General Info

NAICS

335313 - Switchgear and Switchboard Apparatus Manufacturing

Place of Performance

3301 F AVE CEN REC BLDG 506 DR 22, TINKER AFB, OK, 73145-8000, USA

Set-Aside

NONE

Documents

1
PDF, High priority: read this first19 pages · rfq
High

Read the document

Due in 11 days

Every page of every file, in your free workspace.

Read the document

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Due in 11 days

Everything you need to bid on this one

Open the full contract in your free workspace.

  • 1 solicitation documentRead every page
  • Buyer contactEmail and phone
Open the full contract

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

PhaseSolicitation
Posted

Solicitation

Response Deadline

Submission deadline

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → DLA WEAPONS SUPPORT ACTIVE DEVICES DIVISION
Contacts1 person available
OfficeUSA

Full Description

Show more
CIRCUIT BREAKER
CIRCUIT BREAKER
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS
(IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE
DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB
AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
MERCURY OR MERCURY CONTAINING COMPOUNDS SHALL
NOT BE INTENTIONALLY ADDED TO<(>,<)> OR COME IN DIRECT
CONTACT WITH<(>,<)> ANY HARDWARE OR SUPPLIES FURNISHED
UNDER THIS CONTRACT. EXCEPTION: FUNCTIONAL MERCURY
USED IN BATTERIES, FLUORESCENT LIGHTS, REQUIRED
INSTRUMENTS; SENSORS OR CONTROLS; WEAPON SYSTEMS;
AND CHEMICAL ANALYSIS REAGENTS SPECIFIED BY NAVSEA.
PORTABLE FLUORESCENT LAMPS AND PORTABLE INSTRUMENTS
CONTAINING MERCURY SHALL BE SHOCK PROOF AND CONTAIN
A SECOND BOUNDARY OF CONTAINMENT OF THE MERCURY OR
MERCURY COMPOUND. (IAW NAVSEA 5100-003D).
THE USE OF ANY CLASS I OZONE-DEPLETING SUBSTANCE
(ODS) IN THE DESIGN, MANUFACTURING, TESTING,
CLEANING, OR ANY OTHER PROCESS FOR THIS ITEM
UNDER ANY MILITARY OR FEDERAL SPECIFICATION,
STANDARD OR DRAWING REFERENCED IN THIS ITEM
DESCRIPTION IS "PROHIBITED" UNLESS THE SEPARATE
WRITTEN APPROVAL OF THE CONTRACTING OFFICER IS
OBTAINED. THIS PROHIBITION SUPERSEDES ALL
SPECIFICATION REQUIREMENTS BUT DOES NOT
ALLEVIATE ANY PRODUCT PERFORMANCE REQUIREMENTS.
THIS DOES NOT APPLY TO COMMERCIAL ITEMS, AS
DEFINED IN "FAR 11.001" OR TO PART-NUMBERED
ONLY ITEMS.
LEVEL 1/SUBSAFE REQUIREMENTS DO NOT APPLY
TO THIS ITEM.
THIS NSN IS LISTED AS A PRIMARY QPL OR QML THEREFORE
THE QUALIFIED PRODUCTS LIST OR QUALIFIED MANUFACTURERS
LIST IS APPLICABLE.
RD003, COVERED DEFENSE INFORMATION POTENTIALLY APPLIES
THIS NSN IS LISTED AS A PRIMARY QPL OR QML
THEREFORE THE QUALIFIED PRODUCTS LIST OR
QUALIFIED MANUFACTURERS LIST IS APPLICABLE.
RQ002: CONFIGURATION CHANGE MANAGEMENT ENGINEERING CHANGE PROPOSAL
REQUEST FOR VARIANCE (DEVIATION OR WAIVER)
CRITICAL APPLICATION ITEM
SPE7M5-27-T-3466
SECTION B
TDP Rev A Gen 2 IAW BASIC NON GOVT STD SAE AS58091B REVISION NR B DTD 07/01/2023 PART PIECE NUMBER: MS14154-2-1/2
TDP Rev A Gen 2 IAW REFERENCE NON GOVT STD SAE AS14154C REVISION NR C DTD 07/01/2016 PART PIECE NUMBER: MS14154-2-1/2
TDP Rev A Gen 2 IAW REFERENCE NON GOVT STD SAE AS58091 REVISION NR DTD 08/01/1999 PART PIECE NUMBER: MS14154-2-1/2
DLA issues this document using the DoD authorized unit of issue, please refer to the following URL to determine the corresponding ANSI X12 unit of issue.
https://view.officeapps.live.com/op/view.aspx?src=https%3A%2F%2Fwww.dla.mil%2FPortals%2F104%2FDocuments% 2FDLMS%2FeApplications%2FLogDataAdmin%2FUnitofIssueandPurchaseUnit.xlsx&wdOrigin=BROWSELINK
CLIN PR PRLI UI QUANTITY UNIT PRICE TOTAL PRICE.
0001 7019229735 0001 EA 23.000
NSN/MATERIAL:5925013084031
DELIVERY (IN DAYS):0161
DELIVER FOB: ORIGIN
QTY VARIANCE: PLUS 0% MINUS 0%
INSPECTION POINT: DESTINATION
ACCEPTANCE POINT: DESTINATION
PREP FOR DELIVERY:
PKGING DATA-QUP:001
IF MATERIAL IS CONSIDERED HAZARDOUS IAW FED-STD-313,
PACKAGE IN ACCORDANCE WITH TQ REQUIREMENT IP025.
IF THE MATERIAL IS NOT CONSIDERED HAZARDOUS, IN ACCORDANCE WITH
FED-STD-313, THE MATERIAL SHALL BE COMMERCIALLY PACKAGED IN ACCORDANCE
WITH ASTM D3951.
All DLA Master List of Technical and Quality Requirements take precedence over ASTM D3951. Mark and label all packaging and packing in accordance with MIL-STD-129. The Unit of Issue (U/I) and Quantity per Unit Pack (QUP) will be as specified in the contract/purchase order. PALLETIZATION SHALL BE IN ACCORDANCE WITH RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
PARCEL POST ADDRESS:
SW3211
DLA DISTRIBUTION DEPOT OKLAHOMA
3301 F AVE CEN REC BLDG 506 DR 22
TINKER AFB OK 73145-8000
US
SPE7M5-27-T-3466
SECTION B
PR: 7019229735 PRLI: 0001 CONT’D
FOR TRANSPORTATION SEE DLAD DLAD PROC NOTE C19. FOR FIRST DESTINATION TRANSPORTATION SEE DLAD PROC NOTE
C20 AND CONTRACT
FREIGHT SHIPPING ADDRESS:
SW3211
DLA DISTRIBUTION DEPOT OKLAHOMA
3301 F AVE CEN REC BLDG 506 DR 22
TINKER AFB OK 73145-8000
US
Need Ship Date:05/18/2027 Original Required Delivery Date:05/23/2027
SPE7M5-27-T-3466 NSN/Part Number: 5925-01-308-4031 Quantity: 23 EA Purchase Request: 7019229735QTY: 23 Delivery: 161 days ADO

Similar Contracts

Same NAICS industry code

NAICS: 335313
New
SLED
Double-Sided Padmount Solid Dielectric Switchgear with Integrated Automation - Purchase Order
Solicitation # SY270000491-LR
Anaheim Public Utilities is soliciting proposals for the procurement of double-sided padmount solid dielectric switchgear with integrated automation, specifically for stock codes PDSD-9 and PDSD-10. The project involves an initial R&D rollout requiring a total of 30 units, with 15 units per model. Delivery is phased, starting with three units for testing by May 2027 and full delivery by August 2027. All equipment must strictly adhere to City of Anaheim Specification E-153, featuring 15 kV switchgear and SEL 487E relays. Technical requirements include specific pad dimensions, with the CU 1600-3J usable pad dimensions confirmed as 61 by 60 inches and an overall pad width of 75.5 inches. The selection process is a competitive evaluation not limited to price alone. It consists of a two-phase approach: a pass/fail technical fit evaluation of minimum qualifications, followed by a points-based evaluation of pricing and lead time. Proposals must be submitted electronically via the portal by December 18, 2026. Awarded contracts will be FOB Destination, Anaheim, California. The manufacturer is responsible for the certification of ratings and must ensure all materials conform to ASTM, ANSI, IEEE, and NEMA standards. There is no specified set-aside status for this solicitation.
Anaheim Public Utilities

POSTED

about 20 hours ago

DEADLINE

in 21 days
View Details
NAICS: 335313
New
International
ASCO Automatic Transfer Switch for Brandrith Pump Station Generator
Solicitation # 26-231
The City of Delta is soliciting quotations for the procurement and delivery of an ASCO Power Technologies Series 7000 delay transition automatic transfer switch (Model H7ADTBA300800R5XM) for the Brandrith Pump Station Generator. The required hardware must feature a double-sided bypass/isolation capability, a continuous current rating of 800 A, and a system voltage of 600 V, 3 phase, 60 Hz, with a withstand and closing rating of 36 kA, 18 cycle. The unit must be factory assembled, wired, and tested prior to shipment, and it must be housed in a CSA Type 3R enclosure suitable for outdoor installation. The system must include an integrated microprocessor-based controller for voltage/frequency sensing, phase rotation monitoring, and event logging. The contract requires the supplier to provide a field technician for on-site commissioning and acceptance testing in the presence of the Engineer, with a minimum lead time of two to three weeks from checklist approval. Delivery is to be freight on board destination to 1600 Tsawwassen Drive, Delta, BC, with the equipment ready for delivery from June 15, 2027, onward; the supplier must provide storage at no additional cost to the City until that date. Bids must be submitted in a single PDF file in Canadian funds. The City will select the bid representing the best value, with a minimum score of 24/40 required for the Experience and Product criterion. Payment is due 28 days from the receipt of the invoice or satisfactory delivery, whichever is later. There is no set-aside status for this solicitation.
City of Delta

POSTED

2 days ago

DEADLINE

in 11 days
View Details

More opportunities from Department Of Defense → DLA WEAPONS SUPPORT ACTIVE DEVICES DIVISION

Same awarding agency

Get AI-powered intelligence on this solicitation and the ones like it

Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.

Miguel
Hillary
Keith Deutsch
Christine

Join 900+ contractors already using CLEATUS