a narrative describing the below services, but not limited to: Professional field inspections, both scheduled and emergent; Maintaining a comprehensive submittal log inclusive of material data, shop drawings, certifications, etc.; Review of construction submittals for design conformance, variance, and applicable code/standard compliance; Providing timely and complete responses to requests for information; Providing supporting documentation (statements of work, cost estimates, technical reports, etc.) for construction modifications; Providing record drawing documentation; Process for correcting design errors/omissions identified during construction; and, Other requirements defined under CPS in the Statement of Work. Submission Requirements: Provide a narrative that describes the Offeror s performance completing CPS for construction. Narrative shall not be more than one (1) page in length Location in the general geographical area Dublin, GA, and knowledge of the locality of the Carl Vinson VA Medical Center. 6) Basis of Evaluation: Offeror s will be subjectively evaluated based on their knowledge (and the knowledge of subcontractors) of unique conditions or variables, such as familiarity of applicable codes, regulations, construction market & labor conditions, geotechnical, seismic, weather, environmental, or other unique considerations found in the Dublin, GA geographical area. If prior experience in Dublin, GA is minimal, describe how the design team plans to obtain specific knowledge of local conditions or project features required for a compliant design. Data from other projects are acceptable to highlight knowledge of the Dublin, GA geographical area. Offerors that submit relevant projects outside of the Dublin, GA geographical area may be given a lower rating than projects within the Dublin, GA geographical area. Submission Requirements: Provide a narrative that describes the Offeror s experience in the Dublin, GA geographical area. Narrative shall not be more than one (1) page in length. Implementation of a Design Quality Assurance/Quality Control (QA/QC) Plan. Basis of Evaluation: Provide a Preliminary Design QA/QC Plan and associated procedures to be utilized on this solicitation that demonstrates that the design submissions, drawings, plans, specifications, submittal logs and other relevant information will go through a rigorous review process and coordination effort within the A/E firm and with subcontracted firms. Denote industry standards, best practices, and performance improvements taken to increase efficiency and quality, Identify the roles and responsibilities of the major personnel of the Offeror. It is expected that a Principal of the Offeror, knowledgeable and engaged with the project, reviews and approves submissions prior to their submission. Identify the key personnel that are expected to be accountable for the implementation of the QA/QC plan and responsible for completion of contract requirements. Depict the successful implementation of the QA/QC plan/procedures in the submitted relevant projects. Failure to provide QA/QC plan/procedures for each project may negatively impact an Offeror s rating. Describe the process for finding and mitigating design errors/omissions during design. Submission Requirements: Provide a preliminary Design QA/QC Plan and any associated procedures to be utilized for this solicitation. Provide a summary sheet depicting the successful implementation of the Design QA/QC Plan. The summary sheet shall not be more than one (1) page in length. Capacity to accomplish the work in the required time. Basis of Evaluation: Identify the Offeror s past, present and projected future workload, including VA contracts over the previous 12 months. Describe the Offeror s capacity to incorporate this solicitation s work while meeting prescribed dates for current workload. Each key team member to include % of available capacity to take on new project. Evaluation of this factor will be an assessment of the Offeror s ability to complete design documents within the period of performance and meet solicitation requirements. Data from other projects are acceptable in tables or charts. Higher ratings may be given for this criterion when information provided exceeds the minimum requirements. Submission Requirements: Provide a narrative that describes the Offeror s work capacity. Narrative shall not be more than one (1) page in length. The extent to which potential contractors identify and commit to the use of service- disabled Veteran-owned small businesses, Veteran-owned small businesses, and other types of small businesses as subcontractors. Basis of Evaluation: Offerors shall be evaluated based on their utilization plans for service- disabled Veteran- owned small businesses (SDVOSBs), Veteran-owned small businesses (VOSBs), or other types of small businesses. Offerors shall submit qualifications for proposed consultants per other criteria in this solicitation. Submission Requirements: Provide a narrative that discusses the Offeror s approach. Narrative shall not be more than one (1) page in length. The following format shall be used: Cover Page with Solicitation Number, Project Title Table of Contents SF 330 s Copy of Current A/E License Copy of current vetBiz.gov SDVOSB certification UEI Number Cage Code Tax ID number The E mail address and Phone number of the Primary Point of Contact. All SF330 submittals and questions must be sent electronically to the attention of Christopher Jenkins, Contract Specialist at contact@example.gov please provide Pre-Solicitation Number, Project Title, and Firm Name in Subject Line of email. When submitting SF330s, if more than one email is sent, please number emails in Subjects as 1 of n . Submittals received after the date and time identified on page one (1) will not be considered. Firms not providing the required information may be negatively evaluated. Facsimile submittals will not be accepted. All information must be included in the SF330.

More opportunities from Department Of Veterans Affairs → 247-NETWORK Contract Office 7 (36C247)

Same awarding agency

NAICS: 485991
New
Federal
Charleston VAMC wheelchair transportation service
Solicitation # 36C24726R0123
The Department of Veterans Affairs, Ralph H. Johnson VA Medical Center, is soliciting proposals for a five-year Firm-Fixed Price IDIQ contract to provide non-emergency ground wheelchair transportation services. This requirement is set aside exclusively for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS 485991. The anticipated period of performance runs from December 1, 2026, to November 30, 2031, with a guaranteed minimum of $25,000 for the first fiscal year and a maximum ceiling of $22,000,000. The contractor must provide all personnel, ADA-compliant vehicles, and equipment to transport Veteran patients between VA facilities, community hospitals, and personal residences, operating 24 hours a day, 365 days a year. Award will be based on the most advantageous offer, with relevant experience weighted as more important than price. Proposals must be submitted in PDF format to Thomas Nicholls by November 16, 2026, at 08:00 AM EST. Key requirements include the submission of a Quality Control Plan, evidence of state and local insurance compliance, and a signed Business Associate Agreement. The contractor is held to strict performance standards, including a 99 percent customer service rating and the requirement that all employees be proficient in English and trained in HIPAA and safe patient transport. Performance will be monitored via a Quality Assurance Surveillance Plan, and vehicles are subject to inspection at any reasonable time.
Special Needs Transportation

POSTED

about 11 hours ago

DEADLINE

in 18 days
View Details
NAICS: 236220
New
Federal
Y1DA--FY27 NRM | 619-24-103 | Replace Flooring & Repair Walls in Building 1 (VA-27-00012190)
Solicitation # 36C24727R0009
This Firm Fixed Price Construction contract, identified as project 619-24-103, involves the renovation of designated interior areas of Building 1 at the Central Alabama Veterans Health Care System, West Campus in Montgomery, Alabama. The scope of work includes replacing flooring, repairing and painting walls, installing wall-protection systems and handrails, refinishing doors and frames, and replacing water fountains with bottle-filling stations. The project is estimated to have a magnitude between 1,000,000 and 5,000,000 dollars with a target completion period of 365 calendar days from the award or notice to proceed. Because the work occurs in an operational medical facility, the contractor must implement phased execution, infection-control containment, and interim life-safety measures to protect patients and staff. This acquisition is a 100 percent set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSBs) under NAICS code 236220. Eligible firms must be registered in the SAM database and certified in the SBA database. Per VAAR Clause 852.219-75, special trade contractors are limited to paying no more than 75 percent of the government contract amount to firms that are not certified SDVOSBs or VOSBs. The government will utilize a Trade-Off Source Selection process to determine the best value. This notice is a presolicitation; formal proposals should not be submitted until the official RFP is posted, which is expected on or about November 16, 2026.
Commercial and Institutional Building Construction

POSTED

1 day ago

DEADLINE

in 14 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS