Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on May 12, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

CANCELLED - POWER PANEL ENCLOSURE

Closed
W519TC25Q2229Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The contract involves the procurement of power panel enclosures designed for transmission and distribution applications, specifically for the McAlester Ammunition Plant in Oklahoma. The solicitation, posted on SAM.gov under number W519TC25Q2229, emphasizes a total small business set-aside under NAICS code 335999. The project requires the delivery of two distinct power panel enclosures: one rated at 225 amps with a model B7L50 - 342 - MBC225, suitable for hazardous locations with a 120/208 VAC three-phase voltage, and another rated at 480 volts with model B7P50 - 324 - MBE100, also compliant with hazardous location standards. Both enclosures must meet UL standards, feature specific wiring configurations, and include a main breaker. The delivery point is FOB destination at the McAlester Army Ammunition Plant, with a response deadline of May 19, 2025. Bidders are instructed to submit their proposals via email to Andrea Jones and to regularly check SAM.gov for any updates or amendments to the solicitation. All vendors must have an active registration in SAM to be eligible for award.

General Info

US Army canceled solicitation for two hazardous-location power panel enclosures, total small business set-aside.

NAICS

335999 - All Other Miscellaneous Electrical Equipment and Component Manufacturing

Place of Performance

OK

Set-Aside

SBA

Documents

3

Amendment 0001 to Solicitation W519TC25G2229

PDF, High priority: read this firstamendment
High

Amendment 0002 to Solicitation W519TC25G2229

PDF, High priority: read this firstamendment
High

Solicitation W519TC25Q2229 - Power Panel Enclosures

PDF, High priority: read this firstrfq
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

3 updates
PhaseClosed
Posted

Combined Synopsis

Notice updated

Response deadline changed from Apr 14, 2025 to Apr 16, 2025. The notice description changed.

Notice updated

Response deadline changed from Apr 16, 2025 to May 19, 2025. The notice title changed. The notice description changed.

Notice updated

The notice title changed. The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W390 Mcalester Army Ammo Plant
Contacts1 person available
OfficeMCALESTER, OK, 74501-5000, USA
Office AddressMCALESTER, OK, 74501-5000, USA
Contacts

Full Description

Show more
THIS SOLICITATION IS POSTED TO SAM.GOV, ATTACHED SF1449 WITH COMPLETE DETAILS Amendment - Cancelled Solicitation in its entirety. Amendment- update the purchase description for CLIN 0001 and CLIN 0002. POWER PANEL ENCLOSURE, 225AMP, Brand Name Killark or Equal Model: B7L50 - 342 - MBC225, Series: B7L Series Transmission and Distribution-Panelboards Main Breaker, Hazardous Location Compliant 3-Phases, Max. Voltage-120/208 VAC, No. of spaces-42 Wiring configuration-4 wire, Standards- UL, CSAPOWER PANEL ENCLOSURE, 225AMP, Brand Name Killark or Equal Model: B7P50 - 324 - MBE100, Series: B7P Series Transmission and Distribution-Panelboards Main Breaker, Hazardous Location Compliant 3-Phases, Max. Voltage- 480 V, No. of spaces-24 Wiring configuration-4 wire, Standards-UL See attached SF1449 Solicitation for exact requirements. FOB Destination McAlester Ammunition Plant, McAlester OK. Note: Every item listed shall be accounted for in the offeror's bid submission for it to be considered. THIS SOLICITATION IS POSTED TO SAM.GOV, ATTACHED SF1449 WITH COMPLETE DETAILS BIDS SUBMISSIONS ONLY VIA EMAIL: contact@example.gov Any changes to the solicitation shall also be posted to this web site and it is the contractor's responsibility to check site daily for any posted changes. All contractors who provide goods/services to the DOD must have a current active registration at System for Award Management (SAM) - https://www.sam.gov.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS