Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Defense was posted on June 5, 2012. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Carbon Dioxide Fire Extinguisher Services BPA

Closed
FA8601-12-A-0050Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 561621
New
Centennial Fire Alarm & CO Detection Upgrade and Maintenance Services
Solicitation # centennial-fire-alarm-co-detection-upgrade-maintenance-services
Management & Training Corporation (MTC) is soliciting bids for a fixed-price, single lump sum contract to provide fire alarm and carbon monoxide (CO) detection upgrade and maintenance services at the Centennial Job Corps Center in Nampa, Idaho. The primary objective is to restore the central Simplex 4020 Fire Alarm Control Center Panel and connected systems across nine campus facilities to 100 percent normal operational status. Key technical requirements include diagnosing and clearing all active trouble statuses, upgrading the FACP motherboard or firmware if necessary, and integrating CO detection into the men's and women's dormitories using intelligent multi-criteria detectors and System Sensor B200S sounder bases. All work must adhere to NFPA 101 (2024), NFPA 72 (2025), IFC (2024), and local building and fire codes. Bids are due by December 1, 2026, and must be submitted via email. A mandatory physical site visit and signature on the attendance roster are required prior to bid submission. Proposals must include a detailed cost breakout on company letterhead, proof of insurance, and a bid bond equal to 20 percent of the base bid for projects valued at 25,000 dollars or more. Award decisions will be based on overall best value. This opportunity is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certifications. The project is subject to the Davis-Bacon Act and Construction Wage Rate Requirements, necessitating the payment of prevailing wages and the submission of weekly certified payroll reports for payment processing. Contractors must provide a 12-digit Unique Entity Identifier (UEI) and comply with FAR clauses regarding first-tier subcontractor reporting for awards over 40,000 dollars and debarment disclosures for subcontracts exceeding 45,000 dollars. Final payment is contingent upon a successful final inspection, the submission of a Notice of Final Completion, and the provision of a Certificate of Release of Liens.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 4 hours ago

DEADLINE

in about 1 month
NAICS: 561621
New
Federal
J042--Fire Alarm System Monitoring and Programming INTENT TO SOLE SOURCE
Solicitation # 36C25227Q0062
The Department of Veterans Affairs, through the Great Lakes Acquisition Center, intends to award a sole source, firm fixed price contract to Johnson Controls Fire Protection for fire and smoke alarm testing and fire suppression system services at the Captain James A. Lovell Federal Health Care Center in North Chicago, Illinois. The contract consists of a one year base period with four optional one year extensions. The scope of work requires 24/7/365 monitoring of all fire systems across various medical, long term care, and general buildings, as well as two scheduled technician visits per month on the second and last Thursdays. All services must comply with National Fire Protection Association codes, The Joint Commission standards, OSHA, VA standards, and ISO 9000. To execute these services, the contractor must provide personnel certified in Simplex Grinnell systems and technicians with a minimum NICET Level II certification. The monitoring service must be UL 827 or FM-approved. Key administrative requirements include the appointment of a dedicated contract manager, adherence to specific check-in and check-out procedures at Building 188, and the procurement of facility identification badges. Invoicing is required on a monthly basis, with separate detailed billing for monitoring and labor services. While this is a notice of intent to sole source under 41 U.S.C. 1901, other firms may submit capability statements and references via email to the contracting officer by October 28, 2026, for evaluation.
252-NETWORK Contract Office 12 (36C252)

POSTED

about 8 hours ago

DEADLINE

in 8 days
NAICS: 561621
New
SLED
1116-P-2627 Fire Protection Systems Testing, Inspection & Maintenance Services
Solicitation # 1116-P-2627
Portsmouth Public Schools is soliciting proposals for full-service fire alarm system testing, inspection, and preventive maintenance services for its facilities in Portsmouth, Virginia. The contract runs from the date of award through December 31, 2028, with three one-year renewal options. The selected contractor must provide all necessary tools and supplies to perform work in accordance with NFPA standards, the Statewide Fire Prevention Code, BOCA, IFC, and manufacturer specifications. Key deliverables include completed inspection reports, the affixing of inspection tags, deficiency reporting with corrective recommendations, and an annual Excel inventory of all equipment and system condition assessments. Qualified offerors must hold a Virginia Class A Contractor's license with FAS, FSP, SPR, FAE, and ESC classifications and maintain a local office within a 40-mile radius. Proposals are evaluated on a multi-step, qualifications-based process focusing on experience and methodology, with the intent to select two or more qualified vendors. Mandatory submission requirements include a detailed cost proposal, M/WBE compliance forms, a Contractor Employee Background Certification, and certification regarding debarment and suspension. Contractors must also provide $2 million in annual coverage and $1 million per occurrence in commercial general liability insurance, naming Portsmouth Public Schools as an additional insured.
Portsmouth Public Schools

POSTED

about 16 hours ago

DEADLINE

in 9 days
NAICS: 561621
New
SLED
FY27 COMMONWEALTH NONPROFIT SECURITY GRANT PROGRAM
Solicitation # BD-27-1044-EPS11-1044O-134580
The FY27 Commonwealth Nonprofit Security Grant Program, administered by the Massachusetts Executive Office of Public Safety and Security through the Office of Grants and Research, provides one-time competitive funding to 501(c)(3) nonprofit organizations. The program is designed to support target hardening and physical security enhancements for organizations at high risk of hate crimes or terrorist attacks, including faith-based institutions, medical facilities, and human service entities. A total of 4,465,000 dollars is available, with individual grants providing up to 75,000 dollars for the acquisition and installation of security technology and equipment. Applications must be submitted via the online Cognito portal by November 20, 2026, and must include a detailed budget Excel workbook. Awards are determined through a peer review process scoring applicants on need, project description, budget, implementation feasibility, and application clarity, with priority given to first-time awardees scoring 80 or higher. The performance period runs from January 1, 2027, to August 31, 2027, and all funded goods must be purchased, received, and installed by the end date, as these are use-or-lose state funds. Recipients are required to submit quarterly progress and financial reports and must adhere to M.G.L. Ch. 30B procurement standards.
EPS1100 - Office of Grants & Research

POSTED

1 day ago

DEADLINE

in about 1 month
NAICS: 561621
New
SLED
C26950006 - Inland Empire District - Alarm Monitoring Service Contract
Solicitation # C26950006
The California Department of Parks and Recreation is soliciting bids for an alarm monitoring service contract for the Inland Empire District. The selected contractor will provide 24-hour, seven-day-a-week monitoring and maintenance for 31 locations across the Perris, Chino, Mt. San Jacinto, and Silverwood Lake SRA sectors. The scope of work includes the installation, programming, and maintenance of security components such as motion sensors, door contacts, and panic alarms, utilizing Digital Monitoring Products XR150 Network Control Panels with cellular backup and the Virtual Keypad management system. The contract term is for three years, with an anticipated performance period starting February 2, 2027, and ending February 1, 2030. To be eligible, bidders must be a UL Certified Monitoring Center owned and operated by the security installation company and hold a valid California contractor's license as a C-7, C-10, or B contractor. Award selection is based on the Low Price Method, with evaluation incentives available for certified Small Businesses and Disabled Veteran Business Enterprises, as well as preferences under the Target Area Contract Preference Act for bids exceeding 100,000 dollars. Bidders must provide comprehensive insurance coverage, including general liability of 2 million dollars and motor vehicle liability of 1 million dollars. Sealed bids are due by November 6, 2026, at 2:00 PM.
California Department of Parks & Recreation

POSTED

1 day ago

DEADLINE

in 17 days

General Info

NAICS

561621 - Security Systems Services (except Locksmiths)

Place of Performance

1950 5TH ST B20018 R6, WRIGHT PATTERSON AFB, OH, 45433-7251, USA

Set-Aside

SBA

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA8601 Aflcmc Pzio
Contacts1 person available
OfficeWRIGHT PATTERSON AFB, OH, 45433-5344, USA
Office AddressWRIGHT PATTERSON AFB, OH, 45433-5344, USA
Contacts
Mohamed HusseinContract Specialist

Full Description

Show more
SOURCES SOUGHT SYNOPSIS FOR CARBON DIOXIDE FIRE PROTECTION SERVICES 30 MAY 2012 Sources Sought Solicitation Number: FA8601-12-A-0050 1.0 INTRODUCTION: This is a sources sought synopsis stating that the United States Air Force is seeking potential vendors for a contemplated competitive solicitation for a Blanket Purchase Agreement for work consisting of providing normal service, yearly inspections, testing, and emergency maintenance for three (3) high pressure carbon dioxide fire suppression systems and one (1) low pressure carbon dioxide system installed between 1940 and 2008 and one (1) Aqueous Fire Fighting Foam (AFFF) system at the Wright-Patterson Air Force Base, Ohio. This sources sought synopsis is intended for informational purposes only. The NAICS code for this action is 561621- Fire Alarm Monitoring and Installation Services size standard $12.5 Million. 1. SCOPE OF WORK. The work shall consist of providing normal service, yearly inspections, testing, and emergency maintenance for three (3) high pressure carbon dioxide fire suppression systems and one (1) low pressure carbon dioxide system one (1) Aqueous Fire Fighting Foam (AFFF) system. The Contractor shall furnish all equipment, labor, and materials, and shall perform all operations necessary to complete the work at Wright Patterson Air Force Base, Ohio. 2. LOCATION a. The site of the work is following buildings in Area B, Wright-Patterson AFB, Ohio. (WPAFB) (1) Building 18, one 17-ton bulk tank unit, Chemtron brand (low pres.) (2) Building 18B, Room 50 transformer vault, Room 51 transformer vault (low pres.) (3) Building 18C, Research Cell (RC) 18, RC 20, RC 21, RC 22, B003 (low pres.) (4) Building 18E, RC 22, RC 24, transformer vault Rm 50A (low pres.) (5) Building 18, Room 12, separate high pressure CO2 system (6) Building 490, Room 152, separate high pressure CO2 system (7) Building 490, Room 148, AFFF system (8) Building 71B, D-Bay, separate high pressure CO2 system b. The Contractor shall contact the Propulsion Directorate, AFRL/RZOEE, or an authorized Government representative a minimum of 72 hours before starting site operations. The phone number of the Government Representative will be provided at time of award. c. The Contractor shall visit the work area to become thoroughly familiar with all details of the work and working conditions, verify dimensions in the field, and advise the CO or an authorized Government representative of all discrepancies before performing any work. d. All work areas will remain occupied by Government personnel during performance of work. 3. COORDINATION AND SCHEDULING a. The Contractor shall coordinate all work with an authorized representative of the CO, Project Inspector, or the Real Property Building Manager (RPBM) for each building where a system is located to determine and ensure that work meets Government specifications. b. The Contractor shall provide a proposed work schedule for review and acceptance by the CO or by an authorized Government representative prior to starting any work. Because of the specialized operations in some areas protected by the CO2 and AFFF systems, the contractor may be required to perform the operations after normal working hours or on weekends. c. The Contractor shall perform the inspections to ensure that fire safety equipment meet the standards outlined in this document. 4. FIRE SAFETY a. The Contractor shall obey all requirements of the National Fire Protection Association (NFPA) 12 and Air Force regulations as outlined in Sections 7, 8, 9, 10, and 11 of this sources sought synopsis. b. The Contractor shall not do any welding or use any flame apparatus without obtaining prior clearance from the Fire Inspector. Any welding should be performed by a certified welder. The Contractor shall notify the Fire Inspector 24 hours in advance of the intended use of any flame apparatus. When using flame apparatus, the Contractor shall provide fire protection devices, such as noncombustible coverings and fire extinguishers, as requested by the Fire Inspector. 5. APPLICABLE PUBLICATIONS a. The Contractor shall comply with all required forms, specifications, and regulations, using the most up to date issue that is in effect on the date of the request for proposal. NFPA 12, Standard on Carbon Dioxide Fire Extinguishing Systems 1. Appendices to the referenced publication shall be considered part of the standard. Advisory portions of the standard shall be considered mandatory as if the word "shall" were substituted for the word "should." Any reference to the "Authority Having Jurisdiction" shall be interpreted to mean the Base Fire Protection Engineer. 6. PROTECTION OF GOVERNMENT PROPERTY AND PERSONNEL a. Work areas include the following: (1) Actual Construction Site; areas in which the work shall be accomplished or performed. (2) Storage Areas; areas used for the storage of materials and equipment to be used in the work. (3) Office and Shed Areas; areas for placing temporary field office, tool, or storage sheds. (4) Transportation Areas; areas that are defined as streets, roads, driveways, parking areas, or grass areas used for transportation purposes. b. Protect Government and Non-Government property and personnel from inconvenience and damage or injury of any nature. c. Accomplish all work in accordance with the provisions of Federal, State of Ohio Industrial Commission, and American Standard Safety Code for Building Construction, American Standard Association, applicable parts of Base Safety and Fire Prevention regulations, Air Force regulations, and such other measures as may be deemed applicable by the Base Ground Safety Office. The Air Force Project Inspector will assist in matters of safety and compliance for all Contractor safety requirements. d. The Contractor shall, with assistance from base personnel, locate all existing utility lines in the field before starting excavation of any kind. Contractor shall process an AF Form 103, Civil Engineering Construction Permit, prior to the excavation. Contractor shall notify base personnel 48 hours in advance to schedule an on-site clearance. e. The Contractor shall furnish, place, and utilize barricades per safety requirements. The Contractor shall keep access entry points and doors clear at all times. 7. STORAGE AND PROTECTION OF MATERIALS a. The Contractor shall store and secure all material used in the performance of the work. b. Access to on-base storage facilities is generally not available to contractors. If on-base, Government-provided storage space is not available, the Contractor shall provide a building, trailer, or other facility for storage of materials. Such storage facilities shall meet Air Force and Base fire regulations and approved by the Fire Inspector. The storage building, trailer, or other facility shall be sited and coordinated with the Base Civil Engineer. The facility shall be clearly marked on the outside with the name of the contractor and a day and evening phone number of the Contractor's point of contact in cases of an emergency. c. No materials shall be stored in unapproved storage areas. Whenever used in this document, "unapproved storage areas" means facilities not approved by the Fire Inspector for use or storage facilities that were approved by the Fire Inspector but that are not properly marked. d. The Contractor shall deliver materials to the site in good condition and free of defects. The Contractor shall store material in an organized fashion to maintain the area "fire-safe". Materials shall be protected from contact with the soil, moisture, and environmental elements until ready to be used. Materials shall be labeled for ready identification. Labels shall include name of manufacturer, and name and number of product. Damaged materials shall be removed from the site and replaced with approved materials. Contractor is responsible for inventory of items and accountability. 8. REMOVALS AND SALVAGE. a. The Contractor shall remove all excess items required to complete work and avoid obstruction. b. All removed materials shall become the property of the Contractor unless otherwise designated by the Government. Remove all materials from the work area's daily and dispose of materials off-base. 9. DAILY CLEAN-UP a. The Contractor shall keep the work area clean of all debris on a daily basis or more often as required and keep storage areas clean and orderly at all times. b. The Contractor shall dispose of combustible wastes at the end of each workday. Under no circumstances shall combustible waste accumulate. 10. UTILITIES a. The Contractor may request access to government utilities which are readily available in the work area (e.g. house current or tap water in buildings). Such a request must be approved by the CO or an authorized representative of the CO before the Contractor uses any Government utilities. b. Required utilities, which are not readily available in the work area or which would cause significant expense or inconvenience to the government, shall be provided by the contractor. c. Maintain all utilities for the duration of the work. The Contractor shall coordinate within 8 hours through the CO or through an authorized Government representative of the CO to request temporary disconnection of a utility for ANY period of time. d. All utility shutdowns for the purpose of disconnecting or connecting services which will affect areas outside the immediate work area shall be accomplished after normal base work hours or on weekends. Normal hours of operation are 0800-1630 Monday through Friday excluding Federal holidays, unless circumstances require contractor to work outside of the aforementioned parameters. e. Utility shutdown requests shall be accomplished in writing fourteen (14) full days in advance of the necessity for the shutdown. The request shall contain the following: (1) Name of contractor (2) Requested date for shutdown (3) Duration of shutdown (4) Buildings or parts of building affected (5) Utilities affected (6) Reason for shutdown f. The Contractor shall not proceed with shutdown until all approvals have been obtained and a signed AF Form 103, Civil Engineering Construction Permit, has been issued. g. Damage of any nature caused by work shall be repaired or damaged property replaced at no expense to the Government. If the Contractor does not satisfactorily repair in accordance with AF Regulations stated in Sections 8 through 12 of this DOCUMENT, or replace the damaged property, the Government reserves the right to take any necessary corrections and charge the Contractor. The Contractor shall reimburse the government for consequential damages for all materials and labor used in the corrections. 11. ENVIRONMENTAL PROTECTION a. Do not discharge fuels, oils, pesticides, or any other toxic or hazardous substance into the storm or sanitary sewers of WPAFB. Use all means available and necessary to control dust and prevent erosion on the construction site. b. Open burning is not permitted on base. c. Control litter at all times by keeping it in containers. Remove construction debris from WPAFB and dispose of it in a State approved landfill. d. Remove all equipment, drums, containers, and all other construction material upon contract completion. e. Coordinate with the 88th Environmental Management Branch, 88th CEAN, (937) 257-7152, prior to the start of any contract involving the removal and disposal of asbestos, polychlorinated biphenyls, or other regulated hazardous waste. 12. SUBMITTALS a. The Contractor shall submit for approval all items described below: (1) Contractor's test plan as described in Section 14a. (2) Contractor's test report as described in Section 14c. (3) Manufacturer's information on all parts and components installed in the system by the contractor. Manufacturer's recommended testing procedures shall be provided also. Information shall be original copies and shall clearly show the model or style of component installed. 13. WORK TO BE COMPLETED a. The Contractor shall conduct a complete inspection and test of each fire suppression system on a yearly basis. The test shall include all functions of the system and devices listed below. A full discharge test is not required; however, a spurt test shall be performed (see Section 14a (12) for details). Seven (7) days prior to conducting the test, submit a detailed test plan to the RPBM and authorized CO Representative showing the devices and functions to be tested, the procedures used to perform the test and the schedule to be followed. The test plan must be approved by the CO or an authorized representative of the CO and the Base Fire Protection Engineer prior to beginning the tests. The following apply to all systems included in this contract and fulfillment of these tests constitutes a "complete inspection." Inspections and tests shall be conducted after fire suppression systems have been isolated from the main building alarm system by the base alarm shop. (1) Test the operation of all detectors in accordance with the manufacturer's recommendations. Provide a copy of the manufacturer's recommended testing procedure with the test plan required above. (2) Test the operation of all manual actuators. (3) Test the operation of all timers to assure the proper discharged time for each hazard. (4) Test the operation of all electromechanical pilot valves. (5) Test the operation of all master and selector valves. (6) Check the integrity of all piping, valves, and nozzles. Check and adjust the orientation of nozzles to ensure coverage of the hazard. (7) Test the operation of all audible and visual alarm indicating devices that are part of the fire suppression system. (8) Test the operation of all interlocks that are actuated by discharge of the fire suppression system. The tests are limited to assuring proper output signals from the existing system and controls. The Contractor shall not be responsible for operation of the interlock equipment unless it is a part of the fire suppression system. (9) Test the operation of all control panel functions and supervisory devices. This shall include a test of the secondary power supply. (10) Test the integrity of all electrical circuits within the system to assure there are no ground faults and the circuits are properly supervised, in accordance with the standards set forth in NFPA 12. (11) Test the operation of the refrigeration system and controls, including supervision of tank level and pressure. (12) Conduct a spurt test of each hazard to ensure that all nozzles and piping are free of obstructions. A spurt test is defined as an actuation of the system until the extinguishing agent can be seen discharging from each nozzle. As soon as discharge can be seen from each nozzle the test is terminated. The purpose of the test is to assure that all valves open properly and that all piping and nozzles are free of obstructions. (13) Provide liquid carbon dioxide to fill the low pressure CO2 systems. (14) The Contractor shall replace and/or maintain all signs pertaining to the fire suppression system. (15) The Contractor shall respond and arrive on base to emergency calls from the CO or an authorized representative of the CO within 24 hours of the repair call unless otherwise mutually agreed upon by the contractor, the CO, and/or the representative of the CO. b. The Contractor shall make repairs and modifications to the systems as required and approved by the Base Fire Protection Engineer. c. The Contractor shall submit two (2) copies of a complete report within fifteen (15) days of the conclusion of all inspection and testing, to the CO or to the authorized representative of the CO for review by the Base Fire Protection Engineer. The report shall contain the following: (1) A description of all actual tests conducted and the results of each test. (2) A complete description of all repairs and adjustments made by the contractor. (3) A description of additional work recommended by the Contractor to improve the performance or reliability of the system. Include an estimated cost for completion of each recommended change and a description of equipment required to complete the change. (4) Before and after pressure reading shall be submitted along with the before and after tonnage of the CO2 tank. (5) Certification that the systems were left in operating condition.

More opportunities from Department Of Defense → FA8601 Aflcmc Pzio

Same awarding agency

NAICS: 334516
New
Federal
Off-Axis Parabolic Mirrors
Solicitation # FA860127Q0003
The Air Force Life Cycle Management Center, on behalf of the Air Force Institute of Technology, is conducting market research via a Sources Sought notice to identify qualified sources for the manufacture and delivery of 66 customized off-axis parabolic mirrors and associated protected-gold coating services. These precision optical components are intended for use in the Extreme Light Laboratory to support ultra-intense laser experiments. The mirrors must feature a 30mm diameter fused-silica substrate with a parabolic focus at 45 degrees, a surface roughness of less than 1nm RMS, and a scratch/dig specification of 20-10. The required protected-gold coating must provide an average reflectivity of at least 97 percent at a wavelength of 780 plus or minus 40nm with a 45-degree angle of incidence. The selected contractor will be responsible for all labor, materials, quality assurance, and transportation to Wright-Patterson Air Force Base, Ohio. Key deliverables include the mirrors and comprehensive test data, including certificates of conformance and surface-measurement data. Delivery is required within 98 calendar days after receipt of order, and the equipment must be warranted against defects for two years following receipt. Payment terms are set at 100 percent after delivery, net 30 days from the invoice date. Interested parties under NAICS code 334516 must submit a capability package by October 23, 2026.
Analytical Laboratory Instrument Manufacturing

POSTED

about 8 hours ago

DEADLINE

in 3 days
View Details
NAICS: 334516
New
Federal
Sources Sought_Midwave Camera
Solicitation # FA860127Q0011
The Air Force Life Cycle Management Center, Installation Contracting Division, is conducting market research to identify potential sources capable of providing a 1.5-5 micron midwave camera and associated accessories for the Air Force Institute of Technology at Wright-Patterson Air Force Base, Ohio. This sources sought notice is for market research purposes only and is not a request for proposals. The government is seeking capabilities packages from all interested sources, including various small business categories, under NAICS code 334516. Interested firms must submit a concise capabilities package of no more than five pages by October 29, 2026, at 3:00 PM Eastern Time to the designated points of contact. The scope of work includes the delivery of the camera system, calibration of the instrument and lens, and the provision of a protective case. The contractor will be responsible for all transportation, loading, and onsite setup, with a required delivery timeline of no more than 90 days after contract award. Technical specifications include an operating temperature range of -10 C to 45 C and a two-year warranty against defects in material and workmanship. Payment is structured as 100% upon completion of all requirements on a net 30 basis, with invoicing processed through Wide Area Work Flow. The government is evaluating the potential for a small business set-aside and requires respondents to provide detailed information regarding their socio-economic status, ownership, and compliance with FAR clause 52.219-14 regarding limitations on subcontracting.
Analytical Laboratory Instrument Manufacturing

POSTED

6 days ago

DEADLINE

in 9 days
View Details
NAICS: 236220
New
Federal
SABER FY 27-32
Solicitation # FA860126R0019
The United States Air Force is soliciting proposals for the Simplified Acquisition of Base Engineering Requirements (SABER) FY27-32, a 100% 8(a) small business set-aside IDIQ contract. The selected contractor will provide all management, labor, materials, equipment, and design capabilities to execute over 100 simultaneous projects involving maintenance, repair, and minor construction of real property at Wright-Patterson Air Force Base, Ohio. The scope includes work on buildings, roads, roofs, and utilities, as well as hazardous waste remediation and design-build services from concept to 100 percent design. The contract has a maximum ceiling of 160 million dollars, which increases to 175 million dollars if the option for extended services is exercised. Performance is expected to begin within 10 days of award and spans a total period of 1,825 calendar days. Award will be based on the Lowest Price Technically Acceptable (LPTA) process. Proposals must first pass compliance gates, including a requirement for the prime contractor to be a US-owned and operated company. Technical evaluations are conducted on a pass/fail basis, focusing on the management approach and project planning and execution. Pricing is structured using RS Means line items and coefficients. Proposals must be submitted electronically via the Procurement Integrated Enterprise Environment (PIEE) Solicitation Module. Key requirements include adherence to Davis-Bacon Act wage determinations for Montgomery and Greene Counties, compliance with NIST SP 800-171 cybersecurity standards, and the provision of a minimum one-year warranty on all construction work.
Commercial and Institutional Building Construction

POSTED

6 days ago

DEADLINE

in 3 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS