CALIBRATOR, AIR SAMP
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
This contract is for the procurement of three primary standard pump calibrators designed for the occupational health and safety industry. These devices are used to calibrate personal air samplers and volumetric instruments, featuring a flow range of 50 to 5000 ml/min and specific accuracy ratings for volumetric and standardized readings. Each unit must include a power adapter, BIOS optimizer software, serial cable, leak test caps, a manual, and a NIST-traceable calibration certificate. The supplier must adhere to strict packaging and marking standards, specifically Medical Marking Standard No. 1 and MIL-STD-130 for Item Unique Identification. Compliance with DFARS 252.211-7003 is required, and items must be shipped in suitable sealed unit containers within commercial exterior packaging to ensure safe delivery. The delivery timeline is set for 85 days after the order is placed, and bidders are required to specify the source and part number of the equipment being supplied.
General Info
Agency
NAICS
Place of Performance
UNIT 15479, APO, AP, 96260-5479, USASet-Aside
Documents
(1)AI Contract Breakdown
Uniform Contract FormatWhat is UCF?
Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.
Timeline
Response Deadline
Organization & Contact Information
Full Description
CALIBRATOR,AIR SAMPLING
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
This item requires Item Unique Identification (IUID) in accordance with the enclosed/referenced IUID technical requirements and MIL-STD-130. DFARS 252.211-7003 clause applies. APPLICABLE TO ALL MEDICAL ACQUISITIONS:
PACKAGING AND PACKING SHALL BE COMMERCIAL AS SPECIFIED IN THE PROCUREMENT DOCUMENT.
EACH COMPLETE UNIT SHALL BE PROPERLY PACKAGED IN A SUITABLE SEALED UNIT CONTAINER CAPABLE OF PROTECTING THE CONTENTS FROM DAMAGE AND/OR BREAKAGE.
UNITS SHALL BE PACKED IN SUITABLE COMMERCIAL EXTERIOR (SHIPPING) CONTAINERS (EXPORT WHEN NECESSARY) WHICH SHALL INSURE ACCEPTANCE AND SAFE DELIVERY BY COMMON OR OTHER CARRIER, AT THE LOWEST RATE, TO POINT OF DELIVERY CALLED FOR IN THE CONTRACT OR ORDER.
MATERIAL MUST BE MARKED IAW MEDICAL MARKING STANDARD NO. 1. THIS SUPERCEDES ALL REFERENCES TO MIL-STD-129.
COPIES OF MEDICAL MARKING STANDARD NO. 1 (MMS NO. 1) MAY BE OBTAINED BY CONTACTING DLA TROOP SUPPORT VIA EMAIL TO fssb@dla.mil. MMS NO. 1 IS ALSO AVAILABLE ONLINE AT: https://www.dla.mil/Logistics-Operations/Packaging/
RD003, COVERED DEFENSE INFORMATION POTENTIALLY APPLIES
This item requires Item Unique Identification (IUID) in accordance with the enclosed/referenced IUID technical requirements and MIL-STD-130. DFARS 252.211-7003 clause applies. RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS (IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
This item requires Item Unique Identification (IUID) in accordance with the enclosed/referenced IUID technical requirements and MIL-STD-130. DFARS 252.211-7003 clause applies.
SPE2DH-26-T-5916
SECTION B
PRIMARY STANDARD PUMP CALIBRATOR
DESIGNED FOR OCCUPATIONAL HEALTH AND
SAFETY INDUSTRY; SENSES AMBIENT TEMPERATURE
AND PRESSURE AND STANDARDIZED CALIBRATION
READINGS USED FOR ACCURATE CALIBRATION OF
PERSONAL AIR SAMPLERS AND OTHER VOLUMETRIC
INSTRUMENTS FLOW RANGE: 50 TO 5000 ML/MIN; RATED ACCURACY:
+/1 PCT OF READING VOLUMETRIC, +/1.2 PCT OF READING STANDARDIZED;
DIMENSIONS: 5.5 IN X 6 IN X 3 IN;
WEIGHT: 29 OZ INCLUDES: 100-240 V AC POWER US ADAPTER/CHARGER<(>,<)>
BIOS OPTIMIZER SOFTWARE CD, PC SERIAL CABLE, PLASTIC LEAK TEST CAPS (2),
NIST-TRACEABLE CALIBRATION CERTIFICATE, AND MANUAL
UNIT OF ISSUE EA(EACH)
BIDDER: PLEASE SPECIFY SOURCE AND PART
NUMBER BEING SUPPLIED.
ADEQUATE DATA FOR THE NSN/Part Number: 6640-01-583-9099 Quantity: 3 EA Purchase Request: 7017835651QTY: 3 Delivery: 85 days ADO
Similar Contracts