Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 2 at 2:00 PM EDT

Register Free →

Cable

Active
Z5034State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Tennessee → Nashville Electric ServiceView Agency

NAICS

N/A

Place of Performance

Nashville, TN, USA

Set-Aside

NONE

Documents

(1)

Z5034_RFB.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

What is UCF?

Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseSolicitation
Posted

Solicitation

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyTennessee → Nashville Electric Service
Contacts1 person available
OfficeNashville, TN, USA
Organization / Agency
Tennessee → Nashville Electric Service
View Agency Profile
Office AddressNashville, TN, USA
Contacts
Bailey AllenProcurement Contact

Full Description

Show more
ON QPXD CABLE AL600V XLP 4/0 2/ON QPXD EC ALUMINUM, 600 VOLTS, THREE 4/0 19 STRAND QUADRUPLEXED WITH ONE 2/0 19 STRAND NEUTRAL. CROSSLINKED POLYETHYENE INSULATION, MINIMUM 80 MILS THICK. TYPE USE-2 FOR 90 DEGREE C. SERVICE CONDUCTORS TO MEET ICEA SPECIFICATIONS, AND TO BE UL LABELED. PHASE CONDUCTORS TO BE MARKED WITH LABELS "A" "B" AND "C". NO EXCEPTIONS OR ALTERNATE METHODS TO THIS IDENTIFCATION WILL BE ACCEPTED. THE PHASE AND/OR NEUTRAL CONDUCTOR TO BE IMPRINTED WITH MANUFACTURER NAME, SIZE, "AL 600V XLPE" AND YEAR OF MANUFACTURE. THE NEUTRAL IS TO HAVE SEQUENTIAL FOOTAGE MARKING. ALL CABLE ENDS TO HAVE WATER TIGHT SEALS. CODENAME IS WAKE FOREST/XLP/EYS. ALL REELS MUST CONTAIN APPROXIMATELY 1000 CIRCUIT FEET. ALL REELS MUST BE CONSTRUCTED OF SOUND WOOD WITH EITHER WOOD OR STEEL DRUMS. ALL REELS MUST BE LESS THAN 69" IN OVERALL DIAMETER AND MUST BE LESS THAN 44" IN OVERALL WIDTH. ALL REELS MUST HAVE METAL CENTER HUB COLLAR. THE FOLLOWING INFORMATION MUST BE STAMPED ONTO THE REELS: "TARE WEIGHT: #####" "NET WEIGHT: ######" "GROSS WEIGHT: #####"

More opportunities from Tennessee → Nashville Electric Service

Same awarding agency