This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on March 23, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Central Lighting Inverters

Closed
FA462021QA210Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

335122 - Commercial, Industrial, and Institutional Electric Lighting Fixture Manufacturing

Place of Performance

Fairchild AFB, WA, 99011, USA

Set-Aside

SBA

Documents

2

Attachment+01+-+Salient+Characteristics.pdf

PDF

Combined+Synopsis+Solicitation.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA4620 92 Cons Lgc
Contacts2 people available
OfficeFAIRCHILD AFB, WA, 99011-5320, USA
Office AddressFAIRCHILD AFB, WA, 99011-5320, USA

Full Description

Show more
The 92 Civil Engineering Squadron requires four (4) Central Lighting Invertors for use in the dormitories. The equipment must possesses the following minimum salient characteristics. Model: D = LSN Centeral Lighting Invertor Input Voltage: 208 = 208V Capacity: 66 = 6.6KVA Battery Type: S = 10-year VRLA Lead-Calcium Output Voltage (VAC): 120 = 120V Output Circuit Breaker Type: Blank = Normally On Output Circuit Breaker Voltage Rating: A = 120VAC Output Circuit Breaker Ampere Rating: 40 = 40 AMP Output Circuit Breaker Quantity: 02 = 2 EA Output Circuit Breaker Supervision: Blank = Unmonitored IBS = Internal Maintenance Bypass Switch (Make Before Break) In addition, due to the construction of the facilities these units will have to be installed behind existing boilers. Since they will have to be lifted over existing hot water and steam piping in a small area in the boiler room it is imperative that the units must be able to be separated into sections that can be safely lifted and positioned by 4 individuals. Larger numbers of people will not fit in the work area.

More opportunities from Department Of Defense → FA4620 92 Cons Lgc

Same awarding agency

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS