Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Homeland Security was posted on August 16, 2022. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

CASTLE HILL BARRACKS FIRE ALARM SYSTEM

Closed
37020PR220000455Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 922160
SLED
2026 Volunteer Fire Capacity Grant
Solicitation # 2139681
The New York State Department of Environmental Conservation is administering the 2026 Volunteer Fire Capacity Grant Program, funded by a federal appropriation of 857,629 dollars. This program provides matching grants to eligible rural fire departments for the purchase of wildland firefighting suppression supplies. To be eligible, departments must be comprised of at least 80 percent volunteer personnel and serve a rural area, defined as a town or village with a population of 10,000 or less based on the 2020 Census. Selected departments can receive a maximum award of 3,500 dollars, which must be matched 50/50 by the recipient. Grant funds must be used for items directly related to wildland firefighting that benefit the local rural community, with a restriction that no individual item exceeds 9,999 dollars. Selection is based on the department's funding history over the previous five years, whether it is a newly formed establishment, and the presence of a Native American community within its jurisdiction. The program operates under federal guidelines from the US Forest Service and the Cooperative Forestry Assistance Act of 1978. Applications are accepted through December 30, 2026. This solicitation does not have specific goals for Service-Disabled Veteran-Owned, Minority, Women, or Disadvantaged Business Enterprises. All inquiries and applications are managed by the Volunteer Fire Capacity Grant Coordinator within the Division of Forest Protection.
NYS Department of Environmental Conservation

POSTED

8 days ago

DEADLINE

in 2 months

General Info

NAICS

922160 - Fire Protection

Place of Performance

Newport, RI, 02840, USA

Set-Aside

NONE

Documents

3

Final+Copy+SOW+22+MPOP+Sta+CH+Barracks+Fire+Alarm+Upgrade.pdf

PDF

SF18+REQUEST+FOR+QUOTATION+-+BARRACKS+FIRE+ALARM.pdf

PDF

WAGES.txt

TXT

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Homeland Security → Base Cape COD(00052)
Contacts2 people available
OfficeBUZZARDS BAY, MA, 02542, USA
Office AddressBUZZARDS BAY, MA, 02542, USA

Full Description

Show more
The awarded contractor shall provide all personnel, equipment, tools, materials, supervision, and other items and services necessary to install 10 new smoke detectors in the 2~ and 3~ floor berthing rooms. These rooms are currently not connected to the addressable system in the same Main Mission Building (MMB). All comleted work shall meet RI and federal fire detection codes. All work will be considered complete upon satisfactory testing of the system witnessed by the CG's QAI. Using a Rhode Island licensed electrician install 10 new smoke detectors that have the ability to be connected to the addressable system cunently installed in the building. The 10 rooms that work will be conducted are highlighted on the attached drawing. - Electronically connect the 10 newly installed detectors into the current monitoring system. - Test and certify all new detectors are functioning with the old in place system. - Remove and dispose of the 10 older smoke detectors. - Contractor is responsible for patching any holes left by the removed detectors. Contractors shall also paint over any patch work to match the ceiling. - Ensure USCG QAI and local unit customer are present and test all systems both new and legacy work as intended. SEE SOW FOR ALL DETAILS

More opportunities from Department Of Homeland Security → Base Cape COD(00052)

Same awarding agency

NAICS: 541990
Federal
FUEL TANK INTEGRITY TESTING
Solicitation # 31125PR260000720
The contract requires the contractor to perform comprehensive external and internal inspections of aboveground fuel tanks and potassium sodium tanks at USCG Base Cape Cod in Bourne, MA, over a four-year period with a base year and three option years. The scope includes external inspections of six aboveground fuel tanks—two 10,000-gallon gasoline tanks and three JP-8 aviation fuel tanks (one 30,000-gallon and two 15,000-gallon)—as well as two 5,000-gallon potassium sodium tanks located behind Building 124. Internal inspections and wall thickness measurements are required only on the 30,000-gallon and two 15,000-gallon JP-8 tanks adjacent to Taxiway Delta, and all work must comply with Steel Tank Institute SP001 and API 653 standards. The contractor must deliver detailed reports on tank conditions, including observed deterioration, test results, and estimated remaining service life, along with repair cost estimates. All work must adhere to Federal, State, and Local environmental regulations, with full compliance to OSHA standards and directives from the Base Safety Officer and Fire Department. The contractor is required to provide all personnel, equipment, materials, and supervision, with a licensed supervisor present onsite at all times who must be able to read, write, and speak English and have authority to approve minor modifications under $2,000. All personnel must be skilled and experienced. Prior to access, employees must undergo an NCIC background check, with personal information submitted seven days in advance, and all vehicles must meet Base entry requirements including valid insurance, registration, and driver’s license. The contractor must submit a Schedule of Work for approval before starting, complete daily logs submitted weekly, and submit a Safety Plan and Environmental Protection Plan—including a Storm Water Protection Plan—within 15 days of award, along with a Base Access Request Form within five days. Acceptance by the Contracting Officer’s Representative is mandatory and contingent upon site cleanup, punch list resolution, and all deliverables being submitted via approved forms. The contract mandates compliance with FAR 52.212-4, 52.222-90 (addressing DEI discrimination), and 52.246-21, and places full responsibility on the contractor for any damage to property, requiring repairs at their expense to original condition. Invoices must be submitted through IPP.gov, and
All Other Professional, Scientific, and Technical Services

POSTED

5 months ago

DEADLINE

N/A
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS